Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 47688 dokumen yang sesuai dengan query
cover
Yunizah Nurpiandita
"ABSTRAK
Penelitian ini bertujuan untuk mengetahui jenis tanah, korelasi parameter tanah dengan kedalaman, dan korelasi antar parameter tanah di wilayah DKI Jakarta berdasarkan hasil pengujian laboratorium di Laboratorium Mekanika Tanah Universitas Indonesia. Hasil penelitian ini menunjukan bahwa jenis tanah DKI Jakarta dominan terdiri dari 2 (dua) jenis tanah yaitu MH (lanau dengan plastisitas tinggi) dan SM (pasir berlanau). Berdasarkan korelasi parameter tanah dengan kedalaman di wilayah DKI Jakarta maka didapatkan kadar air (Wc) berkisar 19.7-133.5%, liquid limit (LL) berkisar 39-129%, plastic limit (PL) berkisar 28-77%, plasticity index (PI) berkisar 8-51.5%, density (γ) berkisar 12.8-18.5 kN/m3, specific gravity (Gs) berkisar 2.5-2.77, kohesi (c) berkisar 0-69 kN/m2, sudut geser berkisar 0-31°, angka pori (e0) berkisar 0.4-3.1, tegangan overburden (Po) berkisar 15-144 kPa, tegangan pre-consolidated (Pc) berkisar 37-358 kPa, indeks kompresi (Cc) berkisar 0.09-1.51, dan indeks pemampatan kembali (Cr) berkisar 0.01-0.32. Berdasarkan korelasi index properties dan engineering properties, yaitu korelasi antara Cc dengan PI, Cc dengan LL, Cc dengan e0, Cc dengan Wc, e0 dengan Wc, dan e0 dengan γ, menghasilkan koefisien korelasi dengan tingkat hubungan kuat, kecuali korelasi antara Cc dengan PI dan Cc dengan LL pada Kelompok 1 dan Kelompok 2 kurang dapat diandalkan karena memiliki koefisien korelasi dengan tingkat hubungan rendah.

ABSTRACT
This study aims to determine the type of soil, the correlation of soil parameters with depth, and the correlation between soil parameters in the DKI Jakarta region based on the results of laboratory testing at the University of Indonesia's Laboratory of Soil Mechanics. Statistical data processing uses Microsoft Excel to graph, linear equations, calculation of the coefficient of variance (COV) and correlation coefficients. The results of this study indicate that the type of soil in the DKI Jakarta area is dominant consisting of 2 (two) types of soil, namely MH (silt with high plasticity) and SM (silty sand) with high plasticity. Based on the correlation of soil parameters with depth in the DKI Jakarta area, the Wc was 19.7-133.5%, LL was 39-129%, PL was 28-77%, PI was 8-51.5%, γ was 12.8-18.5 kN/m3, Gs was 2.5-2.77, c was 0-69 kN/m2, friction angles was 0-31°, e0 was 0.4-3.1, Po was 15-144kPa, Pc was 37-358kPa, Cc was 0.09-1.51, and Cr was 0.01-0.32. Based on correlation index properties and engineering properties, the correlation between Cc and PI, Cc with LL, Cc with e0, Cc with Wc, e0 with Wc, and e0 with γ, produces a correlation coefficient with a strong level of correlation.
