Zulfa Fuadi
"

Tujuan dari makalah ini adalah untuk menguji efisiensi energi melalui studi kinerja dalam siklus kompresi uap untuk auditorium di Universitas Indonesia menggunakan refrigeran alami R290. Pemasangan sistem chiller yang merupakan yang pertama di Indonesia dalam lembaga akademis sangat relevan mengingat minat dan penelitian mengenai penerapan sistem pendingin menggunakan ODP dan GWP yang relatif rendah sebagai alternatif untuk menggantikan HCFC-22. Ditemukan bahwa COP tertinggi selama 64% beban pendinginan parsial adalah 4,27 pada inlet air suhu adalah 8,9ºC. COP maksimum selama 75% muatan parsial adalah 5,25 pada inlet air suhu 6,8 ºC. Kapasitas pendinginan adalah 125,93 kW dan 148,39 kW masing-masing selama 64% dan 75%.


The purpose of this paper is to examine energy efficiency through the study of performance in vapour compression cycle for auditorium in University of Indonesia using natural refrigerant R290. The installation of the chiller system which is the first in Indonesia within academic institution is particularly relevant in light of the gaining interest and research regarding the implementation of refrigeration system utilizing relatively low ODP and GWP refrigerant as alternative to replace the refrigerant HCFC-22. It is found that the highest COP during 64% partial cooling load is 4.27 at temperature water inlet is 8.9ºC. The maximum COP during 75% partial load is 5.25 at temperature water inlet is 6,8 ºC. The cooling capacity are 125.93 kW and 148.39 kW during 64% and 75% load, respectively.

"
2019
T53332
UI - Tesis Membership  Universitas Indonesia Library
cover
Rachmah Rizky
"ABSTRAK
Naskah ini bertujuan untuk mengetahui performa sistem chiller pada pengoperasian ruang auditorium di Gallery Art Centre, Universitas Indonesia, sekaligus memverifikasi desain sistem. Instalasi sistem chiller berbasis refrigeran alami merupakan yang pertama untuk institusi perguruan tinggi di Indonesia yang juga merupakan bagian dari usaha green campus movement. Sistem pendinginan dengan memanfaatkan jenis refrigeran yang memiliki nilai ODP dan GWP rendah saat ini menarik perhatian dalam hal riset dan implementasi untuk menggantikan penggunan refrigeran R22. Dari hasil pengujian didapatkan COP rata-rata maksimum 4.27 pada kondisi pembebanan kosong, dan 5.25 saat pembebanan parsial. Kapasitas pendinginan maksimum kondisi tanpa pembebanan dan pembebanan parsial adalah masing-masing 125.93 kW dan 148.39kW, dengan konsumsi daya 30.06 kW and 30.12 kW.

ABSTRACT<>br>
The purpose of this paper is to examine energy efficiency through the study of performance in vapour compression cycle for auditorium in University of Indonesia using natural refrigerant R290. The installation of the chiller system which is the first in Indonesia within academic institution is particularly relevant in light of the gaining interest and research regarding the implementation of refrigeration system utilizing relatively low ODP and GWP refrigerant as alternative to replace the refrigerant R22. It is found that the maximum average COP is 4.27 at free load and 5.25 at partial load. The cooling capacity are 125.93 kW with energy consumption of 30.06 kW during free load and 148.39 kW with energy consumption of 30.12 kW at partial load, respectively."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Pamuntjak, Ilya Adzani
"Kenyamanan okupan dalam sebuah ruangan dikaitkan dengan kenyamanan termal, kesehatan, dan kontrol. Maka, kenyamanan termal adalah salah satu hal yang harus dicapaikan oleh sistem pendingin yang tersedia untuk sebuah ruangan indoor. Analisis kenyaman dilakukan dalam auditorium Makara UI Art Center yang menggunakan Chiller berbasis Refrigeran Alami R290. Pemasangan sistem pendingin ini adalah pertama di Indonesia untuk lembaga akademis sebagai kontribusi Universitas Indonesia pada Green Campus Movement. Maka, relevan untuk mengetahui kondisi kenyamanan termal dalam auditorium dalam kondisi pembebanan parsial dan beban kosong. Analisis dilakukan menggunakan temperature logger real-time. Sistem HVAC tidak dapat bereaksi jika diberikan lonjakan beban panas dan kelembaban yang bersifat tiba-tiba, dan sistem memerlukan waktu sekitar 60 menit untuk mengembalikan kelembaban auditorium kembali dalam zona nyaman. Untuk kondisi auditorium penuh, suhu rata-rata adalah 21.750C, dengan kelembaban rata-rata 57.84%, untuk auditorium kosong suhu rata-rata adalah 21.80 C, dan kelembaban rata-rata sebesar 53.14%, yang berarti kategori kenyamanan untuk auditorium adalah Cool Comfort. Perbedaan suhu simulasi dan data lapangan sebesar 12.7% atau +2.630C. Kecepatan udara di atas kepala menurut simulasi adalah 0.2 hingga 0.4 m/s, dimana titik-titik yang mencapai lebih dari 0.25 m/s dapat dikatakan tidak nyaman.

