Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 143663 dokumen yang sesuai dengan query
cover
Muhammad Levy Aninditio
"The energy crisis in the future will be a threat for human life. Many advancement of technology currently focus on creating something that perform better than its predecessor but consuming less power. LED lighting technology has been introduced as a breakthrough of technology which possesses big advantages over the other lighting technology. LED lighting technology is able to produce a high luminous flux with very low power consumption, and also lasts longer than others. By consuming lower power, hence the amount of energy being consumed in order to generate the same amount of light will be reduced, and hence, energy saving will happen.
This undergraduate thesis discusses replacement analysis of lighting at classrooms at Engineering Center of Faculty of Engineering Universitas Indonesia. The analysis is in terms of illuminance aspect, power quality performance and cost, and it is done by replacing the existing CFL with three different options of LED lamp exist in the market with competitive price. The study suggests that using LED lamp as a replacement for CFL at classrooms at Engineering Center of Faculty of Engineering Universitas Indonesia is more efficient consuming less energy by 42.86 , and moreover saving the electricity cost as well, from IDR 864,360 annually to IDR 493,920. A comparative analysis between the three different LED lamp options is also performed. "
Depok: Fakultas Teknik Universitas Indonesia, 2016
S66112
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Arkhan Pradanugraha
"Gedung K FTUI memiliki beberapa ruang perkuliahan yang masih kurang dalam tingkat pencahayaan ruang. Studi ini bertujuan untuk mengganti sumber penerangan menggunakan lampu LED pada ruang perkuliahan sesuai standar pencahayaan yang berlaku, hemat energi, dan mengetahui biaya investasi dan operasional penerangan dalam ruang perkuliahan. Skenario penggantian pertama adalah mengganti jenis lampu tanpa merubah titik lampu yang telah terpasang. Skenario pertama ini berlaku pada ruang yang sesuai standar pencahayaan namun mengalami boros energi. Skenario penggantian kedua adalah mengganti jenis lampu dan titik lampu. Skenario kedua ini berlaku pada ruang yang belum sesuai dengan standar pencahayaan yang berlaku. Standar pencahayaan yang digunakan dalam penelitian ini adalah SNI 03-6575-2001 tingkat pencahayaan ruang kuliah sebesar 250 lux. Lampu dalam penelitian adalah lampu X dengan arus cahaya sebesar 2.500 lumen. Hasil audit penelitian ini adalah tingkat pencahayaan terendah 164 lux di ruang K205 dan tertinggi adalah 385 lux di ruang K106. Analisis arus cahaya menunjukkan jumlah lampu ideal ruang kuliah kecil adalah 16 buah dan ruang kuliah besar adalah 28 buah. Hasil analisis tingkat pencahayaan ruang menunjukkan perubahan tingkat pencahayaan tertinggi pada ruang K205 dari 164 lux menjadi 294 lux. Hasil analisis konsumsi daya menunjukkan pada kondisi eksisting adalah 11.200 watt dan pada kondisi skenario penggantian 1 dan 2 adalah 6.696 watt. Hasil analisis konsumsi energi menunjukkan pada kondisi eksisting adalah 2.240 KWh dan pada kondisi skenario penggantian adalah 1.339,2 KWh. Hasil analisis biaya skenario penggantian menunjukkan biaya investasi sebesar Rp128.629.000,00 dan persentase penghematan biaya operasional sebesar 29,21%.

