Simanungkalit, Erlin Ingrina
"Telah dilakukan kalibrasi film Gafchromic XR-RV3 yang dilakukan di Secondary Standard Dosimetry Laboratory (SSDL) BATAN untuk pengukuran dosis kulit pasien selama prosedur intervensional dipandu fluoroskopi. Film dikalibrasi di udara dan di fantom dengan dosis penyinaran 1, 5, 10, 15, 50, 100, 200, dan 300 cGy pada kualitas berkas 70, 80, 90 dan 100 kV. Persamaan faktor kalibrasi dihasilkan dari grafik hubungan nilai kerapatan optik (OD) dengan dosis. Hasil dari pengukuran faktor kalibrasi di udara dan di fantom merupakan persamaan polinomial orde kelima dengan R=1. Dalam penelitian ini juga dilakukan komisioning scanner Perfection V700 di Laboratorium Fisika Medis dan Biofisika yang bertujuan untuk menguji konsistensi scanner, homogenitas scanner, homogenitas film dan suhu ruang penyimpanan film, serta menentukan faktor fading film.
Hasil penelitian menunjukkan bahwa film memiliki komposisi yang tersebar merata pada setiap lapisannya. Berdasarkan respon scanner disarankan untuk melakukan pemindaian pada bagian pusat bedscanner namun tidak disarankan untuk melakukan pemindaian secara berulang. Selama penyimpanan dan proses pembacaan film sebaiknya suhu ruangan dijaga konstan. Berdasarkan lama waktu pemindaian film selama 72 hari, diperoleh laju penurunan nilai pixel film yaitu 314.3 pixel/pekan serta dihasilkan faktor koreksi fading y = -0.002x + 4.701 dengan R2=0.997, sebagai kompensasi waktu pemindaian yang berbeda.

Calibration of Gafchromic XR-RV3 film has been done at Secondary Standard Dosimetry Laboratory (SSDL) BATAN for measurement of patient skin dose during fluoroscopically guided interventional procedures. The film was calibrated free-in-air and on-phantom with exposure doses of 1, 5, 10, 15, 50, 100, 200 and 300 cGy at four x-ray beam qualities of 70, 80, 90 and 100 kV. Calibration factor function was generated from the graph equation between the optical density (OD) and doses. The resulted calibration factor free-in-air and on-phantom were defined in fifth order polynomial function with R=1. In this study commissioning perfection V700 scanner at the Laboratory of Medical Physics and Biophysics which aimed for consistency testing of scanner, the homogeneity of scanner, the homogeneity of film, and the temperature during storage, as well as determined the fading factor of film, was also performed.
The results shows that the composition of film layer was spread equally. Based on the response of scanner, it is recommended scan at center of flatbed but not recommended to perform repeatedly scanning. The room temperature during storage and the process of film reading should be kept constantly. Based on 72 days of the film scanning time, the decrease rate of film pixel value is 314.3 pixel/week and fading correction factor is in term of y = -0.002x + 4.701 with R2=0.997 to compensate reading time variation.
"
Depok: Universitas Indonesia, 2013
S53482
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ari Surya Miharja
"Telah dilakukan penelitian untuk menentukan karakteristik dasar dari scanner yang digunakan untuk dosimetri film radiochromic EBT2. Dalam penelitian ini digunakan scanner Vidar DosimetryPro Advantage dan Epson Perfection V700. Pengujian yang dilakukan meliputi uji konsistensi scanner, uji variasi film to film, uji uniformitas scanner, uji efek orientasi film, uji suhu ruang penyimpanan film, uji fading film dan uji noise film/scanner. Scanner diuji menggunakan film EBT2 yang telah dipapar radiasi menggunakan Linac dengan modalitas foton 6 MV. Film mempunyai 8 buah lapangan berukuran 3 cm x 3 cm dengan dosis dari 31,31 - 250,48 cGy. Software yang digunakan untuk menganalisa hasil bacaan scanner adalah ImageJ dan FilmQA Pro. Dari hasil pengujian didapatkan konsistensi Vidar mode Logarithmic lebih baik dengan standar deviasi (SD) kurang dari 0,06%, sedangkan standar deviasi Epson mencapai 0,40%. Uniformitas Vidar juga lebih baik dengan SD kurang dari 0,76% dibandingkan Epson yang mencapai 1,16%. Orientasi film cukup berpengaruh terhadap hasil bacaan, terutama pada Epson, sehingga orientasi film harus konstan selama pemindaian. Pengujian noise film/scanner menunjukkan bahwa Epson menghasilkan noise yang lebih kecil sebesar 0,10% dibandingkan Vidar yang menghasilkan 0,33%. Performa Vidar secara keseluruhan lebih bagus daripada Epson terutama saat red channel saja yang dianalisa.

