Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 162282 dokumen yang sesuai dengan query
cover
Bambang Suryawan
"There are some parameters that identify the quantity of air i.e. dry bulb temperature, wet bulb temperature, humidity ratio, relative humidity, and dew point temperature. These parameters can be used to construct a new formula in order to determine the effectiveness of air processing equipment When air passes through an evaporative pad its dry bulb temperature will decrease. it can be lowered to 5°C, when its wet bulb temperature is maintained constant. Due to the air temperature is higher than the water temperature, so then the heat will flow from the air to water. U' the temperature of flow air assumed remain constant, this hear is to be used to evaporate the water drops. So, it is caused increasing of the air humidity ratio. This research found out that the humidity ratio increased until 2. 22-gram water/ kg dry air.
"
Depok: Fakultas Teknik Universitas Indonesia, 2001
JUTE-15-2-Jun2001-166
Artikel Jurnal  Universitas Indonesia Library
cover
cover
Doni Bakar
"Peninjauan kinerja dari peralatan processing udara (termasuk evaporative cooler) selalu didasarkan pada kualitas dan kuantitas dari udara yang dihasilkan. Kualitas udara blsa dilihat dari kebarsihan sehingga tidak merusak kesehatan. Sedangkan kuantitas udara ditlnjau dari besaran parameter udara basah seperti temperatur dry bulb, temperatur wet bulb, rasio kelembaban, derajat kejenuhan udara, kelembaban relatff, dan temperatur pengembunannya. Dengan menggunakan besaran-besaran tersebut dapat dibuat formulasi untuk menentukan efektivitas dari peralatan yang digunakan.
Pada penelitian ini dilakukan pengujian terhadap direct evaporative cooler jenis crossflow buatan Muntars. Pengambilan data temperatur dilakukan secara komputerisasi menggunakan Data Acquisition Control System HP 3497A secara kompensasi soflware menggunakan bahasa HTBasic. Pengujian dilakukan pada dua jenis variasi yaitu variasi perlakuan terhadap udara dan air. Pada valiasi udara dilakukan pada tiga tingkat kecepatan udara dan mefakukan pemanasan awalterhadap udara.
Dari hasil pangujian diparoleh udara yang dialirkan pada media evaporatif menghasilkan penurunan temperatur bola kering dan penambahan kandungan uap air. Pada pengujian ini evaporative cooler berhasil menurunkan temperatur bola kering udara hingga 5°C dan penambahan kandungan uap air sebesar 2,22 gr uap air/kg udara kering apabila tidak dilakukan pamanasan awal lerhadap udara masuk. Dengan melakukan pemanasan awal terhadap udara diperoleh penurunan temperature bola kering yang lebih besar lagi yaitu 8°C dengan penambahan kandungan uap air 2,61 gr uap air/kg udara kering. Sedangkan temperature bola basah udara pada saat sebelum dan setelah melewati evaporative cooler cenderung konstan."
Depok: Fakultas Teknik Universitas Indonesia, 2000
S37188
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ridwan
"Proses perlakuan terhadap udara dengan mengatur suhu, kelembaban, kebersihan, pengaluran kecepatan, dan penyisihan partikel dari uap beracun telah dimanfaatkan manusia baik untuk kenyamanan (comfort) maupun untuk keperluan industri. Terdapat beberapa metode atau cara yang dikenai dalam pengkondisian udara, salah satu diantaranya adalah dengan menggunakan sistem pendinginan evaporatif (evaporative cooling). Dengan metode pendinginan evaporatif udara dikondisikan agar temperatur yang berupa kalor sensibel diturunkan suhunya dengan menaikan kelernbaban dalam bentuk kalor iaten (kandungan uap air).
Untuk menurunkan temperatur dan menaikkan kelembaban udara maka diperlukan media yang dapat memberikan perpindahan kalor dan massa dari udara dengan media tersebut. Pada pendinginan evaporatif air pengisi disirkulasikan oleh suatu pompa sehingga media evaporatif (wet-pad) menjadi basah atau mengandung air. Pada saat udara dialirkan maka terjadi kontak anmra aliran udara dari fan dengan air sirkulasi pada wet-pad sehingga terjadi evaporasi dari air ke aliran udara.
