Gde Arvindo Anandira
"Fungsi transformator dalam transmisi dan distribusi tenaga listrik semakin penting dewasa ini. Pembebanan pada transformator memengaruhi kondisi transformator dan kinerjanya. Salah satu bagian penting dalam operasi transformator adalah minyak transformator. Untuk memastikan kontinuitas operasi transformator ini, maka kondisi minyak transformator ini juga harus dijaga. Dissolved Gas Analysis (DGA) adalah teknik pengujian minyak transformator. Selama operasi transformator, kondisi minyak transformator dapat menurun ataupun rusak. Tingkat pembebanan transformator sangat memengaruhi kinerja transformator, sehingga kondisi minyak transformator juga berubah seiring perubahan tingkat pembebanan transformator. DGA dapat memberikan gambaran tentang kondisi transformator dan merepresentasikan gangguan yang terjadi pada transformator.

Transformer's role in electric power transmission and distribution is getting more important lately. Transformer loading may affect transformer's operation. Transformer oil is capable of maintaining the operation condition of transformer. In order to ensure that, transformer oil?s condition must be preserved. Transformer oil can be laboratory tested in order to get the overall condition of the transformer. The rate of transformer loading is influential in the operation of transformer that it may affect the condition of the transformer oil. Dissolved Gas Analysis (DGA) is a way to test the transformer oil. During the operation of the transformer, oil?s condition may degrade or fail. This periodic analysis? result could represent the problem occurred to the transformer."
Depok: Fakultas Teknik Universitas Indonesia, 2014
S56983
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Rifky Raihan Fauzi
"Transformator (trafo) merupakan suatu peralatan tenaga listrik yang berfungsi untuk menaikkan tenaga atau daya listrik dari pembangkit untuk kemudian disalurkan ke Gardu Induk. Minyak isolasi merupakan salah satu komponen isolasi yang sangat penting pada transformator. Selain sebagai isolasi, minyak trafo juga berfungsi melarutkan gas-gas akibat kegagalan thermal dan kegagalan elektris. Mengetahui kandungan gas terlarut dan konsentrasinya perlu dilakukan pemantauan rutin melalui pengujian Dissolved Gas Analysis (DGA). Beberapa gas yang menjadi parameter seperti Hydrogen (H2), Methane (CH4), Ethane (C2H6), Ethylene (C2H4), Acetylene(C2H2), Carbon Monoxide (CO), dan Carbon Dioxide (CO2) serta Air (H2O). Pengujian gas tersebut mengacu pada standar IEEE C57.104-2019. Hasil pengujian DGA dapat digunakan untuk mengidentifikasi indikasi jenis kegagalan pada trafo.

The transformer (transformer) is an electric power equipment that functions to increase the power or electric power from the generator to then be channeled to the substation. Insulating oil is one of the most important insulation components in a transformer. Aside from being an insulation, transformer oil also functions to dissolve gases due to thermal failure and electrical failure. Knowing the dissolved gas content and its concentration needs to be routinely monitored through the Dissolved Gas Analysis (DGA) test. Some of the gas parameters are Hydrogen (H2), Methane (CH4), Ethane (C2H6), Ethylene (C2H4), Acetylene (C2H2), Carbon Monoxide (CO), and Carbon Dioxide (CO2) and Water (H2O). The gas test refers to the IEEE C57.104-2019 standard. The results of the DGA test can be used to identify indications of the type of failure on the transformer."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rismalalo
"Skripsi ini membahas mengenai analisis pengaruh temperatur terhadap perilaku gas karena penguapan minyak isolasi transformator. Pada transformator berpendingin minyak biasanya menghasilkan gas-gas yang mudah terbakar (combustible gas) seperti hidrogen, methane, ethane, ethylane, karbon dioksida, dan karbon monoksida yang dikenal dengan istilah fault gas. Metode pengujian yang digunakan adalah Dissolved Gas Analysis (DGA) dan konsentrasi gas diukur dengan Gas Chromatograph (GC). Metode pengujian DGA akan mengidentifikasi jenis dan jumlah dari fault gas.
Dalam skripsi ini pengujiaan diutamakan pada konsentrasi gas methane karena merupakan gas yang mudah terbakar. Hasil dari uji DGA adalah data konsentrasi berbagai jenis fault gas terutama gas methane yang nantinya akan dianalisis dan diolah untuk memperoleh informasi akan adanya indikasi kegagalan-kegagalan termal dan elektris pada transformator daya.
Temperatur optimum minyak trafo yang diujikan yaitu sebesar 115°C. Pada temperatur tersebut, konsentrasi gas methane yang mudah terbakar berada dalam kondisi minimum. Tapi pada temperatur diatas 115°C konsentrasi gas methane kembali mengalami peningkatan. Hal ini dapat menyebabkan kegagalankegagalan termal dan elektris. Sehingga perlu dijaga agar temperatur minyak trafo tidak melebihi temperatur optimum dari minyak trafo tersebut yaitu sebesar 115°C.