Has been done measurement of basic characteristic of Vidar DosimetryPro Advantage and Epson Perfection V700 scanner based on radiochromic EBT2 film dosimetry. The tests were consist of the consistency test, film to film variation test, scanner uniformity test, effect of film orientation test, room storage temperature test, film fading test and scanner noise test. The scanners performance were tested using The scanners performance were tested using EBT2 with eight separated 3 x 3 cm2 fileds to doses ranging from 31.31 - 250.48 cGy which was irradiated using photon beam of Linac 6 MV. For evaluation, ImageJ and FilmQA Pro were used. The performance of Vidar scanner is higher in consistency and unifromity with standard deviation of measurement 0.06% and 0.76% compare with with Epson scanner with standard deviation of 0,40% and 1.16%. The film orientation effect made a big different result especially in Epson that reached 10.65% differences between portrait and landscape orientation. The scanner noise was small: 0.10% in Epson and 0.33% in Vidar. The overall measurements of Vidar was better than Epson, especially because only red channel that was analyzed.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2014
S56087
UI - Skripsi Membership  Universitas Indonesia Library
cover
Putri Diah Lestari
"Radioterapi lapangan kecil mulai banyak digunakan pada radioterapi modern seperti Intensity modulated radiotherapy (IMRT), stereotactic radiosurgery (SRS), dan Volumetric modulated arc therapy (VMAT). Akurasi terhadap pengukuran profil berkas dan percentage depth dose (PDD) menjadi kompleks karena ketidakseimbangan elektron. Oleh karena itu, film Gafchromic EBT2 digunakan untuk dosimeter radioterapi lapangan kecil karena memiliki resolusi spasial yang tinggi. Analisa dosimetri pada film Gafchromic EBT2 sangat dipengaruhi oleh penggunaan resolusi spasial citra. Penggunaan resolusi yang terlalu tinggi dapat menyebabkan noise yang cukup besar sebaliknya resolusi citra yang terlalu rendah tidak mampu menampilkan hasil analisa yang cukup akurat. Dengan demikian penggunaan resolusi citra yang optimum menjadi parameter penting dalam analisa dosimetri pada film Gafchromic EBT2. Resolusi citra yang optimum dapat ditentukan dengan melakukan uji respon terhadap variasi resolusi citra yakni : 50, 75, 100, 150, dan 240 dpi pada saat melakukan scanning film dengan Epson Perfection V700 menggunakan orientasi film landscape. Analisa dosimetri dilakukan menggunakan algoritma MATLAB dan dibandingkan dengan penelitian sebelumnya menggunakan ImageJ, Monte Carlo dan PPC untuk melihat karakteristik dosimetri terhadap penggunaan resolusi. Secara keseluruhan hasil evaluasi menunjukkan kondisi optimum resolusi citra 150 dpi diperoleh pada TPR20,10 dengan S.D. 8.10 % dan dmax dengan S.D 4.78%. Hasil evaluasi profil berkas menunjukkan resolusi optimum untuk FWHM dan Penumbra dicapai pada resolusi 75 dpi dengan S.D. 7.0 2% dan 12.43%. Hasil evaluasi VACF menunjukkan resolusi optimum dicapai pada resolusi 50 dan 75 dpi. Hasil yang diperoleh dari masing-masing parameter dosimetri memiliki kecenderungan optimum pada resolusi citra75 dpi.