The purpose of this research is to analyze the dry-bulb temperature and humidity about thermal comfort according to SNI 03-6572-2001 standards for the Makara Art Center auditorium at the University of Indonesia using a chiller with the natural refrigerant R290. Thermal comfort is important for the well-being of occupants in the auditorium; therefore, the space must be cooled efficiently to ensure comfort. Data loggers are used to log dry-bulb temperature and humidity data in the auditorium and the results are compared to the SNI-03-6572-2001 indoor thermal comfort standards to create a conclusion of the thermal comfort inside the space. The HVAC system is not capable to detect and mitigate high humidity levels, and requires atleast 60 minutes to return the air humidity to comfortable levels. For full auditorium conditions, the average temperature is 21,750C, with an average humidity of 57.84%, for the auditorium the average temperature is 21.80C, and the average humidity is 53.14%, which means the auditorium can be put in the category of Cool Comfort. The difference in simulation temperature and field data is +12.7% or + 2.630C. The overhead air speed according to the simulation is 0.2 to 0.4 m / s, which means locations reaching more than 0.25 m/s can be considered uncomfortable."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Faiq Nurzaman
"

Kenyamanan termal adalah penilaian subjektif dari lingkungan termal yang cocok oleh pikiran individu. Standarisasi kenyamanan termal penting untuk menciptakan lingkungan dalam ruangan yang optimal. Oleh karena itu, beberapa standar telah digunakan selama beberapa dekade untuk mengukur kenyamanan termal berdasarkan suhu, kecepatan udara, dan kelembapan. Selain itu, panas ruangan dari penghuni dan barang lainnya juga berperan besar dalam mempengaruhi parameter tersebut. Ada dua pendekatan umum untuk mendapatkan variabel yang dibutuhkan dalam menentukan kenyamanan termal: audit ruangan dan simulasi. Audit ruangan adalah pendekatan yang paling nyata untuk mengukur parameter kenyamanan termal ruangan tertentu. Di sisi lain, pendekatan simulasi banyak digunakan dalam tahap desain sebuah bangunan. Untuk melakukan simulasi, setiap detail ruangan yang diukur harus diperhitungkan untuk melakukan pendekatan simulasi. Pada tesis ini parameter kenyamanan termal diukur di Auditorium Makara Art Center (MAC). Selain itu juga dibuat desain 3D auditorium yang sesuai dengan auditorium untuk mendapatkan akurasi simulasi dibandingkan dengan data sebenarnya. Untuk melakukan simulasi situasi yang paling mirip, beberapa skenario simulasi dengan bentuk diffuser dan parameter panas yang berbeda dilakukan menggunakan ANSYS Fluent sesuai dengan kondisi sebenarnya. Kondisi aktual suhu auditorium bervariasi dari 22,9 C hingga 24,1 C. Sedangkan suhu simulasi skenario keseluruhan menyimpang dari 0,1% hingga 52,63%. Simulasi kecepatan udara, di sisi lain, memiliki deviasi yang relatif lebih tinggi dibandingkan dengan simulasi suhu.

