Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 62484 dokumen yang sesuai dengan query
cover
Akhila Ramanitya
"Tujuan penelitian ini adalah melihat kekerasan permukaan dasar komposit resin aktivasi sinar yang berbeda warna. Tiga kelompok spesimen komposit resin warna terang (B1), sedang (A3), gelap (C3) dari Z250XT, 3M ESPE (USA) berbentuk silinder dipolimerisasi menggunakan LED light curing unit. Uji kekerasan dilakukan menggunakan Knoop Microhardness Tester. Hasil menunjukkan bahwa komposit resin warna terang (B1), sedang (A3) dan gelap (C3), berurutan, 82,4+1.1 KHN, 75,9+1.2 KHN dan 65.9+1.91 KHN. Terdapat perbedaan bermakna (p<0,001) antara masing-masing kelompok spesimen komposit. Disimpulkan bahwa terdapat perbedaan kekerasan permukaan dasar komposit resin antara warna yang berbeda.

The objective of the present study was to observe the undersurface microhardness of nanofilled light-cured resin composites of different shades. Three groups of specimens are used, light-shade(B1), medium-shade(A3), and dark-shade(C3) from Z250XT,3M ESPE-USA in the silinder form which later polymerized using LED light curing unit. The microhardness was tested using Knoop Microhardness Tester. The microhardness test result of light (B1), medium (A3), and dark shade (C3), 82,4+1.1 KHN, 75,9+1.2 KHN and 65.9+1.91 KHN respectively. The result showed a significant difference (p<0,001) between each group. The study proved difference undersurface microhardness between different shades of resin composite.
"
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2013
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Annisa Ulfah Hanum
"Penelitian ini bertujuan menganalisis pengaruh warna komposit resin nano aktivasi sinar terhadap temperatur di permukaan dasar. Spesimen berupa komposit resin warna terang (B1), sedang (A3), dan gelap (C3) dari Filtek Z350XT (3MESPE, USA). Uji temperatur dilakukan di permukaan dasar spesimen pada saat dilakukan penyinaran menggunakan light curing unit. Terdapat perbedaan temperatur permukaan dasar antara komposit resin warna B1 dan A3 (p<0,05), warna A3 dan C3 (p<0,05), serta warna B1 dan C3 (p<0,001). Disimpulkan, warna komposit resin mempengaruhi temperatur permukaan dasar.

The objective of the present study was to analyse the effect of light-cured nanofilled resin composite shades on their undersurface temperature. Specimens are lighter shade (B1), darker shade (C3), and middle shade (A3) of light-cured nanofilled resin composites (Filtek Z350XT, 3M-ESPE, USA). Temperature measurement was conducted on the undersurface of specimens when cured using a light curing unit. It was shown that there are temperature differences between the composites of B1 and A3 (p<0,05), A3 and C3 (p<0,05), as well as B1 and C3 (p<0,001). In conclusion, shade of light-cured nanofilled resin composites influenced their undersurface temperature.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2013
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Istiara Bakti
"Resin komposit merupakan bahan restorasi sewarna gigi yang dikenal mempunyai keunggulan estetis. Salah satu sifat estetisnya adalah efek bunglon, yakni kemampuan penyesuian warna dengan keadaan sekitarnya, yang ditandai dengan adanya pergeseran warna. Penelitian ini bertujuan untuk membuktikan adanya pergeseran warna pada resin komposit nanofiller. Jenis penelitian ini adalah studi eksperimental laboratoris. Terdapat satu kelompok kontrol resin komposit yang ditumpat di mold dan empat kelompok perlakuan yang ditumpat pada empat shade warna gigi tiruan akrilik yang telah dipreparasi. Uji warna dilakukan dengan prinsip spectrophotometer menggunakan alat vita easy shade pada 0 hari setelah penumpatan, serta 1 dan 7 hari setelah perendaman di dalam aquades. Analisis bivariat menunjukkan terdapat pergeseran warna pada resin komposit nanofiller di setiap shade.