Building FTUI has several lecture halls which are still lacking in the level of room lighting. This study aims to replace the lighting sources using LED light in the lecture room according to applicable lighting standards, energy saving, and know the cost of installation and operation lighting in a lecture room. This research method uses of two scenarios. The first replacement scenario is to change the type of lamp without changing the installed light points. The first scenario applies to spaces that are in accordance with lighting standards but experience energy waste. The second replacement scenario is to replace the type of lamp and the point of the lamp. This second scenario applies to spaces that are not in accordance with applicable lighting standards. The lighting standard used in this study is SNI 03-6575-2001 for the lighting level of lecture rooms by 250 lux. The audit results of this study are the lowest lighting level of 164 lux in room K205 and the highest is 385 lux in room K106. Light current analysis shows ideal number of lamps for small lecture halls are 16 and large lecture halls are 28. The results of the analysis of the room lighting level showed change in the highest lighting level in the K205 from 164 lux to 294 lux. The result of the analysis of power consumption show that the existing conditions are 11.200 watts and the replacement scenario are 6.696 watts. The result of the energy consumption analysis show that the existing condition is 2.240 KWh and the replacement scenario is 1.339,2 KWh. The result of the replacement analysis show the installation costs are Rp128.629.000,00 and the percentage of operational cost savings of 29,21%."
Depok: Fakultas Teknik Universitas Indonesia , 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Afif Fachri
"Keberadaan sumber cahaya yang sesuai adalah salah satu faktor terpenting dalam mendukung kegiatan belajar mengajar yang nyaman di ruang kelas. Penelitian ini bertujuan untuk mengaudit sistem pencahayaan eksisting pada ruang kelas gedung EC FTUI, kemudian dilakukan penggantian lampu eksisting dengan lampu LED yang dapat memenuhi kebutuhan standar pencahayaan pada ruang kelas, sesuai pada SNI 03-6575-2001 yaitu 250 lux. Berdasarkan hasil pengukuran, dapat diketahui bahwa pencahayaan alami dan buatan sudah memenuhi standar pencahayaan dengan kesesuaian 334,66%. Akan tetapi, pencahayaan dari sumber buatan saja masih belum memenuhi standar pencahayaan, di mana kesesuaian pencahayaan buatan dengan standar adalah 56,7%. Penggantian lampu akan dilakukan dengan dua skenario. Skenario pertama adalah skenario penggantian lampu tanpa mengubah titik lampu aktual, sedangkan skenario kedua adalah skenario penggantian lampu bersamaan dengan pengubahan titik lampu yang disesuaikan dengan dimensi ruangan. Hasil analisis menunjukkan rata-rata pencahayaan lampu pengganti skenario 1 sebesar 298,5 lux dan skenario 2 sebesar 309,4 lux. Penggantian lampu kedua skenario juga berdampak kepada konsumsi energi listrik per hari masing-masing sebesar 10,4192 kWh dan 10,8384 kWh. Berdasarkan analisis biaya, biaya penggantian lampu yang dibutuhkan pada skenario 1 dan skenario 2 masing-masing sebesar Rp60.953.114,08 dan Rp58.231.375,92. Selain itu, biaya operasional lampu penggantian skenario 1 dan skenario 2 masing-masing sebesar Rp2.408.416,03 dan Rp2.505.312,06 setiap tahunnya.

The existence of an appropriate light source is one of the most important factors in supporting comfortable teaching and learning activities in the classroom. This study aims to audit the existing lighting system in the classrooms of the EC FTUI building, then replace the existing lamps with LED lamps that can meet the needs of lighting standards in classrooms, according to the SNI 03-6575-2001, which is 250 lux. Based on the measurement results, it can be seen that natural and artificial lighting has met the lighting standards with 334.66% suitability. However, lighting from artificial sources alone still does not meet lighting standards, where the suitability of artificial lighting with standards is 56,7%. Lamp replacement will be carried out in two scenarios. The first scenario is a lamp replacement scenario without changing the actual lamp point, while the second scenario is a lamp replacement scenario along with changing the lamp point according to the dimensions of the room. The results of the analysis show that the average replacement lamp lighting for scenario 1 is 298.5 lux and scenario 2 is 309.4 lux. The replacement of lamps in both scenarios also has an impact on electricity consumption per day by 10.4192 kWh and 10.8384 kWh, respectively. Based on the cost analysis, the cost of replacing the lamps required in scenario 1 and scenario 2 is Rp60,953,114.08 and Rp58,231,375.92, respectively. In addition, the operational costs for replacement lamps in scenario 1 and scenario 2 are Rp2,408,416.03 and Rp2,505,312.06, respectively."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Isnainy Valencia Sari
"Pencemaran bioaerosol yang ada di dalam ruangan memiliki potensi 1.000 kali lebih berbahaya daripada di luar ruangan. Oleh karena itu, kualitas udara mikrobiologis pada ruang kuliah Gedung S di FTUI Depok perlu diteliti lebih lanjut. Sampel udara diambil menggunakan EMS bioaerosol single stage sampler selama dua menit dengan debit pemompaan 28,3 L/menit. Media pertumbuhan yang digunakan untuk bakteri dan jamur adalah TSA dan MEA. Konsentrasi bakteri tertinggi pada ruang kelas S101 2.407 362 CFU/m3 , terendah terdapat pada Lobby 1 384 142 CFU/m3. Konsentrasi jamur tertinggi ditemukan pada ruang kelas S203 810 215 CFU/m3, terendah pada S503 195 51 CFU/m3. Sebagian besar konsentrasi bakteri di udara melebihi baku mutu, sedangkan konsentrasi jamur masih memenuhi baku mutu. Suhu seluruh ruangan 21-27oC sudah memenuhi baku mutu dan kelembapan 38-71 serta Intensitas cahaya 4,21-335 lux pada sebagian ruangan tidak memenuhi baku mutu. Uji-Independent T-test menunjukan terdapat perbedaan signifikan pada konsentrasi jamur dan bakteri lantai bawah dan lantai atas sig< 0,05. Korelasi Pearson Product Moment menunjukkan terdapat korelasi yang kuat antara jumlah orang dengan konsentrasi bakteri r=0,73 dan berkorelasi lemah dengan konsentrasi jamur r=0,47. Jenis aliran udara didominasi oleh aliran laminer dan kecepatan partikel bakteri dan jamur pada kisaran 0,002-0,16 cm/detik.