"
2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Nadifa Aulia
"Sejak tahun 1980-an, Laboratorium Mekanika Tanah Universitas Indonesia memiki laporan hasil penyelidikan tanah berisi parameter tanah untuk Wilayah DKI Jakarta yang cukup banyak jumlahnya. Oleh karena itu pada penelitian ini data-data tersebut dipetakan kemudian diinterpolasi dengan menggunakan analisis geostatistik sehingga lokasi yang tidak diketahui nilainya dapat diestimasi dan peta parameter tanah untuk Wilayah DKI Jakarta dapat diketahui, dianalisis dan menjadi sarana identifikasi awal sebelum dilakukan penyelidikan tanah yang sebenarnya. Analisis geostatistik dilakukan dengan metode interpolasi kriging yang terdapat pada program ArcGIS 10.1 untuk setiap parameter tanah pada lapis kedalaman 0-5 meter, 5-10 meter, 10-15 meter, dan 15-20 meter. Berdasarkan hasil peta parameter tanah untuk Wilayah DKI Jakarta pada setiap lapis kedalaman diketahui bahwa nilai prediksi untuk parameter berat jenis berkisar antara 13.5-18 kN/m3, berat jenis kering antara 6-14 kN/m3, kadar air antara 36%-91%, batas cair antara 50-120%, batas plastis antara 31-65%, indeks plastisitas antara 20-80%, specific gravity antara 2.58-2.72, angka pori antara 1-2.2, distribusi persen pasir antara 2- 30%, distribusi persen lanau antara 33-74%, distribusi persen lempung 10-35%, kohesi antara 0-25 kPa, sudut geser antara 4-25o, OCR antara 1-8, indeks kompresi antara 0.25- 1.65, dan indeks pemampatan kembali antara 0.02-0.15. Pada penelitian ini peta berisi parameter tanah untuk Wilayah DKI Jakarta dapat dibuat dan dianalisis. Hasil analisis menunjukan adanya kecendrungan penurunan nilai seiring bertambahnya kedalaman pada parameter berat jenis, berat jenis kering, kadar air, batas cair, batas plastis, indeks plastisitas, persentase kandungan lempung, kohesi, sudut geser, dan OCR. Kemudian adapun kecenderungan peningkatan nilai seiring bertambahnya kedalaman pada parameter specific gravity, angka pori, indeks kompresi, indeks pemampatan kembali, persentase pasir, dan persentase lanau.

Since the 1980s, the University of Indonesia Soil Mechanics Laboratory has a report on the results of soil investigations containing a large number of soil parameters for the DKI Jakarta Region. Therefore, in this study the data is mapped and interpolated using geostatistical analysis so the unindetified value at few locations can be estimated and a map of soil parameters for the DKI Jakarta area can be known, analyzed and become a tools for initial identification before actual soil investigations are conducted. Geostatistical analysis was performed using the kriging interpolation method in ArcGIS 10.1 program for each soil parameter in layers of depth 0-5 meters, 5-10 meters, 10-15 meters, and 15-20 meters. Based on the results of the soil parameter map for DKI Jakarta
s known that the predicted value for the specific gravity parameter ranges from 13.5-18 kN/m3, dry density between 6-14 kN / m3, water content between 36% -91%, liquid limit between 50-120%, plastic limit between 31-65%, plasticity index between 20-80%, specific gravity between 2.58-2.72, void ratio between 1-2.2, distribution of sand percentage between 2-30%, distribution of silt percentage between 33-74%, distribution of clay percentage between 0-35%, cohesion between 0-25 kPa, friction angle between 4-25o, OCR between 1-8, compression index between 0.25-1.65, and recompression index between 0.02-0.15. In this study a map containing soil parameters for the DKI Jakarta Region can be generated and analyzed. The results of the analysis shows a tendency to decrease in value with increasing depth in the parameters of specific gravity, dry density, water content, liquid limit, plastic limit, plasticity index, percentage of clay content, cohesion, friction angle, and OCR. Then there is a tendency for the value to increase with increasing depth on the specific gravity parameters, void ratio, compression index, recompression index, percentage of sand, and percentage of silt.
