"Penerapan tegangan tinggi AC pada sistem tenaga listrik menimbulkan beberapa gejala, salah satunya korona. Salah satu dampak yang ditimbulkan korona pada sistem tenaga listrik adalah kenaikan nilai distorsi harmonik dari gelombang sumber. Korona dapat ditemukan pada saluran transmisi, gardu induk dan gardu distribusi. Pengujian untuk mendeteksi korona pada kubikel model dengan melihat perubahan nilai total distorsi harmonik (THD) dilakukan untuk mengurangi dampak negatif yang ditimbulkannya. Hasil pengujian menyatakan bahwa nilai THD semakin meningkat saat terjadinya korona. Perubahan jarak penghantar dengan kubikel dan besar diameter kawat penghantar juga mempengaruhi besar perubahan THD.

Application of AC high voltage in power system cause several effect, such as corona. One of impact caused by corona in power system is increasing the value of harmonic distortion of power source. Corona mostly developed in transmission lines, substations and distribution substation. Experiment to detect corona in cubicle model by observing the gradient of total harmonic distortion (THD) is conducted to reduce the negative impact caused by them. Results show that THD's value increasing during corona phenomenon. Changes in distance between electrode and cubicle as well as diameter of electrode influence the THD's values."
Depok: Fakultas Teknik Universitas Indonesia, 2010
S51234
UI - Skripsi Open  Universitas Indonesia Library
cover
Nadir M. Aljaidi
"Korona merupakan salah satu fenomena yang diakibatkan oleh penerapan tegangan tinggi arus bolak-balik pada sistem tenaga listrik. Fenomena korona biasanya terjadi pada saluran transmisi, gardu induk, dan gardu distribusi. Fenomena korona menimbulkan beberapa masalah pada sistem tenaga listrik, salah satunya yaitu menyebabkan kenaikan distorsi harmonik dari gelombang tegangan. Untuk itu dilakukan pengujian pada kubikel dengan melihat perubahan nilai dari distorsi harmonik total (THD) gelombang tegangan. Dari pengujian tersebut didapatkan bahwa nilai dari THD semakin meningkat saat terjadi korona. Peningkatan nilai THD ini disebabkan oleh peningkatan distorsi harmonik orde 9. Nilai THD ini juga dipengaruhi oleh diameter kawat penghantar serta jarak antar kawat penghantar dengan kubikel.

Corona is phenomenon which caused by AC High voltage applications on electric power system. Corona phenomenon mostly developed in transmission lines, substations, and distribution substation. Corona phenomenon presence many problems on electric power system, one of the effect is increase harmonic distortion of voltage wave. For it was examined by observing changes in the value of total harmonic distortion of the voltage wave. From these tests, it was found that the value of THD increases during corona. The increasing value of THD is caused by an increase in 9th order harmonic distortion. The THD is also influenced by diameter of the wire and distance between the wire and cubicles."
Depok: Fakultas Teknik Universitas Indonesia, 2010
S51223
UI - Skripsi Open  Universitas Indonesia Library
cover
Don Bosco
"Korona adalah suatu peristiwa kegagalan listrik yang merupakan gejala awal terjadinya peristiwa flashover (lepas denyar). Aktivitas korona pada kubikel tegangan tinggi merupakan sumber utama terjadinya degradasi dan kegagalan pada isolasi. Peristiwa korona ini ditandai dengan adanya bunyi dengung, bau ozon, dan kilatan cahaya seragam pada permukaan elektroda. Pendeteksian terhadap korona pada kubikel dapat dilakukan dengan menganalisa bunyi dengung yang dihasilkan. Korona pada kubikel disebabkan karena adanya ketidakidealan pada celah udara yang memisahkan dua elektroda. Tegangan kritis awal terjadinya korona pada model kubikel dipengaruhi oleh beberapa hal seperti gradient tegangan, bentuk elektroda pada kubikel, jarak elektroda dengan badan kubikel, kelembaban udara, tekanan udara, dan kondisi suhu udara. Hal-hal tersebut menyebabkan ketidakseragaman medan pada elektroda sehingga dapat mempercepat terjadinya proses korona.