Small field radiotherapy were increasing used in modern radiotherapy especially in intensity modulated radiotherapy (IMRT), stereotactic radiosurgery (SRS), and volumetric modulated arc therapy (VMAT). Accurate beam profile and percentage depth dose (PDD) measurements of such as beams were complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry small field radiotherapy because of its high spatial resolution. Spatial resolution influence dosimetric analyze for EBT2. More perturbation cause by using high spatial resolution otherwise low image spatial resolution couldn?t determined accurately. Such as, small field radiotherapy required the optimum image resolution for important parameter in dosimetric analyze EBT2. Optimum image resolution could be determine with testing dosimetric characterization to resolution response by 50, 75, 100, 150, and 240 dpi with landscape film orientation during film scanning by Epson Perfection V700. Dosimetric analyze was done by MATLAB algorithm and compare to ImageJ, Monte Carlo and PPC from prior research to evaluate dosimetry characteristic to image resolution. The results show that optimum image resolution was 150 dpi with S.D. 8.10 % and 4.78% for TPR20,10 and dmax respectively. Beam profile evaluation for FWHM dan Penumbra attained for 75 dpi with S.D. 7.0 2% and 12.43%. VACF evaluation show that optimum image resolution rich at 50 and 75 dpi. The result for each dosimetry parameter attained to optimum image resolution at 75 dpi"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2014
S54792
UI - Skripsi Membership  Universitas Indonesia Library
cover
Septi Purwaningsih
"Penelitian ini bertujuan untuk mengetahui profil dosis sinar-x Computed Tomography dengan variasi pitch menggunakan film Gafchromic XR QA2 dan TLD pada fantom kepala orang dewasa dan kepala pediatrik. Untuk tujuan tersebut dilakukan pengukuran dan analisis profil dosis di sepanjang sumbu z rotasi scan pada pusat fantom dan beberapa tepi di kedalaman 1 cm, analisis profil dosis pada posisi yang sama dengan nilai pitch yang berbeda, dan analisis profil dosis pada kepala orang dewasa dan kepala pediatrik. Dari pengukuran dan analisis data diperoleh hasil profil dosis pada scan kepala orang dewasa dan kepala anak-anak dengan nilai dosis maksimal di tengah, menurun pelan ke arah tepi dengan tendensi cenderung simetri. Profil dosis dengan variasi nilai pitch, diperoleh nilai dosis yang semakin menurun dengan bertambahnya nilai pitch. Profil dosis pada scan kepala orang dewasa memiliki nilai dosis lebih besar dari pada dosis pada scan kepala pediatrik, karena scan kepala orang dewasa menggunakan mAs lebih besar. Hasil pengukuran menggunakan TLD diperoleh data yang bersifat disktrit, namun memiliki pola distribusi dan nilai dosis yang hampir sama dengan hasil dari pengukuran menggunakan film Gafchromic. Hasil pengukuran profil dosis menggunakan film Gafchromic didapatkan grafik kontinu. Nilai dosis maksimum hasil scan didapatkan pada posisi jam 12 dan minimum pada posisi jam 6. Profil dosis pada pitch 0,75; 1 dan 1,5 mengalami fluktuasi dosis dengan amplitudo pada pitch 0,75 dan 1,5 mempunyai nilai yang lebih besar jika dibandingkan dengan amplitudo pada pitch 1.

