Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 224593 dokumen yang sesuai dengan query
cover
Diana Mutia Pratiwi
"Ammonia merupakan senyawa polutan dengan ciri khas bau menyengat, serta dapat berbahaya ketika terpapar manusia. PT.PUSRI adalah produsen ammonia dan urea di Indonesia yang terletak berdekatan dengan permukiman warga, dimana gas ammonia seringkali terbebas diudara dan menyebabkan gangguan baik di dalam maupun disekitar lingkungan pabrik. Tujuan penelitian ini adalah mengevaluasi terbebasnya gas ammonia pada lingkungan sekitar pabrik ditinjau dari faktor penyebab, konsentrasi keluaran ammonia terbebas, dampak terhadap pekerja dan masyarakat, serta tindak penanggulangan yang dilakukan. Penelitian ini menggunakan metode sequential explanatory dengan menggabungkan data yang didapatkan dari observasi lapangan, wawancara key informan, kuesioner, dan literature review.
Berdasarkan penelitian, sekitar 95% faktor terbebasnya gas ammonia disebabkan permasalahan peralatan dengan nilai konsentrasi keluaran plant pada kondisi normal berada diantara 50-150 mg/Nm3 dan konsentrasi tertinggi dapat melebihi 435,79 mg/Nm3 pada saat pabrik mengalami gangguan. Dampak yang dialami pekerja dan masyarakat lebih kepada gangguan iritasi pada mata, hidung, dan saluran pernapasan yang bersifat sementara. Adapun tindak penanggulangan PT. PUSRI dalam bentuk Perbaikan proses dan pengembangan IPAL, pembangunan Green barrier, serta posko kesehatan sementara. Perlu dipertimbangkan penanggulangan yang diduga paling baik adalah dengan spraying dan pembangunan green barrier. Akan tetapi, masih terdapat beberapa kendala dan kelemahan dalam implementasinya, sehingga perlu dioptimalkan kembali.

Ammonia is a major pollutant compound with the characteristic of pungent odor, potentially harming when exposed to the human. PT. PUSRI is one of the Industries that produce ammonia and urea which is located adjacent to residential areas, where ammonia is often released in the air, causing disturbances both in and around the factory. This study focused on determining the factors causing the ammonia released, the concentration level of gas, its influence on the environment, along with the prevention attempted by the plant related to the case. This study use a quantitative approach with sequential explanatory method, by using literature study reinforced field observation, secondary data assisted by interviews and questionnaires on the workers and communities.
Based on the research, about 95% of the ammonia gas release is caused by equipment problems with the plant output concentration values under normal conditions between 50-150 mg/Nm3 and can exceed 435.79 mg/Nm3 when the plant is disrupted. The impact experienced by workers and the community is more on temporary irritation of the eyes, nose and respiratory tract. The countermeasures taken are the improvement of the process and development of WWTPs, the construction of Green barriers, and temporary health clinic. It should be considered that the best response is spraying and green barrier, but several weakness towards its implementation should be highlighted in order to achieve the best optimalization.
"
Depok: Sekolah Ilmu Lingkungan Universitas Indonesia, 2018
T51963
UI - Tesis Membership  Universitas Indonesia Library
cover
Fitri Dwirani
"PT. Pupuk Kujang (PTPK) merupakan salah satu industri penghasil pupuk atau produsen pupuk urea terbesar di Indonesia dengan kapasitas produksi terpasang sebesar 570.000 ton/tahun dan produk antara ammonia sebesar 330.000 ton/tahun serta produk sampingan yaitu nitrogen dan oksigen. Limbah yang berpotensi besar mencemari lingkungan pada pabrik PTPK adalah ammonia (NH3) karena dalam unit proses pembuatan pupuk urea pada PTPK, Limbah yang dikeluarkan banyak terkandung ammonia dalam bentuk gas. Apabila Limbah ini dibuang langsung ke udara ambien dan langsung dimanfaatkan oleh manusia untuk bernafas maka hal ini akan mempengaruhi kualitas udara ambien dan mengurangi derajat kesehatan manusia, tidak hanya akan memberikan potensi bahaya terhadap para pekerja, melainkan juga terhadap masyarakat yang tinggal di sekitar pabrik.
Gas ammonia adalah suatu gas yang tidak berwarna, dan menimbulkan bau yang sangat kuat. Dalam udara, ammonia dapat bertahan kurang lebih satu minggu. Gas ammonia terpajan melalui pernapasan dan dapat mengakibatkan iritasi yang kuat terhadap sistem pernapasan. Karena sifatnya yang iritasi, polutan ini dapat merangsang proses peradangan pada saluran pernapasan bagian atas yaitu saluran pemapasan mulai dari hidung hingga tenggorokan.
Terpajan gas ammonia pada tingkatan tertentu dapat menyebabkan gangguan pada fungsi paru-paru dan sensitivitas indera penciuman.
