Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 175434 dokumen yang sesuai dengan query
cover
Nada Ismah
"The incidence of loose brackets during orthodontic treatment has reached 5%; therefore, loose brackets should be rebonded. Rebonding without etching might decrease chair time without compromising bond strength. The objective of the study was to determine the shear bond strength and tensile bond strength of rebonded brackets without etching, in comparison with corresponding strength when using prior enamel etching. Forty human first upper premolar brackets were used as samples, divided into two groups. Group A (20 samples) were used to assess tensile bond strength, and group B (20) samples) to assess shear bond strength. Each group was tested twice with Universal testing Machine Shimadzu AG-5000. Test i was carried out to measure tensile and shear bond strength of brackets which were bonded after enamel etching, by pulling the brackets until loose. Test II was carried out to measure tensile and shear bond strength of brackets that were bonded without prior etching of the enamel, again by pulling the brackets until loose. The results showed a significant difference (p<0.05) between the two groups. Test II demonstrated significantly different tensile bond strength when compared to test I. Tensile and shear bond strength values of the bonding agent on rebonded bracket without etching were lower than tensile and shear bond strength values of the bonding agent in case of bonding with etching. However, even though the score decreased, it was still above the minimal score required for a bonding agent."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2007
AJ-Pdf
Artikel Jurnal  Universitas Indonesia Library
cover
Yon Achmad Santosa
"ABSTRAK
Pada perawatan ortodonsi penggunaan perekat braket langsung merupakan salah satu tujuan untuk melakukan perawatan ortodonti dengan estetika yang baik. Dewasa ini banyak tersedia macam-macam bahan dasar dari pelekat braket langsung.
Pemilihan dari bahan perekat braket langsung perlu mempertimbangkan kuat rekat geser dari bahan tersebut, agar waktu perawatan sesuai dengan rencana yang telah diperkirakan.
Penelitian ini dilakukan untuk mendapatkan perbandingan nilai rata-rata kuat rekat geser perekat braket langsung yang berbahan dasar komposit (Unite) dan glas ionomer (Fuji Ortho LC) menggunakan alat "mechanical testing machine" Shimadzu AG-5000 dengan "cross head speed" 5 mm/menit.
Hasil penelitian dianalisis dengan u j i t menunjukkan bahwa kuat rekat geser braket logam yang direkatkan dengan bahan dasar komposit (Unite) berbeda bermakna dengan kuat rekat geser braket logam yang direkatkan dengan bahan dasar glas ionomer (Fuji Ortho LC) (t=7,909 p < 0,05). "
1998
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Kaharuddin
"ABSTRAK
Penelitian ini untuk membuktikan bahwa kuat rekat geser braket daur ulang secara pengasahan lebih baik dari pada braket daur ulang secara pembakaran. Hal ini didasarkan atas perbedaan perekatan antara braket dan bahan perekat. Daur ulang secara pengasahan berikatan kimia sedangkan perekatan pada daur ulang secara pembakaran berikatan secara mekanis. Digunakan 22 sampel yang terdiri dari braket purna pakai yang harus memenuhi kriteria tertentu, dibagi dalam 2 kelompok, masing-masing secara pengasahan dan secara pembakaran. Analisis data dilakukan dengan uji-t. Hasil pengukuran setelah daur ulang memperlihatkan bahwa kuat rekat geser braket daur ulang secara pengasahan dan secara pembakaran tidak berbeda bermakna dengan t = 0,482 (P>0,05). Sedangkan nilai sebelum daur ulang memperlihatkan bahwa kelompok A dan kelompok D juga tidak berbeda bermakna dimana t = 0,927 (P> 0,05).
"
1997
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Anggi Arlan
"Latar Belakang : Braket berperan sebagai media penyalur gaya ke gigi sehingga braket perlu didesain dengan tepat. Desain braket berdasarkan konfigurasi basisnya terdiri dari mesh dan nonmesh. Basis braket tipe nonmesh dengan desain yang tepat dapat menghasilkan kekuatan rekat sesuai kriteria optimal.
Tujuan : Untuk mengetahui nilai kuat rekat geser optimal pada tiga jenis braket metal nonmesh dan menvalidasi simulasi desain jenis rumus bangun ruang dasar braket metal nonmesh.
Metode : Tiga puluh gigi premolar pertama rahang atas dibagi ke dalam tiga kelompok uji braket metal nonmesh (Tipe 1, Tipe 2, dan Tipe 3). Gigi difiksasi dalam self acrylic. Permukaan bukal gigi dibersihkan dengan pumice lalu dietsa dengan asam fosforik 37% selama 15 detik. Braket di-bonding pada permukaan tengah mahkota klinis lalu di-light cure selama 20 detik. Kuat rekat geser diuji menggunakan universal testing machine dengan blade method dan cross- head speed 0,5mm/min pada arah oklusogingival dan mesiodistal. Penilaian Adhesive Remnant Index dengan magnifikasi 10x. Analisa data menggunakan software SPSS 27.
Hasil : Kuat rekat geser dan nilai Adhesif Remnant Index pada tiga jenis braket metal nonmesh pada arah oklusongivial tidak berbeda bermakna (p>0,05). Kuat rekat geser pada arah mesiodistal pada tiga jenis braket metal nonmesh berbeda bermakna antara braket tipe 2 dan tipe 3 (p£0,05) sedangkan nilai Adhesif Remnant Index tidak berbeda bermakna (p>0,05).
Kesimpulan : Kuat rekat paling optimal adalah braket tipe 2 dengan rumus bangun ruang dasar braket “Maze Base Design” dengan konfigurasi area undercut menyerupai labirin. Konfigurasi tersebut memberikan retensi optimum pada perlekatan braket ke gigi.