Composite resin is a tooth-colored restorative material that is known to have an aesthetic advantage. One of its aesthetic properties is the chameleon effect which is defined as the color adjustment ability to the surrounding circumstance, which is marked by a color shifting of the composite resin. The aim of this study is to prove the existence of nanofiller composite resin color shifting. This research is a laboratory experimental study. There is one control group of composite resin which is filled in the mold and four treated group which is filled in four shades of prepared acrylic artificial teeth. The color test is carried out by a spectrophotometer principle using vita easy shade at 0 days after filling, and 1 and 7 days after immersion in distilled water. The bivariate analysis showed that there is a color shifting in nanofiller composite resin in each shade.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2013
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Marisa Amini
"ABSTRAK
Dalam penggunaannya di rongga mulut, resin komposit dapat mengalami degradasi oleh asam, terutama pada pasien dengan resiko karies tinggi. Resin komposit alkasit merupakan material dual-cured yang berbasis UDMA dan mampu melepaskan ion fluor, kalsium, dan hidroksida. Adanya ion hidroksida yang dilepaskan diketahui dapat menetralkan suasana asam. Namun, belum diketahui bagaimana pengaruh pH saliva buatan terutama pH kristis hidroksiapatit dan fluoroapatit terhadap sifat kekerasan resin komposit alkasit. Penelitian ini dilakukan untuk melihat pengaruh pH saliva buatan terhadap kekerasan resin komposit alkasit polimerisasi kimia dan cahaya. Penelitian berupa eksperimental laboratorik dengan menggunakan masing-masing 48 spesimen resin komposit alkasit (Cention-N, Ivoclar-Vivadent, Liechstenstein) polimerisasi kimia dan cahaya. Spesimen berbentuk silindris dengan diameter 6 mm dan tinggi 2 mm yang dibagi menjadi 16 kelompok perendaman. Perendaman dilakukan pada pH saliva buatan 4,5 dan 5,5 dengan lama perendaman 1, 3, 5, dan 7 hari di dalam inkubator dengan suhu 37°C. Uji kekerasan menggunakan Knoop Microhardness Tester (HMV-G Shimadzu). Hasil penelitian menunjukkan adanya penurunan kekerasan pada resin komposit alkasit polimerisasi kimia dan cahaya setelah dilakukan perendaman selama 1, 3, 5, dan 7 hari dalam saliva buatan dengan pH 4,5 dan 5,5. Nilai kekerasan tertinggi terlihat pada resin komposit alkasit polimerisasi cahaya setelah perendaman 1 hari pada pH saliva buatan 5,5 yaitu 58,41±0,23 KHN. Sedangkan nilai kekerasan terendah terlihat pada resin komposit alkasit polimerisasi kimia setelah perendaman 7 hari pada pH saliva buatan 4,5 yaitu 47,38±0,49 KHN. Berdasarkan uji statistik One-way Anova terdapat perbedaan bermakna (p<0,05) antar kelompok lama perendaman pada pH saliva buatan 4,5 dan 5,5. Hasil uji statistik Independent T-test menunjukkan terdapat perbedaan bermakna (p<0,05) antar kelompok pH saliva buatan dan antar kelompok metode polimerisasi. Dapat disimpulkan bahwa terdapat penurunan nilai kekerasan resin komposit alkasit seiring dengan semakin rendahnya pH saliva buatan dan semakin lamanya perendaman dengan penurunan terbesar pada perendaman 1 hari pertama.

