Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 101106 dokumen yang sesuai dengan query
cover
Siregar, Leonardus
"The electric power is something that is very important and widely used in supporting human life, but the power is also very dangerous to human safety itself. Low voltage 220 V is part of the electric power distribution system. On this channel it is possible short circuit due to installation errors. Disturbances in this system becomes a possibility of being harmful to humans, because the electric current can make men swoon even death. So that people can avoid the danger that occurs, then the system installation households should be connected to the ground through a prisoner whose price is relatively low. Of the prisoners is to be investigated in the installation of existing homes in the city of Medan.
"
Universitas HKBP Nonmensen, 2017
050 VISI 25:2 (2017)
Artikel Jurnal  Universitas Indonesia Library
cover
Raden Fadhil Rafii Saputro
"Banyak peralatan rumah tangga saat ini sudah menerapkan teknologi switch-mode power supply (SMPS) dan inverter yang dapat meningkatkan efisiensi energi. Namun penggunaan teknologi tersebut dapat membangkitkan disturbance pada rentang frekuensi 9-150 kHz akibat frekuensi switching yang tinggi. Selain itu, penurunan emisi pada rentang frekuensi rendah atau harmonik klasik dengan rangkaian filter, menjadi salah satu penyebab lainnya dalam meningkatnya emisi pada rentang frekuensi tinggi. Tegangan suplai utama pada jaringan tegangan rendah selalu bervariasi nilainya setiap waktu. Variasi tegangan suplai yang terjadi secara aktual dapat mempengaruhi disturbance yang dibangkitkan oleh peralatan rumah tangga pada rentang frekuensi 9-150 kHz.
Penelitian ini fokus pada pencarian karakteristik disturbance peralatan rumah tangga dan pengaruh disturbance yang dibangkitkan terhadap variasi tegangan suplai pada rentang frekuensi 9-150 kHz. Peralatan rumah tangga yang digunakan adalah AC inverter, AC non-inverter, kulkas inverter, kulkas non-inverter, kompor induksi, lampu CFL, lampu LED, personal komputer, dan vacuum cleaner. Dalam melakukan pencarian karakteristik disturbance peralatan rumah tangga, digunakan decoupling network untuk menurunkan tegangan jatuh pada impedansi internal peralatan rumah tangga dan membatasi disturbance dari suplai masuk saat dilakukan pengukuran.
Pengukuran disturbance dilakukan dengan menggunakan osiloskop differensial Picoscope 3425. Analisis karakteristik disturbance dilakukan dalam domain frekuensi dengan menggunakan Fast Fourier Transform (FFT). Pencarian karakteristik disturbance dilakukan pada tiga variasi waktu (pagi, siang, dan malam). Dari hasil pengukuran menunjukan disturbance tertinggi dihasilkan oleh vacuum cleaner sebesar 5,085 V pada frekuensi 9,8 kHz dan disturbance terendah dihasilkan oleh lampu LED Panasonic sebesar 16,62 mV pada frekuensi 64,4 kHz. Perubahan disturbance tertinggi yang dibangkitkan oleh peralatan rumah tangga terhadap variasi tegangan suplai terjadi pada kulkas inverter, dengan perubahan disturbance mencapai 71,79% dan yang terendah terjadi pada lampu CFL Philips sebesar 11,6%.

Many household appliances are now implementing switch-mode power supply (SMPS) and inverter technologies that can improve energy efficiency. But the use of these technologies may generate disturbances in the frequency range within 9-150 kHz due to high switching-frequency. In addition, decreasing emissions in the low frequency range or classical harmonics with filter circuits, is one of the other causes in increasing emissions in the high frequency range. The main supply voltage at low voltage networks always varies in time. Variations in actual supply voltage can affect the disturbance generated by household appliances at a frequency range within 9-150 kHz.
This study focused on the search for characteristics of disturbance in household appliances and the disturbance generated by variations of actual supply voltage in the frequency range within 9-150 kHz. The household appliances under test are inverter air conditioner, non-inverter air conditioner, inverter refrigerator, non-inverter refrigerator, induction cooker, CFLs lamps, LEDs lamps, personal computer, and vacuum cleaner. The actual disturbance characteristics of household appliances can be measured by installing decoupling network which used to reduce the voltage drop in the internal impedance of household appliances and limit the disturbance from incoming supply when measured.