Indoor bioaerosol contamination has potency 1,000 times more dangerous than outdoor. Therefore, microbiological air quality in the classrooms of Building S Engineering Faculty UI City of Depok need to be further investigated. The air samples were taken by using EMS bioaerosol single stage sampler in two minutes with airflow rate 28.3 L minute. The growth media used were TSA and MEA for bacteria and fungi. Highest bacterial concentration found in classroom S101 2,407 362CFU m3 , lowest in Lobby 1 384 142 CFU m3. The highest fungi concentration found in classroom S203 810 215 CFU m3, lowest in classroom S503 195 51 CFU m3. Most of the bacteria concentrations exceeded whereas the fungi concentration still met the quality standard. For the environmental factors, the entire classroom temperatures 21 27oC have met the quality standard but not the humidity 38 71 and light intensities 4.21 335 lux. The Independent T test showed that there were significance differences between bacteria and fungi on lower and upper floor sig."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Anggi Hazella
"Riset kolaborasi merupakan tren baru pada lingkup penelitian akademis saat ini. Para peneliti tidak lagi berperan sebagai penulis independen, melainkan setiap anggota tim menggabungkan pengetahuannya yang berbeda dan menciptakan integrasi untuk pengetahuan baru. Social Network Analysis SNA merupakan metode yang tepat untuk mengidentifikasi pola dan tren dari peneliti terkemuka serta lembaga institusinya.
Data yang digunakan dalam penelitian adalah publikasi internasional yang dihasilkan oleh Fakultas Teknik Universitas Indonesia selama enam tahun terakhir 2010 ndash; September 2016 . Tujuan dari penelitian ini adalah untuk memberikan analisis centrality melalui identifikasi struktur jaringan sosial dari peneliti dan institusi.
Hasil dari penelitian ini menunjukkan bahwa jaringan antar peneliti masih tersebar dan hanya sedikit departemen di Fakultas Teknik UI memiliki struktur jaringan yang baik. Oleh karena itu, hasil penelitian ini dapat digunakan sebagai evaluasi untuk meningkatkan kualitas riset di Fakultas Teknik, Universitas Indonesia.

Research collaboration is going concern in the hallmark of contemporary academic research. Researchers are no longer independent players, but members of team combine their different pieces of knowledge and allow integration for the creation of new knowledge. Social Network Analysis is a powerful tool to identify patterns and trends of leading researchers and institutions.
Data of international publication from Faculty of Engineering Universitas Indonesia during the last six years 2010 ndash September 2016 was used in this study to assess the social networks among researchers. The objective of this study is to provide centrality analysis that reveals the social structure of the networks by identifying researchers and their connections.
The output of this study showed that networks among researchers are still fragmented and slightly department at Faculty of Engineering UI has a good structureof authorship network. Therefore, the results of this study can be used as evaluation to improve the quality of research collaboration in Faculty of Engineering Universitas Indonesia."
Depok: Fakultas Teknik Universitas Indonesia, 2016
S66214
UI - Skripsi Membership  Universitas Indonesia Library
cover
Abdurrahman Wahid
"Skripsi ini membahas tentang perencanaan jaringan FTTH di setiap gedung di Fakultas Teknik Universitas Indonesia. Fiber to the Home (FTTH) merupakan suatu format transmisi sinyal optik dari pusat penyedia layanan ke kawasan pengguna dengan menggunakan fiber optik sebagai media penghantaran. Teknologi FTTH mampu memberikan layanan Triple Play Service dengan bandwidth dan bit rate yang tinggi.Fakultas Teknik Universitas Indonesia terdiri dari 7 departemen dan memiliki 12 gedung dengan jumlah mahasiswa,dosen, dan karyawan sebanyak 5162 orang. Kebutuhan Triple Play Service di FTUI terdiri dari 1591 port akses internet, audio, dan video. Hasil rancangan jaringan FTTH membutuhkan perangkat GPON OLT 1 buah, ODC port 96 1 buah, ODP port 12 4 buah, ODP port 24 1 buah, ONU sebanyak 53 buah.Hasil perhitungan power link budget memperlihatkan bahwa perancangan jaringan FTTH ini memenuhi standar dan mampu meningkatkan bandwidth.