"
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Andika Sya`ban
"Terdapat banyak hasil penyelidikan tanah lapangan di DKI Jakarta yang tidak terpakai lagi setelah proyek pembangunan selesai. Sebagai bentuk pemanfaatan data hasil penyelidikan tanah di lapangan, pemetaan nilai N SPT serta qc dan FR CPT dilakukan untuk wilayah DKI Jakarta menggunakan data dari Laboratorium Mekanika Tanah, Universitas Indonesia. Pemetaan dilakukan untuk membuat prediksi hasil pengujian SPT maupun CPT sebagai data pembanding untuk penyelidikan tanah selanjutnya. Analisis geostatistik berupa kriging dilakukan untuk proses pemetaan. Sebelum dilakukan proses pemetaan, data hasil SPT dan CPT dikelompokkan berdasarkan kelompok kedalaman. Dengan bantuan aplikasi ArcGIS, hasil pemetaan prediksi nilai N SPT menunjukkan sebaran nilai yang membentuk kontur dari wilayah selatan menuju utara dengan nilai yang semakin meningkat ke arah selatan. Sedangkan pada peta prediksi nilai qc dan FR CPT ditemukan sebaran nilai yang cenderung homogen di setiap kedalaman yang ditinjau. Hasil prediksi nilai qc dan FR CPT juga digunakan untuk memetakan jenis tanah berdasarkan grafik Soil Behavior Type Robertson. Peta prediksi jenis tanah menunjukkan pada kedalaman 0-10 m akan ditemukan jenis tanah lempung (clay) dan campuran lanau-lempung (silt mixtures). Sedangkan pada kedalaman 10-20 m diprediksi akan ditemukan jenis tanah campuran pasir-lanau (sand mixtures).

There are many results of field investigations in DKI Jakarta that are not used anymore after the construction project is completed. As a form of utilizing data from soil investigations in the field, mapping of N SPT values as well as qc and FR CPT was conducted for the DKI Jakarta area using data from the Soil Mechanics Laboratory, University of Indonesia. Mapping is done to offer predictions of SPT and CPT test results as comparative data for further soil investigations. Geostatistical analysis in the form of kriging is carried out for the mapping process. Before the mapping process is carried out, the SPT and CPT result data are grouped by depth groups. With the help of the ArcGIS application, the results of mapping the predicted N SPT values shows the distribution of values that form the contours from the south to the north with increasing values to the south. Whereas on the prediction map, the values of qc and FR CPT were found to be uniformly distributed at each depth observed. In addition, the results of prediction of qc and FR CPT are used to map soil types based on Robertson's Soil Behavior Type Graph. A map of soil type predictions shows that at depths of 0-10 m, clay types and silt mixtures will be found. While at a depth of 10-20 m, it is predicted that sand mixtures will be found."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Mulia Akbar
"Tercatat data penyelidikan tanah telah dilakukan oleh Laboratorium Mekanika Tanah Departement Teknik Sipil Universitas Indonesia semenjak tahun 1981. Data penyelidikan tanah terbengkalai dan masih tersimpan dalam bentuk laporan tertulis. Berangkat dari hal tersebut, kemudian data diurutkan berdasarkan batas administrasi. Kemudian ditemui penyelidikan tanah berdomisili Jakarta terkumpul cukup banyak berisikan laporan penyelidikan adalah cone penetration test dan standard penetration test. Pada saat melakukan pengujian lapangan akurasi data menjadi menurun karena jumlah titik uji menjadi terbatas karena faktor biaya. Oleh karena itu diperlukan suatu referensi yang dapat memberikan gambaran kondisi tanah dibawah permukaan.
Dalam penelitian ini dilakukan pengelompokan tanah Jakarta berdasarkan data Laboratorium Mekanika Tanah DTS UI. Data diolah lalu didapatkan tren karakteristik tanah berdasarkan pengelompokan data uji CPT sehingga juga bisa didapatkan sebaran kedalaman tanah keras Jakarta. Untuk membantu analisis mekanika tanah dan teknik pondasi penelitian ini juga memberikan korelasi antara nilai qc dan N dari uji CPT dan SPT. Untuk area yang ditinjau yaitu sekitar Gambir, Kebagusan, Pondok Kelapa, dan Tanjung Priok menunjukkan kedalaman tanah keras sampai dengan 38,4 m, 16,8 m, 21 m, dan 18,6 m. Sedangkan korelasi qc-N yang didapatkan pada daerah Gambir qc=0,18 N dan pada daerah Tanjung Priok yaitu qc=0,18 N.