Background : Bracket acts as medium for transmitting force to the teeth therefore bracket needs to be designed appropriately. Bracket design based on the base configuration consists of mesh and nonmesh. The appropriate design of nonmesh bracket produce bond strength according to optimal criteria.
Objective : Determine optimal shear bond strength and validate design simulation of the base bracket structure formula for three types of nonmesh metal bracket.
Material and Method : Thirty maxillary first premolars were divided into three test groups (Type 1, Type 2, and Type). Teeth were fixed in self acrylic. Buccal surface of tooth was cleaned with pumice and etched (37% phosphoric acid) for 15 seconds. Bracket was bonded to the middle surface of clinical crown and light cured for 20 seconds. Shear bond strength was tested using universal testing machine with blade method and cross head speed of 0.5 mm/min in occlusogingival and mesiodistal directions. Adhesive Remnant Index (ARI) assessment was 10x magnification. Data was analyzed by using SPSS 27 software.
Result : Shear bond strength and ARI for three types of nonmesh metal brackets in occlusogingival direction were not significantly different (p>0.05). Shear bond strength in mesiodistal direction was significantly different between type 2 and type 3 bracket (p£0,05), however the ARI was not significantly different (p>0.05).
Conclusion : The most optimal bond strength was type 2 bracket with “Maze Base Design” as type of bracket base structure formula. It had configuration a labyrinth-shaped undercut area providing optimum retention for bracket attachment to teeth.
"
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2023
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Diah Adisty
"Restorasi porselen untuk mahkota tiruan cekat semakin sering dijumpai pada pasien. Masalah yang mungkin terjadi saat bonding braket pada restorasi tersebut adalah braket mudah terlepas dan terjadi kerusakan pada porselen. Penggunaan bahan silane coupling agent dilaporkan dapat meningkatkan kekuatan rekat dan menjaga integritas porselen. Penelitian ini bertujuan untuk melihat perbedaan kuat rekat geser pada pemakaian tiga bahan silane coupling agentdengan komposisi organosilane yang berbeda. Penelitian ini menggunakan 21 plat porselen yang dibagi menjadi 3 kelompok, yaitu yang menggunakan bahan silane coupling agent Monobond-Plus (Ivoclar vivadent), Ultradent Silane (Ultradent product) dan Porcelain Repair Primer (Ormco). Permukaan 21 plat porselen diberi etsa asam fosfat 37%, bahan silane coupling agent dan bahan adhesif Transbond XT (3M Unitek). Setelah braket direkatkan pada permukaan plat porselen dilakukan perendaman dalam aquadest selama 24 jamdan dilakukan pengujian kuat rekat geser dengan alat uji Universal Testing Machine Shimazu AG-5000. Hasil yang diperoleh terdapat perbedaan kuat rekat geser yang signifikan secara statistik dari ketiga bahan silane coupling agent. Bahan A mempunyai kuat rekat geser tertinggi (12,827 ± 1,228 MPa) dan B mempunyai kuat rekat geser terendah (6,295 ± 0,642 MPa). Ketiga bahan tersebut memenuhi kriteria kuat rekat geser minimal yaitu 6-8 MPa. Skor ARI pada bahan B memperlihatkan permukaan porselen yang bersih, sedangkan bahan A dan C memperlihatkan adanya bahan adhesif yang merekat seluruhnya di permukaan porselen.
Kesimpulan : Bahan A dan C baik digunakan jika porselen akan diganti, sedangkan bahan B baik digunakan jika porselen tidak akan diganti.

