Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 15586 dokumen yang sesuai dengan query
cover
Seeds, Michael A.
Singapore : Brooks/Cole Cengage Learning, 2013
523.2 SEE s
Buku Teks SO  Universitas Indonesia Library
cover
San Francisco : Addison-Wesley, 2002
523.2 SOL
Buku Teks SO  Universitas Indonesia Library
cover
Koupelis, Theo
Sudbury, Mass. : Jones and Bartlett, 2011
523.2 KOU q
Buku Teks SO  Universitas Indonesia Library
cover
New York: John Wiley & Sons, 1976
521.54 ORI
Buku Teks SO  Universitas Indonesia Library
cover
Koupelis, Theo
Sudburry, Mass.: Jones and Bartlett, 2011
532KOUQ001
Multimedia  Universitas Indonesia Library
cover
Pradipta Mahatidana
"Pada skripsi ini dilakukan rancang bangun sistem embedded simulator surya yang dapat menguji kinerja sel surya berupa tegangan rangkaian terbuka (Voc), arus hubung singkat (Isc), fill factor (FF), karakteristik kurva I-V, daya keluaran (Pout) dan efisiensi. Sistem ini memiliki modul pengukur tegangan, arus, intensitas cahaya, dan temperatur yang dibangun dengan memanfaatkan komponen yang ekonomis. Sistem ini memiliki resolusi pengukuran Voc, Isc, intensitas cahaya, dan temperatur berturut-turut sebesar 0,244 mV, 1,21 µA, 1 lux, dan 0,1 °C. Sistem ini dilengkapi dengan perangkat lunak untuk pengendali simulator surya dan sebagai datalogger.

This thesis presents a design and construction of the embedded system of solar simulator to test the performance of solar cell such as open circuit voltage (Voc), short-circuit current (Isc), fill factor (FF), I-V curve characteristic, output power (Pout) and efficiency. This system has a measurement module of voltage, current, light intensity, and temperature built with cost effective materials. This system has a measurement resolution of 0,244 mV, 1,21 µA, 1 lux, and 0,1 °C for Voc, Isc, light intensity, and temperature, respectively. This embedded system has an included software for controlling solar simulator and datalogging."
Depok: Fakultas Teknik Universitas Indonesia, 2013
S57492
UI - Skripsi Membership  Universitas Indonesia Library
cover
Djoko Purnomo
"Quantitative information about solar radiation in agro-forestry system in Indonesia is relatively limited. To study the amount of solar radiation below forest trees stand, a survey based research was conducted from october 2002 to February 2003 in Central Java, Indonesia. The location of the survey were chosen based on the kinds of trees forests. They were Purwodadi (teak, mahogany and sonokeling production forest), Karanganyer- Purworejo (pines production forest) and Klaten (semolina and yucca as conservation forest). The decrease in the relative's Irradiation Fraction (RIF) under the trees was found realted to the increased of the tree aging, adjusted to the exponential decrease model (RIF=1.25e -0,18 x). The RIF under tree canopy was clearly explained by diameter on the breast height diameter of trunk (DBH) divided by the half of tree row spacing (2D/(X+Y) therefore the RIF was formulated as e 0.2829 (2D/(X+Y)."
Indonesian Center for Biotechnology and Biodiversity Research and Development (UNS), {s.a.}
JBB 2 (2011) (1)
Artikel Jurnal  Universitas Indonesia Library
cover
I Made Wikananda Supartha
"Indonesia mengalami peningkatan konsumsi listrik karena pertumbuhan populasi. Sebagian besar listrik yang dihasilkan menggunakan sumber daya batubara. Muncul urgensi untuk mengembangkan Energi Baru dan Terbarukan (EBT) agar dampak dari emisi karbon tidak meningkat. Salah satu alternatif EBT yang hadir di Indonesia adalah tenaga surya, namun sayangnya masih memiliki adopsi yang rendah di Indonesia meskipun potensinya besar. Penelitian ini bertujuan untuk menganalisis alternatif kebijakan dalam rangka meningkatkan adopsi rooftop PV untuk mengurangi emisi karbon. Melalui metode sistem dinamis, model dikonstruksi untuk menguji tiga alternatif kebijakan.
Hasil penelitian menunjukkan bahwa kebijakan net metering merupakan kebijakan yang dapat memberikan stimulus paling baik pada rumah tangga untuk mengadopsi rooftop PV. Pada skenario kebijakan ini, jumlah rumah tangga yang mengadopsi rooftop PV adalah sebesar 5.346. Selain itu, kebijakan ini juga dapat menekan jumlah emisi paling besar, yakni adalah sebesar 1.037 juta kgCO.