Berdasarkan pengamatan di lapangan, diketahui bau ammonia yang ditimbulkan dari kegiatan proses produksi masih sangat terasa pada siang dan malam hari baik itu di lingkungan kerja maupun di luar lingkungan kerja yaitu lingkungan permukiman masyarakat sekitar. Gangguan saluran pemapasan lebih banyak dikeluhkan oleh pekerja pabrik (terpajan ammonia risiko tinggi) dibandingkan pekerja non pabrik (terpajan ammonia risiko rendah). Sementara itu, di lingkungan permukiman masyarakat pun, sebagian besar merasa terganggu dengan bau dari gas ammonia tersebut.
Berdasarkan latar belakang tersebut, maka yang menjadi permasalahan dalam penelitian ini adalah 1) Adakah hubungan antara konsentrasi ammonia di kedua lingkungan kerja tersebut dengan gangguan kesehatan pekerja (gangguan saluran pernapasan), 2) Apakah terdapat hubungan yang nyata antara segmentasi demografi usia, lama tinggal, dan status pekerjaan dengan persepsi masyarakat mengenai kualitas udara yang terkontaminasi ammonia?
Hipotesis yang diajukan dalam penelitian ini adalah 1) Adanya hubungan yang signifikan antara konsentrasi ammonia di kedua lokasi tersebut di atas dengan gangguan kesehatan pekerja (gangguan saluran pemapasan), bahwa pekerja pads zona pemajanan konsentrasi ammonia risiko tinggi mempunyai kemungkinan relatip untuk menderita gangguan saluran pernapasan lebih besar daripada pekerja pada zona pemajanan dengan konsentrasi ammonia risiko rendah, 2) Terdapat persepsi yang berbeda secara nyata mengenai kualitas udara ammonia di lingkungan permukiman berdasarkan segementasi demografi usia, lama tinggal, dan status pekerjaan.
Variabel penelitian adalah konsentrasi gas ammonia, gangguan saluran pernapasan dan persepsi masyarakat. Sedangkan pengumpulan data dilakukan dengan menggunakan pengukuran langsung, kuesioner, wawancara dan observasi iangsung. Pemilihan lokasi penelitian berdasarkan rencana kelola lingkungan yang terdapat di PTPK, dan arch angin dominan. Besar sampel berdasarkan formulasi tertentu dan pemilihan responden berdasarkan purposive sampling untuk masyarakat, dan stratified random sampling untuk pekerja.
Analisis data dilakukan untuk membuktikan hipotesis yaitu analisis chi square test untuk membuktikan hipotesis pertama, dan analisis chi square test untuk membuktikan hipotesis kedua.
Analisis kualitas udara dilakukan pada dua zona pemajanan, yaitu lingkungan kerja terpajan konsentrasi ammonia risiko tinggi dan lingkungan kerja terpajan konsentrasi ammonia risiko rendah. Hasil analisis memperlihatkan pads zona pemajanan konsentrasi ammonia risiko tinggi, kualitas udara ammonia pada lingkungan kerja pabrik sebagian besar berada di atas nilai ambang batas yang ditetapkan (25 ppm) yaitu unit kerja urea sebesar 35,51 ppm; unit kerja ammonia sebesar 23,33 ppm; unit kerja utilitas sebesar 34,0 ppm; dan unit kerja bagging sebesar 35,07 ppm. Sedangkan pada zona pemajanan konsentrasi ammonia risiko rendah, kualitas udara ammonia di lingkungan kerja non pabrik berada di bawah nilai ambang batas yang ditetapkan, sebesar 0,102 pprn pada main office, dan sebesar 0,085 ppm pads daerah diktat dan construction office. Sementara itu kualitas udara ammonia untuk lingkungan permukiman masyarakat berada di bawah nilai ambang batas yang ditetapkan (2 ppm). Hasil kualitas udara ambien untuk ammonia memperlihatkan pada dusun Poponcol sebesar 0,013 ppm, dan dusun Pejaten sebesar 0,022 ppm.
Analisis perhitungan odds ratio dengan chi square test menunjukkan adanya kebermaknaan hubungan antara konsentrasi ammonia pada kedua zona terpajan ammonia risiko tinggi dan rendah dengan gangguan saluran pernapasan, batuk, asma, dan kesulitan bemapas (p-value <0,05). Sedangkan untuk gangguan saluran penapasan, batuk dengan dahak, tidak memiliki kebermaknaan hubungan (p-value>0,05). Hasil perhitungan memperlihatkan odds ratio batuk sebesar 2,1; odds ratio batuk dengan dahak sebesar 1,3; odds ratio asma sebesar 1,8; odds ratio kesulitan bemapas adalah 1,1.
Berdasarkan hasil analisis chi square test, diperoleh hasil yaitu tidak terdapat hubungan yang beimakna antara demografi usia, lama tinggal, dan status pekerjaan terhadap persepsi mengenai kualitas udara yang terkontaminasi ammonia.
