Simangunsong, Manogu
"Transformator daya pada pembangkit listrik dilengkapi beberapa proteksi yangdapat mengamankan transformator tersebut dari kerusakan akibat gangguan baik gangguaninternal maupun gangguan eksternal, diantaranya system pentanahan netral transformator.Transformatordaya 60 MVA ini memiliki kemampuan arus hubung singkat pada sisi HV(150 kV) sebesar 2300 Amper dan tegangan fasa netral maksimum sebesar 140 kV. Darihasil perhitungan gangguan arus hubung singkat tiga fasa sebesar 5379,480 Amper dengantegangan lebih fasa netral sebesar 151,163 kV.
Hasil pengukuran nilai tahanan elektrodapentanahan sistem netral setelah terjadi kerusakan sebesar 28,1 Ohm, nilai yang diizinkansebesar <1 Ohm, hal ini diakibatkan elektroda batang system pentanahan yang mengalamicacat/ kerusakan pada bahan elektroda.Kata Kunci : Transformator, arus hubung singkat, pentanahan netral dan bahan elektroda."
Palembang: Fakultas teknik Universitas tridinanti palembang, 2014
600 JDTEK 2:1 (2014)
Artikel Jurnal  Universitas Indonesia Library
cover
Himawan Nurcahyanto
"Transformer memainkan peran besar dalam distribusi energi listrik. Salah satu faktor yang menentukan tingkat keandalan transformator adalah umur transformator. Semakin sering sebuah transformator digunakan, semakin tidak dapat diandalkan transformatornya dan karena itu memperpendek umurnya. Tujuan dari penelitian ini adalah untuk memprediksi umur transformator berdasarkan perhitungan transformator indeks kesehatan yang kemudian dimodelkan menggunakan jaringan saraf tiruan.
Hasil dari penelitian ini adalah nilai-nilai yang digunakan sebagai parameter dalam pengujian transformator yaitu isolasi minyak, furan, dan gas terlarut. Salah satu kelebihan metode jaringan saraf tiruan dalam memprediksi usia transformator adalah kesalahan perhitungan yang dapat diminimalisir.
Dari hasil penelitian ini, ditemukan bahwa hasil prediksi menggunakan jaringan saraf tiruan dan kondisi asli transformator berdasarkan indeks kesehatan transformator memiliki nilai yang hampir sama, sehingga dapat dikatakan bahwa sistem prediksi usia transformator sudah dapat digunakan langsung untuk menentukan usia transformator lain, baik yang baru maupun yang sudah beroperasi, dengan persentase kesalahan yang rendah. Selanjutnya, metode ini dapat digunakan sebagai opsi dalam mempertahankan transformator daya.

Transformers play a big role in the distribution of electrical energy. One factor that determines the level of reliability of the transformer is the life of the transformer. The more often a transformer is used, the more unreliable the transformer and therefore shortens its life. The purpose of this study is to predict the life of the transformer based on the calculation of the transformer health index which is then modeled using an artificial neural network.
The results of this study are the values ​​used as parameters in transformer testing, namely the isolation of oil, furan, and dissolved gas. One of the advantages of artificial neural network methods in predicting the age of a transformer is a calculation error that can be minimized.
From the results of this study, it was found that the prediction results using artificial neural networks and the original condition of the transformer based on the transformer health index have almost the same value, so it can be said that the transformer age prediction system can be used directly to determine the age of other transformers, both new and already operating, with a low error percentage. Furthermore, this method can be used as an option in maintaining power transformers.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Abdul Kadir
Jakarta: Pradnya Paramita , 1979
621.314 38 ABD t
Buku Teks  Universitas Indonesia Library
cover
Abdul Kadir
Jakarta: Elex Media Komputindo, 1989
621.314 38 ABD t
Buku Teks  Universitas Indonesia Library
cover
Dewanto Indra Krisnadi
"Transformator daya merupakan peralatan dengan investasi terbesar pada sebuah Gardu Induk, oleh karenanya diusahakan sebuah transformator daya dapat berfungsi sesuai dengan perkiraan masa gunanya. Penurunan masa guna dari transformator daya dipengaruhi oleh nilai akhir temperatur hot-spot dan operasi pembebanan.
Terdapat 2 jenis pembebanan darurat yaitu pembebanan darurat dalam waktu lama dan pembebanan darurat dalam waktu singkat. Kedua pembebanan tersebut dibatasi oleh nilai temperatur akhir hor-spot 140°C dan 180°C, dan dibutuhkan suatu estimasi beban agar didapatkan beban yang optimal pada saat terjadi pembebanan darurat.

Power transformers are devices with the largest investment in a substation, thus cultivated a power transformer to function in accordance with the point estimates. Decrease in the useful life of power transformers is affected by the end of the hot-spot temperature and loading operations.
