Abdul Aziz Rohman Hakim
"Setelah 30 tahun dioperasikan, kinerja menara pendingin RSG-GAS mengalami penurunan. Perlu dilakukan pemodelan perpindahan panas dan massa yang terjadi di dalam menara pendingin. Pemodelan perpindahan panas dan massa dilakukan pada bagian fill menara pendingin. Penelitian ini mengkaji perubahan temperatur air dan udara serta rasio kelembaban udara dari sisi masuk sampai sisi keluar fill. Kajian dilakukan dengan pendekatan Kloppers, Klimanek dan Analogi. Hasil perhitungan kemudian dibandingkan dengan data desain menara pendingin. Hasil analisis menunjukkan bahwa pendekatan Kloppers dan Klimanek 39,26 di bawah desain dan pendekatan Analogi 0,9 di atas desain. Pendekatan Analogi memberikan hasil perhitungan paling mendekati data desain.

After 30 years of operation, the performance of RSG GAS cooling towers has decreased. It is necessary the heat and mass transfer modeling that occurs inside the cooling tower. Modeling of heat and mass transfer is done on the cooling tower fill section. This study examines changes in water and air temperature and air humidity ratio from the inlet side to the outlet fill. The study was conducted using Kloppers, Klimanek and Analogical approach. The results are then compared with the cooling tower design data. The results of the analysis show that the Kloppers and Klimanek approach is 39.26 under the design and the Analogical approach is 0.9 above the design. Analogical approach gives the most closed result of the design data.
"
Depok: Fakultas Teknik Universitas Indonesia, 2018
T51016
UI - Tesis Membership  Universitas Indonesia Library
cover
I Gusti Agung Ayu Desy Wulandari
"Sistem pendingin dengan tenaga surya adalah teknologi dengan peluang yang besar dalam upaya mengurangi biaya terutama pada pemakaian listrik, dampak terhadap lingkungan, dan emisi gas rumah kaca, salah satunya adalah teknologi absorption chiller dengan bantuan energi surya untuk mendukung kerja pada komponen generator. Pada penelitian ini, simulasi termodinamika dilakukan sebagai tahapan awal desain sistem single-effect ammonia-water absorption chiller yang dimodelkan menggunakan media pendingin udara lingkungan (air-cooled) dan sumber panas berasal dari sistem kolektor termal surya, disesuaikan dengan aplikasi rumah tangga (residential) berkapasitas pendinginan rendah di negara beriklim tropis Indonesia. Kinerja sistem berupa nilai COP yang diperoleh dari simulasi sistem berdasarkan parameter input yang telah disesuaikan dengan batasan permasalahan penelitian adalah sebesar 0.554. Karakterisasi yang dilakukan terhadap dua parameter input pada sistem menunjukkan bahwa kenaikan temperatur kondensasi meningkatkan temperatur outlet generator, namun menurunkan nilai COP sistem. Hal ini bertentangan dengan pengaruh temperatur evaporasi yang menurunkan temperatur outlet generator, namun COP sistem menjadi meningkat. Sedangkan peningkatan kadar air pada solution menurunkan COP sistem. Jumlah solar collector dengan tipe ETC yang diperlukan untuk sistem single-effect ammonia-water absorption chiller adalah sebanyak lima buah kolektor dengan rangkaian seri, dan dengan kapasitas rata-rata masing-masing kolektor sebesar 1,52 kW.

Solar-powered cooling system is a technology with great opportunities to reduce operation costs, especially on electricity consumption, impact on the environment, and greenhouse gas emissions, one of which is by the use of absorption chiller technology with the help of solar energy to support the work of generator components. In this study, the thermodynamic simulation was carried out as an early stage in designing a single-effect ammonia-water absorption chiller system which is modeled using air-cooled system and the heat source comes from solar thermal collector system, adapted for residential applications with low cooling capacity in the tropical country of Indonesia. System performance in the form of COP value obtained from the system simulation based on input parameters that have been adjusted to the limits of the research problem is 0.554. System characterization was carried out on the two input parameters in the system shows that the increase in condensation temperature increases the generator outlet temperature but decreases the COP value of the system. This is contradicting to the effect of the evaporation temperature which decreases the generator outlet temperature, but the COP system increases. Meanwhile, increasing the water content of the solution decreases the COP of the system. The number of solar collectors with ETC type required for the single-effect ammonia-water absorption chiller system is five collectors in series arrangement, with an average collector capacity of 1.52 kW."