Menjawab beberapa rumusan perrnasalahan di atas, beberapa kesimpulan dibuat sebagai berikut:
1. Konsentrasi ammonia di lingkungan kerja terpajan ammonia risiko tinggi, yaitu unit urea, unit utilitas, dan unit bagging, telah melampaui NAB (25 ppm), dan di unit ammonia berada sedikit di bawah NAB. Sementara itu konsentrasi ammonia di lingkungan kerja terpajan ammonia risiko rendah berada di bawah NAB (25 ppm).
2. Pekerja yang berada pada zona yang terpajan konsentrasi ammonia risiko tinggi, mempunyai risiko 2,1 kali lebih besar mengalami gangguan batuk; 1,8 kali lebih besar mengalami gangguan asma; 1,1 kali lebih besar mengalami gangguan kesulitan bemapas, dibandingkan pekerja yang berada pads zona yang terpajan konsentrasi ammonia risiko rendah.
3. Persepsi kualitas udara ammonia sangat menyengat tidak dipengaruhi oleh usia seseorang, lama tinggal dan status pekerjaan (bekerja dan tidak bekerja). Persepsi seseorang dapat dipengaruhi oleh faktor lain seperti pengetahuan internal seseorang, kebutuhan dan pengalaman.
Berdasarkan hasil dan pembahasan, saran yang dapat diberikan adalah:
1. Pencemaran udara ruangan pada unit bagging dapat dikurangi dengan membuat ventilasi yang sesuai dan memasang filter untuk menangkap polutan dari sumber dan polutan dari udara luar ruangan.
2. Diinstruksikan keharusan penggunaan APD bagi pekerja yang terpajan gas ammonia di lingkungan kerja terpajan ammonia risiko tinggi khususnya dalam penggunaan masker, baik itu masker with canister ataupun masker with catridges. Hal ini dikarenakan untuk melindungi pernapasan pars pekerja dari berbagai polutan, khususnya gas ammonia yang terhirup di lokasi kerja.

PT. Pupuk Kujang is the biggest one of fertilizers industry with production capacity 570.000 ton urea annually and 330.000 ton ammonia per year. Also PTPK produces side products, which are nitrogen and oxygen. Pollution that has become potential pollution to the environment at PTPK is ammonia, because in unit process of urea fertilizers making, the emission contain ammonia in gas phase. If the emission is directly exhausted to ambient air it continuously inhale by human being, it will effect to ambient air quality and human health, not only potentially effect to factory worker, but also effect to public community which are living near by industrial area.
Ammonia gas is a colorless gas with a strong odor. In the air, ammonia will last about one weeks. Ammonia gas exposed by inhalation and can cause strong irritation to respiratory system. This pollutant can irritate the inflammation process of upper respiratory, to the nose and throat. Exposure ammonia gas in certain level can effect to pulmonary function and odor sensitivity.
Based on field research, odor of ammonia which is caused by production process still strong in the morning and in the night time, both of workplace environment and public housing environment. The effect to respiratory symptoms are more complained by factory worker rather than non factory worker. Besides, most of the public feel annoyed by the strong odor of ammonia.
Research problem identified from the background are 1) Is there any association between ammonia concentration at factory workplace and office workplace to worker health symptoms (which is respiratory symptoms)?, 2) Is there any association between public perception to ammonia polluted air quality with demography segmentation, which are ages, length of stay, and occupational status.
Research hypothesis are following 1) There is association between ammonia concentration at workplace that exposures to high risk and exposures to low risk to health effect of factory worker. Most of the worker in high risk zone have more risk factor to get respiratory symptoms rather than the worker in low risk zone, 2) There are di ferences perception to air quality based on demography segmentation, which are ages, length of stay, and occupational status.
Research variable are a ammonia gas concentration, a respiratory symptoms, and community perception. Collecting data have been done by primary measurement, questionnaire, in deep interview, and field observation. Location were chosen based on environmental and management planning (rencana kelola lingkungan), from the dominant wind rose. Sample size were defined based on certain formulation. Respondent samples of public were chosen based on purposive sampling and respondent samples of worker were chosen based on stratified random sampling.
Data analyzed using chi square test analysis to verify the first hypothesis, and also chi square test analysis to verify the second hypothesis.
Air quality analysis have been done at two exposure zone, which are workplace exposure to high risk, and workplace exposure to low risk. Conclusion of analysis shows, at most of workplace exposure to high risk, ammonia air quality over threshold limit value (25 ppm) which are 35,61 ppm at urea plant unit, 23,33 ppm at ammonia plant unit, 34,0 ppm at utility plant unit, and 35,07 ppm at bagging plant unit. Meanwhile, at the workplace exposure to low risk, ammonia air quality below threshold limit value, which are 0,102 ppm at main office and 0,085 at diktat and construction office. At the public housing environment, ammonia air quality is in below threshold odor concentration (2 ppm). The result of ambient air quality for ammonia gas shows 0,013 ppm at dusun Poponcot and 0,022 ppm at dusun Pejaten.