This thesis discusses the design FTTH networks over the building in Engineering Faculty Universitas Indonesia. Fiber to the Home (FTTH) is a format of an optical signal transmission from the provider to the user using optical fiber as a transmission medium. FTTH provide wide bandwidth and high bit rate of Triple Play Service. Engineering Faculty has 7 departements and 12 buildings including 5162 people who study and work there. Engineering Faculty has 1591 ports Triple Play Service contain of internet access, telephone, and video. The design uses 1 GPON OLT, 1 ODN port 96, 4 ODP port 12, 1 ODP port 24, and 53 ONU. Design of FTTH network shows acceptable link power budget and wide bandwidth.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S47635
UI - Skripsi Membership  Universitas Indonesia Library
cover
Gardina Daru Adini
"Saat ini masalah pemborosan energi listrik menjadi sangat penting. Pemborosan energi secara umum sekitar 80% diakibatkan oleh faktor manusia dan 20% disebabkan oleh faktor teknis. Skripsi ini membahas tentang potensi pemborosan konsumsi energi listrik pada Fakultas Teknik Universitas Indonesia (FTUI). Fakultas Teknik merupakan fakutas yang paling banyak menggunakan konsumsi energi listrik dan penggunaan yang terbesar adalah untuk sumber tata udara (AC) dan sumber penerangan (lampu).
Berdasarkan hasil penelitian, gedung K adalah gedung kelas yang memiliki potensi pemborosan energi listrik terbesar, nilai potensi pemborosan dapat mencapai 13.637,2 kWh /bulan atau Rp 11.337.027 /bulan (4,43% dari total biaya di FTUI). Gedung S dapat mencapai nilai potensi pemborosan 7.934,48 kWh /bulan atau Rp 6.471.451 /bulan (2,53 % dari total biaya listrik FTUI). Gedung GK dapat mencapai nilai potensi pemborosan 1.716,97 kWh /bulan atau Rp 6.471.451 /bulan (0,53 % dari total biaya listrik FTUI). Gedung Pasca dapat mencapai nilai potensi pemborosan 810,46 kWh /bulan atau Rp 607.830 /bulan (0,24 % dari total biaya listrik FTUI). Pada FTUI, total kelebihan lampu adalah 255 lampu TL 2x40 W dan 38 lampu TL 2x20 W, kelebihan kapasitas AC adalah 28 PK dan kekurangan kapasitas AC adalah 53,5 PK.

