Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 53230 dokumen yang sesuai dengan query
cover
Fakultas Teknik Universitas Indonesia, 2000
T40678
UI - Tesis Membership  Universitas Indonesia Library
cover
Agarwal, B.K.
Berlin: Springer-Verlag, 1991
543.62 AGA x
Buku Teks  Universitas Indonesia Library
cover
Jenkins, Ron
New York : John Wiley & Sons, 1988
543.57 JEN x
Buku Teks  Universitas Indonesia Library
cover
Aldi Purwanto
"

Kanker merupakan salah satu penyakit dengan angka kematian tertinggi di dunia. Kanker adalah penyakit ketika sel-sel abnormal tumbuh tidak terkendali yang dapat menyerang organ tubuh yang berdampingan atau menyebar ke organ lain. Untuk mendiagnosis kanker paru-paru dapat dilakukan dengan pengambilan gambar rontgen, CT scan, dan biopsi jaringan paru. Tujuan dari penelitian ini adalah untuk memprediksi apakah pasien menderita kanker paru-paru atau tidak, dengan menggunakan data gambar CT scan mereka. Oleh sebab itu, dalam penelitian ini digunakan ekstraksi fitur dari gambar CT scan sebagai data untuk mengklasifikasi kanker paru-paru. Data yang digunakan merupakan data gambar CT scan yang didapat dari SPIE-AAPM Lung CT Challenge 2015. Gambar CT scan paru-paru dengan ukuran 512x512 sebelumnya dilakukan pre-processing 2D crop dan filtering. Dengan mengekstraksi fitur dari data gambar seperti ukuran nodul, Gray Level Co-occurrence Matriks (GLCM), dan Local Binary Pattern (LBP) dapat mengubah data gambar menjadi numerik. K-Fold Cross Validation digunakan untuk memisahkan data menjadi data training dan data testing. Fuzzy C-Means (FCM) dan Fuzzy Kernel C-Means (FKCM) diterapkan untuk pengklasifikasian. Didapatkan performa FKCM lebih baik dibandingkan FCM, dengan rata-rata akurasi 75.60%, precision 83.05%, dan specificity 87.80%. Oleh karena itu, penambahan kernel pada metode Fuzzy C-Means dapat meningkatkan performa dari metode tersebut


Cancer is one of the diseases with the highest mortality rate in the world. Cancer is a disease when abnormal cells grow out of control that can attack the body's organs side by side or spread to other organs. To diagnose lung cancer can be done by taking x-ray images, CT scans, and lung tissue biopsy. The purpose of this study is to classify whether patients have lung cancer or not using their CT scan image data. Therefore, in this study feature extraction from CT images was used as data to classify lung cancer. The data used in the form of CT scan image obtained from SPIE-AAPM Lung CT Challenge 2015. Previously, a CT scan of the lung with a size of 512x512 was pre-processed 2D crop and filtering. By extracting features from image data such as nodule size, Gray Level Co-occurrence Matrix (GLCM), and Local Binary Pattern (LBP) can convert image data to numeric. K-Fold Cross Validation is used to separate data into training data and testing data. Fuzzy C-Means (FCM) and Fuzzy C-Means (FKCM) are applied for classification. FKCM performed better than FCM, with 75.60% average accuracy, 83.05% average precision, and 87.80% average specificity. Therefore, adding a kernel to the Fuzzy C-Means method can improve the performance of the method.

"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
Jonathan
"Metode penelusuran sinar ( ray tracing ) merupakan sebuah metode yang banyak digunakan didalam tomografi untuk memperoleh sebuah pemodelan mengenai struktur bawah permukaan, adapun dalam proses pembuatan program penelusuran sinar ini mengunakan asumsi bahwa gelombang tersebut merambat secara sferis dan dalam penjalarannya tidak mengalami atenuasi dan dianggap sangat ideal atau tanpa noise. Dalam penelitian ini, data seismik 2D (dimensi) dibuat dalam empat tipe yaitu model datar tiga lapisan, model patahan, model graben, model antiklin, dan model datar berlapis banyak, adapun metode numerik yang digunakan dalam penjalaran gelombang tersebut didasarkan pada persaman eikonal dan selanjutnya solusi dari persamaan eikonal tersebut diselesaikan dengan metode finite-difference (beda hingga). Hasil dari penelusuran sinar tersebut akan menghasilkan model struktur bawah permukaan berupa snapshot, shot record sintetik, dan struktur geologi dalam bentuk wavelet. Hasil dari ketiga hal ini kemudian dianalisa.

