Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 3661 dokumen yang sesuai dengan query
cover
Kaufman, John A.
Philadelphia: PA Saunders, 2014
617.413 KAU v
Buku Teks SO  Universitas Indonesia Library
cover
Cowling, Mark G., editor
"This book provides a thorough yet succinct and accessible review of the latest knowledge in the field of endovascular surgery. All chapters have been updated to reflect the advances that have occurred during the past five years, and new chapters are included on carotid artery stenting and day case intervention. The chapter on lower limb veno-occlusive disease has been expanded to include management of deep venous thrombosis. Among the other topics considered are the endovascular treatment options in different arterial territories, aneurysm repair techniques, and the management of venous stenosis and venous insufficiency. The aim throughout is to tackle issues of evidence-based practice in order to assist trainees and experienced practitioners in making and implementing treatment decisions. "
Berlin: Springer, 2012
e20420756
eBooks  Universitas Indonesia Library
cover
Kandarpa, Krishna
Philadelphia: Wolters Kluwer, 2016
617.05 KAN h
Buku Teks SO  Universitas Indonesia Library
cover
Ignacio, Elizabeth Ann, editor
"Written as a concise, clinical guide to major interventional procedures impacting upon women’s health, Women’s health in interventional radiology focuses on a wide range of vascular and non-vascular interventions commonly performed in daily practice, including those related to the pelvis, fallopian tube, spine, and lower extremities. Chapters provide key clinical background information on each intervention, including pathophysiology, clinical manifestations, basic anatomy, and imaging features, before moving on to step-by-step explanations of the techniques. Accompanied by high-quality illustrations and images throughout, chapters also include technical hints, pearls, and pitfalls, postoperative care guidelines, outcomes data, and complications."
New York: Springer, 2012
e20420702
eBooks  Universitas Indonesia Library
cover
Langlais, Robert P.
St. Louis, Missouri: Elsevier, 2017
617.6 LAN e
Buku Teks SO  Universitas Indonesia Library
cover
Newland, J. Robert
Hudson,: Lexi-Comp, , 2012
616.31 NEW o
Buku Teks SO  Universitas Indonesia Library
cover
Nur Aida
"Telah dilakukan penelitian mengenai dosis ekuivalen pada staf intervensional yang dilakukan di Rumah Sakit Jantung dan Pembuluh Darah Harapan Kita Jakarta dengan menggunakan TLD-100 Rod dan TLD-100 Chip sebagai dosimeter personal. Hasil dari pengukuran dosis ekuivalen untuk prosedur PCI dengan menggunakan TLD-100 Rod lebih besar dosis yang diterima dibandingkan dengan menggunakan TLD-100 Chip. Perbedaan rata-rata antara hasil dari TLD-100 Rod dan TLD-100 Chip adalah 34.2%. Dari hasil pembacaan TLD-100 Rod dosis yang paling besar pada perawat adalah di titik pengukuran bagian gonad di luar apron. Untuk dokter dosis yang paling besar juga didapat di titik pengukuran bagian gonad apabila tidak memakai apron. Di lain pihak, dari hasil pembacaan TLD-100 Chip dosis yang paling besar pada perawat adalah di titik pengukuran bagian tiroid dan pada dokter dosis yang paling besar di titik pengukuran bagian tangan. Dari penelitian ini juga melakukan pengukuran dosis output yang bertujuan untuk mengetahui laju dosis pada titik IRP. Hasil dari pengukuran laju kerma udara per mA adalah 0,061 mGy/mAs sampai 0.257 mGy/mAs. Hasil laju dosis pada titik IRP dibandingkan dengan laju dosis staf dan didapat hasil persentase yang sangat kecil. Nilai DAP tidak signifikan berkorelasi dengan tingkat radiasi hamburan. Dosis ekuivalen yang didapat staf kecil sedangkan nilai DAP yang didapat besar. Rata-rata hasil pengukuran intensitas apron dengan menggunakan TLD-100 Rod dan TLD-100 Chip adalah 43.83% sampai 95.91% pada pengukuran staf perawat dan 37.38% sampai 95.91% pada pengukuran staf dokter. Sedangkan untuk tirai kaca Pb adalah 97.77 % sampai 98.95% dan untuk tirai Pb adalah 98.5% sampai 99.27%.