Odds ratio analysis shows there are significantly association between concentration ammonia at both zone to respiratory symptoms, cough, asthma, and shortness of breath, which are odds ratio for cough 2,1; odds ratio for cough with phlegm 1,3; odds ratio for asthma attack 1,8; and odds ratio for shortness of breath 1,1. It means that worker in high risk zone have more risk factor to get respiratory symptoms rather than the worker in low risk zone.
Chi square test analysis shows there are not significantly association between demography segmentation of ages, length of stay, and occupational status to perception of ammonia contaminated air odor.
To answer the problems, there are several recommendation following:
1. Ammonia concentration at the workplace exposure to high risk such as urea plant, utility plant, and bagging plant are over the TLV, and at ammonia plant, the concentration is below the TLV. Meanwhile, ammonia concentration at the workplace exposure to low risk, which are main office and diktat are below the TLV.
2. The worker in high risk zone have risk probability to get symptoms of cough 2,1 times; asthma attack 1,8 times; and shortness of breath 1,1 times more larger than the worker in low risk zone.
3. The perception of smell a strong ammonia odor does not influenced by ages, length of stay, and occupational status of person. The perception could be influenced by other factor, such as know ledges of the people, needs of people, and experiences.
Based on result and analysis, there are several recommendation following:
1. Indoor air pollution at bagging plant unit cart minimized with make a appropriate ventilation and put in air filter to minimize the pollutant from the source and pollutant from the outside.
2. Good instruction for using personal protective equipment to the worker at workplace that exposure to high risk, such as masker with canister, or masker with cartridge, to prevent the worker respiratory from kind of pollutants especially inhaled ammonia gas at the workplace.
"
Program Pascasarjana Universitas Indonesia, 2004
T14902
UI - Tesis Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1993
S40658
UI - Skripsi Membership  Universitas Indonesia Library
cover
Diah Navianti
"Meningkatnya perkembangan Industri di Indonesia mengakibatkan terjadinya pencemaran Lingkungan di sekitamya. Adanya berita media massa tentang pencemaran lingkungan di sekitftr PT Pupuk Sriwijaya yang menycbabkan teijadinya penyakit infeksi saluran pemapasan pada penduduk di pemukiman sekitar industri tersebul.
Tujuan penelitian adalah untuk mcngetahui hubungan pemajanan ammonia dan PM", serta faktor risiko yang mempengaruhinya dengan kejadian gejala pcnyakit saluran pemapasan pada bayi dan balita di pemukiman sekitar PT pupuk Sriwijaya palembang tahun 2001.
Subyek pcnelitian adalah ibu-ibu yang memiliki bayi dan baiita (0 bulan-59 bulan). Didapatkan sebanyak 125 keluarga yang mcmiliki bayi dan balita secara random sampling yang tersebax dalam 3 kclurahan. Jenis penelitian bersifat deskriptif anaiitik dengan rancangan penelitian Cross-secrional.
Hasil penentuan kadar ammonia antara 246.75 pg/m3-1499 gym), sedangkan kadar P1\/110 antara 202.60 pg/m3-1281 ng/mi. Terdapat hubungan yang signifikan (p < 0.05) pemajanan ammonia dcngan kejadian gejala penyakit saluran pcmapasan pada bayi dan balita di pemukiman sekitar industri PT Pupuk Sriwidjaja. Ada hubungan dosis respons antara pemajanan ammonia dengan kejadian gejala penyakit saluran pemapasan pada bayi dan balita di pemukiman sckitar PT Pupuk Sriwidjaja Palembang
Pemajanan PM|o Yang tinggi pada bayi dan balita di pemukiman sekitar PT Pupuk Sriwidjaja akan meningkatkan risiko menderita gejala penyakit saluran pemapasan Dari model akhir didapat nilai OR = 1.1124 (95%CI=l.014-l.221), artinya setiap peningkatan 1 unit kadar PM 10 meningkatkan riaiko bayi dan balita rnenderita gejala penyakit saluran pemapasan sebcsar I 1.24%
Kesimpulan menunjukkan bahwa bayi dan balita yang terpajan dengan ammonia 2 652.50 pg/ma' mempunyai risiko menderita gcjala penyakit saluran pemapasan sebesar 9.508 kali dibandingkan dengan bayi dan balita yang terpajan ammonia < 652.50 pg,/ms setelah ciikontrol oleh variabcl variabel PMN, kepadatan hunian, perokok dalam rumah dan interaksi antara ammonia dengan PMN.
Saran kepada pihak PT Pupuk Sriwidjaja unmk tems memantad alat alat pengendaiian emisi gas maupun debu urea dan meningkatkan efisiensi dan efektifitas alat alat pengendalinya, sehingga dapat mengurangi pencemaran di sekitar industri tersebut.

Due to increasing industry expansion in Indonesia it alfect the environmental pollution around the industry. There was mass media regarding environmental pollution around PUSRI which result of acute respiratory infection symptoms of the local community around that lndustry.
The purpose of -this study is to find out the relationship between expo: ure ammonia and PMN , as well as risk factor which influence with the condition acute respiratory infection symptoms at babies and children living around at PT Pupuk Sriwidjaja in 2001.