The disturbance is measured by using Picoscope 3425 differential oscilloscope. The characteristics of disturbance is analyzed in the frequency domain using Fast Fourier Transform (FFT) and measured on three variations of time (morning, afternoon and evening). The measurement results shows, the highest disturbance is generated by a vacuum cleaner of 5,085 V at a frequency of 9,8 kHz and the lowest disturbance is generated by Panasonic LED lamps of 16,62 mV at a frequency of 64,4 kHz. The highest variance of disturbance generated by household appliances affected by variations in supply voltage is inverter refrigerator, with variance of disturbance reaches 71,79% and the lowest is Philips CFL lamps reaches 11,6%.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Reza Insan Meidiansyah
"Arus inrush merupakan salah satu fenomena yang terjadi pada sistem tenaga listrik khusunya pada transformator. Arus ini dapat menyebabkan kesalahan kerja proteksi pada sistem sehingga akan mengganggu keandalan sistem tenaga listrik. Arus inrush berbeda dari arus gangguan, dimana arus inrush hanya terjadi oleh beberapa kasus saja, dan yang paling banyak terjadi yaitu saat inti transformator pertama kali di beri energi. Besarnya arus inrush dapat dipengaruhi oleh beberapa hal, salah satu hal yang dapat memberikan pengaruh tersebut adalah variasi beban yang dihubungkan pada transformator sekunder. Selain pada transformator arus inrush juga dapat terjadi pada beban rumah tangga, arus ini dapat mengganggu kerja dari sirkuit breaker pada instalasi listrik rumah tangga. Besar arus inrush yang terjadi pada beban rumah tangga juga dipengaruhi oleh sifat beban itu sendiri.

Inrush current is one of the phenomena that occur on the power system especially on the transformer. This current can cause errors in the protection system so that it will disturb the reliability of power system. Inrush current is different from fault current, where inrush current occur in a few cases only, and it happen mostly when the transformer energized. Magnetizing inrush current magnitude can be affected by several things, one of the things is the variation of the load that connected to the secondary transformer. Inrush current can also occur in household electrical load, these current can disturb the circuit breaker in the electrical installation of the household. Magnitude of these inrush current is also influenced by the nature of the load itself."
Depok: Fakultas Teknik Universitas Indonesia, 2014
S54747
UI - Skripsi Membership  Universitas Indonesia Library
cover
Hariyanto
"ABSTRAK
Pada penelitian ini menjelaskan bagaimana pengenalan suara otomatis menggunakan bahasa daerah yang berasal indonesia yaitu bahasa sunda, yang dapat mengontrol alat-alat elektronik pada suatu rumah. Bahasa sunda merupakan bahasa daerah dengan penuturan terbanyak kedua di indonesia setelah bahasa jawa. Pengenalan suara menggunakan bahasa sunda dilakukan pada penelitian ini dengan tujuan dapat mengontrol beberapa alat elektronik didalam rumah secara langsung dengan akurasi yang baik. Adapun metode yang digunakan dalam pengenalan suara bahasa sunda adalah metode ekstraksi Mel Frequency Cepstral Coefficient (MFCC) dan metode classifikasi jaraingan saraf tiruan berbasis algoritma backpropagation. Ada 16 intruksi bahasa sunda yang digunakan dalam pengenalan suara sebagai input pada sistem, setiap instruksi memiliki 2 sampai 3 suku kata bahasa sunda. Output yang digunakan penulis dalam penelitian ini sebanyak 6 alat elektronik rumah tangga, untuk menghidupkan atau mematikan satu output dikontrol menggunakan 2 instruksi bahasa sunda. Data suara yang digunakan dalam proses pembelajaran algoritma backpropagation adalah sebanyak 480 data yang masing-masing instruksi bahasa sunda adalah 30 data suara yang sama, hasil dari proses pembelajaran adalah berupa bobot yang dapat digunakan untuk proses pengetesan hardware, berdasarkan hasil percobaan langsung didapat tingkat akurasi pengenalan sebesar 96.875% saat dilakukan testing terhadap sistem.

ABSTRACT
In this study explain how automatic speech recognition uses regional languages that originate from Indonesia, namely Sundanese language, which can control electronic devices in a home. Sundanese is the second most spoken local language in Indonesia after Javanese. Voice recognition using Sundanese language was carried out in this study to be able to directly control several electronic devices in the house with good accuracy. The method used in Sundanese speech recognition is the Mel Frequency Cepstral Coefficient (MFCC) extraction method and the artificial neural network classification method based on the backpropagation algorithm. There are 16 Sundanese language instructions used in speech recognition as input to the system; each instruction has 2 to 3 Sundanese language syllables. The output used by the author in this study was five household electronic devices, to turn on or turn off one output controlled using 2 Sundanese language instructions. Sound data used in the learning process of the backpropagation algorithm is 480 data, each Sundanese language instruction is 30 of the same sound data, the results of the learning process are in the form of weights that can be used for hardware testing, based on the results of direct experiments 96.875 % when testing the system."