This skripsi deals with the analysis influance temperature on the behaviour of gas due to evaporation of oil isolation transformer. The transformer oil is usually refrigerated produce gas that are flammable (compustible gas) such as hydrogen, ethane, ethylane, carbon dioxide, and carbon manoxide which is known by name fault gases. The test methode used is the Dissolved Gas Analysis (DGA) and the concentration is measured by a Gas Chromatograph (GC). The DGA testing methode will identify the type and the amount of fault gases.
In this skripsi examine take precedence on the concentration of methane gas which is flammable. The result of the test data is the DGA concentration range of fault gases primarily methane gas that will be analyzed and processed to obtain information for indication of failure from electrical and thermal power at the transformer.
The optimum temperature of the transformer oil to be tested is a 1150C. On the temperature, the concentration of methae gas which is flammable under minimum. But on the temperature above 1150C the concentration of methane has increased again. This can lead to failure of thermal and electrical. So that needs to be maintained that the temperature does not exceed the transformer oil temperature optimum of the transformer which is 115°C.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S47686
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ramadana Guna Prakasa
"Transformator merupakan mesin listrik stastis yang berperan penting dalam sistem distribusi tenaga listrik yang berfungsi mengatur besar tegangan pada masukan maupun keluaran dari sistem distribusi. Kinerja transformator dipengaruhi oleh kondisi beberapa komponen dasarnya salah satunya adalah isolator minyak yang berfungsi untuk memisahkan dua atau lebih konduktor yang berdekatan untuk mencegah adanya kebocoran arus dan juga sebagi pelindung mekanis. Selain itu minyak isolator dapat membantu dalam memprediksi kegagalan pada transformator dengan mengolah konsentrasi gas gangguan menggunakan metode Dissolved Gas Analysis, yaitu metode Total Dissolved Combustible Gas, Gas Kunci, Rasio Roger, Segitiga Duval, dan Pentagon Duval.
Data konsentrasi gas diperoleh dari transformator distribusi yang digunakan pada suatu sistem listrik dalam beberapa perushaan. Melalui pengolahan data menggunakan metode-metode DGA, diperoleh bahwa metode Penatagon Duval merupakan metode paling baik dalam memprediksi kegagalan pada transformator dibandingkan metode lainnya, karena menghasilkan hasil prediksi yang tepat dan spesifik, tidak memiliki syarat yang harus dipenuhi oleh suatu data untuk dapat diolah oleh metode tersebut, dan tidak memerlukan tahap lanjutan dalam menentukkan hasil akhir prediksi.