Porcelain crown restorations are more often found in patients. Problems that may occur when bonding the bracket on the restoration is easily dislodged bracket and there is damage to the porcelain. The use of silane coupling agent has been reported to increase the bond strength and maintain the integrity of the porcelain. This study aimed to see differences of shear bond strength using three materials of silane coupling agent with different organosilane composition. This study uses 21 porcelain plates that are divided into three groups, they are using silane coupling agent material Monobond-Plus (Ivoclar Vivadent), Ultradent Silane (Ultradent product) and Porcelain Repair Primer (Ormco). The surface of 21 porcelain plates are given a 37% phosphoric acid etching, silane coupling agent material and Transbond XT adhesive (3M Unitek). Once the bracket is bonded on the surface of the porcelain plate and soaking in distilled water for 24 hours and tested the shear bond strength with test equipment Universal Testing Machine Shimazu AG-5000. The results obtained there are statistically significant differences in shear bond strength from three silane coupling agent material. Material A has the highest shear bond strength (12.827 ± 1.228 MPa) and B has the lowest shear bond strength (6.295 ± 0.642 MPa). Those three ingredients meet the minimum criteria of shear bond strength,which is 6-8 MPa. ARI scores on material B showed a clean porcelain surface, while the materials A and C show the presence of bonding adhesive on the entire surface of the porcelain.
Conclusion: Materials A and C both used if the porcelain will be replaced, while materials B is good to use if the porcelain will not be replaced.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2014
SP-Pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 2002
S41452
UI - Skripsi Membership  Universitas Indonesia Library
cover
Joy Christy Salim
"Latar belakang: Keberadaan pelikel mengurangi kualitas dan kuantitas pengetsaan enamel, yang mengurangi kuat rekat geser adhesif. Deproteinisasi enamel dengan sodium hipoklorit (NaOCl) sebelum pengetsaan diharapkan meningkatkan kuat rekat geser bahan adhesif. P

Tujuan: membandingkan nilai kuat rekat geser braket yang direkatkan dengan adhesif Unite (UN) and Xihu-BIOM (XB) pada enamel tanpa dan dengan deproteinisasi enamel menggunakan NaOCl 5.25%.

Metode: 52 gigi premolar pertama rahang atas dibagi menjadi 4 kelompok: A1) UN tanpa deproteinisasi; A2) XB tanpa deproteinisasi; B1) UN dengan deproteinisasi; dan B2) XB dengan deproteinisasi. Spesimen direkatkan braket dan diuji menggunakan Universal Testing Machine Shimazu AG-5000.

Hasil: Rerata kuat rekat geser pada kelompok A1 adalah 12.82 + 2.187 MPa, A2 adalah 14.49 + 2.986 MPa, B1 adalah 15.82 + 3.251 MPa, dan B2 adalah 12.56 + 2.726 MPa. Pada uji statististik terdapat perbedaan bermakna rerata kuat rekat geser adhesif UN antara kelompok tanpa dan dengan deproteinisasi. Selain itu terdapat perbedaan bermakna kuat rekat geser kelompok dengan deproteinisasi antara adhesif UN dan XB. Pada semua kelompok adhesif terdapat peningkatan tidak bermakna nilai ARI pada kelompok dengan deproteinisasi.

Kesimpulan: Deproteinisasi enamel dengan NaOCl 5.25% sebelum pengetsaan memberikan peningkatan bermakna kuat rekat geser adhesif Unite.


Background: Pellicle’s protein in enamel surface reduces the quality and quantity of acid etching, therefore it reduces shear bond strength. Enamel deproteinization with sodium hypochlorite (NaOCl) before etching was expected to enhance orthodontic adhesives’ shear bond strength.

Aim: to assess the effect of enamel deproteinization with 5.25% NaOCl before etching on shear bond strength of Unite (UN) and Xihu-BIOM (XB) adhesive.

Methods: Fifty-two maxillary first premolars were divided into four groups: A1) UN without deproteinization; A2) XB without deproteinization; B1) UN with deproteinization; and B2) XB with deproteinization.  Brackets were bonded and mechanical test were performed in Universal Testing Machine.

Results: The mean shear bond strength value for Group A1 was 13.51 + 2.552 MPa, A2 was 14.36 + 2.902, B1 was 16.43 + 2.615 and B2 was 13.05 + 2.348 MPa. There’s significant effect of sodium hypochlorite enamel deproteinization before acid etching on shear bond strength of Unite adhesive. Significant difference on shear bond strength of Xihu-BIOM and Unite adhesive within enamel deproteinization group was observed in this study. Within both adhesive groups, there were non-significant increase on ARI score in deproteinization group.