Subyect of this study are mothers who has babies and children ranging from 0 to 59 months. We found out that around l25 families who has babies and children as sampling random from 3. The methode of this study is descriptive analytic with cross sectional study designed.
The result of concentrate ammonia between 246.75 ug/m3-1499 ug/m3. And actual PMN, consentrate between 202.60 ug/m3-128| pg/rn3.There is significant relationship (p<0_05) between exposure ammonia and PM", with condition acute respiratory infection symptoms at babies and children living around at PT Pupuk Sriwidjaja Palembang There are linked dose respons between exposure ammonia with acute respiratory infection symptoms at babies and children living around at P'I` pupuk Sriwidjaja.
High exposure of PM", at the babies and children around PT Pusn area will raise from the risk acute respiratory infection symptoms. From the last model, it found out the value of OR equal to 1.1124 (95%CI = l.0l4-1221), meaning every raise per l unit PM10 will be raised the risk of babies and children for l 1.24 %.
Conclusion indicates that babies and children who has exposured with ammonia 2 652.50 ug/m3 has risk factor of the acute respiratory infection symptoms 9.5! times compare with babies and children exposured by ammonia < 652.50 ug/m3, after being adjusted by variables PM io, smoker inside the house, density of population and interact between ammonia and PM iq.
Suggestion to PT Pupuk Sriwidjaja to constantly measure all the control gas emission and dust urea equipment and to raise eiiiciency and effectiveness ofthe control equipment so that it could reduce pollution around the industry.
"
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2002
T5086
UI - Tesis Membership  Universitas Indonesia Library
cover
Simanjuntak, Charles J.
"Sejumlah tenaga kerja yang selama paling sedikit 5½ jam sehari, 5 hari seminggu dan telah berlangsung hingga 4 tahun, telah menghirup udara lingkungan kerja yang mengandung gas ammonia. Keadaan seperti inilah yang telah diamati oleh peneliti di pabrik ammonia urea dari perusahaan PT. PUPUK KALTIM yang berlokasi di Bontang, Propinsi Kalimantan Timur. Hal yang sama dialami oleh karyawan lain di pabrik sejenis dengan kadar dan waktu pemaparan yang berbeda-beda. Para pekerja gelisah akan kemungkinan rusaknya paru mereka, sehingga sering mengganggu pikiran mereka sewaktu melaksanakan tugasnya. Walaupun lama kelamaan dengan berjalannya waktu, para pekerja telah "menerima" lingkungan kerja yang demikian, namun kegelisahan itu sewaktu-waktu dapat muncul kembali.
Kecelakaan akibat tumpahnya ammonia cair atau bocornya gas ammonia telah pernah dilaporkan, namun akibat lebih lanjut dari peristiwa itu belum pernah dilaporkan. Gangguan organ pernafasan akibat gas ammonia lingkungan kerja sangat sedikit didokumentasikan dan penelitian ke arah ini masih jarang. Walaupun para ahli dan pengawas kesehatan kerja dapat menetapkan Nilai Ambang Batas (NAB) secara umum, namun disadari bahwa NAB tersebut dari waktu ke waktu selalu ditinjau kembali. Ini disebabkan pengertian gangguan kesehatan semakin sensitif dan spesifik sebagai konsekuensi berkembangnya tuntutan "sejahtera" dari manusia beradab.
Untuk itu perlu diselidiki bagaimana hubungan antara pemaparan gas ammonia dan kesehatan tubuh tenaga kerja. Untuk kesempatan kali ini penulis meneliti hubungannya dengan fungsi paru. Disadari bahwa kebanyakan tenaga kerja Indonesia umumnya dan tenaga kerja pabrik ini khususnya, belum dapat lepas dari kebiasaan merokok. Untuk mendapatkan pengaruh gas ammonia yang "murni", maka para perokok
Untuk lebih memastikan tingkat kaitan antara udara lingkungan kerja yang mengandung gas ammonia dan fungsi paru maka perlu dilakukan penyelidikan serupa di pabrik sejenis di luar pabrik PT. PUPUK KALTIM yaitu pabrik PT. PUPUK KUJANG. Keterbatasan waktu menyebabkan pengumpulan data dicukupkan hanya pada kedua perusahaan ini. Berbagai alat pengukur telah dipelajari. Dari alat-alat yang tersedia, selanjutnya dipilih yang terbaik yaitu spektrofotometer untuk analisis gas ammonia dan spiro meter untuk mengukur fungsi paru."