This research aims to check pattern dose profile on the adult and pediatric head scan. Comparing result measurement dose profile along the z- axis rotation at a depth 1 cm and center phantom with variety pitch. Measurement using cylinder PMMA homogeneous phantom diameter 16 cm and 10 cm using XR QA2 Gafchromic film and TLD. Result of research get dose profile adult and pediatric head scan have same pattern, the maximum dose in the middle and tendency symmetry in the edge. Value dose proportional with value of pitch. Dose in the adult head more than dose pediatric head because dose in adult head scan using bigger mAs. Dose of TLD measurement values obtained are discrete, but has a distribution and dose values are almost the same as the measurement results in XR QA2 Gafchromic film. Result of Gafchromic film measurement is continue graphic. The maximum dose of the scan results at the 12 o'clock position and minimum at 6 o'clock position. Result of research get fluctuated dose and amplitude of pitch 0.75 and 1.5 have greater than amplitude pitch 1.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2015
T43843
UI - Tesis Membership  Universitas Indonesia Library
cover
Retno Zurma
"[ABSTRAK
Film gafchromic EBT2 dan EBT3 cocok digunakan untuk jaminan kualitas (QA) pada treatment planning systems (TPS) dan linear accelerator (LINAC) serta verifikasi radioterapi teknik IMRT dan VMAT. Namun generasi selanjutnya dari film gafchromic EBT yaitu EBT2 dan EBT3 ketika dilakukan scanning (pemindaian) menggunakan scanner flatbed masih terdapat artefak geometris yang dahulunya juga ditemukan pada film EBT sehingga memerlukan penanggulangan dan koreksi yang sesuai. Pada penelitian ini menggunakan scanner flatbed Epson expression 10000XL, Epson perfection V700 dan Mikrotek 1000XL plus yang dapat menangkap warna dengan rinci dan presisi. Perangkat lunak yang digunakan dalam koreksi ini adalah FilmQA Pro 2015. Hasil yang diperoleh yaitu Koefisien A dan B diterapkan untuk variasi posisi lateral terhadap nilai tanggapan di lokasi yang bersamaan, sehingga pengkoreksian tanggapan artifak lateral dapat dilakukan. Pada dosis maksimum nilai koreksinya <0,5% dan pada kasus <0.2%. Pada pengukuran ulang untuk setiap film, standar deviasi yang diperoleh untuk setiap film sekitar 0.19%. Pengujian dosimetri channel tunggal (merah) sebelum dan sesudah koreksi pada kasus IMRT didapatkan hampir 91% dari piksel memenuhi 3% / 3mm kriteria gamma keseluruhan dengan ambang batas dosis > 10%. Untuk pengujian kasus VMAT, film di scan dengan posisi di pusat scanner dan posisi ektrim tepi scanner, maka pengukuran di channel warna merah 4% lebih tinggi dibandingkan channel warna hijau dan biru. Rata-rata konsistensi pengukuran dosis selama daerah terkena dosis > 100 cGy adalah sekitar 21,8 cGy dan di daerah yang paling dekat dengan tepi scan window sekitar 10 mm dengan perbedaan dosis 35 cGy. Setelah dilakukan koreksi, rata-rata konsistensi dosis pada tiga channel di sekitar daerah terpapar sekitar 5,1 cGy. Perbedaan dosis antar channel sekitar 9 cGy. Hasil ini menunjukkan koreksi respon artefak lateral memang perlu dilakukan. Respon yang diukur tergantung pada posisi film pada pemindai dan dosis yang diberikan. Pengukuran pada channel warna merah menunjukkan sensitivitas yang lebih besar pada dosis rendah, sedangkan respon pada channel hijau atau biru memberikan perpanjangan jangkauan dinamis dari film ke dosis tinggi. Metode triple-channel dosimetri telah terbukti memiliki keuntungan signifikan atas single channel dosimetry dengan akurasi dosimetri yang baik.