ABSTRACT
In its application in the oral cavity, composite resins can be degraded by acids, especially in patients with a high caries risk. Alkasite composite resin is a dual-cured material based on UDMA and capable of releasing fluoride, calcium, and hydroxide ions. The presence of hydroxide ion which released to its environtment can neutralize the acidic condition. However, it has not yet determined how saliva pH, especially the critical saliva pH for hydroxyapatite and fluoroapatite, affects the hardness properties of alkasite composite resins. The aim of this study was to determine the effect of artificial saliva pH on the hardness of self-cured and dual-cured alkasite composite resin. This laboratory study used 48 cylindrical-shaped specimens with 6 mm in diameter and 2 mm in thickness of alkasite composite resin specimens (Cention-N, Ivoclar-Vivadent, Liechstenstein) for each polymerization methods. The specimens were divided into 16 groups for immersion in artificial saliva pH 4.5 and 5.5 and then stored in an incubator at 37°C for the next 1, 3, 5, 7 days. The hardness test was performed using a Knoop Microhardness Tester (HMV-G Shimadzu). The results showed that the hardness of self-cured and dual-cured alkasite composite resins decreased after immersion. The highest hardness value was seen in dual-cured alkasite composite resin after 1 day immersion in artificial saliva pH of 5.5 (58.41 ± 0.23 KHN). While the lowest hardness value was seen in the self-cured alkasite composite resin after 7 days immersion in artificial saliva pH 4.5 (47.38 ± 0.49 KHN). Based on the One-way Anova statistical test, there were significant differences (p <0.05) between the different immersion time groups in each artificial saliva pH. The results of the Independent T-test statistical test showed that there were significant differences (p <0.05) between the artificial saliva pH groups and between polymerization methods groups. It was concluded that there was a decrease in the hardness of alkasite composite resin along with the lower pH of artificial saliva and the increasing immersion time. The greatest decrease occured in the first day of immersion."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Bima Surya Heri Itanto
"Latar Belakang: Perawatan restorasi resin komposit nanofilled dan nanohybrid memerlukan prosedur pemolesan untuk mengurangi tingkat kekasaran permukaan sehingga permukaan halus dan mengkilap.
Tujuan: Membandingkan kekasaran permukaan resin komposit nanofilled dan nanohybrid setelah pemolesan menggunakan teknik multiple-step.
Metode: 40 spesimen resin komposit yang dibagi ke dalam 2 kelompok 20 spesimen nanofilled Filtek Z350XT A dan 20 spesimen nanohybrid Filtek Z250XT B dipersiapkan kemudian dipoles. Setelah direndam dalam saliva buatan selama 24 jam, tingkat kekasaran permukaan diukur dengan surface roughness tester.
Hasil: Hasil rerata tingkat kekasaran permukaan beserta standar deviasi kelompok A adalah 0,0967 m 0,0174 sedangkan kelompok B adalah 0,1217 m 0,0244. Secara statistik p=0,05 terdapat perbedaan signifikan antara kedua kelompok.
Kesimpulan: Dapat disimpulkan bahwa tingkat kekasaran permukaan resin komposit nanofilled setelah pemolesan dengan teknik multiple-step lebih baik dibandingkan dengan nanohybrid.

Background: Restorative treatment using nanofilled and nanohybrid composite should be finished and polished to reduce surface roughness and create smoother surface of the composite.
Objective: To compare the surface roughness nanofilled and nanohybrid composite resin after polishing using multi step technique.
Method: 40 composite resin specimens were divided into 2 groups 20 nanofilled specimens Filtek Z350XT A and 20 nanohybrid specimens Filtek Z250XT B was prepared and then polished. After immersion in artificial saliva for 24 hours, the surface roughness is measured with a surface roughness tester.
ResultL The mean surface roughness results along with standard deviation of group A is 0,0967 m 0,0174 while group B is 0,1217 m 0,0244. Statistically with p 0.05 , there are significant differences between each group.