Transfomer is a static electrical machine that plays important role in power distribution system that serves to set input and output voltage of the system. The performance of the transformer is effected by condition of it components, one of the important components is an isolator oil that works for separate two or more conductors to prevent current leakage and also as a mechanical shielding. In addition, the isolator oil can be use for tools for predicting the failure in the transformer by processing fault gas with dissolved gas analysis method, such as Total Dissolved Combustable Gas, Key gas, Rogers Ratio, Duvals Triangel and Duvals Pentagon.
The gas concentration is obtained from distribution transformers that used in electrical system in several firms. By processing fault gas cocentration with DGA methods, it can be concluded that Duvals Pentagon Method is the most excelent method for predicting the failure in transformers since the method predicting results correctly and more specific interm of failure, it doesnt have a condition that must be fulfilled by the data before using this method, and also does not require an advance step in defining prediction result.
"
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rahmat Hardityo
"Permasalahan yang umum pada operasional transformator daya adalah timbulnya kegagalan (failure), baik kegagalan termal maupun kegagalan elektris. Kegagalan termal dan kegagalan elektris umumnya menghasilkan gas-gas berbahaya yang biasa dikenal sebagai fault gas. Kebanyakan transformator daya biasanya menggunakan minyak isolator yang fungsinya selain sebagai pendingin juga untuk melarutkan gas-gas berbahaya tersebut agar tidak beredar bebas. Mengindentifikasi jenis dan jumlah konsentrasi gas yang terlarut pada minyak dapat memberikan informasi akan adanya indikasi kegagalan yang terjadi pada transformator. Metode untuk mengidentifikasi dan menganalisis gas-gas terlarut pada minyak disebut sebagai DGA (Dissolved Gas Analysis).
Skripsi ini akan membahas bagaimana uji DGA dapat mengidentifikasi indikasi kegagalan yang terjadi pada transformator. Sejumlah sampel minyak diambil dari minyak isolator pada sebuah transformator daya lalu sampel tersebut dimasukkan ke dalam peralatan uji DGA. Hasilnya adalah sejumlah data yang menunjukkan tingkat konsentrasi fault gas. Transformator dan minyak isolator yang diujikan masih berada dalam kondisi yang baru. Setelah memperoleh sejumlah data, selanjutnya dilakukan berbagai metode analisis untuk mengetahui indikasi kegagalan yang ada pada transformator daya yang diujikan.
Berdasarkan data yang diperoleh bahwa pada awalnya transformator diindikasikan mengalami kerusakan dalam tingkat yang cukup parah. Hal ini terindikasi dari tingginya nilai gas etilen, karbon monoksida, dan karbon dioksida. Seiring pertambahan temperatur minyak, maka nilai konsentrasi fault gas juga semakin tinggi. Hal ini seharusnya tidak terjadi mengingat kondisi transformator dan minyak isolator yang masih baru. Ketika sudah dilakukan proses perbaikan transformator dan pembersihan minyak, maka nilai konsentrasi fault gas turun dengan drastis. Beberapa waktu setelah proses pembersihan minyak, kondisi ini terus berlanjut. Hal ini menunjukkan bahwa transformator berada dalam kondisi normal. Sehingga dapat diambil kesimpulan akhir bahwa ada proses yang menyalahi prosedur ketika transformator belum diaktifkan, baik dari saat perangkaian, pemvakuman ataupun proses pengisian minyak.

A problem that always occur when a power transformer is being operated is failure, both thermal fault and/or electrical fault. Thermal failure and electrical failure generally produce some gasses that known as fault gasses. Most of power transformers are usually using oil insulator that has functions as transformer cooler and as a solvent material to dissolve those fault gasses. Indentifying type and quantity of those gasses will gave us some information about indication of failure that occur in transformer unit. A method to identify and analyze fault gasses that dissolved in transformer oil is known as DGA ? Dissolved Gas Analysis.
This paper presents about how DGA testing can identify fault indicator that occur in transformer. Several oil samples are taken from oil insulator in a power transformer, and then those samples are tested by using DGA analyzer device. The result is some data that show concentration value of fault gasses. Transformer and oil insulator being tested are in fresh condition. After receive some data then some analysis methods are applied to distinguish fault indicator that occur in power transformer that have been tested.
Earlier data shows that transformer is breakdown in a severe level. This condition is indicated from the high values of some gasses, such as ethylene, carbon monoxide, and carbon dioxide. As the oil temperature increase, concentration values from fault gasses are also increase. This condition is not supposed to be happened because both transformer and oil insulator are in fresh condition. When transformer and oil insulator are already treated, so the concentration value of fault gasses will decrease significantly. Several periods after oil insulator are treated, this condition is keep continuing. So, the final conclusion is that transformer is on a normal condition. Breakdown condition from early data is occur because there are some process that out of procedure when transformer is not activated, can be either from installation, vacuuming, or oil filling process.
"
Depok: Fakultas Teknik Universitas Indonesia, 2008
S40471
UI - Skripsi Open  Universitas Indonesia Library
cover
Dewanto Indra Krisnadi
"ABSTRAK
Transformator daya merupakan peralatan dengan investasi terbesar pada sebuah Gardu Induk, oleh karenanya diusahakan sebuah transformator daya dapat berfungsi sesuai dengan perkiraan masa gunanya. Banyak faktor yang mempengaruhi lama masa guna dari transformator, salah satunya adalah memperkirakan kemungkinan terjadinya kegagalan yang diakibatkan karena penurunan sifat isolasi dari isolasi minyak dan kertas.Kegagalan transformator dapat diakibatkan adanya gas-gas yang mudah terbakar didalam kandungan minyak isolasi yang menyebabkan penurun kemampuan isolasi dari isolasi Minyak dan isolasi Kertas. Selain itu pengaruh pembebanan pada pengoperasian transformator daya juga merupakan faktor penting, karena pembebanan dapat menimbulkan panas pada minyak didalam transformator. Dari kedua hal tersebut dibuat sebuah pemodelan tingkat kekritisan transformator daya menggunakan metode logika fuzzy, untuk bisa mendeteksi dini kemungkinan terjadinya kegagalan transformator, sehingga dapat mengurangi risiko penurunan masa guna pada Transformator. Juga didapatkan tren prediksi pengaruh gas terhadap tingkat kekritisan dari gas-gas yang terlarut didalam transformator daya.
The power transformer is the largest invested equipment in a Substation, therefore a power transformer can function in accordance with the estimated useful life. Many factors influence the longevity of the transformer, one of which is to estimate the likelihood of failure resulting from a decrease in the insulating properties of oil and paper insulation.The failure of the transformer may result from the presence of Combustible gases in the insulating oil contents which lead to the lowering of insulation capacity from Oil insulation and Paper insulation. In addition, the loading effect on the operation of the power transformer is also an important factor, since loading may cause heat to the oil within the transformer. From these two things, a model of critical transformer power level using fuzzy logic method is used to detect the possibility of failure of the transformer, thereby reducing the risk of decreasing the life of the Transformer. Also, there is a prediction trend of the effect of gas on the criticality level of the dissolved gases in the power transformer. "
Depok: Fakultas Teknik Universitas Indonesia, 2018
D2588
UI - Disertasi Membership  Universitas Indonesia Library
cover
Dewanto Indra Krisnadi
"Transformator daya merupakan peralatan dengan investasi terbesar pada sebuah Gardu Induk, oleh karenanya diusahakan sebuah transformator daya dapat berfungsi sesuai dengan perkiraan masa gunanya. Penurunan masa guna dari transformator daya dipengaruhi oleh nilai akhir temperatur hot-spot dan operasi pembebanan.
Terdapat 2 jenis pembebanan darurat yaitu pembebanan darurat dalam waktu lama dan pembebanan darurat dalam waktu singkat. Kedua pembebanan tersebut dibatasi oleh nilai temperatur akhir hor-spot 140°C dan 180°C, dan dibutuhkan suatu estimasi beban agar didapatkan beban yang optimal pada saat terjadi pembebanan darurat.