Jakarta: Fakultas Kedokteran Universitas Indonesia, 1990
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
cover
Resta Juliansyah
"Hibrida zeolit ZSM-5 dan SOD telah berhasil dibuat di atas permukaan glassy carbon. Pertama?tama zeolit ZSM-5 disintesis dari koloid gel ZSM-5 dengan menggunakan dua jenis template atau yang dikenal dengan sintesis double template dan metode hidrotermal. Selanjutnya zeolit SOD dilapisi di atas permukaan ZSM-5 dengan menggunakan metode seeding menggunakan koloid gel seed dan larutan prekursor. Hasil XRD menunjukkan bahwa zeolit yang dihasilkan merupakan zeolit ZSM-5 dan SOD. Diperkuat dengan hasil SEM dan EDS yang memperlihatkan rasio Si/Al pada ZSM-5 sebesar 2,5 dan pada SOD sebesar 1,3. Untuk melihat pengaruh gas amonia terhadap hibrida zeolit dihitung menggunakan alat impedance analyzer yang dapat dilihat pada frekuensi sebesar 20 Hz - 20 kHz didapat rentang deteksi dari 0 ppm ? 100 ppm serta dihitung hubungan antara konsentrasi dengan perubahan nilai impedansi pada frekuensi 100 Hz dan diperoleh nilai r2 sebesar 0,9376.

Hybrid zeolite ZSM-5 and SOD have been successfully fabricated on the surface of glassy carbon. First,zeolite ZSM-5 synthesized from colloidal gels ZSM-5 by using two types of templates, known as double-template synthesis and hydrothermal method. Furthermore, SOD zeolite coated on the surface of ZSM-5 by using a seeding method using seed and colloidal gel precursor solution. XRD results showed that zeolite ZSM-5 and SOD has been obtained. Reinforced with SEM and EDS results showing the ratio of Si / Al in the ZSM-5 at 2.5 and the SOD of 1.3. To see the effect of the hybrid zeolite ammonia gas is calculated using the impedance analyzer tool which can be seen at a frequency of 20 Hz until 20 kHz obtained the detection range of 0 ppm until 100 ppm and calculated the relation between the concentration of the change in value of the impedance at a frequency of 100 Hz and obtained values of r2 of 0.9376.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2014
S53555
UI - Skripsi Membership  Universitas Indonesia Library
cover
Novrikasari
"Konsep penanggulangan bencana saat ini adalah paradigma pengurangan risiko.Setiap individu, masyarakat di daerah diperkenalkan dengan berbagai ancaman (hazards) dan kerentanan (vulnerability) yang dimiliki, serta meningkatkan kemampuan (capacity) masyarakat dalam menghadapi setiap ancaman. Sehingga studi ini bertujuan mengkaji model pengendalian risiko dispersi gas amonia.
Disain studi adalah cross sectional. Analisis model pengukuran dan struktural menggunakan comfirmatory factor analysis (CFA). Nilai validitas dan reliabilitas hasil uji kesesuaian/Goodness of Fit (GOF) adalah good fit untuk konstruk dari model.Kuesioner disebarkan secara cluster, terdapat 626 responden (area risiko 0- 2600 meter). Dibagi menjadi 293 responden pada zona dalam (area risiko 0-1300 meter) dan 333 responden zona luar (area risiko >1300-2600 meter).
Model pengukuran menghasilkan 5 variabel eksogen (kondisi lingkungan, sosial, ekonomi, biologi dan kapasitas) yang saling berhubungan langsung membentuk variabel endogen risiko dispersi gas amonia. Faktor kondisi lingkungan terdiri dari zona bahaya dan jarak rumah ke jalan raya.Faktor sosial yaitu pelatihan dan pekerjaan.Faktor ekonomi yaitu kecukupan akomodasi, pendapatan, asuransi dan pendidikan.Faktor kapasitas yaitu pengetahuan tentang bahaya, pengetahuan tentang peringatan dini, pengetahuan tentang evakuasi dan perilaku tanggap darurat. Faktor biologi yaitu usia> 65 tahun, anggota keluarga dengan penyakit kronis dan anggota keluarga berkebutuhan khusus. Risiko dispersi gas amonia pada rumah tangga area risiko 0-2600 meter ada pengaruh kontribusi dari 47% faktor sosial, 37% faktor ekonomi, 29% faktor kapasitas dan 9% faktor kondisi. Risiko dispersi gas amonia zona dalam (area risiko 0-1300 meter ada pengaruh kontribusi darifaktor sosialberkontribusi 63%, faktor ekonomi 64%, faktor kapasitas 57% dan biologi 2,3%. Selanjutnya risiko dispersi gas amonia pada rumah tangga area risiko >1300-2600 meter ada pengaruh kontribusi dari 2 (dua) faktor yaitu faktor kondisi 99% dan faktor kapasitas (12%).
Penelitian ini menyimpulkan model risiko dispersi gas amonia dalam penelitian ini menunjukkan faktor yang berkontribusi membentuk risiko dispersi gas amonia sehingga dapat menjadi upaya pengendalian dengan memperhatikan faktor yang berkontribusi tersebut. Rekomendasi kepada Pemerintah Daerah untuk menetapkan peta rawan bencana menjadi peraturan daerah yang berkekuatan hukum dan pemberlakuan peraturan tentang tata ruang (daerah pemukiman), standar keselamatan (pemantauan penggunaan teknologi) dan penerapan sanksi terhadap pelanggar. Mengkoordinasi antara Satuan Kerja Perangkat Daerah (SKPD), Dinas Pemadam Kebakaran/ Badan Penanggulangan Bencana Daerah (BPBD), dan dinas terkait untuk evakuasi (akomodasi), kelancaran akses jalur evakuasi. Menyelenggarakan sosialisasi, pendidikan dan pelatihan mengenai kesiapsiagaan bencana dispersi gas amonia kepada masyarakat melalui perkumpulan/organisasi di masyarakat.