 


Thermal comfort is the subjective assessment of a suitable thermal environment by individual minds. Standardization for thermal comfort is important to create an optimal indoor environment. Therefore, several standards have been used over the decades to measure thermal comfort by temperature, air speed, and humidity. In additional, room heat from the occupants and other stuffs also plays a huge role in affecting those parameters. There are two general approaches to obtain the variables required in determining thermal comfort: room audit and simulation. Room audit is the most tangible approach to measure the thermal comfort parameters of a particular room. On the other hand, simulation approach is widely used in the design phase of a building. To conduct a simulation, every details of the measured room must be taken into account to conduct the simulation approach. In this thesis, thermal comfort parameters were measured in Makara Art Center (MAC) Auditorium. Additionally, a 3D design of the auditorium were also made in accordance to the auditorium to obtain the accuracy of simulation compared with the actual data. To conduct the most similar situation of the simulation, several simulation scenarios with different diffuser shape and heat parameters were conducted using ANSYS Fluent in accordance with the actual condition. The actual condition of the auditorium’s temperature varies from 22.9 C up to 24.1 C. Meanwhile, the simulation temperature of the overall scenarios deviates from 0.1% up to 52.63%. Air velocity simulation, on the other hand, has a relatively higher deviation compared to the temperature simulation. 

"
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Herfira Triana
"Secara global, konsumsi energi pada bangunan didominasi sebesar 55% oleh penggunaan energi listrik selama bangunan beroperasi. Sementara di Jakarta, sebesar 15 – 25% dari keseluruhan konsumsi energi digunakan untuk sistem pencahayaan buatan, berdasarkan riset tahun 2009. Untuk menurunkan konsumsi energi, serta mengurangi dampak negatif emisi pada lingkungan, diterapkan upaya peningkatan efisiensi energi. ASHRAE 189.1 merupakan standar yang disusun oleh sebuah asosiasi profesional Amerika, yang menjadi acuan teknis dunia untuk mendesain bangunan dengan penggunaan energi yang efisien. Melihat pencahayaan buatan pada bangunan seni multifungsi memegang peran yang penting, konsumsi energi pada tipe bangunan ini berpotensi didominasi oleh sistem pencahayaannya.
Penulisan ini mengkaji sistem pencahayaan buatan pada salah satu bangunan seni multifungsi, yaitu Makara Art Center Universitas Indonesia, untuk mengetahui apakah konsumsi energi sistem pencahayaan buatan pada bangunan telah efisien menurut standar ASHRAE 189.1. Kajian ini diawali dengan meninjau literatur yang berkaitan dengan bahasan, dilanjutkan dengan mengukur dan mengevaluasi iluminasi sistem pencahayaan bangunan studi kasus secara manual berdasarkan standar SNI 7062: 2019 serta dengan simulasi menggunakan perangkat lunak DIALux evo 10.1, yang kemudian disetarakan dengan standar ASHRAE 189.1. Hasil pengukuran 36 ruangan pada bangunan ini menunjukkan konsumsi energi untuk sistem pencahayaannya berlebih sebesar 0.17%. Berdasarkan 6 ruangan yang mengkonsumsi energi berlebih, terdapat 5 ruang yang lebih dominan menggunakan pencahayaan alami. Maka secara keseluruhan, konsumsi energi untuk sistem pencahayaan buatan Makara Art Center telah mendekati efisien, namun tetap dapat ditingkatkan kembali.

Globally, energy consumption in buildings is dominated by 55% use of electrical energy during building operations. Meanwhile in Jakarta, 15 – 25% of the total energy consumption is used for artificial lighting systems, based on research in 2009. To reduce energy consumption, and reduce the negative impact of emissions on the environment, efforts to improve energy efficiency are implemented. ASHRAE 189.1 is a standard compiled by an American professional association, which is a world’s technical reference for designing buildings with energy efficient use. Seeing that artificial lighting in multifunctional art buildings plays an important role, energy consumption in this building type has the potential to be dominated by the lighting system.
This paper examines the artificial lighting system in one of the multifunctional art buildings, namely Makara Art Center Universitas Indonesia, to find out whether the energy consumption of the artificial lighting system in the building is efficient according to ASHRAE 189.1 standards. This study begins by reviewing the literature related to the discussion, followed by measuring and evaluating the lighting system’s illumination of the case study building manually based on the SNI 7062: 2019 standard and by simulating it using the DIALux evo 10.1 software, which is then compared to the ASHRAE 189.1 standard. The measurement results of 36 rooms in this building show that the energy consumption for the lighting system is 0.17% excessive. Based on 6 rooms that consume excess energy, there are 5 rooms that use natural lighting more dominantly. So overall, the energy consumption of Makara Art Center's artificial lighting system is nearly efficient, but still can be increased.
"
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Gavin Cakraditya
"Tulisan dan penelitian ini dilakukan untuk melakukan perbandingan performa dari chiller dengan refrigerant R290 saat sebelum dan sesudah menggunakan sub-cooler/heat exchanger. Sehingga dapat memberikan perkiraan seberapa besar dampak penggunaan sub-cooler pada performa chiller. Penelitian ini dilakukan dalam rangka membantu pengembangan pemakaian chiller hidrokarbon di Indonesia, dimana minatnya sudah cukup tinggi dengan sifatnya refrigerant yang ramah lingkungan serta memiliki performa pendinginan yang lebih tinggi dari chiller dengan refrigerant R22 yang saat ini banyak digunakan. Melalui riset ini ditemukan bahwa penggunaan Sub-Cooler memberikan dampak kenaikan performa sebesar 6.9% pada beban pendinginan sedang, namun tidak memberikan perubahan signifikan pada performa saat beban pendinginan rendah.