The soil investigation data that has been done by Soil Mechanics Laboratory Civil Engineering Department University of Indonesia was recorded since 1981. The data itself was abandoned and still kept as a hand-written form. Data was sorted based on their administrative boundary and turned out there were many investigation took place in Jakarta. The investigation based on the report were cone penetration test and standard penetration test. Designer needs references to represent the soil behavior below the surface.
In this study, the writer did some grouping for soil in Jakarta based on the data from Soil Mechanics Laboratory DTS UI. The data was then calculated and generated some soil characteristic trend from grouping of CPT data, so that it can obtained the range of depth of hard soil in Jakarta. Afterwards, to help analyzing the soil mechanics and the foundation engineering, this study also gives the correlation between qc and N from CPT and SPT. For areas investigated around Gambir, Kebagusan, Pondok Kelapa, and Tanjung Priok showed that the depth of hard soil were 38.4 m, 16.8 m, 21 m, and 18.6 m respectively. The correlation between qc-N in Gambir showed that qc=0.18 N whereas in Tanjung Priok qc=0.18N.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Miranti
"Pondasi tiang digunakan untuk menopang struktur. Di desain dapat menahan beban vertikal dan beban lateral. Tiang yang menerima pembebanan lateral merupakan permasalahan dalam rekayasa pondasi yang melibatkan interaksi tanah dan struktur. Akibat dari tiang yang terkena beban lateral dapat menimbulkan defleksi atau pergeseran tiang. Perencanaan awal pondasi diharapkan mendapatkan hasil yang tidak kurang atau lebih kapasitasnya dengan hasil pengujian pondasi langsung di lapangan. Metode pengujian kapasitas pondasi yaitu uji pembebanan lateral statik untuk mendapatkan defleksi lateral tiang. Penelitian ini menganalisis balik perhitungan dengan metode finite difference non-linier menggunakan aplikasi LPile 2019. Bertujuan mendapatkan parameter kurva p-y yang merepresentasikan hasil yang mendekati hasil pengujian pembebanan lateral di lapangan. Data penelitian dari 3 lokasi proyek dengan kondisi geoteknik tanah lunak cukup tebal. Sebanyak 20 tiang pancang uji dengan diameter tipikal 600 mm dan 1 tiang 500 mm. Data SPT sebanyak 8 titik yang digunakan sebagai parameter pemodelan. Pemodelan dilakukan dengan menginput properti tiang, lapisan tanah tiap kedalaman, parameter awal, dan beban lateral untuk mendapatkan defleksi lateral tiang. Hasil yang didapatkan menunjukkan 11 tiang pancang dapat menggunakan model soft clay, 8 tiang dapat menggunakan 2 model soft clay dan stiff clay with free water. Parameter kurva p-y dari hasil pemodelan sesuai dengan korelasi SPT sebagai referensi pada literatur yang digunakan. Perbaikan tanah pada lokasi proyek mempengaruhi nilai cu mengalami peningkatan.

Pile foundations are used to support structures. It is designed to withstand vertical loads and lateral loads. Piles that receive lateral loading are a problem in foundation engineering that involves the interaction of soil and structure. As a result og piles that are exposed to lateral loads can cause deflection or displacement of the pile. Design foundation is expected to get results that are not less or more capacity with the results of direct foundation testing in the field. The method of testing the foundation capacity is the static lateral loading test to obtain the lateral deflection of the pile. This research analyzes the back calculation with the non-liniear finite difference method using LPile 2019. The aim is to obtain p-y curve parameters that represent results that are close to the result of lateral loading test. Research data from 3 project sites with moderately thick soft soil geotechnical conditions. A total of 20 test piles with a typical diameter of 600 mm and 1 pile of 500 mm. SPT data of 8 points were used as modeling parameters. Modeling was performed by inputting pile properties, soil layers, initial parameters, and lateral loads to obtain pile lateral deflection. The results obtain show that 11 piles can use the soft clay model, 8 piles can use 2 models of soft clay and stiff clay with free water. The p-y curve parameters from the modeling results are in accordance with the SPT correlation as a reference in the literature used. Soil improvement at the project site affects the cu to increase."