Dalam skripsi ini akan ditunjukkan simulasi dengan menggunakan MATLAB untuk menghitung tegangan kritis awal munculnya korona pada model kubikel. Hasil simulasi dibandingkan dengan hasil pengujian langsung di laboratorium. Dari hasil perbandingan diketahui bahwa simulasi sudah mewakili kondisi sebenarnya. Dengan menggunakan simulasi akan dibuktikan bahwa factor bentuk elektroda sangat mempengaruhi besarnya tegangan kritis.
Corona is electrical breakdown that constitute the beginning of flashover. The corona activity at high voltage cubicle is the main cause of degradation and isolation failure. Corona was showed by buzzing sound, ozone scent, and uniform purplish light at the electrode surfaces. Corona detection at cubicle can be done by analyze the buzzing sound. The corona at cubicle can be caused by non-ideal air gap that separate two electrodes. Critical voltage of corona at cubicle model was influenced by many things, such as voltage gradient, electrode form, gap between electrode and cubicle body, humidity, air pressure, and temperature. All of that matter can cause non-uniform electric field which can quicken corona phenomena.
This minithesis will showed how to approximate critical voltage of corona at cubicle model using simulation in MATLAB. The simulation result will be compared by the result of direct experiment at laboratory. The comparison result shows that the results in simulation represent the actual condition. Using the simulation will be proved that electrode shape influence the critical voltage of corona.
"
2008
S40504
UI - Skripsi Open  Universitas Indonesia Library
cover
Yanuar Mohamad Marda
"Kebutuhan manusia akan energi membawa pengaruh yaitu perubahan iklim terutama dikarenakan dikarenakan oleh pemakaian sumber energi yang menghasilkan limbah gas rumah kaca. Energi elektrokimia berpeluang menjadi sumber energi alternatif yang lebih ramah lingkungan. Aluminum Al 2024 memiliki potensi untuk menghasilkan energi melalui proses elektrokimia. Tesis ini bertujuan untuk mempelajari, mengamati dan memahami pengaruh pasangan galvanik, elektrolit dan adanya transpor massa terhadap timbulnya beda potensial dan arus listrik pada proses elektrokimia dengan menggunakan logam aluminum Al 2024 sebagai anoda. Aluminum Al 2024 dihubungkan secara galvanik dengan elektroda Cu dan graphite yang lebih elektropositif. Pasangan galvanik tersebut diuji dengan menggunakan elektrolit HCl dan NaCl pada beberapa konsentrasi dengan perlakuan agitasi terhadap elektrolit yang berbeda. Pengukuran keluaran berupa rapat arus listrik dan beda potensial dilakukan untuk mengamati daya listrik yang dihasilkan. Data yang dihasilkan dipelajari secara kualitatif dan kuantitatif. Penggunaan elektrolit HCl menghasilkan arus yang lebih besar dibanding penggunaan NaCl. Penggunaan NaCl menghasilkan beda potensial yang lebih besar dibanding penggunaan HCl. Pasangan galvanik memiliki pengaruh yang besar dalam menentukan daya listrik. Tingkat agitasi berpengaruh besar pada keluaran arus listrik tetapi tidak berpengaruh signifikan pada keluaran beda potensial. Konsentrasi larutan berpengaruh dalam menentukan beda potensial namun kurang berpengaruh dalam menentukan besarnya arus listrik. Nilai pH elektrolit kurang memiliki pengaruh signifikan dalam menentukan beda potensial maupun arus listrik. Pengaruh konsentrasi elektrolit, jenis pasangan galvanik, pH dan agitasi secara bersama terhadap beda potensial adalah 69,4%, yang artinya adalah 69,4 % nilai beda potensial dapat dijelaskan oleh parameter-parameter tersebut . Urutan tingkat pengaruh terhadap beda potensial dari yang terbesar sebagai berikut: pasangan galvanik; konsentrasi larutan ; pH; dan agitasi. Pengaruh konsentrasi elektrolit, jenis pasangan galvanik, pH dan agitasi secara bersama terhadap rapat arus listrik adalah 37%. Urutan tingkat pengaruh terhadap arus listrik dari yang terbesar sebagai berikut: agitasi; pasangan galvanik; pH; dan konsentrasi larutan.