ABSTRACT
The film of gafchromic EBT2 and EBT3 are appropriate for quality assurance (QA) to the radiotherapy technics verification of IMRT and VMAT. In the next generations of EBT which are EBT2 and EBT3, are still attained the geometrical artifacts once scanning by flatbed scanner which is used to be found on EBT film in order to need an overcome ways and an appropriate correction. This research used a flatbed scanner EPSON expression 10000XL, EPSON perfection V700 and Microtech 1000XL plus and FilmQA Pro 2015 as a software for correcting it. The result shows that coefficient A and B were applied for lateral correction artifacts responses can be made. On the maximum dose, it has correction value as much as <0,5% and in case was <0.2%. The deviation standard was approximately 0,19% on re-measure for each film. Prior to the dosimetry measurement of single channel (red) and subsequent to the correction IMRT has got almost 91% of pixel which met with gamma criteria, 3% / 3mm, with dose threshold 10% TH. In the measurement of VMAT‟s case, film scanned on the center of scanner and the extreme position of the scanner edge. Thus, measurement in the red channel was 4% higher than green and blue channel. The average of dose measurement consistency during area exposed to doses > 100 cGy is approximately 21,8 cGy and the closest area with the edge of scan window is around 10 mm at difference doses 35 cGy. After correction, the average of doses consistency was 5,1 cGy on the three channel where exposed. The distinction of doses was approximately 9 cGy among channels. This result stated that the correction of artifacts lateral response is needed to carry on. The method of triple-channel dosimetry has the significant advantage on single-channel dosimetry with a good consistency. Through escalation dose and variation of lateral position, the distinct response would be increased on single-channel which is red channel. The measurement on red channel reveals the highest sensitivity on the slight dose. Whereas, a green or blue channel response provides a dynamic range extension of film to a high dose. Thus, the method of dosimetry triple-channel has the significant contribution of single-channel evidently with a good dosimetric accuracy., The film of gafchromic EBT2 and EBT3 are appropriate for quality assurance (QA) to the radiotherapy technics verification of IMRT and VMAT. In the next generations of EBT which are EBT2 and EBT3, are still attained the geometrical artifacts once scanning by flatbed scanner which is used to be found on EBT film in order to need an overcome ways and an appropriate correction. This research used a flatbed scanner EPSON expression 10000XL, EPSON perfection V700 and Microtech 1000XL plus and FilmQA Pro 2015 as a software for correcting it. The result shows that coefficient A and B were applied for lateral correction artifacts responses can be made. On the maximum dose, it has correction value as much as <0,5% and in case was <0.2%. The deviation standard was approximately 0,19% on re-measure for each film. Prior to the dosimetry measurement of single channel (red) and subsequent to the correction IMRT has got almost 91% of pixel which met with gamma criteria, 3% / 3mm, with dose threshold 10% TH. In the measurement of VMAT‟s case, film scanned on the center of scanner and the extreme position of the scanner edge. Thus, measurement in the red channel was 4% higher than green and blue channel. The average of dose measurement consistency during area exposed to doses > 100 cGy is approximately 21,8 cGy and the closest area with the edge of scan window is around 10 mm at difference doses 35 cGy. After correction, the average of doses consistency was 5,1 cGy on the three channel where exposed. The distinction of doses was approximately 9 cGy among channels. This result stated that the correction of artifacts lateral response is needed to carry on. The method of triple-channel dosimetry has the significant advantage on single-channel dosimetry with a good consistency. Through escalation dose and variation of lateral position, the distinct response would be increased on single-channel which is red channel. The measurement on red channel reveals the highest sensitivity on the slight dose. Whereas, a green or blue channel response provides a dynamic range extension of film to a high dose. Thus, the method of dosimetry triple-channel has the significant contribution of single-channel evidently with a good dosimetric accuracy.]"