The equivalent dose for staffs doing interventional radiology have been done at National Cardiovascular Center Harapan Kita Hospital using TLD-100 chip and TLD-100 rod as personal detector. The results shows that the dose equivalent for PCI procedures using TLD-100 rod received larger doses than TLD-100 chip. The average dose difference between TLD-100 rod and TLD-100 chip is 34.2%. The greatest dose of TLD-100 rod was occurred at gonad point for nurses and medical doctors, whereas it was occurred at thyroid and hand point of measurement in TLD-100 chip for nurse and medical doctor respectively. In this study was performed the measurements dose rate at the point of IRP (Interventional Refferences Point). The results of measurements of air Kerma rate per mA was in the range of 0.061 mGy / mAs to 0.257 mGy / mAs and if it was comparison the IRP to dose rate staffs in very small percentage. The DAP value was not significantly in correlated with the level of radiation scattering. However, the dose equivalent obtained of staffs was very small while the DAP value is high. In addition, the average of the intensity measurement of the apron using TLD-100 rod and TLD-100 chips were in the range of 43.83% to 95.91% for nursing staff and in the range of 37.38% to 95.91% for medical staff. As for glass curtain Pb was 98.95% to 113.79% and for curtains was 98.5% Pb to 99.27%."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2013
S47213
UI - Skripsi Membership  Universitas Indonesia Library
cover
"Ce livre est le premier ouvrage francophone dédié à toutes les facettes stratégiques, diagnostiques et techniques de la prise en charge des complications des abords d’hémodialyse par les radiologues interventionnels. Il est destiné à tous les médecins, radiologues, chirurgiens, néphrologues et autres spécialistes impliqués dans le traitement endovasculaire des « fistules de dialyse ». Les débutants trouveront beaucoup de détails techniques sur les interventions les plus usuelles. Les praticiens déjà expérimentés trouveront des idées originales sur la façon d’aborder les cas les plus complexes. Les conseils sur les stratégies d’action sont largement inspirés par les résultats de la littérature et les recommandations des sociétés savantes multidisciplinaires internationales. L’ouvrage est par ailleurs abondamment illustré."
Paris: Springer, 2012
e20426693
eBooks  Universitas Indonesia Library
cover
Rofikoh
"ABSTRAK
Adapun tujuan utama dilakukannya penelitian ini yaitu mengetahui profil dosis lapangan kecil pada medium tulang belakang dengan teknik penyinaran SAD. Selain itu, kami mengevaluasi dan membandingkan dosis perencanaan pada teknik SBRT dan konvensional terhadap hasil pengukuran yang dilakukan menggunakan dosimeter Exradin A16 dan Gafchromic EBT3. Evaluasi perencanaan radioterapi dilakukan dengan menghitung indeks konformitas dan indeks homogenitas untuk daerah toraks dan lumbal. Hasilnya menunjukkan bahwa film EBT3 merupakan dosimeter dengan akurasi dan presisi yang paling tinggi dengan rata-rata standar deviasi sebesar ±1.7 dan diskrepansi maksimum sebesar 2.6%, secara berturut-turut. Deviasi FWHM untuk lapangan 0.8 x 0.8 cm2 sebesar 16.3%, sedangkan untuk lapangan 2.4 x 2.4 cm2 sebesar -3.0%. Perbandingan lebar penumbra terhadap luas lapangan kolimasi untuk lapangan 0.8 x 0.8 cm2 sebesar 37.1%, sedangkan untuk lapangan 2.4 x 2.4 cm2 sebesar 12.4%. Evaluasi indeks konformitas dan indeks homogenitas pada perencanaan menunjukkan bahwa perencanaan pada daerah toraks memiliki hasil yang lebih baik dibandingkan lumbal.

ABSTRACT
The main objective of this study was to know dose profile of small field radiotherapy in the spine case with SAD techniques. In addition, we evaluated and compared the dose planning of SBRT and conventional techniques to measurements with Exradin A16 and Gafchromic EBT3 film dosimeters. Evaluation of radiotherapy planning has been used using both conformity and homogeneity index for thorax and lumbal regions. The results showed that film EBT3 is highest precision and accuracy with average of standard deviation of ±1.7 and maximum discrepancy of 2.6%, respectively. In addition, the deviation of Full Wave Half Maximum (FWHM) in small field size of 0.8 x 0.8 cm2 is 16.3%, while it was found around 3 % for the field size of 2.4 x 2.4 cm2. The comparison between penumbra width and the collimation was around of 37.1% for the field size of 0.8 x 0.8 cm2 is 37.1%, while it was found of 12.4% for the field size of 2.4 x 2.4 cm2. Moreover, the HI and CI evaluation of the planning shows that planning of thorax indicating better results than lumbal regions"
2016
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Nadgir, Rohini
Philadelphia, PA: Elsevier, 2017
616.804 NAD n
Buku Teks SO  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>