Nowadays electrical energy waste problem becomes very important. Generally, around 80% of energy waste is caused by human factors and 20% of it is caused by technical factors. This research is conducted to show the potential of unnecessary energy consumption in Faculty of Engineering, University of Indonesia (FTUI). Faculty of Engineering is a faculty that consumes the most of electrical energy and the applications that consume the most of it are the air conditioning source (AC) and the illumination source (lamp).
Based on this research, K building is a class building that has greatest potential of electrical energy waste, the potential value of electrical energy waste could reach 13.637,2 kWh /month or Rp 11.337.027 /month (4.43% of the total cost usage in FTUI). S building could reach 7.934,48 kWh /month or Rp 6.471.451 /month (2,53 % of the total cost usage in FTUI). GK building could reach 1.716,97 kWh / month or Rp 6.471.451 / month (0,53 % of the total cost usage in FTUI). Pasca building could reach 810,46 kWh /month or Rp 607.830 / month (0,24 % of the total cost usage in FTUI). In the FTUI, surplusage light total is 255 TL lamps 2x40 W and 38 TL lamps 2x20 W, surplusage capacity of AC is 28 PK, and shortage capacity of AC is 53,5 PK.
"
Depok: Fakultas Teknik Universitas Indonesia, 2012
S42616
UI - Skripsi Open  Universitas Indonesia Library
cover
Satria Panji Wijayanto
"ABSTRACT
Laboratorium merupakan salah satu temapt kerja yang memiliki potensi bahaya
dan risiko K3 yang cukup besar. Dengan digunakannya berbagai peralatan dan
bahan, para pengguna laboratorium, khususnya Laboratorium Fakultas Teknik
Universitas Indonesia (FT UI), terpajan berbagai jenis bahaya seperti bahaya
kesehatan dan keselamatan. Oleh karena itu dituntut penerapan metode
pengendalian guna mereduksi potensi bahaya dan risiko K3 tersebut. Pelatihan
adalah salah satu metode control yang dapat diterapkan di laboratorium FT,
bersamaan dengan metode pengendalian lain baik engineering, administratif, atau
dengan alat pelindung diri.
Penelitian ini bertujuan untuk menganalisis kebutuhan pelatihan K3 yang
diperlukan oleh pekerja laboratorium sehingga dapat dilakukan program pelatihan
yang efektif dan efisien untuk menjawab permasalahan K3 yang ada di
laboratorium.Penelitian ini menggunakan desain kualitatif dengan metode
wawancara mendalam kepada pekerja laboratorium dan observasi di laboratorium.
Proses analisis laboratorium atau tempat kerja meliputi analisis organisasi,
pekerjaan, dan personal.
Hasil dari analisis organisasi dapat melihat dukungan dari pihak manajemen
terkait pelaksanaan K3 di laboratorium, Hasil dari analisis pekerjaan dapat melihat
bahaya dan risiko dari pekerjaan di laboratorium, serta analisis personal melihat
pengetahuan dan data pelatihan dari pekerja di laboratorium sehingga
menghasilkan matriks pelatihan K3 untuk laboratorium FT UI. Pelatihan yang
lebih dibutuhkan untuk pekerja laboratorium yaitu bersifat konseptual dan
orientasi kepada perilaku K3 di laboratorium.

ABSTRACT
Laboratory is one of the potential workplace that has large hazards and risks of
Occupational Health and Safety (OHS). With the use of a variety of equipment
and materials, particularly Laboratory, Faculty of Engineering, University of
Indonesia (UI FT), laboratory users exposed to various types of hazards such as
health and safety hazards. Therefore, the application of control methods are
required in order to reduce potential hazards and risks of OHS. Training is one of
the control methods that can be applied in the laboratory, in conjunction with
other control methods either engineering, administrative, or personal protective
equipment.
This study aims to analyze the training needs of OHS, required by the laboratory
worker training program so that it can be done effectively and efficiently to
address the problems that exist in laboratorium. This research uses a qualitative
design with in-depth interviews and observation to laboratory workers in the
laboratory. The process of laboratory analysis or analysis covering workplace
organization, work, and personal.
The results of the analysis of the organization can see the support from
management regarding the conduct of OHS in the laboratory, results of job
analysis to see the dangers and risks of work in the laboratory, as well as the
analysis of knowledge and personal look at the data in the training of laboratory
workers resulting OHS training matrix for laboratory in FT UI. More orientation
training is needed for laboratory workers and conceptual to change the behavior of
OHS in the laboratory."
2014
S56065
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ahmad Fady Ganis
"Dengan melajunya urbanisasi, semakin banyak lahan digunakan untuk aktivitas manusia. Ini mengakibatkan lebih banyaknya lahan yang berubah menjadi permukaan kedap air, dan selanjutnya mengakibatkan lebih banyaknya limpasan hujan. Penelitian ini bertujuna untuk merancang sistem pengelolaan limpasan hujan berdasarkan konsep zero delta runoff melalui implementasi infrastruktur BMP di dalam Fakultas Teknik Universitas Indonesia. Pemilihan infrastruktur BMP dan penempatannya menggunakan BMP Siting Tool. Sementara ArcGIS digunakan untuk pemetaan DTA dan tata guna lahannya. Untuk perhitungan laju limpasan menggunakan WinTR-55. Hasil menunjukan bahwa penggunaan infrastruktur BMP yaitu green roof, cistern dan porous pavement dapat mengurangi limpasan hujan rata-rata sebesar 7.8% untuk periode ulang 2, 5, 10 dan 25 tahun dengan pengurangan terbanyak terjadi pada periode ulang 2 tahun. Porous pavement juga memberikan kontribusi terbesar dalam pengurangan limpasan terlihat pada sub-DTA yang memiliki paling banyak porous pavement dapat mengurangi sebesar 9.67% dalam area tersebut. Dapat disimpulkan, infrastruktur BMP tidak dapat digunakan untuk mengurangi kondisi limpasan sampai sebelum terjadi perubahan tata guna lahan. Tetapi, pengurangan limpasan yang terjadi tetap memberikan keuntungan dan dapat dengan efektif mengurangi limpasan dalam hujan ringan yang lebih sering terjadi.

