Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 12193 dokumen yang sesuai dengan query
cover
New York: American Society of Civil Engineers, 1990
R 621.31922 DES
Buku Referensi  Universitas Indonesia Library
cover
New York: American Society of Civil Engineers, 1988
R 621.31922 GUI
Buku Referensi  Universitas Indonesia Library
cover
New York: American Society of Civil Engineers, 1991
R 621.31922 GUI (1)
Buku Referensi  Universitas Indonesia Library
cover
Gaylord, Edwin H.
New York: McGraw-Hill, 1972
624.182 GAY d
Buku Teks  Universitas Indonesia Library
cover
Macginley, T. J.
London : E. & F.N Spon, 1981
624.182 1 MAC s
Buku Teks  Universitas Indonesia Library
cover
Abdul Aziz Rohman Hakim
"Setelah 30 tahun dioperasikan, kinerja menara pendingin RSG-GAS mengalami penurunan. Perlu dilakukan pemodelan perpindahan panas dan massa yang terjadi di dalam menara pendingin. Pemodelan perpindahan panas dan massa dilakukan pada bagian fill menara pendingin. Penelitian ini mengkaji perubahan temperatur air dan udara serta rasio kelembaban udara dari sisi masuk sampai sisi keluar fill. Kajian dilakukan dengan pendekatan Kloppers, Klimanek dan Analogi. Hasil perhitungan kemudian dibandingkan dengan data desain menara pendingin. Hasil analisis menunjukkan bahwa pendekatan Kloppers dan Klimanek 39,26 di bawah desain dan pendekatan Analogi 0,9 di atas desain. Pendekatan Analogi memberikan hasil perhitungan paling mendekati data desain.

After 30 years of operation, the performance of RSG GAS cooling towers has decreased. It is necessary the heat and mass transfer modeling that occurs inside the cooling tower. Modeling of heat and mass transfer is done on the cooling tower fill section. This study examines changes in water and air temperature and air humidity ratio from the inlet side to the outlet fill. The study was conducted using Kloppers, Klimanek and Analogical approach. The results are then compared with the cooling tower design data. The results of the analysis show that the Kloppers and Klimanek approach is 39.26 under the design and the Analogical approach is 0.9 above the design. Analogical approach gives the most closed result of the design data.
"
Depok: Fakultas Teknik Universitas Indonesia, 2018
T51016
UI - Tesis Membership  Universitas Indonesia Library
cover
I Gusti Agung Ayu Desy Wulandari
"Sistem pendingin dengan tenaga surya adalah teknologi dengan peluang yang besar dalam upaya mengurangi biaya terutama pada pemakaian listrik, dampak terhadap lingkungan, dan emisi gas rumah kaca, salah satunya adalah teknologi absorption chiller dengan bantuan energi surya untuk mendukung kerja pada komponen generator. Pada penelitian ini, simulasi termodinamika dilakukan sebagai tahapan awal desain sistem single-effect ammonia-water absorption chiller yang dimodelkan menggunakan media pendingin udara lingkungan (air-cooled) dan sumber panas berasal dari sistem kolektor termal surya, disesuaikan dengan aplikasi rumah tangga (residential) berkapasitas pendinginan rendah di negara beriklim tropis Indonesia. Kinerja sistem berupa nilai COP yang diperoleh dari simulasi sistem berdasarkan parameter input yang telah disesuaikan dengan batasan permasalahan penelitian adalah sebesar 0.554. Karakterisasi yang dilakukan terhadap dua parameter input pada sistem menunjukkan bahwa kenaikan temperatur kondensasi meningkatkan temperatur outlet generator, namun menurunkan nilai COP sistem. Hal ini bertentangan dengan pengaruh temperatur evaporasi yang menurunkan temperatur outlet generator, namun COP sistem menjadi meningkat. Sedangkan peningkatan kadar air pada solution menurunkan COP sistem. Jumlah solar collector dengan tipe ETC yang diperlukan untuk sistem single-effect ammonia-water absorption chiller adalah sebanyak lima buah kolektor dengan rangkaian seri, dan dengan kapasitas rata-rata masing-masing kolektor sebesar 1,52 kW.

Solar-powered cooling system is a technology with great opportunities to reduce operation costs, especially on electricity consumption, impact on the environment, and greenhouse gas emissions, one of which is by the use of absorption chiller technology with the help of solar energy to support the work of generator components. In this study, the thermodynamic simulation was carried out as an early stage in designing a single-effect ammonia-water absorption chiller system which is modeled using air-cooled system and the heat source comes from solar thermal collector system, adapted for residential applications with low cooling capacity in the tropical country of Indonesia. System performance in the form of COP value obtained from the system simulation based on input parameters that have been adjusted to the limits of the research problem is 0.554. System characterization was carried out on the two input parameters in the system shows that the increase in condensation temperature increases the generator outlet temperature but decreases the COP value of the system. This is contradicting to the effect of the evaporation temperature which decreases the generator outlet temperature, but the COP system increases. Meanwhile, increasing the water content of the solution decreases the COP of the system. The number of solar collectors with ETC type required for the single-effect ammonia-water absorption chiller system is five collectors in series arrangement, with an average collector capacity of 1.52 kW."
Depok: Fakultas Teknik Universitas Indonesia, 2021
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Mrazik, Augustin
New York: Ellis Horwood, 1987
691.7 MRA p
Buku Teks  Universitas Indonesia Library
cover
Krishnamachar, B.S.
New Delhi: Tata McGraw-Hill, 1978
624.182 KRI d (1)
Buku Teks  Universitas Indonesia Library
cover
Dian Rahmawati
"ABSTRAK
Penelitian ini membandingkan konvergensi elemen pelat lentur triangular yaitu MITC3, DKMT, DST-BL, dan DST-BK. Keempat elemen tersebut sama-sama memiliki 9-derajat kebebasan namun dengan formulasi regangan lentur dan regangan geser yang berbeda. Masing-masing elemen akan diuji pada beberapa kasus homogen isotrop, yaitu kasus pelat bujursangkar, pelat melingkar, pelat Razzaque, dan pelat Morley, dengan berbagai variasi ketebalan dan mesh. Keluaran uji numerik pelat homogen isotrop yang dibandingkan berupa perpindahan, momen arah-x dan momen arah-y, serta energi. Selain kasus homogen isotrop, masing-masing elemen diuji pada kasus komposit, yaitu berupa uji dari Srinivas. Dari keempat elemen yang diuji, elemen MITC3 memiliki tingkat konvergensi yang lebih lambat dibandingkan dengan elemen lainnya. Dari segi waktu komputasi, elemen MITC3 dan DKMT memiliki waktu komputasi yang lebih singkat dibandingkan dengan elemen DST-BL dan DST-BK.

ABSTRACT
This research compare the convergence of triangular plate bending element MITC3, DKMT, DST BL, and DST BK. These elements has 9 degrees of freedom with different formulation for bending strain and shear strain interpolation. Each element is tested for several benchmark problem of isotropic condition square plate problem, circular plate problem, Razzaque skew plate, and Morley plate. The output of homogen isotropic problem is vertical displacement, moment in x direction, moment in y direction, and energy. For composite condition, numerical test is conducted for Srinivas test. In most benchmark test, MITC3 has slower convergence compared with the other elements. But on the other side, MITC3 and DKMT elements have relatively short computational time compared with DST BL and DST BK. "
Depok: Fakultas Teknik Universitas Indonesia, 2018
T50588
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>