Depok: Fakultas Teknik Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Nurmanda Ramadhani
"Pondasi tiang didesain berdasarkan karakteristik tanah terkait. Untuk mengetahui karakteristik tanah, maka dilakukan investigasi geoteknik. Salah satu investigasi geoteknik yang menjadi fokus adalah uji CPT (Cone Penetration Test). Meskipun sudah dilakukan investigasi, 'ketidakpastian' akan karakteristik tanah masih membayangi. Karena 'ketidakpastian' inilah, maka dilakukan uji pembebanan pondasi tiang.
Dari uji ini, akan dihasilkan (salah satunya) kurva siklik antara beban terhadap penurunan. Kurva ini akan menjadi acuan untuk uji balik yang dilakukan menggunakan program berbasis finite element analysis, yaitu PLAXIS- 2D. Uji balik dimaksudkan untuk menemukan korelasi nilai E (modulus elastis) tanah dan c (kohesi tanah) dengan nilai qc (tahanan konus) dari uji CPT.
Pemilihan lokasi untuk penelitian ini adalah pembangunan gedung world class university, Universitas Indonesia, Depok, Jawa Barat. Berdasarkan uji lapangan dan laboratorium, karakteristik tanah di lokasi ini didominasi oleh jenis lanau berlempung. Pada model PLAXIS-2D, nilai E dan c tanah pada tipe material Mohr-Coulomb diatur sampai memenuhi kriteria kecocokan kurva. Dari pemodelan ini, didapatkanlah korelasi nilai antara qc dengan nilai E dan c, sehingga kedepannya desain pondasi pada jenis tanah yang identik dengan lokasi penelitian dapat dilakukan lebih baik.

Pile foundation is designed based on the characteristics of the soil concerned. Geotechnical investigation was carried out to determine soil characteristic. CPT (Cone Penetration Test) is a geotechnical investigation that often done. Despite the investigation has been carried out, 'uncertainty' of soil characteristics is still exist.
Based on this thing, pile load testing needs to be done. One of the results of this test is a cyclic curve between load and settlement. This curve will be a reference to perform a back analysis using finite element based program, called PLAXIS-2D. The purpose of this analysis is to find correlation between E (elastic modulus), c (cohesion) and qc value from CPT test.
Site selection for this research is World Class University Building Project, Universitas Indonesia, Depok, West Java. During the construction, eight pile load testing were carried out. Based on field and laboratory testing, soil characteristic was dominated by Clayey-Silt Soil Type. In PLAXIS-2D model, E and c value of Mohr-Coulomb material type were adjusted until curve matching criteria successfully reached. Finally, the future design of pile foundation in soil types mentioned above can be more accurate.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S44757
UI - Skripsi Membership  Universitas Indonesia Library
cover
Kevin Yoseph Manuel
"Kuat geser tanah merupakan parameter yang sangat penting untuk melakukan analisis dan menyelesaikan masalah stabilitas tanah, dimana uji geser langsung sebagai salah satu jenis pengujian yang sering digunakan untuk menentukan nilai kuat geser tanah. Penelitian ini dilakukan untuk melihat pengaruh faktor kepadatan awal tanah melalui prosedur tampering, dan faktor jenis alat terhadap besarnya nilai ketidakpastian yang diperoleh. Selain itu, juga dilakukan dua metode perhitungan ketidakpastian pada uji geser langsung, yaitu dengan metode penurunan persamaan regresi linier, dan metode ketidakpastian gabungan. Dengan menggunakan sampel uji tanah berpasir, dihasilkan bahwa prosedur tampering yang ideal adalah dengan melakukan 15 kali tumbukan untuk setiap 1/3 lapisan untuk penggunaan alat direct shear manual karena menghasilkan nilai ketidakpastian sebesar ± 9.948° untuk nilai sudut geser dalam (φ), dan sebesar ± 6.174 kPa untuk kohesi (c). Nilai ketidakpastian ini lebih rendah dibandingkan dengan uji geser langsung dengan prosedur tampering 25 kali tumbukan untuk setiap 1/2 lapisan. Secara keseluruhan, pengujian dengan alat direct shear elektrik menghasilkan nilai ketidakpastian yang lebih kecil, yaitu sebesar ± 6.510° untuk nilai sudut geser dalam (φ), dan untuk kohesi (c) sebesar ± 4.545 kPa, jika dibandingkan dengan pengujian yang menggunakan alat direct shear manual.