Pada penelitian ini dilakukan pengujian terhadap suatu Direct evaporative Cooler jenis aliran silang (crossflow) buamn Munters. Data-data berupa temperatur diukur dengan menggunakan termokopel dan data acquisition control system HP 3497A. Dari hasil pengujian dan pengolahan data diperoleh bahwa pada kondisi temperatur air sirkulasi normal ( 25 °C), terjadi penurunan temperatur bola kering udara rata-rata 3.4 °C clan kenaikan rasio kelcmbaban 1,25 gr uap air/kg udara kering pada temperatur bola basah relatif konstan. Pada temperatur air sirkulasi dingin (dibawah 20 °C) teriadi penurunan temperatur bola kering 6,2 °C, temperatur bola basah 1.9 °C dan rasio kelembaban udara juga turun 0,3 gr uap air/ kg udara kering. Dan pada saat temperatur air sirkulasi dipanaskan (diatas 30 °C) maka terjadi kenaikan balk temperatur maupun kelernbaban udara. Tempcramr bola kering naik 1°C, bola basah 4 °C serta rasio kelembaban naik sebesar 6,6 gr uap air / kg udara kering."
Depok: Fakultas Teknik Universitas Indonesia, 2001
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Suranto
Depok: Fakultas Teknik Universitas Indonesia, 2000
S37222
UI - Skripsi Membership  Universitas Indonesia Library
cover
Budi Asmawan
"Konsep dan penggunaan dari evaporative cooling telah dikena! sejak lama. Metoda pendinginan ini efislen dalam penggunaan energi, efektif da!am biaya dan ramah lingkungan. Direct evaporative cooling merupakan proses pertukaran kalor secara adiabalis. Udara yang dialirkan melalui air yang akan diuapkan memberikan kalornya dan air menyerap ka1or ini &ebagai kalor penguapan. Oalam pengujian ini akan dilakukan pengujian unjuk kerja dengan menggunakan crossflow evaporative cooler FA3-85.060.060·111AO. Data-data berupa temperatur bola kering (dry bulb temperature) dan temperatur bola basah (wot bulb temparature) pada sisimasuk udara Juar, slsiudara masuk pada wet pad, sisi udara keluardry pad dan temperatur air diukur dengan menggunakan tennokopel dan data acquisition HP3497A. Variasi Kondisi dalam penguj!an adalah temperatur air normal, temperatur air dingin dan temperatur air panas.
Pada kondisi temperatur air normal (± 24° C) dihasilkan penurunan temperatur bola kering udara rata rata konstan dan rata-rata penambahan kandungan uap air dalam udara adalah 2 g uap air/kg udara kerfng. Pada kondisi ini direct evaporative cooler menunjukkan fungsi sebagai pendingin(cooler) dengan efektivitas rata-rata sebesar 98,15%. Pada kondisi temperatur air dingin (kurang dari 20°C) dlhasilkan penurunan temperatur bola kering rata rata basah rata rata 2.5°C dan penurunan nilai rasio kelembaban rata rata. 28°C dan penurunan nilai rasio kelembaban rata-rata 2 gr air/kg dry air. Pada kondisi ini direct epavorative cooler menunjukkan fungsi sebagai pendingin (cooler) dan pengeringan dengan efektivitas rata-rata sebesar 50,46%."
Depok: Fakultas Teknik Universitas Indonesia, 2000
S37229
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ferdiansyah
"Pengkondisian udara merupakan salah satu faktor penting yang mendukung perindustrian. Pengkondisian udara dapat berupa penurunan moisture (kandungan uap air) dari udara, dimana untuk keper!uan itu dikembangkanlah berbagai janis dehumidifier (pengering udara), selah satunya adalah rotary desiccant dehumidtfter (pengenng udara sistem desikan putar). Skripsi ini mempresentasikan eksperimen dan analisa terhadap efektiVItas, suatu ukuran kemampuan penurunan kelembaban (rasio kelembaban) udara proses, dengan memperhatlkan pengaruh temperatur udara yang memasuki regenerasi terhadapnya.
Penelitian dilakukan dengan menguji rotary desiccant dehumidifier bermerek Munters Avfuktare MD 16 yang menggunakan UCI (Lithium Chloride) berwujud padat sebagai media penyerap uap air. Dehumidifier ini memiliki roda desikan yang berdiameter 535 mm dan tebal 100 mm yang berputar dengan kecepatan 10 rph.