2019
T53572
UI - Tesis Membership  Universitas Indonesia Library
cover
A. Endang Sriningsih
"ABSTRAK
Suatu sensor pengukur medan magnit apabila dibuat dalam teknologi CMOS dalam array, akan mempunyai keluaran current mode yang sesuai dengan tegangan referensi dari chip tersebut. Array yang dibentuk akan merupakan suatu unit yang sangat peka yang akan menaikkan sensitifitas dan signal to noise to ratio-nya. Sensor ini disebut Sensor Medan Magnit Array CMOS dan mempunyai karakteristik yang linier. Sensor Medan Magnit yang ada sebelumnya, yaitu Sensor Medan Magnit Magfet mempunyai karakteristik yang tidak linier. Pada penelitian ini akan diamati tentang karakteristik Magfet sebagai komponen utama untuk pengintegrasi antara Magfet dengan load resistor dan Sensor Medan Magnit Array CMOS. Sensor Medan Magnit Array CMOS merupakan pengembangan dari Sensor Medan Magnit magfet Keluaran sensor medan magnit Array CMOS ini keluarannya akan dibuat digital dengan banluan suatu integrator dan Analog Digital Converter. Hal ini dapat dilakukan karena sensor inii mempunyai karakteristik yang linier."
Fakultas Teknik Universitas Indonesia, 1996
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
Yessica Ratri Wiguna
"Transfer daya nirkabel merupakan sebuah cara baru untuk mengatasi ketidaknyamanan dari sumber listrik dengan kabel. Salah satu cara untuk menyuplai listrik tanpa kabel yaitu menggunakan resonansi kopling elektromagnetik. Cara ini dapat menyuplai listrik ke beban karena adanya medan magnet dan medan listrik di sekitar alat transfer daya nirkabel tersebut. Jadi, perlu diketahui karakteristik medan magnet dan medan listrik dari antena pengirim dan penerima yang akan digunakan pada alat tersebut dan hasilnya apabila dibandingkan dengan standar paparan elektromagnetik. Pada tulisan ini, tiga model antena loop dianalisis yaitu antena berongga, antena pejal, dan antena mikrostrip. Beberapa parameter disimulasikan dengan perangkat lunak berbasis finite integration technique (FIT) yaitu intensitas medan magnet(H-field), medan magnet(B-field), dan intensitas medan listrik(E-field).
Hasil simulasi menunjukkan bahwa antena mikrostrip menghasilkan nilai tertinggi pada ketiga parameter yang dianalisis yaitu H-field, B-field, and E-field. Hasil distribusi medan untuk tipe antena yang lain, antena berongga dan pejal, lebih kecil dari pada yang dihasilkan oleh antena mikrostrip. Berdasarkan standar paparan elektromagnetik dari ICNIRP dan IEEE, nilai medan magnet dan medan listrik alat transfer daya nirkabel hasil simulasi masih dibawah standar.Sedangkan pada penerapannya untuk teknologi ruang angkasa, desain dan pengukuran pada jarak 5 mm belum sesuai untuk teknologi ruang angkasa.

Wireless power transfer is a new way to break inconvenience of wiring power sources. The best way how to supply electric power through wireless system is using the electromagnetic coupled resonance phenomena. It can supply electric power to the load because of the magnetic and electric field that emerge around wireless power transfer device. So, we need to know the characteristic of magnetic and electric field from transmitter and receiver that will be used for the device and see the results based on electromagnetic exposure standard. In this study, three loop model of antennas are investigated, namely a solid coil model, hollow coil model, and microstrip coil model. Some parameters of those models are numerically analyzed using the finite integration technique (FIT) such as magnetic field intensity (H-field), magnetic field (B-field), and electric field intensity (E-field).