 


With urbanization accelerating, more land is developed for further human activities. This in turn would create more impermeable surfaces so that less rainfall will be infiltrated, and more runoff is created. This research aims to design a stormwater management system based on the Zero Delta Runoff Approach through implementation of BMP infrastructure in the Faculty of Engineering in Universitas Indonesia.


The types of BMP infrastructures used as well as the placement of each infrastructures is done using the BMP Siting Tool. The ArcGIS is also used to map the whole catchment area and the land use. As for the calculation of runoff conditions, the software used is WinTR-55. Results show that through the proposed implementation of BMP infrastructures recommended by the BMP Siting Tool, which are green roofs, cistern systems and porous pavements, it reduces the amount of runoff by on average 7.8 % for return periods of 2, 5, 10, and 25 years with the highest in the 2-year return period. Porous pavement also provides the highest amount of contribution shown in the sub-area that has the largest amount can reduce by up to 9.67% in that sub-area. In conclusion, the proposed design could not create runoff conditions as the same as the pre-development conditions. However, the amount of reduced runoff still creates benefits and can reduce runoff effectively especially in low intensity precipitations."
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Hisyam
"Sebuah lereng di Lawe Sikap, Kutacane, Nangroe Aceh Darussalam mengalami kegagalan lereng pada dua titik, yaitu pada STA 0+000 dan STA 0+600. Kegagalan tersebut terjadi pada tahun 2019, dimana jenis keruntuhan yang terjadi ialah keruntuhan guling (toppling). Hasil pengujian lapangan menggunakan piezometer mengatakan bahwa terdapat muka air tanah pada lereng batuan, sehingga penelitian ini berfokus dalam pemodelan muka air yang dapat menggambarkan kondisi asli di lapangan menggunakan aplikasi Midas GTS NX 2019 2D. Pemodelan Muka Air Tanah (MAT) dilakukan dengan beberapa alternatif, yaitu air hanya pada celah antar batuan, air pada celah antar batuan dan batuan utuh yang diinput nilai permeabilitas, air pada celah antar batuan memiliki ketinggian berbeda dengan air pada batuan utuh, dan pemodelan air menggunakan konsep drained-undrained. Terdapat variasi ketinggian Muka Air Tanah (MAT) untuk alternatif terpilih, sehingga akan dilakukan analisis hasil faktor keamanan, analisis tegangan, dan juga analisis pola keruntuhan.

A slope in Lawe Sikap, Kutacane, Nangroe Aceh Darussalam experienced slope failure at two points, namely at STA 0+000 and STA 0+600. The failure occurred in 2019, where the type of collapse that occurred was toppling collapse. The results of field testing using a piezometer said that there was a groundwater table on the rock slope, so this research focuses on modeling the water table that can describe the original conditions in the field using the Midas GTS NX 2019 2D application. Groundwater Level (MAT) modeling was carried out with several alternatives, namely water only in the gap between rocks, water in the gap between rocks and intact rocks with permeability values inputted, water in the gap between rocks has a different height from water in intact rocks, and water modeling using the concept of drained-undrained. There are variations in the height of the Groundwater Table (MAT) for the selected alternative, so that the results of the factor of safety analysis, stress analysis, and collapse pattern analysis will be carried out"
Depok: Fakultas Teknik Universitas Indonesia, 2023
MK-pdf
UI - Makalah dan Kertas Kerja  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>