Rekomendasi kepada perusahaan antara lain : Membuat peta rawan bencana dan Emergency Respon Plan (ERP) baik internal maupun eksternal; Melakukan perawatan dengan inspeksi rutin berbasis risiko untuk memastikan kehandalan peralatan sistem pendingin amonia; Semua pekerja dalam operasional tangki sistem pendingin amonia selalu dilakukan dengan mengikuti Standard Operating Procedure (SOP), peraturan keselamatan, audit keselamatan; Mengingat sifat gas amonia yang tidak berwarna tetapi sangat beracun serta luasan area risiko yang berdampak perlu adanya sensor untuk gas amonia sebagai alat ukur dan monitoring. Selanjutnya rekomendasi kepada masyarakat agar mengembangkan dan berperan aktif dalam desa siaga bencana (kesiapsiagaan bencana berbasis masyarakat).

The concept of disaster management nowadays is risk reductionsparadigm. Each individual, residents are introduced to various threats and vulnerabilities owned, as well as increased capacity in facing any threats. This study aims to assess the risk control model of ammonia gas dispersion.
The design study was cross sectional using confirmatory factor analysis (CFA) as the measurement model and structural analysis. Validity and reliability value for Goodness of Fit (GOF) test is good fit for construct of the model. Questionnaires were distributed by cluster, there were626 respondents (risk area 0-2600 meters) divided into 293 and 333 respondents in the inner and outer zones (risk area >1300-2600 meters).
Measurement model produces 5 directly interconnected exogenous variables (environmental, social, economic, biological and capacity condition) to form an endogenous variable risk of ammonia gas dispersion. Environmental conditions consist of danger zone and distance from home to road. Social factors consist of training and job. Economic factors consist of accommodation, salary, assurance and education. Capacity factors consist of hazard knowledge, early warning knowledge, evacuation knowledge and emergency response behavior.Biological factors consist of age >65 year old and family member with chronic disease and disability. The model goodness of fit test result was compatible for RMSEA, CFI, IFI, CN, SRMR, GFI and AGFI. It indicates that the models can describe the ammonia gas dispersion riskformed factors. Social factorscontribute61% of thetotalrisk ofammoniagasdispersion, related toeconomic factors(42%), capacityfactor(36%)andconditionfactor(5.7%). Riskdispersionof ammoniagasin thezoneindicateseconomic factorsaccounted for64% of thetotalrisk ofammoniagas dispersionincludingsocial(63%), capacity(57%) andbiology(2.3%). While theouterzone ofthe conditionfactor(99%) to be importantin the risk ofammoniagasdispersionandcapacity factor(1%).
This study concludes dispersion risk modelsof ammonia gas in this study indicate risk factors that contribute to form ammonia gas dispersion to be a control effort by noticing the factors that contribute as following; recommend to the Regional Government to establish hazard maps into a legally binding regional regulations and enforcement of regulations on spatial (residential areas), safety standards (monitoring the use of technology) and the imposition of sanctions against offenders. Coordinate between work units (SKPD), Fire Department / Agency for Disaster Management (BPBD), and related agencies for evacuation (accommodation), the smooth evacuation route access. Organize socialization, education and training on disaster preparedness ammonia gas dispersion to the public through associations / organizations in the community.
Recommendations to the company include: Creating a hazard map and Emergency Response Plan (ERP) both internally and externally; Perform routine maintenance with risk- based inspections to ensure equipment reliability ammonia refrigeration systems; All workers in the operational tank ammonia cooling system is always done by following the Standard Operating Procedure (SOP), safety rules, safety audits; Given the nature of ammonia gas that is colorless but highly toxic as well as the extent of the risk areas that impact the need for a sensor for ammonia gas as a means of measuring and monitoring. Further recommendations to the community are to develop and play an active role in disaster preparedness village (community-based disaster preparedness).
"
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2015
D-Pdf
UI - Disertasi Membership  Universitas Indonesia Library
cover
Adianto Subroto
"Pada penelitian ini digunakan H-Zeolit hasil preparasi menggunakan metode pertukaran ion dengan NH4NO3. H-Zeolit ini dipakai untuk mengadsorpsi gas NH; dalam campurannya dengan gas Nitrogen secara siklus yang terdiri atas tahap adsorpsi dan regenerasi. Uji pengaruh suhu terhadap kapasitas adsorpsi dilakukan pada rentang suhu 100-350°C. Uji stabilitas dilakukan sebanyak 2,5 siklus dengan adsorpsi pada suhu 125°C dan regenerasi pada suhu 475°C. Untuk uji pengaruh air terhadap kapasitas adsorpsi, maka HZ dijenuhkan dengan air sebelum digunakan untuk mengadsorpsi NH; pada suhu 125 dan 100°C. Pada penentuan laju adsorpsi, dilakukan adsorpsi dengan variasi konsentrasi umpan pada temperatur adsorpsi 100°C.