Conclusion: Surface roughness of nanofilled composite resin after polishing with multiple step technique is better than nanohybrid.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2016
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fahrizal Fadhlurahman Fauzan
"Latar Belakang: Pengunyahan merupakan proses makanan dihancurkan dan dicampur dengan air liur untuk membentuk bolus untuk ditelan. Proses pengunyahan memberikan tekanan pada gigi yang mempengaruhi degradasi sifat mekanik pada gigi. Salah satu cara untuk mengembalikan email yang terdegradasi adalah dilakukan restorasi dengan bahan seperti resin komposit. Bahan restorasi diharapkan memiliki sifat mekanik yang sebanding dengan email. Tujuan: Menganalisis perbedaan kekerasan mikro permukaan resin komposit mikro hibrida dengan resin komposit nano hibrida. Metode: 8 spesimen resin komposit mikro hibrida (Kerr Herculite™ Précis Composite) dan 8 spesimen resin komposit nano hibrida (Kerr Harmonize™ Nano hibrida Universal Composite) disiapkan untuk uji kekerasan mikro permukaan lalu dianalisis dengan uji Independent T-Test. Hasil Penelitian: Terdapat perbedaan bermakna dengan signifikansi p<0,041 (p<0,05) antara nilai kekerasan mikro permukaan resin komposit mikro hibrida dan resin komposit nano hibrida dengan nilai kekerasan resin komposit nano hibrida lebih tinggi (45,51 KHN) dibandingkan dengan resin komposit mikro hibrida (42,31 KHN). Kesimpulan: Resin komposit nano hibrida memiliki kekerasan mikro permukaan lebih tinggi dibandingkan dengan resin komposit mikro hibrida.

Background: Chewing is the process of crushing food and mixing with saliva to form a bolus for swallowing. The chewing process puts pressure on the teeth which affects the degradation of the mechanical properties of the teeth. One of the ways to restore degraded enamel is to do restoration with materials such as composite resin. The restoration material is expected to have mechanical properties comparable to that of enamel. Objective: Analyzing the differences in surface microhardness of microhybrid composite resin with nanohybrid composite resin. Methods: 8 specimens of microhybrid composite resin (Kerr Herculite ™ Précis Composite) and 8 specimens of nanohybrid composite resin (Kerr Harmonize ™ Nanohybrid Universal Composite) were prepared for surface microhardness testing and then analyzed by Independent T-Test. Result: There was a significant difference with a significance of p <0.041 (p <0.05) between the surface micro-hardness value of hybrid micro-composite resin and nano-hybrid composite resin with higher surface microhardness value for nanohybrid composite resin (45.51 KHN) compared to microhybrid composite resin. (42.31 KHN). Conclusion: The nanohybrid composite resin has higher surface microhardness compared to the microhybrid composite resin."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Jung, Jumin