Power transformers are devices with the largest investment in a substation, thus cultivated a power transformer to function in accordance with the point estimates. Decrease in the useful life of power transformers is affected by the end of the hot-spot temperature and loading operations.
There are two types of emergency loading i.e. long time emergency loading and short time emergency loading. Both are limited by the value of the final temperature of the hotspot 140°C and 180°C, and required an estimate of load in order to obtain the optimal load in the event of emergency loading.
"
Depok: Fakultas Teknik Universitas Indonesia, 2011
T29633
UI - Tesis Open  Universitas Indonesia Library
cover
Budi Lukman Efendi
"Dalam keadaan beroperasi normal, biasanya transformator akan menimbulkan gas-gas yang disebabkan oleh penuaan dan faktor pemakain transformator, seperti besarnya pembebanan dan jenis beban . Dari sudut pandang pengoperasian, hal ini penting untuk dideteksi dan diketahui penyebab dari gasgas tersebut serta mengevaluasi akibatnya terhadap operasi transformator dan untuk menentukan tindakan-tindakan yang harus dilakukan, misalnya dilakukan perawatan atau meningkatkan tingkat pengawasan. Dalam menganalisis suatu transformator, diperlukan suatu cara untuk mempermudah dalam menganalisis. Salah satu cara yang digunakan adalah melakukan pengetesan kadar gas terlarut dalam minyak transformator secara berkala sesuai dengan ketentuan pada IEEE C57.104 1991. Dari hasil analisis diperoleh nilai TDCG untuk beban 70 % adalah 1628 ppm dan untuk beban yang bersifat harmonic adalah adalah 1211 ppm. Sedangkan untuk pembebanan 55% adalah 628 ppm dan untuk jenis beban yang bersifat harmonik rendah adalah 319 ppm. Nilai Standar suatu transformator dikatakan baik apabila nilai Total Dissolved Combustible Gases (TCG) maksimum 720 ppm.