The final result shows that microstrip antenna has the highest score in H-field, B-field, and E-field. The field distribution of the others, those are solid coil and hollow coil, are relatively less than that the microstip coil has.Based on electromagnetic exposure like ICNIRP and IEEE, magnetic and electric field of wireless power transfer device are below the standards. Meanwhile, for space aircraft applications, this kind of design and simulation which are measured on 5 mm is unappropriate for space aircraft technology.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S52588
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Farhan Husain
Jakarta: UI Publishing, 2024
621.3 MUH k
Buku Teks  Universitas Indonesia Library
cover
Nji Raden Poespawati
Fakultas Teknik Universitas Indonesia, 1998
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
Eti Karuniawati
"Program yang dirancang untuk sistem 1 fasa, dapat dipergunakan untuk simulasi pengukuran nilai daya aktif, daya nyata, daya reaktif, phasor diagram, melalui Arus dan tegangan listrik AC yang dinyatakan dengan amplitudo, frekuensi, dan sudut fasa. Prosentase kesalahan hasil simulasi daya terhadap hasil perhitungan menggunakan teori daya listrik arus bolak-balik untuk setiap jenis pengukuran daya lebih kecil dari 5.10-5 %. Setiap perubahan perbedaan fasa arus dan tegangan dapat direspon secara dinamis dengan benar melalui grafik diagram phasor yang ditampilkan di panel monitor. Grafik spectrum sinyal arus untuk mengamati amplitude dan frekuensi sinyal fundamental dan sinyal harmonisa dapat merespon setiap perubahan yang terjadi dengan benar.

The program is designed for 1-phase systems, simulation can be used to measure the value of active power, apparent power, reactive power, phasor diagrams, voltage and current through the AC power represented by amplitude, frequency, and phase angle. The percentage of fault simulation results of the results calculations using the theory of alternating current electricity power every type of measurement is smaller than 5,10-5 %. Any change in the phase difference of current and voltage can be dynamically respond correctly via graphs phasor diagram shown in panel monitor. Spectrum signal flow graphs for observing the signal amplitude and frequency of the fundamental and harmonic signals can respond to any changes that occur to the right."
Depok: Fakultas Teknik Universitas Indonesia, 2013
S46805
UI - Skripsi Membership  Universitas Indonesia Library
cover
M Andre Arsyandy
"Isolasi antar kumparan pada transformator daya tersusun dari material kertas dan minyak. Dimana usia dari sebuah transformator biasanya dibatasi oleh usia dari isolasi kertasnya. Dengan pengukuran respon dielektrik pada isolasi antar kumparan di transformator daya, tingkat kandungan air pada isolasi padat serta tingkat konduktivitas pada isolasi minyaknya dapat diketahui. Pengukuran respon dielektrik pada rentang frekuensi yang luas, yakni antara 1 mHz hingga 1 KHz, mampu memberikan Gambaran mengenai karakteristik dari masing-masing material isolasi. Metode yang sedang dikembangkan untuk mendetekasi kondisi isolasi kertas-minyak pada transformator daya dikenal dengan Dielectric Frequency Response (DFR).
Skripsi ini membahas mengenai analisis kondisi isolasi antar kumparan pada transformator berdasarkan standar IEC 60422, analisis dan perbandingan hasil pengukuran DFR pada beberapa transformator yang berbeda, dan pengaruh usia transformator terhadap hasil pengukuran. Pengukuran respon dielektrik antar kumparan pada transformator daya digunakan untuk memperkirakan tingkat kandungan air pada isolasi padat seperti kertas. Pengukuran dilakukan pada lima buah transformator dengan kapasitas yang berbeda-beda, yakni 190, 145, 70, 4 MVA dua kumparan dan 412,2 MVA tiga kumparan. Secara berurutan, hasil yang didapat menunjukkan tingkat kelembaban trafo sebesar 0.2, 0.9, 1.6, 1.2, dan 1 %. Dan dari hasil pengukuran juga diketahui bahwa semakin tua usia transformator maka tingkat kelembabannya semakin tinggi.

The insulation between windings in power transformer is consist of cellulose material and oil mineral. The life of a transformer is usually limited by the life of the cellulose insulation. By measuring the frequency response from the main insulation between windings in power transformer, moisture content on the solid insulation and level conductivity on the oil mineral can be estimated. Dielectric response measurement over a wide frequency range, i.e between 1 mHz ? 1 kHz, can determine different properties of the insulation materials. Methods are being developed to detect the condition of oil-paper insulation, known as Dielectric Frequency Response (DFR).
This thesis discusses about analysis of insulation condition between windings in power transformer based on IEC 60422 standard, analysis and comparison of DFR measurement result from some different transformers, and influence from the age of transformers to measurement result. Dielectric response measurement between windings of power transformers is used to estimate the water content of the solid insulation. The measurement is applied to five transformers with different rate, i.e 190, 145, 70, and 4 MVA Power rated transformers. The result shows moisture level with 0.2, 0.9, 1.6, and 1.2 % water content. And from the result, also known that the ageing of transformer will increase moisture level in the solid insulations."
Depok: Fakultas Teknik Universitas Indonesia, 2014
S53238
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>