"Latar belakang: Light Curing Unit (LCU) LED metode pulsa iradiansi 900 mW/cm2 telah dikembangkan untuk menghasilkan suhu pada ruang pulpa lebih rendah dibandingkan metode kontinu akibat polimerisasi resin komposit Nanofill pada durasi penyinaran 20 detik. Tujuan: menganalisis pengaruh durasi dan metode penyinaran pulsa terhadap kekerasan permukaan dan Depth of Cure resin komposit Nanofill. Metode: Spesimen resin komposit Nanofill (diameter 6 mm dan tebal 2 mm) disinar dengan LCU LED metode pulsa beriradiansi 900 mW/cm2 selama 5, 10, dan 20 detik, lalu direndam di dalam 5 ml akuades (37˚C 24 jam). Setiap spesimen diuji dengan Knoop Microhardness Tester sebanyak 5 kali pada permukaan atas dan bawah dan dihitung depth of cure. Hasil: Terjadi peningkatan kekerasan permukaan yang disinar dengan LCU metode penyinaran pulsa dan kontinu selama 5 hingga 20 detik yaitu 45,9±1,6/26,4±1,6 KHN hingga 68,8±1,8/57,4±1,6 KHN, dan 46,8±1,6/28,2±1,5 KHN hingga 69,3±1,2/57,8±1,1 KHN. Terdapat perbedaan bermakna (p<0,05) pada kekerasan permukaan di kelompok durasi penyinaran dengan uji One-way Anova dan post hoc Tamhane. Pada nilai depth of cure resin komposit Nanofill yang disinar antara kedua metode penyinaran tidak terdapat perbedaan bermakna (p>0,05) secara statistik. Kesimpulan: Resin komposit Nanofill yang disinar pada durasi lebih lama menunjukkan kekerasaan permukaan atas maupun bawah lebih tinggi dibandingkan dengan durasi lebih pendek. Demikian pula, depth of cure pada durasi lebih lama menunjukkan nilai lebih tinggi. Penyinaran metode pulsa iradiansi 900 mW/cm2 dan kontinu iradiansi 900 mW/cm2 menunjukkan kekerasan permukaan dan depth of cure yang sama."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Lathifa Khaerani
"Latar Belakang: Resin komposit bulk-fill dapat merestorasi kavitas dengan kedalaman 4-5 mm dalam sekali penyinaran sehingga dapat mempersingkat prosedur restorasi, Polimerisasi resin komposit dapat dipengaruhi oleh suhu, termasuk suhu penyimpanan dan preheating resin komposit. Polimerisasi yang adekuat diperlukan untuk mendapatkan kekerasan permukaan yang optimal. Tujuan: Mengetahui pengaruh suhu penyimpanan dan preheating terhadap kekerasan permukaan resin komposit bulk-fill. Metode: Tiga puluh spesimen Tetric® N-Ceram Bulk-Fill shade IVA (diameter 6 mm dan tebal 3 mm) dibuat dari 3 kelompok perlakuan yaitu resin komposit yang disimpan pada suhu ruangan 23±1°C selama 24 jam (kontrol), lemari pendingin 4±1°C selama 24 jam, dan preheating 39°C selama 10 menit. Spesimen dipolimerisasi menggunakan light curing unit LED berintensitas 1100 mW/cm2 selama 10 detik dan disimpan di inkubator pada suhu 37°C selama 24 jam. Uji kekerasan menggunakan Knoop Microhardness Tester. Analisis data dengan uji statistik One-Way ANOVA dan Post Hoc Bonferroni. Hasil: Kekerasan permukaan antara kelompok perlakuan suhu penyimpanan dan preheating menunjukkan terdapat perbedaan bermakna secara statistik (p<0,05). Kesimpulan: Kekerasan permukaan resin komposit bulk-fill pada suhu penyimpanan di lemari pendingin 4±1˚C lebih rendah dibandingkan di ruangan 23±1˚C, sedangkan kekerasan permukaan resin komposit bulk-fill dengan suhu preheating 39˚C lebih tinggi dibandingkan penyimpanan di ruangan 23±1˚C.

Background: Bulk-fill composite resin could be used in 4-5 mm thickness for each photo-polymerization so that it can shorten the restoration procedure time. Polymerization of composite resin can be affected by temperature, including composite resin’s storage temperature and preheating. Adequate polymerization needed to achieve optimal surface hardness or composite resin. Objective: To evaluate the influence of storage temperature and preheating on surface hardness of Bulk-fill Composite Resin. Methods: Thirty specimens of Tetric® N-Ceram Bulk-Fill shade IVA (6 mm of diameter and 3 mm of thickness) were made from 3 groups according to storage temperature and