Human need for energy influences climate change, mainly due to the use of energy sources that produce greenhouse gas. Electrochemical energy has the opportunity to become a more environmentally friendly alternative energy source. Aluminum Al 2024 has the potential to produce energy through electrochemical processes. This thesis aims to study, observe and understand the influence of galvanic couple, electrolytes and the presence of mass transport on the electric potential and electric currents in electrochemical processes using Al 2024 aluminum metal as anodes. Aluminum Al 2024 is galvanically connected to the more electropositive Cu and graphite electrodes. The galvanic couple was tested using HCl and NaCl electrolytes at several different concentrations with agitation treatment of different electrolytes. Output measurements in the form of electric current density and voltage are carried out to observe the electrical power produced. The resulting data was studied qualitatively and quantitatively. The use of the HCl electrolyte produces a greater current than the use of NaCl. The use of NaCl produces a greater voltage than the use of HCl. The galvanic couple has a significant influence in determining electrical power. The level of agitation has a significant effect on the electric current output but does not have a significant effect on the voltage output. The concentration of the solution has an influence in determining the voltage but has less influence in determining the magnitude of the electric current. The pH value of the electrolyte does not have a significant influence in determining the voltage or electric current. The influence of electrolyte concentration, type of galvanic couple, pH and agitation together on the voltage is 69.4%, which means that 69.4% of the voltage value can be explained by these parameters. The order of the level of influence on the voltage from the largest is as follows: galvanic pair; solution concentration; pH; and agitation. The influence of electrolyte concentration, type of galvanic couple, pH and agitation together on the electric current density is 37%. The order of levels of influence on electric current from greatest is as follows: agitation; galvanic couple; pH; and solution concentration."
Depok: Fakultas Teknik Universitas Indonesia, 2024
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Tomy Adiansyah
"Penelitian teori ini bertujuan untuk menginvestigasi pengaruh medan listrik dan medan magnet terhadap transpor elektron pada molekul DNA poli(dA)-poli(dT). Mekanisme transpor elektron dimodelkan menggunakan pendekatan hamiltonian ikatan kuat dengan melibatkan pengaruh temperatur dan frekuensi gerak memutar. Arus listrik yang melalui DNA dihitung menggunakan formula Landauer-Buttiker dengan perhitungan probabilitas transmisi menggunakan pendekatan fungsi green. Kemudian, faktor eksternal medan listrik dilibatkan mengikuti model Miller-Abraham. Sedangkan faktor eksternal medan magnet, dimodelkan menggunakan model Pierls. Hasil yang diperoleh menunjukan bahwa pengaruh medan listrik berdampak pada pelemahan probabilitas transmisi. Sebaliknya, pengaruh medan magnet memiliki dampak pada peningkatan arus listrik maksimum. Kemudian secara keseluruhan, frekuensi gerak memutar menyebabkan peningkatan pada probabilitas transmisi.

This theoretical study aims to investigate the electric field and magnetic field influence on electron transport through DNA poly(dA)-poly(dT). The electron transport mechanism is modeled by the tight-binding Hamiltonian approach involving temperature and twisting motion frequency. The accumulation of electron current flowing through DNA is calculated using Landauer-Buttiker Formula from transmission probability obtained using green function. Then, the external disturbance, electric field, is considered using the Miller-Abraham model. On the other sides, the magnetic field effect is modeled by Pierls model. The results show that the electric field causes decrement on transmission probability. In contrast, magnetic field increases transmission probability. In contrast, the magnetic field increases the current. Furthermore, twisting motion frequency causes higher transmission probability."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Andrew Setiawan
"Partial discharge telah menjadi salah satu masalah yang sering terjadi pada peralatan dan peralatan listrik belakangan ini. Epoxy Resin sebagai sistem isolasi telah digunakan dalam penelitian ini karena keserbagunaannya. Penelitian ini memiliki dua tujuan yaitu menemukan pengaruh variasi frekuensi harmonik dan tingkat distorsi harmonik terhadap partial discharge sebagai tujuan yang pertama, sedangkan yang kedua adalah kita mencoba untuk menemukan efek rongga udara pada insulasi epoxy resin terhadap partial discharge.