Eksperimen tersebut menghasilken data temperatur bola kering dan temperatur bola basah pada keadaan masuk dan keluar untuk aliran udara proses dan regenerasi Kemudian data tersebut diolah dengan menggunakan program CATH (Computer Aided Thermodynamics) untuk mendapatkan sifat­sifat termodinamik. Dari sifat sifat termodinamik itu, dikembangkanlah perhitungan terhadap efektifitas pengering udara tersebut.

Air conditioning is one of significant factors wh1ch supports industry. The process can be lowering moisture content of the air, that for the purpose, many kinds of dehumidifiers have been developed, one of them is rotary desiccant dehumidifier. This paper presents experiment and analyzing of the effectiveness, the value of dehumidifier's capability for lowering process air's humidity, especially when its influenced by the changing of the temperature of regeneration air before entering the desiccant.
The experiment was dor1e by using rotary desiccant dehumidifier of Munters Avfuktare MD 16 which has LiCI (Lithium Chloride) for its solid adsorbent This dehumidifier has rotary bed which has 535 mm diameter and 100 mm thickness and is rotated in 10 rph.
The experiment gave information about dry bulb and wet builb temperatures of process and regeneration airflows, when they were entering and leaving the desiccant In order to gain the values of thermodynam1cs parameters for every state, the information can be manipulated by using CATH (Computer Aided Thermodynamics) software. And then the value of effectivity can be calculated."
Depok: Fakultas Teknik Universitas Indonesia, 2000
S37184
UI - Skripsi Membership  Universitas Indonesia Library
cover
Tulus Nugroho
"Dalam proses pengeringan seperti dalam proses pengolahan industri makanan, spray drying, evaporative cooling dan pembakaran bahan bakar cair, laju penguapan tetesan mempunyai peranan penting. Sehingga diperlukan pengetahuan tentang sifat laju penguapan air yang terkandung di dalamnya akibat pengaruh temperatur, laju aliran, konsentrasi dan kelembaban terhadap laju penguapan. Dari sini akan diperlihatkan korelasi dari bilangan Reynolds (Re), Prandtl (Pr), Schmidt (Sc), Nusselt (Nu), dan Sherwood (Sh). Penelitian ini bertujuan mengetahui adanya perpindahan kalor dan massa serta korelasi antara data pengujian dengan menggunakan metode rumus model umum, metode stagnan film, dan pendekatan model baru dari metode stagnan film oleh E. A. Kosasih.

In the drying process such as in food processing industry, spray drying, evaporative cooling and combustion of liquid fuel, the quick drop of evaporation plays an important role. Therefore it takes a knowledge about the nature of the water quick evaporation along with all the contents due to the effect of temperature, quick current, concentration and humidity of quick evaporation. Here it shows a correlation from reynold's number ( Re ), Prandtl's number ( Pr ), Schmidt's number (Sc), Nusselt's number ( Nu ) and Sherwood's number ( Sh ), This research is to find out the existing of heat and mass transfer and correlation between data experiment using the general formula method, stagnant film method and a new phenomenological stagnant film by Kosasih E.A ( 2006 )"
Depok: Fakultas Teknik Universitas Indonesia, 2009
S50945
UI - Skripsi Open  Universitas Indonesia Library
cover
Piazza, Wieldy
"Dalam dunia industri proses pengeringan sangatlah penting, untuk itu perlu dilakukan penelitian tentang proses pengeringan. Dari sekian banyak model tentang laju penguapan tetesan, perlu diketahui model yang paling dekat korelasinya. Penelitian ini bertujuan untuk membandingkan model stagnan film dan model modifikasinya (oleh E.A.Kosasih) dengan acuan model analogi Ranz-Marshall. Juga untuk mengetahui pengaruh perbedaan konsentrasi larutan dan kelembaban udara pada bilangan Sherwood dan Nusselt.
Penelitian ini menggunakan alat berupa nozzle yang berisi larutan. Setelah larutan diteteskan pada termokopel, kemudian dialirkan udara yang bervariasi kecepatan, temperatur dan kelembabannya. Setelah dianalisa akan didapat hubungan antara bilangan Reynold (Re), Prandtl (Pr), Schmidt (Sc), Nusselt (Nu) dan bilangan Sherwood (Sh). Model modifikasi ternyata mempunyai korelasi yang lebih kuat dibandingkan dengan model stagnan film. Nilai bilangan Sherwood dan Nusselt dari model modifikasi juga lebih dekat dengan analogi Ranz-Marshall dibandingkan dengan model stagnan film.