Hasil penelitian menunjukkan kapasitas adsorpsi NH3, pada temperatur operasi 100, 125, 200, 300 dan 350°C adalah sebesar 1.72, 1.35, 0.90, 0.47 dan 0.33 mmol/gr H-Zeolit. Kapasitas adsorpsi pada suhu rendah lebih besar dibandingkan suhu yang lebih tinggi karena terjadi adsorpsi fisika dan kimia secara simultan.
Dari basil uji stabilitas diperoleh kapasitas adsorpsi siklus ke 1, 2, 3 secara berturut-turut adalah 1.35, 1.26 dan 1.16 mmol NH3/gr HZ. Kapasitas adsorpsi karena adanya pengaruh air untuk temperatur operasi 100 dan 125°C adalah sebesar 1.56 dan 1.26 mmol NH3/gr HZ atau mengalami penurunan sekitar 20% dibandingkan dengan kapasitas 'fresh' HZ. Persamaan laju awal adsorpsi pada temperatur 100°C dan W/F=0.03 g.menit/ml adalah r = 1.06x10-2 [NH3]0.82 mol NH3/g HZ. menit.
Studi kasus untuk konsentrasi gas buang NH3 3000 ppm dengan Iaju total gas buang 12 ton/jam., membutuhkan HZ sebanyak 11.98 ton atau 21.89 m3 dengan waktu tahap adsorpsi 2 jam 30 menit dan regenerasi 40 menit. Temperatur operasi yang digunakan adalah 125 ºC, yang merupakan temperatur keluaran stripper dan untuk meregenerasinya digunakan steam HP pada temperatur 475°C."
Depok: Fakultas Teknik Universitas Indonesia, 1997
S48934
UI - Skripsi Membership  Universitas Indonesia Library
cover
I Gusti Agung Ayu Desy Wulandari
"Sistem pendingin dengan tenaga surya adalah teknologi dengan peluang yang besar dalam upaya mengurangi biaya terutama pada pemakaian listrik, dampak terhadap lingkungan, dan emisi gas rumah kaca, salah satunya adalah teknologi absorption chiller dengan bantuan energi surya untuk mendukung kerja pada komponen generator. Pada penelitian ini, simulasi termodinamika dilakukan sebagai tahapan awal desain sistem single-effect ammonia-water absorption chiller yang dimodelkan menggunakan media pendingin udara lingkungan (air-cooled) dan sumber panas berasal dari sistem kolektor termal surya, disesuaikan dengan aplikasi rumah tangga (residential) berkapasitas pendinginan rendah di negara beriklim tropis Indonesia. Kinerja sistem berupa nilai COP yang diperoleh dari simulasi sistem berdasarkan parameter input yang telah disesuaikan dengan batasan permasalahan penelitian adalah sebesar 0.554. Karakterisasi yang dilakukan terhadap dua parameter input pada sistem menunjukkan bahwa kenaikan temperatur kondensasi meningkatkan temperatur outlet generator, namun menurunkan nilai COP sistem. Hal ini bertentangan dengan pengaruh temperatur evaporasi yang menurunkan temperatur outlet generator, namun COP sistem menjadi meningkat. Sedangkan peningkatan kadar air pada solution menurunkan COP sistem. Jumlah solar collector dengan tipe ETC yang diperlukan untuk sistem single-effect ammonia-water absorption chiller adalah sebanyak lima buah kolektor dengan rangkaian seri, dan dengan kapasitas rata-rata masing-masing kolektor sebesar 1,52 kW.

Solar-powered cooling system is a technology with great opportunities to reduce operation costs, especially on electricity consumption, impact on the environment, and greenhouse gas emissions, one of which is by the use of absorption chiller technology with the help of solar energy to support the work of generator components. In this study, the thermodynamic simulation was carried out as an early stage in designing a single-effect ammonia-water absorption chiller system which is modeled using air-cooled system and the heat source comes from solar thermal collector system, adapted for residential applications with low cooling capacity in the tropical country of Indonesia. System performance in the form of COP value obtained from the system simulation based on input parameters that have been adjusted to the limits of the research problem is 0.554. System characterization was carried out on the two input parameters in the system shows that the increase in condensation temperature increases the generator outlet temperature but decreases the COP value of the system. This is contradicting to the effect of the evaporation temperature which decreases the generator outlet temperature, but the COP system increases. Meanwhile, increasing the water content of the solution decreases the COP of the system. The number of solar collectors with ETC type required for the single-effect ammonia-water absorption chiller system is five collectors in series arrangement, with an average collector capacity of 1.52 kW."
Depok: Fakultas Teknik Universitas Indonesia, 2021
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>