preheating of the composite: (1) room temperature 23±1°C for 24 hours (control), (2) refrigerator temperature 4±1°C for 24 hours, and (3) preheating 39°C for 10 minutes. Each specimen was polymerized using LED Curing Unit for 10 minutes with 1100 mW/cm2 intensity, then immersed in 5 ml of aquadest and kept in 37°C incubator for 24 hours. urface hardness was measured using Knoop Microhardness Tester at the top surfaces. Data were statistically analyzed using One-Way ANOVA and Post Hoc Bonferroni test. Result: There was a statistically significant difference (p0,05) of surface hardness value between all test groups. Conclusion: Surface hardness of bulk-fill composite resin at refrigerator temperature 4±1˚C are lower than room temperature 23±1˚C, while surface hardness of bulk-fill composite resin with preheating 39°C are higher than room temperature 23±1˚C."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Aurelia Yasniyati Ndalon
"Resin komposit bulk-fill adalah jenis resin komposit yang dapat menghemat waktu pengerjaan dan mengurangi kemungkinan jebakan udara karena mempunyai kemampuan untuk berpolimerasi secara memadai dengan depth of cure 4-5 mm. Ketahanan resin komposit terhadap keausan dipengaruhi oleh beberapa faktor salah satunya adalah kekerasan permukaan. pH asam adalah salah satu faktor yang bisa menyebabkan terjadinya penurunan tingkat kekerasan resin komposit. Obat kumur herbal adalah salah satu produk dengan variasi pH yang banyak digunakan untuk mengatasi masalah pada rongga mulut. Tujuan: Penelitian ini bertujuan untuk mengetahui pengaruh pH beberapa jenis obat kumur herbal terhadap kekerasan permukaan resin komposit bulk-fill Metode: Tiga puluh dua (32) spesimen resin komposti bulk-fill (Tetric® N-Ceram bulk-fill shade IVA dengan diameter 6 mm dan tinggi 3 mm) dibagi menjadi 4 kelompok dengan masing-masing kelompok terdiri dari 8 spesimen. Masing-masing spesimen akan dilakukan perendaman pada suhu 370 C selama 6 jam dalam 20 ml larutan yang terdiri dari akuades (pH 6,78), pepsodent herbal natural (pH 6,54), total care lemon herbs (pH 5,04), listerine gum care jahe herbal (pH 4,07). Sebelum dan sesudah perendaman masing-masing spesimen akan diukur nilai kekerasan permukaan dengan Knoop Hardness Tester (HMV-G®: G21 Series Micro Vickers Hardness Tester Shimadzu) Hasil: Terjadi penurunan kekerasan permukaan resin komposit Tetric® N-Ceram Bulk-fill setelah direndam dalam semua larutan. Nilai rata-rata kekerasan permukaan sebelum perendaman untuk semua spesimen adalah 37,89±0,50 KHN. Sedangkan nilai rata-rata kekerasan permukaan sesudah perendaman pada masing-masing kelompok adalah akuades (pH 6,78) sebagai kelompok kontrol 36,36±1,01 KHN, obat kumur pepsodent 34,31±0,65 KHN, total care lemon herbs (pH 5,04) 32,41±0,61 KHN, obat kumur listerine gum care jahe herbal 30,68±0,43 KHN. Berdasarkan hasil uji One-Way ANOVA dan uji Post Hoc Post Hoc Tamhane menunjukkan bahwa terdapat perbedaan bermakna (p < 0,05) antar semua kelompok perendaman. Kesimpulan: Terdapat penurunan nilai kekerasan permukaan resin komposit bulk-fill setelah dilakukan peredaman dalam larutan akuades, pepsodent herbal natural, total care lemon herbs, listerine gum care jahe herbal mouthwash selama 6 jam dan penurunan nilai kekerasan permukaan tertinggi terjadi kelompok listerine gum care jahe herbal dan penurunan kekerasan terendah terjadi pada kelompok akuades.