Penelitian ini menggunakan dua jenis epoxy resin tanpa rongga udara dan dengan adanya rongga udara sebagai objek uji. Ada dua faktor yang divariasikan selama penelitian ini, yaitu distorsi frekuensi dan tingkat total distorsi harmonik. Pekerjaan ini memanfaatkan MATLAB sebagai alat untuk menghasilkan sinyal dan pemrosesan data. Terdapat empat parameter yang dianalisis untuk penelitian ini, meliputi Partial Discharge Inception Voltage, luas area partial discharge, tingkat pengulangan partial discharge dan distribusi fase partial discharge.
Hasil penelitian menunjukkan bahwa peningkatan distorsi frekuensi mengarah pada peningkatan luas area partial discharge dan tingkat pengulangan selama 1 siklus, sementara itu mengurangi Partial Discharge Inception Voltage. Adapun untuk distorsi harmonik total, tingkat THD yang lebih tinggi berkontribusi terhadap penurunan Partial Discharge Inception Voltage, tetapi meningkatkan luas area partial discharge. Dalam hal tingkat pengulangan, partial discharge lebih banyak terjadi pada kisaran 61° -120° untuk wilayah positif dan pada 241° -300° untukwilayah negatif. Selain itu, keberadaan rongga udara meningkatkan luas areapartial discharge dan tingkat pengulangan selama 1 siklus. Namun, menurunkan PDIV.

Partial discharge has been one of the problems that frequently occurs on electrical devices and equipment lately. Epoxy resins as an insulation system has been utilized in this research due to its versatility. This research has two objectives as finding the influence of variation of harmonic frequency and harmonic distortionlevel to partial discharge being the first one, while the second is we try to find the effects of air cavities in epoxy resin insulation to partial discharge.
It used twotypes of epoxy resins without void cavity and with the presence of void cavity asthe test object. There were two factors that were varied during this research, which were frequency distortions and total harmonic distortion levels. This workmade use of MATLAB as a tool to generate signals and data processing. Four parameters were analyzed for this research, those include Partial Discharge Inception Voltage, apparent charge area, partial discharge repetition rate andpartial discharge phase distribution.
The results showed that the increase offrequency distortion leads to the increase of apparent charge area and repetition rate for 1 cycle, while it decreases the Partial Discharge Inception Voltage. As forthe total harmonic distortion, higher levels contributes to the decrease of Partial Discharge Inception Voltage, but increases the apparent charge. In terms of charge numbers, the charges occurred more at the range of 61° 120° for the positivesequence and at 241° 300° for the negative sequence. In addition, the presence ofvoid cavity increases the apparent charges and repetition rate for 1 cycle. However, it decreases the PDIV.
"
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rafdi Hidayat
"Pengelasan pada industri kapal di Indonesia cenderung masih banyak menggunakan metode las SMAW. Dengan menggunakan metode pengelasan GMAW yang memiliki deposition rate dan efisiensi yang tinggi, proses pengelasan dapat dilakukan lebih cepat. Dengan meningkatnya kecepatan dan kuat arus las, rentan terjadinya kemungkinan distorsi pada pengelasan. Salah satu penyebab terjadinya distorsi adalah heat input yang tidak merata pada material las, sehingga muncul perbedaan suhu antara area las dan area yang telah dilas dan mengakibatkan tegangan pada area yang telah mendingin dan regangan pada area yang dilas. Dengan demikian, diperlukan heat input yang tepat agar hal tersebut tidak terjadi, distorsi sudut menyebabkan munculnya pekerjaan tambahan yang memerlukan waktu tak sedikit seperti seperti fairing, cutting, attaching, fitting, gap fitting. Oleh karena itu, penelitian ini bertujuan untuk mengetahui pengaruh heat input seperti kuat arus dengan kecepatan pengelasan terhadap distorsi sudut yang muncul setelah pengelasan akibat adanya tegangan sisa. Selain dari munculnya distorsi sudut, pada bagian HAZ Heat Affected zone terdapat perbedaan kekuatan yang mengakibatkan rentannya patahan terjadi disana, dengan menggunakan kekerasan, dan rumus empiris didapatkan HAZ las yang mewakili kekuatan sambungan. Pada penelitian ini dapat diambil kesimpulan bahwa kuat arus memiliki pengaruh terhadap distorsi transversal yang hampir sama dengan kecepatan pengelasan dan makin tinggi heat input yang diberikan maka makin besar residual atau distorsi yang dihasilkan.dan pengaruh kuat arus lebih tinggi terhadap distorsi longitudinal dibanding kecepatan pengelasan. Proses pengelasan mempengaruhi kekuatan sambungan.