There are two types of emergency loading i.e. long time emergency loading and short time emergency loading. Both are limited by the value of the final temperature of the hotspot 140°C and 180°C, and required an estimate of load in order to obtain the optimal load in the event of emergency loading.
"
Depok: Fakultas Teknik Universitas Indonesia, 2011
T29633
UI - Tesis Open  Universitas Indonesia Library
cover
cover
"[Gangguan pada transformator dapat mengakibatkan kegagalan secara tiba-tiba. Hal
ini tentu merugikan dari segi ekonomi. Untuk meminimalisasi hal ini perlu dihitung
waktu gagal transformator, sehingga dibuat program aplikasi untuk membantu
perhitungan. Perhitungan waktu gagal menggunakan distribusi Weibull dan
Lognormal, dimana kedua distribusi dibandingkan dan didapatkan distribusi yang
paling baik. Selain itu program aplikasi dapat membantu dalam menganalisa
pengaruh variasi data pada perhitungan waktu gagal, karena pada prakteknya data
gangguan yang terjadi akan berbeda-beda., Some faults in the transformer could cause a sudden failure. It is certainly harm
from economy aspect. A measurement of transformator failure time is needed to
minimise these failures, therefore an application program is designed to help those
measurements. These measurements uses Weibull distribution and Lognormal
distribution where both distributions are compared to decide which distribution
method is better. Moreover, the application program itself could help analysing the
effect of data variation on the failure period, because in the actual condition the data
that obtained will be different.]"
Fakultas Teknik Universitas Indonesia, 2014
S57952
UI - Skripsi Membership  Universitas Indonesia Library
cover
Gemelfour Ardiatus Sudrajad
"Transformator daya merupakan bagian penting dalam sistem ketenagalistrikan terutama di area tambang. Kegagalan transformator dapat menyebabkan kerugian materi, produksi, lingkungan, hingga korban nyawa. Diperlukan pengoperasian dan pemeliharaan yang tepat untuk menghindari kegagalan tersebut. Dalam melakukan pemeliharaan dan perbaikan transformator diperlukan pertimbangan aspek teknis dan non teknis. Aspek lingkungan, keselamatan kerja, manajemen proyek, hingga kode etik dan profesionalisme insinyur. Laporan keinsinyuran ini berisi tentang studi kasus kegagalan transformator di area tambang. Pada proyek ini diindikasikan bahwa transformator tersebut telah mengalami short circuit. Proyek pemeliharaan dan perbaikan ini telah memenuhi aspek profesionalisme, kode etik keinsinyuran, dan K3L. Segala pekerjaan dilakukan sesuai standar – standar keprofesian yang berlaku, mengikuti proses alur kebijakan K3 yang berlaku di nternal perusahaan, limbah pekerjaan ditangani seusai peraturan yang berlaku, dan segala pekerjaan dikomunikasikan terhadap pihak – pihak terkait.

Power transformers are an important part of the electricity system, especially in mining areas. Transformer failure can cause material, production, environmental losses and even loss of life. Proper operation and maintenance is required to avoid such failures. When carrying out maintenance and repair of transformers, technical and non-technical aspects are required to be considered. Environmental aspects, work safety, project management, to the code of ethics and professionalism of engineers. This engineering report contains case studies of transformer failures in mining areas. In this project it is indicated that the transformer has experienced a short circuit. This maintenance and repair project has fulfilled the aspects of professionalism, engineering code of ethics and K3L. All work is carried out in accordance with applicable professional standards, following the K3 policy flow process that applies internally to the company, work waste is handled in accordance with applicable regulations, and all work is communicated to related parties.