Depok: Fakultas Teknik Universitas Indonesia, 2021
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
M. Hadi Kusuma
"Untuk meningkatkan keselamatan termal pada saat terjadi kecelakaan akibat station blackout, vertical straight wickless-heat pipe pipa kalor lurus tanpa sumbu kapiler yang diletakkan secara vertikal diusulkan sebagai sistem pendingin pasif baru untuk pembuangan panas sisa hasil peluruhan di kolam penyimpanan bahan bakar bekas nuklir. Pipa kalor akan membuang panas peluruhan dari kolam penyimpanan bahan bakar bekas nuklir dan dapat menjaga sistem tetap aman. Tujuan penelitian ini adalah untuk menginvestigasi karakteristik, fenomena perpindahan kalor, dan unjuk kerja termal pipa kalor yang digunakan mencari pengaruh kecepatan pendinginan dengan besarnya kalor yang harus dibuang, menganalisis keserupaan dimensi dari pipa kalor yang digunakan, dan mengetahui teknologi pipa kalor yang dapat digunakan sebagai sistem keselamatan pasif di instalasi nuklir pada kondisi kecelakaan akibat station blackout. Investigasi secara eksperimen dilakukan dengan mempertimbangkan pengaruh tekanan awal pipa kalor, evaporator filling ratio, beban kalor evaporator, dan laju aliran pendingin di water jacket. Air pendingin disirkulasikan dalam water jacket sebagai penyerap kalor di bagian condenser. Simulasi dengan program perhitungan termohidraulika RELAP5/MOD3.2 dilakukan untuk mendukung dan membandingkan dengan hasil eksperimen yang didapatkan. Hasil eksperimen menunjukkan bahwa unjuk kerja termal terbaik pipa kalor didapatkan pada tahanan termal 0,016 C/W. Unjuk kerja termal terbaik didapatkan pada saat pipa kalor diberikan filling ratio 80 , tekanan awal terendah, laju aliran pendingin tertinggi, dan beban kalor evaporator tertinggi. Dari nilai tahanan termal tersebut didapatkan bahwa pipa kalor ini memiliki kemampuan memindahkan kalor 199 kali lebih besar jika dibandingkan dengan batang pejal tembaga dengan geometri yang sama. Model pipa kalor dalam simulasi dengan RELAP5/MOD3.2 dapat digunakan untuk mendukung investigasi secara eksperimen dalam memprediksi fenomena yang berlangung di bagian dalam pipa kalor. Analisis dimensi dan keserupaan pipa kalor yang didapatkan bisa digunakan untuk merancang pipa kalor lain dengan geometri yang berbeda namun tetap menghasilkan unjuk kerja termal yang sama. Kesimpulan investigasi yang dilakukan menunjukkan bahwa pipa kalor ini memiliki unjuk kerja termal yang tinggi dan dapat digunakan sebagai sistem pendingin pasif di kolam penyimpanan bahan bakar bekas nuklir pada saat terjadinya kecelakaan akibat station blackout.