During the normal operation, a transformers usually generate gases as a result of aging and usage factor such us size and characteristic of load. From the opeRational point of view, it is important to detect and recognize the gases, and to evaluate the impact on the opeRation ot the transformer, as well as to take appropriate action, such as removing from service, or Increasing monitoring frequency. In analyzing a transformer, we need a tool to simplify the analysis. One way is often used is test ing the levels of gas dissolved in transformer oil periodically in accordance with the provisions of the IEEE C57.104 1991. The result of analysis, the value of TDCG for 70% loading factor is 1628 ppm and for harmonic loading is 1211 ppm. While the value of TDCG for 55% loading factor is 628 ppm and for non harmonic loading is 319 ppm. Where is a good transformer if the total value of Dissolved Combustible Gases (TCG), a maximum of 720 ppm."
Depok: Fakultas Teknik Universitas Indonesia, 2011
S51059
UI - Skripsi Open  Universitas Indonesia Library
cover
Muhammad Munawar
"Pada sistem pembangkitan, transmisi maupun distribusi sistem tenaga listrik, transformator merupakan salah satu aset yang paling berharga dan penting dalam penyaluran tenaga listrik. Kelangsungan operasi dari transformator sangat bergantung pada kualitas sistem isolasinya. Selama masa operasi transformator, minyak transformator akan mengalami degradasi atau pemburukan karena faktor temperatur yang tinggi serta reaksi kimia yang terjadi seperti oksidasi. Sehingga sangat penting untuk menjaga performa transformator pada sistem tenaga listrik. Skripsi ini membahas tentang kondisi performa transformator GI Gandul 2 60 MVA dimana dengan menggunakan karakteristik DGA dapat diketahui indeks performa transformator. Data diambil pada tahun 2012, 2013, dan 2014 dengan tujuan didapatkan trend performa transformator dari tahun sebelumnya sebagai evaluasi kondisi transformator. Kondisi performa transformator tahun 2012 sangat buruk dengan indeks performa 35%, tahun 2013 buruk dengan indeks perfoma 45%, dan tahun 2014 sangat buruk dengan indeks performa 0%. Dengan begitu didapatkan rata - rata indeks performa transformator 25% dengan kondisi sangat buruk dari tahun 2012 - 2014. Dengan diketahui kondisi performa transformator agar dapat menjadi evaluasi ke depannya untuk meningkatkan performa transformator sehingga kestabilan sistem tenaga listrik tetap terjaga.

In the generation, transmission, and distribution of electrical power system, transformers are the most valuable and important assets in electrical power system. The operation continuity of transformers are highly depends on the quality of insulation systems. During the service life of transformers, degradation and deterioration of the oil occurs because of high temperature and chemical reaction such as oxidation. So it is very important to maintain the performance of the transformer on the power system. This thesis discusses the performance conditions GI Gandul 2 transformer 60 MVA in which the DGA characteristics can be determined using the performance index of transformer. The data taken in 2012, 2013, and 2014 with the aim of transformer performance trends obtained from the previous year as the evaluation of the condition of the transformer. Conditions transformer performance in 2012 was poor, with 35% of the performance index, in 2013 poor performer with an index of 45%, and in 2014 was very bad with the performance index of 0%. With so obtained averages performance index of transformer 25% with a very poor condition from years 2012 to 2014. Transformer performance with known conditions that may be a future evaluations to improve the performance of the transformer so that the stability of the power system is maintained.
"
Depok: Fakultas Teknik Universitas Indonesia, 2014
S58033
UI - Skripsi Membership  Universitas Indonesia Library
cover
Mahendra Satya Putra
"Transformator adalah suatu alat listrik yang berfungsi sebagai pengubah tegangan, yakni mengubah tegangan rendah menjadi tegangan tinggi, atau sebaliknya, dengan frekuensi tetap. Dalam transformator terdapat inti besi dengan kumparan serta minyak transformator yang menjadi isolator sekaligus pendingin sistem transformator tersebut. Namun seiring beroperasinya transformator, kualitas dari minyak transformator ini akan mengalami penurunan yang mengakibatkan kualitas isolator dan juga sifat pendingin dari minyak transformator tersebut akan mengalami penurunan pula. Dalam kondisi seperti ini, kapasitansi dapat timbul di dalam transformator akibat adanya beda potensial dalam transformator di antara inti transformator dengan tangki transformator. Dalam skripsi ini akan dibahas bagaimana pengujian minyak transformator dengan metode kapasitansi dan bagaimana kaitannya dengan karakteristik minyak transformator.

The transformer is an electrical device that functions as a voltage converter, which is change the low voltage into high voltage, or vice versa, with a fixed frequency. Contained within the iron core transformer with the coil and transformer oil which becomes an insulator once the transformer cooling system. But with the operation of the transformer, the quality of the transformer oil will decline resulting in quality insulators and cooling properties of the transformer oil will decline as well. Under these conditions, the capacitance can arise in the transformer due to the potential difference between the transformer core transformer with the transformer tank. In this paper will discuss how to test transformer oil by capacitance method and how it relates to the characteristics of transformer oil.
"
Depok: Fakultas Teknik Universitas Indonesia, 2014
S55865
UI - Skripsi Membership  Universitas Indonesia Library