Background: Bulk-fill resin composite is a type of resin composite that not only allows minimal processing time but also minimal possibility of air trapping due to its ability to properly polymerize with the depth of cure 4-5 mm. There are several factors that affect the wear resistance of resin composite, one of which is surface hardness which is highly impacted by the acidity level (pH). Herbal mouthwash is an example of product that offers wide variety of pH content used for oral cavity treatment. Aims: This study aims to determine the impact of pH level of several herbal mouthwash on the surface hardness of bulk-fill resin composite. Methods: There were thirty two (32) bulk fill resin composite specimens prepared (Tetric® N-Ceram bulk-fill shade IVA with a diameter of 6 mm and a thick of 3 mm), which then equally divided into four different groups, based on the solution used for soaking. The first group used 20ml of distilled water that has pH of 6.78. The second group was soaked in 20 ml of pepsodent herbal natural mouthwash solution with slightly lower pH content of 6.52. Group three had 20 ml of total care lemon herbs with even lower pH content of 5.04. Lastly, the last group (group four) used 20ml listerine gum care herbal ginger solution that has the least pH content of 4.07. The soaking process for each specimen was done at temperature of 37 celcius for approximately six hours. The measurement of the specimens’ surface hardness was performed using Knoop Hardness Tester (HMV-G®: G21 Series Micro Vickers Hardness Tester Shimadzu), prior to and after the soaking process. Results: There was a decrease in the surface hardness of the Tetric® N-Ceram bulk-fill composite resin after being immersed in all solutions. The average value of surface hardness before immersion for all specimens was 37.89±0.50 KHN. While the average value of surface hardness after soaking in each group was distilled water (pH 6.78) as the control group 36.36±1.01 KHN, Pepsodent mouthwash 34.31±0.65 KHN, total care lemon herbs (pH 5.04) 32.41±0.61 KHN, mouthwash listerine gum care herbal ginger 30.68±0.43 KHN. Based on the One-Way ANOVA test and the Post Hoc Tamhane test, it can be inferred that there is a significant difference (p<0.05) among the immersion groups. Conclusion: There was a decrease in the surface hardness value of the Bulk-fill composite resin after soaking in a solution of distilled water, natural herbal pepsodent, total care lemon herbs, listerine gum care ginger herbal mouthwash for 6 hours and the highest decrease in surface hardness value occurred in the listerine gum care herbal ginger group and the lowest decrease in hardness occurred in the distilled water group."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Sarah Azkianisa
"ABSTRAK
Latar Belakang: LCU prototip dengan metode PWM-kombinasi dengan iradiansi sinar 800, 900, dan 1.000 mW/cm2 telah dibuat untuk mencegah kenaikan suhu pulpa akibat polimerisasi.
Tujuan: Menganalisis kekerasan komposit resin yang dipolimerisasi dengan LCU berbeda iradiansi sinar.
Metode: Spesimen merupakan komposit resin yang dipolimerisasi dengan LCU prototip (PWMkombinasi) beriradiansi sinar 800, 900, atau 1.000 mW/cm2 atau dengan LCU pembanding (900 mW/cm2). Kekerasan komposit resin diukur menggunakan sistem Knoop.
Hasil: Kekerasan komposit resin antar kelompok berbeda bermakna (p<0,05) kecuali yang diberi iradiansi sinar 900 mW/cm2 dari LCU
prototip dan LCU pembanding.
Kesimpulan: Kekerasan komposit resin dipengaruhi oleh iradiansi sinar dari LCU prototip. LCU prototip atau LCU pembanding dengan iradiansi 900 mW/cm2 menghasilkan kekerasan komposit resin yang sama.

ABSTRACT
Background: Prototype light curing unit (LCU) with PWM-combined light
irradiance of 800, 900, and 1.000 mW/cm2 was made to prevent the pulp temperature rise due to the polymerization. Objective: To analyze the hardness of resin composites polymerized by LCU different light irradiation.
Methods: The specimen is resin composites polymerized by prototype LCU light irradiance 800, 900, or 1.000 mW/cm2 or with comparison LCU (900 mW/cm2). Hardness of resin composite test performed by Knoop system.
Result: There is significant differences (p<0.05) among the groups except those between using the prototype LCU and comparison LCU that have irradiance of 900 mW/cm2.
Conclusions: The hardness of resin composite was influenced by the irradiance of prototype LCU. The hardness of resin composite from prototype LCU is equal to those from comparison LCU irradiance of 900 mW/cm2."
Fakultas Kedokteran Gigi Universitas Indonesia, 2014
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>