To enhance the thermal safety when station blackout accident occurs, a vertical straight wickless heat pipe is proposed as a new passive residual heat removal system in nuclear spent fuel storage pool. The heat pipe will remove the decay heat from nuclear spent fuel pool and keep the system safe. The objective of this research is to investigate the characteristics, heat transfer phenomena, and thermal performance of heat pipe, to analyse the effect of coolant flowrate against heat to be removed, analysing the dimensional similarity of heat pipe, and to know the heat pipe technology that could be used as passive safety system in nuclear installation during to station blackout accident. The experimental investigation was conducted to investigate the heat transfer phenomena and heat pipe thermal performance with considering the influence of heat pipe initial pressure, evaporator filling ratio, evaporator heat load, and coolant volumetric flow rate of water jacket. Cooling water was circulated in water jacket as condenser cooling system. A numerical simulation with nuclear reactor thermal hydraulic code RELAP5 MOD3.2 was performed to support and to compare with the experimental results. The experimental results showed that the best thermal performance was obtained at thermal resistance of 0.016 C W, with filling ratio of 80 , the lower initial pressure, higher coolant volumetric flow rate, and higher heat load of evaporator. From thermal resistance analysis, it is found that the heat pipe has the ability to remove heat 199 times greater than copper rod with the same geometry. The RELAP5 MOD3.2 simulation model can be used to support experimental investigation and to predict the phenomena inside the heat pipe. The dimensional analysis and similitude of the heat pipe can be applied to design the other heat pipe with different geometries with produces the same thermal performance. The conclusion of investigation showed that vertical straight wickless heat pipe has higher thermal performance and can be used as passive residual heat removal system of nuclear spent fuel pool when station blackout occurs."
Depok: Universitas Indonesia, 2017
D2297
UI - Disertasi Membership  Universitas Indonesia Library
cover
"Pengendalian suatu sistem dalam suatu industri banyak sekali aplikasinya. Salah sate aplikasi pengendaban sistem yang sering dipergunakan dalam industri adalah pengendalian temperatur. Sepetti halnya pada industri pembuatan mie instant di PT. INDOFOOD SUKSES MAKMUR, aplikasi pengendaban temperatur terdapat pada HEAT EXCHANGER yang digunakan untuk memanaskan minyak goreng. Kestabilan temperatar dari minyak goreng sangat mutlak diperlukan. Heat Exchanger nwupakan salah satu aplikasi proses pemanasaa yang mempunyai prinsip kerja pelepasan papas dari suatu somber ke pemanas, yang biasanya merupa uap papas ke suatu alum pada proses industri yang memerlukan temperatur ker a yang tinggi. Di PT. Indofood Sukses Makmur, somber pangs yang digunakan adalah Uap Steam yang berasal dari Boiler, yang mempunyai temperatur sebesar 190°C dengan tekanan sekitar 8 Kg/cm2. Pada tugas akhir im akan dibahas suatu bentuk proses pemanasan pada sistem Heat Exchanger dengan berusaha untuk menganalisa karakteristik sistem dare pengemWian temperaturnya. Pada proses pengendalian perangkat lunak yang ada diusahakan untuk pengembangan lebih lanjut dalam proses pengendalian temperatur dalam cakupan yang lebih besar."
Fakultas Teknik Universitas Indonesia, 1997
S39451
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1992
S36014
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ahmad Ma`ruf
Depok: Fakultas Teknik Universitas Indonesia, 1993
S36710
UI - Skripsi Membership  Universitas Indonesia Library
cover
Winda Sarmita
"Pemeliharaan peralatan di reaktor nuklir merupakan bagian penting dari manajemen untuk menjaga keamanan operasi reaktor. Pemeliharaan Reaktor Serbaguna G.A. Siwabessy RSG-GAS saat ini mencakup kegiatan pemeliharaan rutin dan non-rutin. Dalam rangka meningkatkan efektivitas kegiatan pemeliharaan tersebut, dilakukan penelitian berkenaan dengan kegiatan pemeliharaan yang hasilnya akan diguanakan sebagai masukan kepada menjemen pengoperasi reaktor.
Penelitian ini dilakukan pada sistem proses pendingin sekunder dengan menggunakan RCM untuk menentukan tugas pemeliharaan yang efektif. Kemudian perhitungan keandalan, laju kegagalan, dan MTBF juga dilakukan untuk mengetahui nilai keandalan komponen pada sistem proses pendinginan sekunder yang dapat digunakan untuk mengukur kinerja kegiatan pemeliharaan.