Indonesia experiences rapid increase in electricity consumption due to its increasing population. Coal is still become dominant contributor in Indonesias energy mix. The development of new and renewable energy becomes an important issue to reduce the carbon emission. One of the alternatives of new and renewable energy is solar photovoltaic. Unfortunately, the amount of adopters of this type of energy is still low, despite of its great potential. The aim of this research is to analyze policy alternatives to increase the adoption of rooftop PV in order to reduce carbon emission. System dynamics model is used to simulate three policies alternatives.
Result shows that net metering policies is the best alternative to be implemented, since its produces the highest result in terms of amount of household that adopts rooftop PV, which gives value 5.346 household. More than that, net metering acts as the best policy to gives the highest amount of avoided carbon emission (1.037 million kgC
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ardian Wirata
"Solar thermal collector merupakan sebuah alat yang dapat mengubah energi matahari menjadi energi panas. Energi panas ini kemudian digunakan untuk menaikkan temperatur air. Penelitian ini diawali dengan mernbuat sistem rangkaian seri-pararel dengan mempergunakan sistem katup beserta peralatan ukur seperti termokopel dan flow meter. Rangkaian ini dibuat dari 8 panel kolektor pelat datar. Rangkaian yang dibuat merupakan rangkaian tertutup jenis aktif dan dapat dibuat menjadi berbagai macam konfigurasi. Pada pengujian kali ini digunakan empat jenis rangkaian kombinasi seri pararel. Konfigurasi pertama adalah rangkaian Seri dengan laju aliran sebesar 10.5 liter/menit. Konfigurasi kedua adalah rangkaian Seri dipararel dengan laju aliran sebesar 15 liter/menit. Konfigurasi ketiga adalah rangkaian pararel dipararel dengan laju aliran sebesar 15,3 liter/menit. Konfigurasi keempat adalah rangkaian Pararel diseri dengan laju aliran sebesar 13,3 liter/menit. Data yang diperoleh adalah temperatur akhir dari empat rangkaian di atas. Konfigurasi pertama dapat menaikkan ternperatur air hingga 45°C. Konfigurasi kedua dapat menaikkan temperatur air hingga 37°C Konfigurasi ketiga dapat menaikkan temperatur air hingga 41°C. Konfigurasi keempat dapat menaikkan temperatur air hingga 43°C. Dari hasil analisa didapat bahwa temperatur akhir dari solar thermal collector adalah radiasi matahari dan laju aliran, melalui perbandingan hasil perhitungan teoritis didapat bahwa proses percobaan yang dilakukan benar, hal ini terbukti dengan trend line temperatur akhir yang sama.

Solar thermal collector is a device that transform soiar radiation into heat and then use the heat to increases the water temperature. The research began by making the serie-pararell configuration with valves mechanism and aiso the measurement instruments such as thermocoupie and flow meter. We made 4 different configuration from 8 Fiate-Plat collector. The 1st configuration is Serie configuration with the maximum flow rate's 10.5 litre/minute. The 2nd configuration is Serie-Pararell configuration with the maximum fiow rate ’s 15 titre/minute. The 3th configuration is Pararell-Pararell configuration with the maximum flow rate's 15.3 litre/minute. The 4m configuration is Pararell-Serie configuration with the maximum flow rate's 13.3 litre/minute. Data obtained from the experiment is a output temperature from 4 of the configuration that can be made. The 1st configuration can increases the water temperature up to 45°C The 2nd configuration can increases the water temperature up to 37°C. The 3th configuration can increases the water temperature up to 41°C. The 4th configuration can increases the water temperature up 43°C. The anaiisys results refer to the increases ofthe output temperature depends on the solar radiation and the flow rate. Compared to the teoriticai result, it can be conclude that the experiment is correct. It's proven by the similarity ofthe output temperature's trend' line."
Depok: Fakultas Teknik Universitas Indonesia, 2005
S37787
UI - Skripsi Membership  Universitas Indonesia Library
cover
"The study was conducted between September and October 2006 in various sites both inside and outside and outside the taklong Island national marine Reserve (TINMAR),southern Guimars,Philippines,to immediately conduct a rapid 3-month assessment of the impact of the solar I il spill incident which occurred in August 11,2006 in southern Guimaras...."
Artikel Jurnal  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>