Shear strength of soils is one of the essential parameters for analyzing and solving soil stability problems, and direct shear test is one type of test that is often used to determine the value of the soil shear strength. This research was conducted to see the effect of the initial density factor of the soil through the tampering procedure, and the different apparatus type factor on the magnitude of the obtained uncertainty value. In addition, two methods of calculating uncertainty in the direct shear test were carried out, namely the linear regression equation derivation method, and the combined uncertainty method. By using a sandy soil test sample, it was concluded that the ideal tampering procedure is to perform 15 collisions for every 1/3 layer for the use of a manual direct shear tool, because it produces an uncertainty value of ± 9.9485° for the value of the friction angle (φ) and for cohesion (c) of ± 6.1737 kPa. This value is lower compared to other tampering procedures. Over all the variety of the test that conducted, the test with an electric direct shear tool produces a smallest uncertainty value, which is ± 6.510° for the value of the internal shear angle (φ) and for cohesion (c) of ± 4.5453 kPa, when compared to the tests using a manual direct shear tool."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1993
S34287
UI - Skripsi Membership  Universitas Indonesia Library
cover
Saskia Nadilla
"ABSTRACT
Besar defleksi lateral pada pondasi tiang merupakan salah satu persyaratan desain pondasi tiang yang harus dipenuhi. Defleksi lateral aktual tiang yang terjadi diperoleh dari uji pembebanan lateral pada pondasi tiang dengan sistem pembebanan tertentu sesuai dengan ASTM D 3966-90. Perilaku antara tanah dan pondasi tiang akibat pembebanan lateral dimodelkan secara sederhana dengan model subgrade reaction dimana tanah disimulasikan sebagai kumpulan pegas dengan kekakuan lateral yang berbeda-beda. Untuk mengetahui hubungan antara kekakuan lateral pegas tanah dan nilai N-SPT, maka penulis melakukan perhitungan numerik dengan metode finite-element terhadap 34 data pembebanan lateral tiang dengan pembebanan siklik dan data bor dalam pada masing-masing lokasi uji pembebanan. Perhitungan numerik dilaksanakan untuk tiang tunggal dengan pembebanan lateral pada elevasi cut-off. Hasil yang diperoleh selanjutnya dibandingkan dengan grafik empiris hubungan kh koefisien tahanan lateral tanah dalam kg/cm3 dan nilai N-SPT berdasarkan Yokohama. Simulasi numerik yang dilakukan yaitu dengan menghitung nilai defleksi pada kepala tiang dimana tiang diasumsikan sebagai elemen balok dengan sifat linear elastis. Hasil simulasi numerik menunjukkan bahwa terdapat perbedaan korelasi antara studi kasus dengan 34 data tanah tersebut dengan grafik korelasi dari Yokohama. Selain itu, interpretasi dari hasil yang diperoleh menyatakan bahwa modulus subgrade reaction dipengaruhi oleh nilai N-SPT sepanjang kedalaman tiang dari cut-off level, diameter tiang, defleksi lateral aktual, dan besar beban lateral rencana. Namun, metode instalasi tiang tidak menunjukkan pengaruh yang signifikan terhadap hubungan antara modulus subgrade reaction dan nilai N-SPT.