Ray tracing method is a method widely used in tomography to obtain a modeling of the subsurface structure. As for the process of making this program we use the assumption that the wave propagate in spherical form and is considered ideal. In this research, 2D seismic data was made in five types: flat model with three layer, fault models, Graben model, anticline model and a flat model with many layer, as for the numerical methods used in the wave propagation is based on the eikonal equations and subsequent solution eikonal equation is solved by finite-difference method and the results of the ray tracing will produce a model of subsurface such a snapshot, synthetic shot record, and the subsurface structure, and the results of these three is then analyzed."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
S1650
UI - Skripsi Open  Universitas Indonesia Library
cover
Khairul Mar`ie
"Computed Tomography (CT) Scanner merupakan modalitas pencitraan tubuh tiga dimensi. Untuk observasi organ tubuh yang bergerak, selain menggunakan Singlesource CT (SSCT) telah dikembangkan pula Dual-source CT (DSCT) yang dilengkapi dengan sumber sinar-X primer dan sekunder. Posisi kedua sumber DSCT membentuk sudut 90°, dan pada saat akuisisi citra keduanya berputar 90°. Dengan demikian proses akuisisi citra organ tubuh yang bergerak dapat dilaksanakan dalam waktu yang relative singkat. Berbagai pengujian untuk menganalisis kualitas citra biasanya dilakukan menggunakan fantom. Berbagai macam jenis fantom yang telah dibuat dengan menggunakan material ekuivalen jaringan telah banyak dikembangkan. Dalam meningkatkan studi fantom untuk menganalisa kualitas citra CT scan yang meliputi pengukuran detectability, noise, dan resolusi spasial pada penelitian ini dilakukan suatu konstruksi dan pengembangan fantom desain khusus (in-house) yang terdiri dari beberapa material ekuivalen jaringan. Fantom terdiri dari 3 bagian. Fantom in-house yang dibuat digunakan untuk analisis kualitas citra dan dikhususkan untuk QC pada DSCT dan SSCT. Fantom in-house yang di buat telah dilakukan uji coba dan dapat digunakan untuk evaluasi kualitas citra dari DSCT dan SSCT. Hasil pengukuran detektabilitas, menunjukkan DSCT mampu mendeteksi objek dengan kontras rendah pada objek pipa silinder berukuran 2 mm. Pengukuran SNR pada citra SSCT didapatkan terjadinya peningkatan nilai SNR seiring dengan pertambahan mAs, dan nilai SNR objek pada bagian perifer tidak selalu sama daripada center dikarenakan proses scanning helical. Pengukuran resolusi spasial menunjukkan nilai MTF 10% dari DSCT lebih rendah di bandingkan dengan dengan SSCT. Perbedaan mAs yang digunakan tidak berpengaruh terhadap MTF 10% yang dihasilkan.

Computed Tomography (CT) Scanner is a three-dimensional body imaging modality. Instead of using Single-Source CT (SSCT), the observation of moving organs could be performed also by Dual-Source CT (DSCT) that has been developed recently. DSCT is equipped with primary and secondary x-ray sources. The position of the two sources DSCT forms an angle of 90°, and at the time of image acquisition, both rotate 90°. This new technology of CT could reduce the scan time so that the process of image acquisition of a moving body can be carried out in a relatively short time. A special phantom would be needed to perform several testing procedures for analyzing the image quality. Many phantom modules were designed with tissue-equivalent materials. The proposed in-house phantom was aimed to enhance the phantom study in order to analyze the CT scan image quality: detectability, noise and spatial resolution. The phantom was special designed and constructed with several tissue-equivalent materials. The phantom was consist of three part modules. This in-house phantom can be used for image quality analyzis for both quality control (QC) of DSCT and SSCT. The in-house phantom was tested and image quality evaluation of DSCT and SSCT can be succesfully performed with the phantom. The detectability measurement shows that DSCT was able to detect the object with low contrast in cylidrical pipe object with 2 mm diameter. The SNR measurement for noise test in SSCT image shows that the SNR tends to rise proportional to the mAs increment. The SNR value of the object in periferal region seems to be higher compared to the SNR value from the central region, due to the helical scanning process. The highest SNR value shows the lowest noise. The spatial resolution shows that 10% MTF value from DSCT is lower than SSCT. It means that SSCT represents the better spatial resolution compared to DSCT. The mAs difference during this work was not affect the 10% MTF value produced.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
T55298
UI - Tesis Membership  Universitas Indonesia Library
cover
Afif Ariqulfikri
"EDXRF memungkinkan analisis cepat dan tidak merusak baik untuk analisis kuantitatif maupun analisis kualitatif. Analisis XRF kuantitatif dilakukan dengan menggunakan prosedur komparatif, dimana sampel yang tidak diketahui untuk dianalisis dibandingkan dengan sampel yang bertindak sebagai referensi standar. Sebelum melakukan pengukuran, prosedur kalibrasi harus dilakukan. Persiapan spesimen standar untuk kalibrasi harus dilakukan dengan sangat hati-hati dan dengan cara yang sama seperti sampel yang tidak diketahui yang akan diuji. Untuk mendapatkan proses kalibrasi yang tepat, seseorang perlu memahami prinsip-prinsip tentang sinar-X, pengetahuan dasar tentang pengaturan khusus instrumen, dan beberapa teori tentang metode pengujian. Sifat fisik sampel dan beberapa pengaturan khusus instrumen, seperti sumber sinar-X, voltase daya tabung yang diterapkan, atau waktu pengukuran, dapat memengaruhi jumlah elemen yang diukur dengan pemindaian XRF. Proses kalibrasi akan membentuk kurva kalibrasi yang akan digunakan alat untuk menghitung analisis unsur. Jika terjadi kesalahan selama proses kalibrasi, kesalahan tersebut dapat memengaruhi pengukuran sampel yang tidak diketahui nantinya. Tesis ini dilakukan untuk meningkatkan akurasi mesin EDXRF yang tersedia di lab ST dengan memodifikasi kondisi pengujian dan mengubah energi mesin, untuk menghasilkan kondisi pengukuran terbaik meskipun dengan keterbatasan mesin. Dengan demikian, tugas akhir ini bertujuan untuk mendapatkan kondisi yang dapat menghasilkan pengukuran yang paling akurat pada baja.