2016
T45204
UI - Tesis Membership  Universitas Indonesia Library
cover
Reza Aditya
"Pada prosedur kardiologi intervensional pasien akan menerima radiasi primer berintensitas tinggi dari berkas utama sinar-X, sehingga dosis yang didapatkan cukup besar. Dengan demikian, perlu adanya studi distribusi dosis untuk melihat bagaimana penyebaran dosis pada organ-organ tubuh, dengan menggunakam film Gachromic XR-RV3 dan TLD 100 jenis rod yang telah diletakkan di dalam fantom Rando berbentuk manusia (wanita dewasa) sebagai pengganti pasien dengan parameter eksposi : kV rata-rata = 90 kV, laju frame = 15 fps, kuat arus = 6,2 mA dengan ukuran FPD = 15 cm x 15 cm. Distribusi laju dosis terbesar berada pada radius 0 cm sampai dengan 5 cm dari pusat lapangan, kemudian turun drastis pada radius 7,5 cm dan sudah tidak terdeteksi nilai laju dosis radius 10 cm. Untuk nilai laju dosis terbesar terdapat pada bagian pusat lapangan yaitu sebesar 6,345 ±0,097 mGy/min. Pada pengukuran laju dosis di beberapa Organ at Risk (OAR) dengan menggunakan Film Gafchromic XR-RV3 dan TLD 100 rod sebagai dosimeter didapatkan laju dosis pada Film Gachromic XR-RV3 dan TLD 100 rod dengan nilai terbesar terdapat pada organ jantung bagian tengah berturut-turut yaitu 2,742±0.029 mGy/min dan 2,791±0.161 mGy/min. Perbedaan nilai laju dosis antara Film Gachromic XR-RV3 dengan TLD 100 rod berkisar antara 0,53 % sampai dengan 13,80%.

In interventional cardiology procedures patients will receive primary radiation of high intensity X-rays beam, so that dose received by the patient is relatively high. Thus, the dose distribution studies needed to see how the spread of the dose to the organs of the body, using Gachromic XR - RV3 film and TLD 100 type rod that has been placed in phantom Rando (adult women) as a replacement for a patient with parameters: average kV = 90 kV, frame rate = 15 fps, electric currents = 6.2 mA with FPD size = 15 cm x 15 cm. The distribution of the largest dose rate is at a radius of 0 cm to 5 cm from the center of the field, then dropped away at a radius of 7.5 cm and had no detectable dose rate value at radius of 10 cm. For the largest dose rate values are at the center of the field is about 6.345 ± 0.097 mGy / min. In the measurement of the dose rate in some organs at risk ( OAR ) using Gafchromic XR - RV3 film and TLD 100 rod obtained dose rate at Gachromic XR-RV3 film and TLD 100 rod with the largest value found in the central part of the heart organ ie 0.029 ± 2.742 mGy / min and 2.791 ± 0.161 mGy / min, respectively. The difference between the value of the dose rate Gachromic XR-RV3 film with TLD 100 rod ranged from 0.53% to 13.80%."
2013
S54336
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ahcdriany
"Prospek penggunaan kurva kalibrasi dalam perhitungan dosis antar modalitas menjadi tantangan baru dalam penggunaan film gafchromic EBT3. Tujuan utama penelitian ini adalah membandingkan hasil perhitungan dosis pada pesawat brakhiterapi sumber Ir-192 dan Co-60 dengan menggunakan fungsi kalibrasi pada brakhiterapi Ir-192, brakhiterapi Co-60, teleterapi LINAC 6 MV dan Co-60. Pengukuran dilakukan dengan melakukan kalibrasi pada keempat modalitas menggunakan film gafchromic EBT3. Hasil kalibrasi berupa fungsi kalibrasi digunakan dalam mengkonversi densitas optik pada hasil perencanaan dengan dosis perskripsi 2 Gy, 3 Gy dan 6 Gy pada tiga buah aplikator silinder dengan fantom akrilik pada kedalaman 5 mm, 6 mm dan 7 mm. Hasil menunjukkan kurva kalibrasi keempat modalitas tampak hampir berimpit dengan pola polinomial. Koefisien korelasi R2 pada modalitas menunjukkan linearitas kalibrasi berturut-turut sebersar 0,9991; 0,9989; 0,9981 dan 0,990. Nilai dosis terukur tampak berkuran pada jarak yang lebih besar dari pusat aplikator ke fantom. Hasil perhitungan gamma indeks bernilai lebih kecil pada toleransi yang lebih kecil dengan nilai minimum dan maksimum sebesar 74% dan 98,4%.