ABSTRACT
The magnitude of lateral deflection is one of the requirement in designing pile foundation. The actual lateral deflection is obtained by lateral load test on pile foundation with certain loading system based on ASTM D 3966 90. The behavior between the soil and pile foundation is simply modeled by subgrade reaction model in which the soil is simulated as group of springs with different lateral stiffness. To find out the correlation between the spring lateral stiffness and N SPT value, the author perform numerical calculation based on finite element method of 34 cyclic lateral loading test and deep boring data at each loading test location. The calculation is carried out for single pile with lateral loading at cut off elevation. The results obtained are then compared with the emperical graph of correlation between kh lateral soil resistance cofficient in kg cm3 and N SPT value based on Yokohama. Numerical simulation is carried out by calculating the magnitude of lateral deflection at pile head where the pile is assumed as a beam element with elastic linear model. The results show that there are a difference in the correlation between 34 case studies modeled and Yokohama correlation. In addition, the result interpretation shows that subgrade reaction modulus is affected by N SPT value along the pile length from cut off level to pile toe, actual lateral deflection, and the magnitude of lateral load test. However, pile installation method does not show the significant impact to the correlation between modulus subgrade reaction modulus and N SPT value."
2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Alia Rizqika Putri
"Kebakaran lahan gambut yang semakin bertambah di Indonesia setiap tahunnya memicu ketertarikan dalam penelitian terkait karakteristik tanah gambut pada kemampuannya terkait penyerapan air kembali. Tanah gambut sejatinya memiliki sifat hidrofilik atau kemampuan dapat menyerap air dalam jumlah tinggi. Namun, ketika terkena panas, tanah gambut yang mengalami kekeringan akan berubah sifatnya menjadi hidrofobik karena adanya proses kimiawi. Hal ini terjadi karena tanah gambut memiliki sifat irreversible drying atau pengeringan yang tidak dapat dipulihkan apabila tanah gambut telah kering. Untuk membuktikan perubahan sifat yang dimiliki tanah gambut, dilakukan eksperimen dengan skala mikro (1 gram) menggunakan tanah gambut yang berasal dari dua pulau berbeda, Kalimantan dan Sumatra, yang dimasukkan ke dalam container alumunium dengan massa kurang lebih 1 gram dan dipanaskan dengan temperatur 100°C, 110°C, 120°C, 130°C, dan 140°C. Kemudian, sampel ini direndam di dalam air selama 30 menit dan ditiriskan selama 12 jam dalam keadaan terisolasi dari lingkungan luar sebelum dicek kandungan kelembabanya dengan moisture analyzer Shimadzu MOC63u selama 30 menit dengan temperatur 100°C. Selain itu, sampel tanah yang telah dikeringkan akan dilihat menggunakan mikroskop untuk mengetahui perubahan struktur ketika dikeringkan. Berdasarkan hasil eksperimen, didapat bahwa temperatur yang semakin tinggi mempengaruhi kemampuan tanah gambut dalam menyerap air kembali setelah dikeringkan. Selain itu, struktur tanah gambut yang telah dikeringkan juga berubah, yang tadinya pori-porinya saling tersambung menjadi terputus akibat terpapar panas. Hal ini menyebabkan tanah gambut menjadi memiliki sifat hidrofobik.

The increasing number of peatland fires in Indonesia each year has sparked interest in research related to the characteristics of peat soil in its ability to absorb water again. Peat soil actually has hydrophilic properties or the ability to absorb high amounts of water. However, when exposed to heat, peat soils that experience drought will change their properties to hydrophobic due to a chemical process. This happens because peat soil has irreversible drying properties that cannot be restored once the peat soil has dried. To prove the change in properties of peat soil, a micro-scale experiment (1 gram) was conducted using peat soil from two different islands, Kalimantan and Sumatra, which was put into an aluminum container with a mass of approximately 1 gram and heated to temperatures of 100°C, 110°C, 120°C, 130°C and 140°C. Then, these samples were soaked in water for 30 minutes and drained for 12 hours in isolation from the outside environment before checking the moisture content with a Shimadzu MOC63u moisture analyzer for 30 minutes at 100°C. In addition, the dried soil samples were examined using a microscope to determine the structural changes during drying. Based on the experimental results, it was found that higher temperatures affect the ability of peat soil to absorb water again after drying. In addition, the structure of the dried peat soil also changes, from being connected to each other to being disconnected due to exposure to heat. This causes the peat soil to become hydrophobic."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>