EDXRF enables quick and non destructive analysis for both quantitative analysis or qualitative analysis. Quantitative XRF analysis is accomplished using a comparative procedure, where the unknown samples to be analyzed are compared with samples that act as standard references. Before conducting the measurement, a calibration procedure must be performed. The preparation of the standard specimens for calibration must be carried out with great care and in the same manner as the unknown sample that will be tested. In order to obtain a proper calibration process, one needs to understand the principles regarding X-rays, basic knowledge regarding the instrument-specific settings, and several theories regarding the methods of testing. Physical properties of the sample and several instrument-specific settings, such as the X-ray source, applied voltage of the tube power, or measurement time, can affect the element counts measured by scanning XRF. The calibration process will form a calibration curve, which the instrument will use to calculate the elemental analysis. If errors occur during the calibration process, they can affect the measurement of the unknown sample later. This thesis is conducted to improve the accuracy of an EDXRF machine that is available at the ST lab by modifying the test conditions and altering the machine energy, to generate the best measurement condition despite the limitations of the machine. By doing so, this bachelor's thesis aims to obtain conditions that could produce the most accurate measurements on steel."
Depok: 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Adlan Mizan
"ABSTRAK
Telah berhasil dilakukan sintesis semikonduktor Cu2ZnSnS4 CZTS sebagai absorber semikonduktor yang dilakukan dengan metode kimiawi menggunakan pelarut dan ligand etanolamine untuk memudahkan reaksi dengan sulfur. Deposisi CZTS yang dipilih adalah menggunakan metode dip-coating. Metode ini dilakukan diatas substrat kaca soda lime glass yang kemudian di drying pada 200 C dan annealing pada 550 C dengan atmosfir argon. Kristalinitas CZTS hasil uji X-ray diffraction yang tinggi serta hasil energy dispersive spectroscopy yang sesuai dengan literatur. Celah pita yang didapatkan pada CZTS adalah 1,36 eV.Lapis CZTS kemudian dilapisi dengan Cadmium Sulfide CdS dengan metode chemical bath deposition menggunakan perbedaan konsentrasi [S]:[Cd] dan temperatur deposisi yang berbeda. Lapisan CdS diuji pola difraksinya menggunakan X-ray diffraction dan UV-Vis spectroscopy. Kristalinitas meningkat pada setiap penambahan konsentrasi [S]:[Cd] dengan pola diffraksi yang paling mirip dengan referensi adalah perbandingan 5 dan semua sampel memiliki rata-rata celah pita 2,26 eV. Meningkatnya temperatur pada CdS dapat merubah antarmuka antara CZTS dengan CdS dimana pada temperatur 70 C menunjukan interface yang paling baik dengan ditemukannya adanya Antarfasa antara CZTS dan CdS. Hasil optik dari CZTS/CdS menunjukan perbandingan konsentrasi [S]:[Cd]= 5 dapat meningkatkan performa absorbsi dari CZTS. Antarmuka pada temperatur selain 90 C diduga dapat meningkatkan sifat reflektansi dari lapisan CdS yang menurunkan transmitansi

ABSTRACT
The semiconductor synthesis of Cu2ZnSnS4 CZTS has been successfully carried as a semiconductor absorber by chemical method using solvents and ethanolamine ligand. The dip coating method has been selected for CZTS deposition. This method carried out on a soda lime glass substrate, then dried at 200 C and annealed at 550 C with an argon atmosphere. X ray diffraction test and electron dispersive spectroscopy analysis confirm the crystallinity and chemcial composition of CZTS. The bandgap obtained in CZTS is 1.36 eV. The CZTS layer is then coated with CdS by chemical bath deposition method using different concentration S Cd and different deposition temperature. The CdS layer diffraction pattern and optical properties are checked using X ray diffraction and UV Vis spectroscopy. It was shown that crystallinity increased at each addition of S Cd concentration with the diffraction patterns confirm that CdS are present at the ratio of 5 and all samples had an average bandgap 2.26 eV. Increased temperatures in CdS can alter the interface between CZTS and CdS where at 70 C it shows the best interface with the discovery of an interphase between CZTS and CdS. Optical results from CZTS CdS showed a concentration ratio of 5 to improve the absorption performance of CZTS. Interfaces at temperatures other than 90 C are thought to increase the reflectance properties of the CdS layer that inhibit the transmittance properties of CdS."
2018
T50930
UI - Tesis Membership  Universitas Indonesia Library
cover
Oxford: Pergamon Press, 1982
543.62 ADV
Buku Teks  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>