"
Depok: Fakultas Teknik Universitas Indonesia, 2024
PR-PDF
UI - Tugas Akhir  Universitas Indonesia Library
cover
Renardi Ardiya Bimantoro
"The meter which is used for measuring the energy utilises by the electric load each hour is known as the energy meter or kWh Meter. The energy is the total power consumed and utilised by the load at a particular interval of time. It is used in domestic and industrial AC circuit for measuring the power consumption. Arduino is an open-source electronics platform based on easy-to-use hardware and software. This thesis is conducted to find a way to make Arduino boards able to read inputs on a sensor, specifically in this seminar we are using Current Transformer as our sensor to measure the electricity power usage. Instrument current transformers (CTs) are widely used in various types of electrical energy measurement. Eddy current losses, losses of hysteresis, a saturation of CT, and inevitable flux leaks could lead to errors including errors in the ratio and phase angle. Improving the accuracy of CT measurement could be achieved in many ways. In this study, a bisection calibration method to overcome the error by implementing correction factor integrated with the Arduino codes is investigated. The reliability of this system has been tested in two different situations, which are a constant and variable load experiments. The result shows that the readout of the developed instrument using 100 A 50 mA CT could achieve
the deviation value of less than 2, confirming the excellence accuracy of energy meter. In order to achieve make a reliable CT based digital kWh Meter, writer conducted 3 experiment to reach error percentage below 2. The experiments are constant load experiment, non-constant load experiment, and reliability experiment. The first experiment was consist of 6 experiment with the load maintained to be constant at various level. At the beginning of the experiment we are guessing the first value of 0,2067, the number was randomly picked by writer to took the first step in continuing the bracketin method. As the result shown that the measurement value is higher than the PLN kWh meter, for that writer decided to choose the lower Design and reliability scaling factor at -0,0187 this number was picked up to see whether the correct scaling factor value region is in positive value or negative value. From the experiment 2-6 as the measurement still below the PLN measurment value, writer keep scaling up the lower scaling factor starting from -0,0187 until 0,14659 and ended up with scaling factor of 0,1766 with error percentage of 6. This result has reach writer expectation, which allow us to continue for the next experiment. The second experiment is about finding scaling factor with non-constant load. This is meant to find the right value of scaling factor when there is a change in load unexpectedly. It was consist of 6 experiments which are experiment 6 until experiment 11. During the experiment 6 until experiment 8, for the measurement value is overtaking the PLN measurement result, writer tend to reduce the scaling factor by reducing the upper scaling factor value. On the other hand, during the experiment 9 until experiment 12, for the measurement value is preceded the PLN measurement value, writer tend to increase the scaling factor by increasing the lower scaling factor value. This experiment was conducted until the error percentage below 2. The last experiment was conducted to carry out the reliability test for the device itself to handle daily use of houshold energy consumption. It using the last
value of scaling factor of experiment 11. It was conducted for almost 5 Hour. The experiment satisfied the writer expectations with error percentage of 1,923076923 which is still below 2.

Meteran yang digunakan untuk mengukur energi yang digunakan oleh beban listrik setiap jam dikenal sebagai meteran energi atau kWh Meter. Energi adalah daya total yang dikonsumsi dan digunakan oleh beban pada interval waktu tertentu. Ini digunakan dalam sirkuit AC domestik dan industri untuk mengukur konsumsi daya. Arduino adalah platform elektronik sumber terbuka yang didasarkan pada perangkat keras dan lunak yang mudah digunakan. Tesis ini dilakukan untuk menemukan cara agar papan Arduino dapat membaca input pada sensor, khususnya dalam seminar ini kami menggunakan Current Transformer sebagai sensor kami untuk mengukur penggunaan daya listrik. Instrument current transformers (CTs) banyak digunakan dalam berbagai jenis pengukuran energi listrik. Kerugian saat ini Eddy, kehilangan histeresis, saturasi CT, dan kebocoran fluks yang tak terhindarkan dapat menyebabkan kesalahan termasuk kesalahan dalam rasio dan sudut fase. Meningkatkan akurasi pengukuran CT dapat dicapai dengan banyak cara. Dalam penelitian ini, metode kalibrasi pembelahan untuk mengatasi kesalahan dengan menerapkan faktor koreksi yang terintegrasi dengan kode Arduino diselidiki. Keandalan sistem ini telah diuji dalam dua situasi yang berbeda, yaitu percobaan beban konstan dan variabel. Hasilnya menunjukkan bahwa pembacaan instrumen yang dikembangkan menggunakan 100 A/50 mA CT dapat mencapai nilai deviasi kurang dari 2, membenarkan keakuratan keunggulan meter energi. Untuk mencapai hasil kWh Meter digital berbasis CT