Welding in the ship industry in Indonesia tends to still use the SMAW welding method, by using GMAW welding method that has a high deposition rate and high efficiency, welding process can be done more quickly. With the increasing speed of welding and electricity current, it is prone to possible distortion in welding. One of the causes of distortion is the uneven heat input of the welding material, resulting in a temperature difference between the weld area and the welded area and causing the tension in the area to cool and strain on the welded area. Thus, proper heat input is required so that it does not occur, angular distortion leads to the emergence of additional jobs that require less time such as fairing, cutting, attaching, fitting, gap fitting. Therefore, this study aims to determine the effect of heat input such as the current strength with welding speed to the angular distortion that emerges after welding due to residual stresses. Apart from the emergence of angular distortion, in the Heat Affected zone HAZ section there is a difference in strength that causes the fracture susceptibility to occur there, using hardness, and empirical formula obtained HAZ welding representing the strength of the connection. In this study it can be concluded that the current strength has an effect on the transversal distortion which is almost equal to the welding speed and the higher the heat input given the greater the residual or distortion generated. And the effect of higher current strength on longitudinal distortion than welding speed The welding process affect the strength of the connection."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Astriansyah
"Kereta Rel Listrik (KRL) disuplai tegangan 1500 V DC oleh gardu traksi yang didalamnya terdapat komponen penyearah. Penyearah ini memproduksi harmonisa yang menyuntikkan arus menuju sumber tegangan menengah 20kV PLN dan dapat menyebabkan rusaknya peralatan listrik. Skripsi ini bertujuan untuk merancang filter untuk mereduksi arus harmonisa distasiun Bogor. Skripsi ini memiliki batasan masalah sebagai berikut, pertama sumber harmonisa yang digunakan adalah penyearah 1500 V DC dan beban non-linier lainya pada gardu traksi Stasiun Bogor. Kedua alat ukur yang digunakan adalah HIOKI 3169 Power Analyzer, dan ketiga jika distorsi harmonisa melebihi standar, maka dilakukan perancangan filter pasif dan akan disimulasikan dan diuji kinerjanya dengan menggunakan program ETAP Power Station 12.6.0.
Hasil pengukuran distorsi harmonisa pada kubikel 20kV/1.2kV gardu traksi dengan PQA menunjukkan THD maksimum tegangan sebesar 3,43 % dan THD arus maksimum sebesar 94,98% THD maksimum tegangan masih standar IEEE (<5%) sedangkan THD maksimum arus berada dinilai yang melebihi standar IEEE (<20%). Untuk mengurangi efek distorsi harmonisa arus, dirancang filter pasif untuk memfilter harmonisa orde ke-5,ke-7, dan ke-11. Hasil simulasi dengan ETAP 12.6.0 didapatkan hasil rancangan filter pasif optimum dapat mengurangi THD arus hingga rata-rata 5,5 %.

Electric train is supplied with 1500 VDC by traction substation which have components of the rectifier. This rectifier produces harmonics that inject harmonics current toward source 20kV PLN and cause the damage of electric utility. This paper have a conclusion to design passive filter for reduce harmonic current at Bogor station. This observation using experimental method with sequence, first literature study, second harmonic distortion measuring and analysis at traction substation in Bogor and third design passive filter will simulation with ETAP powes station 12.6.0 program.