The prospect of using calibration curves in calculating intermodality doses is a new challenge in the use of EBT3 gafchromic films. The main objective of this study was to compare the dose calculations on the Iridium (Ir)-192 and Cobalt (Co)-60 brachytherapy by using the calibration function of Ir-192 brachytherapy, LINAC 6 MV, Co-60 brachytherapy, and Co-60 teletherapy. The calibration functions were obtained from the exposure of the EBT3 gafchromic film with dose references of 0 to 10 Gy by using the calibration function of Ir-192 brachytherapy, LINAC 6 MV, Co-60 brachytherapy, and Co-60 teletherapy. The dose references of the treatment planning system (TPS) were 2 Gy, 3 Gy and 6 Gy. The experiment was conducted with three cylindrical applicators. R2 of the LINAC 6 MV, Ir-192 brachytherapy, Co-60 brachytherapy, and Co-60 teletherapy are about 0.9991, 0.9989, 0.9981 and 0.990 respectively. The use of the Co-60 teletherapy calibration function shows the greatest discrepancy. Measured dose values ​​appear to be reduced at a greater distance from the center of the applicator to the phantom. The results of the calculation of the gamma index are smaller at a smaller tolerance. The minimum and maximum value of 74% and 98.4% respectively."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Harry Kurniawan
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2009
S29030
UI - Skripsi Open  Universitas Indonesia Library
cover
Eka Aulia Ardyanti
"Penelitian ini membahas batas ketebalan yang diperlukan dalam penggunaan antiscatter grid pada pesawat Siemens Artis Zee yang berada di RS Kanker ldquo;Dharmais rdquo; Jakarta. Pesawat Siemens Artis Zee memiliki fitur fluoroskopi dengan mode yang dapat diatur yaitu low fluoroscopy, medium fluoroscopy dan high fluoroscopy. Pasien direpresentasikan dengan menggunakan fantom Polymethyl Methacrylate PMMA dengan variasi ketebalan 7 ndash;22 cm interval 1 cm. Dosis radiasi diukur pada titik dosis entrans kulit dan dosis transmisi, sedangkan kualitas citra menggunakan parameter resolusi spasial dan SNR, sehingga didapatkan parameter FOM sebagai hubungan antara dosis radiasi dengan kualitas citra SNR . FOM digunakan untuk menentukan batas ambang penggunaan antiscatter grid pada mode fluoroskopi berdasarkan ketebalan fantom. Hasil yang didapatkan untuk batas penggunaan antiscatter grid dimulai maksimum pada mode low fluoroscopy pada ketebalan 11 cm, mode high fluoroscopy pada ketebalan 16 cm dan pada mode medium fluoroscopy tidak disarankan penggunaannya karena hanya meningkatkan dosis tanpa meningkatkan kualitas kualitas citra.