yang andal, penulis melakukan 3 percobaan untuk mencapai persentase kesalahan di bawah 2. Eksperimen tersebut adalah eksperimen beban konstan, eksperimen beban tidak konstan, dan eksperimen reliabilitas. Eksperimen pertama terdiri dari 6 percobaan dengan beban dijaga konstan pada berbagai level. Pada awal percobaan kami menebak nilai pertama 0,2067, angka itu dipilih secara acak oleh penulis untuk mengambil langkah pertama dalam Design and reliability melanjutkan metode bracketin. Sebagai hasil menunjukkan bahwa nilai pengukuran lebih tinggi dari meter kWh PLN, untuk itu penulis memutuskan untuk memilih faktor penskalaan yang lebih rendah pada -0.0187 angka ini diambil untuk melihat apakah wilayah nilai faktor penskalaan yang benar adalah dalam nilai positif atau nilai negatif. Dari percobaan 2-6 karena pengukuran masih di bawah nilai pengukuran PLN, penulis terus meningkatkan faktor penskalaan rendah mulai dari -0.0187 hingga 0,14659 dan berakhir dengan faktor penskalaan 0,1766 dengan persentase kesalahan 6 . Hasil ini telah mencapai harapan penulis, yang memungkinkan kami untuk melanjutkan percobaan berikutnya. Eksperimen kedua adalah tentang menemukan faktor penskalaan dengan beban tidak konstan. Ini dimaksudkan untuk menemukan nilai yang tepat dari faktor penskalaan ketika ada perubahan beban secara tidak terduga. Terdiri dari 6 percobaan yaitu percobaan 6 sampai percobaan 11. Selama percobaan 6 sampai percobaan 8, untuk nilai pengukuran menyalip hasil pengukuran PLN, penulis cenderung mengurangi faktor penskalaan dengan mengurangi nilai faktor penskalaan atas. Di sisi lain, selama percobaan 9 hingga percobaan 12, untuk nilai pengukuran didahului dengan nilai pengukuran PLN, penulis cenderung meningkatkan faktor penskalaan dengan meningkatkan nilai faktor penskalaan yang lebih rendah. Eksperimen ini dilakukan hingga persentase kesalahan di bawah 2. Eksperimen terakhir dilakukan untuk melakukan uji reliabilitas untuk perangkat itu sendiri untuk menangani penggunaan konsumsi energi rumah tangga sehari-hari. Itu menggunakan nilai terakhir dari faktor skala percobaan 11. Itu dilakukan selama hampir 5 Jam. Percobaan memenuhi harapan penulis dengan persentase kesalahan 1,923076923% yang masih di bawah 2."
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Verel Sormin
"Gardu Induk Tegangan Ekstra Tinggi (GITET) X adalah salah satu gardu di Jawa Timur yang berada di wilayah operasi Perusahaan Listrik Negara (PLN) Unit Induk Transmisi Jawa Bagian Timur dan Bali (UIT JBM). Transformator Antarbus 500/150 kV di GITET X berperan untuk mendukung subsistem kelistrikan yang ada di Bali, dengan beban puncak sebesar 650 MW.
PT. PLN UIT JBM melaporkan gangguan pada IBT Unit 1 pada GITET X pada tanggal 11 September 2021 pukul 16.38 WIB, dan gangguan kedua pada tanggal 12 September 2021 pukul 22.38 WIB. Sebelum terjadinya gangguan pertama, beban yang disuplai oleh IBT-1 sebesar 111 MW (27.75% dari beban nominal). Terjadi kenaikan arus pada CT primer dan sekunder fasa S. Pengujian arus eksitasi yang dilakukan pasca gangguan kedua menunjukkan arus pada fasa S terbaca >25 A, yang melebihi batas overcurrent peralatan. Selain itu juga dilakukan pengujian Dissolved Gas Analysis (DGA). Hasil pengujian tersebut menunjukkan adanya konsentrasi gas asetilena (C2H2) sebesar 12,05 ppm, yang berarti telah terjadi arcing pada bagian internal transformator. Pengujian SFRA kembali dilakukan setelah gangguan kedua, dan didapatkan distorsi radial pada lilitan primer fasa R, S, dan T. Berdasarkan hasil pengujian tersebut diduga bahwa kerusakan pasca gangguan kedua disebabkan oleh hubung singkat antarlilitan pada lilitan fasa S, yang diakibatkan oleh faktor-faktor seperti tekanan mekanis, listrik, termal, dan juga faktor penuaan.

Gardu Induk Tegangan Ekstra Tinggi (GITET) X is an electrical substation in East Java that is located in the State Electricity Company (PLN) Transmission Main Unit for Eastern Java and Bali (UIT JBM). The interbus transformer (IBT) #1 500/150 kV at GITET X serves to support the electricity subsystem in Bali, with a peak load of 650 MW.
PT. PLN UIT JBM reported a disturbance at IBT Unit 1 GITET X on September 11, 2021 at 16.38 WIB, and a second disturbance on September 12, 2021 at 22.38 WIB. Prior to the first disturbance, the load supplied by IBT-1 was 111 MW (27.75% of the nominal load). The disturbance resulted in an increase in the current in the primary and secondary CT phase S. Excitation current testing carried out after the second fault showed the current in the S phase reading >25 A, which exceeded the equipment overcurrent limit. In addition, the Dissolved Gas Analysis (DGA) test was also carried out. The test results showed a concentration of acetylene gas (C2H2) of 12.05 ppm, which means that arcing has occurred in the internal part of the transformator. The SFRA test was again carried out after the second fault, and radial distortion was found in the primary windings of the R, S, and T phases. Based on the test results, it is inferred that the damage after the second fault was caused by a short interturn fault in the winding phase S, which was caused by factors such as mechanical, electrical, thermal stresses, as well as aging factors.
"
Depok: Fakultas Teknik Universitas Indonesia, 2022