Conclusion: Enamel deproteinization with 5.25% NaOCl before etching increased shear bond strength of Unite significantly."

Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2017
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
cover
Sally Cahyati
"ABSTRAK
Sendi lutut buatan adalah salah satu produk dari rekayasa rancang bangun biomedikal yang merupakan suatu interface ilmu kedokteran terapan dengan ilmu teknik terapan. Sesungguhnya di negara lain teknologi ini sudah dikembangkan sejak beberapa tahun yang lalu, tetapi Indonesia baru mulai mengembangkannya. Teknologi Rapid Prototyping adalah suatu teknologi pilihan yang akan digunakan untuk memacu pertumbuhan ilmu rekayasa biomedikal di negeri ini, Penerapan teknologi Rapid Prototyping dapat menghemat waktu dan biaya produksi. Salah satu metoda Rapid Prototyping adalah metoda pemotongan dan perbedaan / penggabungan, dipilih untuk diterapkan pada pembuatan prototipe sendi lutut buatan.
Tahap pra proses pada metode ini merupakan tahapan penting karena data masukan untuk mesin Rapid Prototyping dibuat pada tahap ini. Kitalitas prototipe yang dihasilkan tergantung pada kualitas data keluaran dari tahap ini. Tahap ini dimulai dengan memproses data geometri prototipe menjadi model 3 D Solid dalam Pro Engineering. Arsip PRT yang merupakan suatu arsip keluaran dal Pro Engineering kemudian dikonversikan kedalam arsip STS Bentuk arsip STL merupakan pendekatan permukaan dari model oleh segitiga - segitiga. STL View 07 menganalisa arsip STL untuk memastikan bahwa model dapat dapat di produksi dan menyimpan irisan-irisan model kedalam arsip Common Layer Interface (CLI).Bentuk arsip Crosshatch dari model akan dibuat dengan menggunakan CLI view dan data masukan untuk mesin siap untuk digunakan.
Analisis volume dilakukan untuk mengetahui kehilangan data pada tahap pra proses yang terjadi akibat perbedaan geometri pada konversi data dari arsip PRT ke arsip STL dan dari arsip STL ke arsip CLI. Prosentase kehilangan data selama tahap pra proses sama dengan perbedaan dari kehilangan volumenya, yang berkisar antara 0,039% sampai dengan 3,16%. Volume prototipe kemudian dibandingkan dengan volume model dalam arsip PRT untuk mengetahui keabsahan dari prototipe. Prosentase kehilangan volume prototipe berkisar antara 0,047% sampai dengan 3,8% dari data pemodelan 3D solid arsip PRT' Prosentage kehilangan data ini masih dibawah batas maksimum toleransi umum yaitu + 10 %.