Hasil dari penelitian ini mengusulkan perubahan dalam tindakan pemeliharaan saat ini setelah dilakukan analisis dengan menggunakan RCM dan nilai keandalan. Analisis RCM mengusulkan TD yang lebih rendah dari PM saat ini yaitu dari 74 menjadi 51 tindakan, dan juga tambahan 31 tindakan CD. Dari hasil analisis keandalan, komponen filter merupakan komponen yang nilai keandalannya lebih rendah dibanding komponen lain yaitu antara 41,10 - 46,81, dengan MTBF 880,85 - 1585,53 jam, lebih rendah dibanding interval waktu PM saat ini yaitu 2160 jam.

Maintenance of equipment in nuclear reactors is an important part of management to maintain the save operation of the reactor. Maintenance of G.A. Siwabessy Multipurpose Reactor RSG GAS currently includes routine and non routine maintenance activities. In order to improve the effectiveness of the maintenance activities, a research related to maintenance activities which result will be used as input to the reactor operation.
This study was conducted on a secondary cooling process system using RCM to determine the effectiveness of maintenance tasks. Then calculation of reliability, failure rate, and MTBF is also done to determine the value of component reliability in secondary cooling process system which can be used to measure performance of maintenance activity.
The results of this study suggest many changes in current maintenance task after analysis using RCM and reliability values. The RCM analysis proposes a lower TD than the current PM of 74 to 51 task, as well as an additional 31 CD task. From the results of reliability analysis, the filter component is a component whose reliability value is lower than other components that is between 41.10 46.81 , with MTBF 880.85 1585.53 hours, lower than the current PM time interval is 2160 hours.
"
Depok: Fakultas Teknik Universitas Indonesia, 2017
T48131
UI - Tesis Membership  Universitas Indonesia Library
cover
Billington, David P.
New York : Basic Books, 1983
624.2 BIL t (1)
Buku Teks  Universitas Indonesia Library
cover
Mohammad Angga Dexora
"Meningkatnya kebutuhan hidup menuntut kita untuk melakukan pekerjaan dengan lebih cepat, praktis dan dengan tenaga yang besar. Motor listrik adalah alat yang berperan penting dalam dunia industri. Penggunaan motor listrik dalam waktu yang lama akan mengakibatkan temperatur motor listrik melebihi temperatur kerja yang disarankan. Temperatur yang berlebih dapat mengakibatkan umur pakai dan efisiensi dari motor listrik menjadi berkurang. Salah satu solusi aplikatifnya adalah menggunakan heat pipe berbentuk - L sebagai pendingin pada motor listrik. Penelitian ini bertujuan untuk mengetahui performa heat pipe berbentuk - L dalam mendinginkan motor listrik. Variasi yang dilakukan dalam pengujian ini adalah daya, waktu dan jumlah heat pipe.
Dari hasil penelitian ini penggunaan 8 buah heat pipe berbentuk - L dapat membuat temperatur dinding motor pada kisaran 68,21oC. Jumlah kalor paling tinggi yang dapat dilepas heat pipe ke lingkungan yaitu 25,515 J/s dan laju perpindahan kalor pada motor paling rendah ketika beban maksimal 150 W adalah 108,504 J dengan penggunaan 8 buah heat pipe.

The increasing of people?s needs require us to work faster, do more practical and need a high power. Electric motor is the important tool in industry. However, the use of an electric motor for a long time may cause the electric motor exceed the recommended working temperature. The exceed temperature may reduce teh lifespan and the efficiency of the electric motor. One of the applicative solution is using L - shaped heat pipe as a cooler on electric motor. This research aims to determine the performance of the L - shaped heat pipe effectiveness in cooling the electric motor. The variants of this research are power, time, and the number of the heat pipes.
The result of this research by using 8 L - shaped heat pipes is these pipes can raise the motor wall temperature until around 68.21oC. The highest heat that heat pipe can release to surroundings is 25.525 J/s and the lowest heat transfer in motor when using 150 W load is 108.504 J by using 8 heat pipes.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S62536
UI - Skripsi Membership  Universitas Indonesia Library