The purpose of this research is to compare the performance of R290 hidrocarbon Chiller with sub-cooler and without sub-cooler, so that could give an estimation on how significant the impact made by sub-cooler in increasing chiller performance. This research also intended to helps the development of hydrocarbon chiller in Indonesia, which it's environmentally friendly and have higher performance than chiller with R22 as it's refrigerant. By doing this research, it was found that the use of sub-cooler when using it on medium cooling load operation could increase performance by 6.9%, but did not have significant effect in performance when using it on low cooling load operation."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Nadhira Izzatur Rahmani
"Dalam upaya memitigasi dampak bangunan terhadap lingkungan, prinsip green building telah diterapkan pada berbagai jenis bangunan. Salah satunya adalah bangunan dengan fungsi seni seperti art center. Art center merupakan bangunan multifungsi yang memfasilitasi berbagai kegiatan seni seperti musik, lukis, dan tari. Dengan begitu, kualitas akustik menjadi salah satu aspek yang penting terhadap keberlangsungan dan produktivitas kegiatan pada bangunan khususnya dengan fungsi seni.
Skripsi ini bertujuan untuk mengkaji kenyamanan akustik pada bangunan dengan fungsi seni yang menerapkan prinsip green building. Kajian ini diawali dengan studi literatur mengenai green building dan kenyamanan akustik. Studi kasus yang dikaji pada tulisan ini adalah Makara Art Center UI. Metode pengumpulan data dilakukan dengan cara pengukuran langsung dan penggunaan software simulasi Ease EVAC. Parameter yang dianalisis meliputi waktu dengung (RT), sound pressure level (SPL), noise criteria (NC), dan speech intelligibility (STI). Data yang didapatkan kemudian dibandingkan dengan standar ASHRAE 189.1 sebagai salah satu standar green building. Hasil studi kasus menunjukkan performa akustik masih belum seluruhnya memenuhi standar kenyamanan akustik ASHRAE 189.1. Secara umum, bangunan yang menerapkan prinsip green building, termasuk Makara Art Center, masih belum menyediakan kualitas akustik yang memuaskan.

In an effort to mitigate the impact of buildings on the environment, the principle of green buildings has been applied to various types of buildings. One of them is a building with an artistic function such as an art center. The art center is a multifunctional building that facilitates various artistic activities such as music, painting, and dance performances. That way, acoustic quality becomes one of the important aspects for the sustainability and productivity of activities in buildings, especially with the function of art.
This thesis aims to examine the acoustical comfort of an art center that applies the principles of green buildings. This research begins with a literature study on green building and acoustic comfort. The case study studied in this paper is the Makara Art Center UI. The method of data collection was carried out by direct measurement and the use of Ease EVAC simulation software. Parameters analyzed included reverberation time (RT), sound pressure level (SPL), noise criteria (NC), and speech intelligibility (STI). The data obtained are then compared with the ASHRAE 189.1 standard as one of the green building standards. The results of the case study show that the acoustic performance still does not fully meet ASHRAE 189.1 acoustical comfort standards. In general, buildings that apply green building principles, including the Makara Art Center, still do not provide satisfactory acoustic quality.
"
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Alman Luqmanulhakim
"Klinik Satelit Makara merupakan salah satu fasilitas milik Universitas Indonesia yang berfungsi sebagai sarana pelayanan kesehatan bagi mahasiswa, pegawai, atau masyarakat di sekitar Universitas Indonesia. Beragam kebutuhan pelayanan kesehatan membuat konsumsi listrik pada gedung klinik tidaklah sedikit. Maka dari itu diperlukan audit kualitas daya untuk mengetahui mutu kelistrikan gedung tersebut. Hasil audit kualitas daya menunjukkan terdapat tegangan maksimum berlebih (overvoltage) sebesar 232,44 Volt, melebihi SPLN I 1995 yang menetapkan batas tegangan maksimum sebesar +5% dari tegangan nominal atau sebesar 231 Volt. Pembebanan pada setiap fasanya juga tidak seimbang. Hal ini terlihat melalui pengukuran dimana arus rata-rata dan maksimum pada fasa S selalu cenderung lebih kecil dibandingkan fasa R dan T. Selain itu terjadi distorsi harmonik arus individu yang tidak sesuai standar. Hal ini ditunjukkan oleh nilai IHDi pada orde ke-3, orde ke-5, dan orde ke-7 melampaui batas maksimum IHDi yang ditentukan oleh IEEE 519-1992.