Drying process is very crucial in industry, that's why research on drying process is needed. From so many models about droplet evaporation rate, the closest correlation need to be known. The objective of this research is to compare stagnant film model and the modification model (by E.A.Kosasih) by referencing to Ranz-Marshall analogy. And also to find out about the effect of difference in solution concentration and air humidity to Sherwood and Nusselt number.
This research is using a nozzle filled with solution. After the solution is injected on thermocouple, then air flow is given with some variations of velocity, temperature and humidity. After being analized, the relations between Reynold number (Re), Prandtl (Pr), Schmidt (Sc), Nusselt (Nu) and Sherwood number (Sh) will be found. The modification model has stronger correlation than stagnant film model. The values of Sherwood and Nusslet number from modification model also closer to Ranz-Marshall analogy than stagnant film model.
"
Depok: Fakultas Teknik Universitas Indonesia, 2009
S50793
UI - Skripsi Open  Universitas Indonesia Library
cover
Mohammad Bintang Fikri
"Dewasa ini, menjaga kondisi udara tetap berada pada zona nyaman dengan menggunakan pendingin konvensional membutuhkan biaya yang tidak murah, terutama pada ruangan yang luas dan semi terbuka. Evaporative cooler yang menggunakan material yang tidak membahayakan lingkungan maupun kesehatan dan berbiaya rendah dapat menjadi alternatif untuk menjaga lingkungan tetap sehat dan nyaman. Tujuan dari percobaan ini adalah untuk menentukan dan membandingkan kinerja evaporative cooler yang dimodifikasi dengan heat pipe dan tanpa heat pipe. Heat pipe diletakkan di bagian sebelum dan sesudah cooling pad dan berfungsi sebagai indirect stage. Bagian evaporator dari heat pipe diletakkan sebelum cooling pad dan bagian kondensor diletakkan di dalam penampung air tambahan. Sedangkan heat pipe kedua diletakkan setelah evaporative cooler untuk mendinginkan udara dari luar.
Hasil penelitian menunjukkan bahwa saturation efficiency dari kedua sistem meningkat seiring dengan peningkatan suhu udara pada saluran masuk dan menurun seiring dengan penurunan kelembaban relatif. Saturation efficiency juga menurun seiring dengan peningkatan kecepatan udara. Hasil penelitian juga menunjukkan bahwa saturation efficiency evaporative cooler yang dimodifikasi menggunakan modul heat pipe pertama lebih tinggi daripada direct evaporative cooler. Penambahan heat pipe sebelum evaporative cooler dapat meningkatkan saturation efficiency direct evaporative cooler hingga 1,03 tanpa penambahan konsumsi listrik. Dengan susunan heat pipe sebelum evaporative cooler dengan direct evaporative cooler mampu menurunkan temperatur hingga 19.15 °C, sedangkan sengan susunan heat pipe setelah evaporative cooler hanya mampu menurunkan temperatur hingga 3,2 °C namun memiliki kelembaban relatif yang tidak terlalu tinggi.

Nowaday, keeping air condition in a comfort zone using conventional coolers become expensive, especially in large and semi-open spaces. Evaporative cooler which offer a healthy, non-harmful materials, and low cost can be an alternative to keep environment healthy and comfortable. The objective of this experiment is to determine and compare the performance of direct evaporative cooler embedded with heat pipes and without heat pipes. The heat pipe is placed in the section before and after the cooling pad as a precooler and an indirect stage. The evaporator part of the heat pipe is placed before the cooling pad and the condenser section is placed in an additional water reservoir.
The results show that the saturation efficiency of both systems increases along with increasing inlet air temperature and decreases with decreasing relative humidity. Saturation efficiency also decreases with increasing air flowrate. The results also show that the modified saturation efficiency evaporative cooler uses a heat pipe higher than the direct evaporative cooler. The addition of a heat pipe can increase the saturation efficiency of the direct evaporative cooler to 1.03 without adding more energy consumption. The multistage direct evaporative cooler with heat pipe before cooling pad can reduce temperature up to 19.15 °C while the multistage direct evaporative cooler with heat pipe heat exchanger after cooling pad could not reduce temperature as high as the other system but it does not increase relative humidity as high as the other system.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
T54095
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>