The study discusses the threshold of thickness required for antiscatter grid use on Siemens Artis Zee at ldquo Dharmais rdquo National Cancer Center, Jakarta. The device has adjustable modes of low, medium, and high fluoroscopy. Patients are represented by Polymethyl Methacrylate PMMA phantom with a thickness variation of 7 22 cm of 1 cm interval. The dose metrics was measured as the entrance skin dose ESD and the transmission dose, while the image quality metric employed being spatial resolution and SNR, leading the result to FOM as squared SNR per dose. The FOM bridged dose and image quality to determine threshold of antiscatter grid usage on fluoroscopy based on fantom thickness. As a result, antiscatter grid are recommended to be used for objects 11 cm and thicker on the use of low fluoroscopy mode, and 16 cm and thicker objects on high fluoroscopy mode. In medium fluoroscopy mode, no threshold was yielded due to tube current being higher than other modes, hence it is recommended to remove the antiscatter grid during the use of the medium fluoroscopy mode."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2017
S68086
UI - Skripsi Membership  Universitas Indonesia Library
cover
Pamungkas Hudigomo
"Telah dilakukan penelitian yang bertujuan untuk mengimplementasikan film Gafchromic XR-RV3 untuk verifikasi dosis radioterapi pada IMRT dan VMAT. Evaluasi dosis pada target ditentukan dengan meletakkan film Gafchromic XRRV3 dan EBT2 padqa slab fantom Rando Alderson. Percobaan dilakukan dengan menggunakan Varian Clinac Trilogy, Inc. Proses simulasi terlebih dahulu dilakukan pada fantom Rando Alderson bagian thorax dan pelvis di CT simulator Phillips, Inc. Dua kasus perencanaan IMRT dan VMAT dibuat menggunakan TPS Eclipse ver. 10. Film Gafchromic yang telah dipapar kemudian dipindai menggunakan scanner Epson Perfection V700 ke dalam format tagged image file (.TIFF) dengan 72 dpi dan RGB 48 bit yang kemudian dianalisis menggunakan algoritma in-house yang telah dikembangkan oleh penelitian sebelumnya. Dalam penelitian ini dilakukan perbandingan pengukuran distribusi dosis pada film Gafchromic XR-RV3 dan EBT2 untuk mendapatkan dosis rata-rata dalam bentuk kurva histogram. Hasil penelitian ini memiliki persentase kesalahan terhadap dosis preskripsi pada kasus kanker prostat sebesar -4.85% pada film Gafchromic EBT2 dan -1.94% pada film Gafchromic XR-RV3 dengan teknik penyinaran IMRT, sedangkan untuk teknik penyinaran VMAT sebesar -4.48% pada film Gafchromic EBT2 dan -7.47% pada film Gafchromic XR-RV3. Di sisi lain, persentase kesalahan terhadap dosis preskripsi pada kasus kanker paru-paru dengan teknik penyinaran IMRT adalah 14.47% pada film Gafchromic EBT2 dan -4.37% pada film Gafchromic XR-RV3, sedangkan untuk teknik penyinaran VMAT sebesar 51.64% pada film Gafchromic EBT2 dan -28.07% pada film Gafchromic XR-RV3.

The research aims to implement Gafchromic XR-RV3 films in order to verify the dose of radiotherapy on IMRT and VMAT. The evaluation of targeted dose is determined by putting films of Gafchromic XR-RV3 and EBT2 on Rando Alderson slab fantom. The experiment was performed with Varian Clinac Trilogy, Inc. The simulation process was initially conducted on thorax and pelvis on Phillips Inc.’s CT Simulator. Two cases of IMRT and VMAT plans were made using Eclipse TPS ver. 10. Exposed Gafchromic films then scanned using Epson Perfection V700 into (.TIF) format in 72 dpi and RGB 48 bit which was analyzed by in-house algorithm that had been developed on a previous research. The comparison between EBT2 and XR-RV3 Gafchromic films were used to obtain average dose in the form of histogram curve. The percentage of errors in the case of prostate cancer toward the planned dose were -4.85% in EBT2 Gafchromic films and -1.94% in the XR-RV3 Gafchromic films on IMRT technique, whereas for VMAT were -4.48% on EBT2 Gafchromic films and -7.47% on XR-RV3 Gafchromic films. On the other hand, the percentage of errors in the case of lung cancer toward the planned dose with IMRT technique were 14.47% on EBT2 Gafchromic films and -4.37% on XR-RV3 Gafchromic films, while for VMAT were 51.64% on EBT2 Gafchromic films and -28.07% on XR-RV3 Gafchromic films.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2014
S57739
UI - Skripsi Membership  Universitas Indonesia Library