Makara Satellite Clinic is one of the facilities owned by the University of Indonesia that functions as a health service facility for students, employees, or communities around the University of Indonesia. A variety of health care needs make electricity consumption in clinical buildings not small. Therefore, a power quality audit is needed to determine the electrical quality of the building. The results of the power quality audit show that there is overvoltage, unbalanced loading in each phase, and current harmonic distortion that is not in accordance with the standard."
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Andika Ridwan Pratama
"Sistem tata udara mengonsumsi sebagian besar energi listrik pada gedung. Oleh karena itu, diperlukan upaya untuk meningkatkan efisiensi sistem tata udara untuk menghemat penggunaan energi. Salah satu komponen sistem tata udara yang mengonsumsi listrik besar adalah motor induksi pada pompa. Penggunaan pompa sistem katup untuk mengontrol debit aliran air tidaklah efisien. Namun, hal ini dapat dihindari dengan memanfaatkan Variable Speed Drive (“VSD”) yang dapat mengendalikan debit aliran dengan prinsip pengendalian kecepatan putar motor melalui perubahan frekuensi input. Penelitian ini melakukan analisis terhadap penggunaan konsumsi energi listrik pada sistem tata udara gedung beserta perbandingannya saat sebelum dan sesudah penerapan VSD untuk mengetahui besarnya penghematan energi.

Air conditioning system consumes most of the electrical energy in buildings. Therefore, further efforts are required to improve the efficiency of an air conditioning system to save electricity. One of the components of an air conditioning system that consumes a large amount of electricity is the induction motor on the pump. The use of a valve system pump to control the flow of water is inefficient. However, this can be avoided by utilizing a Variable Speed Drive (“VSD”) to control the flow rate which controls the rotational speed of the motor by changing the input frequency. This study aims to analyze the use of electrical energy consumption of an air conditioning system and its comparison before and after the application of VSD to determine the amount of energy savings."
Depok: Fakultas Teknik Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
"[Skripsi ini membahas mengenai penggunaan logo Makara Universitas Indonesia.
Logo Makara Universitas Indonesia dapat dikatakan sebagai suatu ciptaan dan dapat
dikatakan juga sebagai sebuah Merek. Hal ini penting untuk dibahas karena untuk
mengetahui mengenai satu objek dapat dilindungi oleh dua peraturan atau tidak.
Selain itu untuk menentukan penggunaan logo Makara tanpa izin dapat dikatakan
sebagai pelanggaran hak cipta atau merek. Untuk saat ini pengaturan mengenai hal
tersebut sudah ada tetapi masih belum jelas. Oleh karena itu penentuan mengenai satu
objek yang dilindungi dua peraturan hanya dapat ditentukan atas dasar doktrin dan
teori mengenai persinggungan antara hak cipta dan merek. Penelitian ini adalah
penelitian preskriptif yang memaparkan penggunaan doktrin dan teori sebagai
penunjang dan pelengkap ketentuan Undang-Undang Hak Cipta dan Undang-undang
Merek., This mini thesis focussed on issue of the use of the logo Makara Universitas
Indonesia. Logo Makara University Indonesia can be said as the creation and it can be
said also as a trademark. This is important to be discussed due to know about one
objects able to be protected by two regulations or not. In addition to determine the use
of logo Makara without permission could be said as a breach of copyright or
trademark. This arrangement on for the time it has been there but still not clear.
Hence the determination of one object that is only two rules can be determined on
base by doctrine and theory about crossing between copyright and trademark. This is
a prescriptive research that describes the doctrine and use of the theory as supporting
the act of copyright and act of trademark.]"
Universitas Indonesia, 2014
S57982
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>