ABSTRACT
;Knee joint prosthesis is one of biomedical engineering's products which is an interface technology of medical and science technology. Actually, the technology has been developed years ago in the other countries, but Indonesia has just started to develop it. Rapid Prototyping Technology is an alternative technology which is being utilized to speed up biomedical engineering's growth in this country. The implementation of this technology can save in production's time and cost. One of Rapid Prototyping Technology's methods is Cutting and Glueing /Joining method , chosen for implementation is the prototyping knee joint prosthesis .
In this method the preprocessing phase is important, because data input for the Rapid Prototyping's machine is being prepared here. The quality of the prototype is depending on the quality of the data output from preprocessing phase. The phase starts with geometric data processing 3 D solid modeling of prototype in Pro Engineering . The PRT file which is an output file from Pro Engineering is converted into an STL file. The STL file format approximately the surface of the model by triangulars. The 5TL View 07 analyses an STL file that defines the model to be fabricated and "slices" the model into common layer interface (CLI) file. The crosshatches format file of the model will be made by CLI View and the input data for the machine is ready to be utilized
Volume analyses used to know data losses during the preprocessing phase, because of data conversion effect from the PRT file form to the STL form file and from the STL file form to CLI file form. The percentage of data losses during the preprocessing phase is similar to the difference of those volume looses, which ranges from 0.039% up to 3.16% . The prototype volume is to be compared with the volume of models in file format PRT to know the validity of prototypes . The percentage of volume losses of prototypes compared to the volume models in format PRT ranges from 0.047% up to 3.8 is . Those ranges are still under the maximum limit of general tolerances which is 10.
"
Depok: Fakultas Teknik Universitas Indonesia, 1998
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Eva Yuli Andari
"Latar Belakang: Prosedur bonding braket dengan teknik transiluminasi menjadi salah satu alternatif teknik penyinaran pada segmen posterior gigi yang dinilai memiliki akses dan pandangan yang terbatas. Hingga saat ini, masih terdapat perbedaan pendapat mengenai tingkat keberhasilan bonding braket dengan teknik ini. Belum ada standarisasi mengenai arah penyinaran, waktu penyinaran dan besar intensitas light-curing unit dalam bonding braket dengan teknik transiluminasi. Penelitian ini bertujuan untuk mengetahui perbedaan nilai kuat rekat geser pada polimerisasi bahan adhesif dengan teknik transiluminasi pada prosedur bonding braket logam gigi premolar terhadap berbagai intensitas light-curing unit LED.
Metode: Dua puluh empat gigi premolar dibagi secara acak kedalam 3 kelompok menggunakan light-curing unit LED dengan intensitas 1000, 1300 dan 3200 mW/cm2. Waktu penyinaran disesuaikan dengan petunjuk teknis alat. Penyinaran braket dilakukan dari arah oklusal dan lingual gigi premolar pada semua kelompok. Spesimen direndam dalam larutan akuades setelah bonding kemudian disimpan didalam inkubator dengan suhu 37°C selama 24 jam. Uji kuat rekat geser dilakukan menggunakan mesin uji universal dengan beban automatic 5kN dan crosshead speed 0.5 mm/menit.
Hasil: Nilai rerata kuat rekat geser braket logam pada kelompok LED intensitas 1000, 1300 dan 3200 mW/cm2 secara berurutan adalah 9,33±2.12 MPa, 13,34±2.66 MPa, dan 9,82±2,13 MPa. Kelompok 2 (intensitas 1300 mW/cm2) memiliki nilai kuat rekat tertinggi dibandingkan kelompok lainnya. Uji statistik menunjukan terdapat perbedaan bermakna antara nilai kuat rekat geser braket logam pada LED intensitas 1300 mW/cm2 dengan intensitas 1000 mW/cm2 dan 3200 mW/cm2. Rendahnya nilai kuat rekat geser pada kelompok 3 (intensitas 3200 mW/cm2) pada penelitian ini disebabkan oleh kurangnya pemeliharaan light-curing unit yang digunakan sehingga mempengaruhi output intensitas cahaya.
Kesimpulan: Teknik transiluminasi dengan kombinasi arah penyinaran merupakan teknik penyinaran yang efektif dan dapat diterima secara klinis pada prosedur bonding braket premolar. Ketiga intensitas yang digunakan memenuhi nilai kuat geser klinis sehingga klinisi dapat menggunakan ketiga pilihan intensitas LED tersebut. Pemeriksaan dan perawatan berkala pada light-curing unit diperlukan untuk menjaga kualitas dari perangkat yang digunakan.

Introduction: Transillumination is an alternative technique to light-curing the posterior segment of the tooth which is considered to have limited access and vision in bracket bonding procedure. However, the effectiveness of this technique is still arguable. There is still no standardization regarding the curing direction, times and light intensity of the curing unit in the bonding bracket with the transillumination technique. This study aims to determine the differences of shear bond strength of orthodontic stainless steel braket using transillumination technique with various LED curing intensity in posterior teeth.
Methods: Twenty four premolars were divided into 3 groups using a LED curing unit with various light intensity of 1000, 1300 and 3200 mW/cm2. The curing time was adjusted to the technical instructions of the curing unit. The curing direction was performed from the occlusal and lingual surface of the premolars in all groups. The specimens were placed in distilled water after bonding and then stored in an incubator at 37°C for 24 hours prior to testing. The shear bond strength test was carried out with an universal testing machine at an automatic load 5kN and crosshead speed of 0.5 mm/min.
Results: The average value of the shear bond strength of stainless steel brackets in the LED groups with intensities of 1000, 1300 and 3200 mW/cm2 respectively were 9.33±2.12 MPa, 13.34±2.66 MPa, and 9.82±2.13 MPa. The group 2 (intensity of 1300 mW/cm2) had the highest shear bond strength value compared to other groups. There was a significant difference statistically between the shear bond strength of stainless steel brackets on LED intensity of 1300 mW/cm2 with an intensity of 1000 mW/cm2 and 3200 mW/cm2. The lower shear bond strength value of the group 3 (intensity of 3200 mW/cm2) in this study occured due to the lack of maintenance of the curing unit used which affects the light intensity output.
Conslusion: The transillumination technique with a combination of curing directions from occlusal and lingual surface of posterior teeth is an effective and clinically acceptable light curing technique for orthodontic bracket bonding procedures. The three light intensities of LED curing unit used meet the clinical shear bond strength values, therefore clinicians can use all the options above. Regular inspection and maintenance of the light-curing unit is necessary to maintain the quality of the device used.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2022
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>