Measurement results of harmonic distortion at 20kV/1.2kV cubicles in traction substation with PQA shows that the maximum value of THD-v is 3,43% and the maximum value of THD-i is 94,98%. THD-v is below IEEE standard (< 5 %) and THD-i is over IEEE standard (<20 %). In order to reduce the effects of harmonics currents, passive filter is designed to filter harmonics for 5th, 7th and 11th order. ETAP 12.6.0 simulation result obtains the optimum design of passive filter that can reduce THD-i to 5,5% average.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S63063
UI - Skripsi Membership  Universitas Indonesia Library
cover
Eka Nurhidayat
"Gangguan harmonisa ( Arus atau Tegangan )merupakan masalah dalam kualitas distribusi tenaga listrik, yang ditimbulkan oleh beban non linier pada sistem tenaga listrik. Masalah harmonisa ini sangat merugikan karena dapat menimbulkan permasalahan kualitas distrbusi listrik yang digunakan, dimana bentuk gelombang suplai akan menjadi terdistorsi sehingga bisa menimbulkan penurunan kinerja dan bahkan akan mengalami kerusakan pada peralatan listrik. Transformator arus merupakan salah piranti listrik yang berfungsi untuk mentransformasikan arus yang besar pada sisi primer menjadi arus yang kecil di sisi sekunder untuk pengukuran dan proteksi. Akurasi (tingkat ketelitian) adalah kemampuan dari alat ukur untuk memberikan nilai tertentu terhadap harga sebenarnya dari objek yang diukur. Dengan mengetahui tingkat akurasi dari suatu instrumen, maka faktor error yang akan terjadi dapat diketahui.
Penelitian ini bertujuan untuk mengetahui pengaruh temperatur lingkungan terhadap ketelitian pengukuran oleh transformator arus dengan beban harmonisa. Dalam penelitian ini, dilakukan pengujian terhadap Transformator Arus dengan beban harmonisa berupa lampu hemat energi. Berdasarkan hasil penelitian menunjukkan bahwa pengaruh temperatur lingkungan kerja transformator arus cukup berpengaruh pada akurasi pengukuran arus. Semakin tinggi temperatur kerja, error pengukuran semakin tinggi yang menyebabkan pembacaan pada alat ukur semakin kecil atau turun dari pembacaan normal.

Harmonic distortions ( Current or Voltage ) are some kind trouble of power quality distribution, it's caused by non-Linear loads. Harmonic could caused bad impact for power distribution systems that used it, where the quality of the supply waveform will be distorted so that it can cause performance degradation and even to experience damage to electrical equipment. Current transformer is one of the electrical equipment that serves to transform a large current on the primary side of a small current in the secondary for measurement and protection. Accuracy (precision) is the ability of a measurement to give a specific value to the actual value of the object to be measured. By knowing the accuracy of an instrument, then the error factor that will occur can be known.
This research aimed to investigate the influence temperature of accuration measurement performance from current transformer with harmonic loads such as energy saving lamps. The results showed that temperature work, is influence to accuration measurement current transformer with non-liniear loads. High temperature, influence caused high error meassurement. It means flow readings on the instruments measurement become smaller than normal.
"
Depok: Fakultas Teknik Universitas Indonesia, 2010
S51288
UI - Skripsi Open  Universitas Indonesia Library
cover
Muhammad Noor Addin
"Pada era modern ini, kebutuhan akan energi listrik merupakan sesuatu yang sudah tidak bisa tergantikan, dimana hal ini tidak menutup kemungkinan akan terjadi banyak permasalahan baru yang akan muncul, diantaranya adalah terus meningkatnya peristiwa kebakaran yang terjadi pada instalasi tegangan rendah akibat gangguan listrik. Kebakaran ini disebabkan karena adanya hubung singkat yang menyebabkan munculnya busur api listrik. Busur api listrik muncul ketika terjadi electrical breakdown pada udara disekitar konduktor, yang menyebabkan pelepasan energi panas dan cahaya yang dihasilkan oleh listrik yang menjalar melalui udara. Sehingga dilakukan sebuah penelitian yang membahas mengenai karakteristik busur api listrik pada tegangan rendah AC. Penelitian ini dilakukan dengan sebuah simulasi artificial short circuit atau hubung singkat tiruan. Pengujian dilakukan dengan menggunakan parameter impedansi saluran berupa variasi jumlah serabut dan luas penampang konduktor yang berbeda untuk melihat pengaruhnya terhadap karakteristik arus dan tegangan yang diukur menggunakan perangkat pengukuran PicoScope. Dari hasil pengujian diketahui bahwa bentuk gelombang (waveform) busur api memiliki nilai arus yang lebih tinggi dari arus sistem yang bekerja normal dan nilai tegangan yang lebih rendah dari tegangan sistem yang bekerja normal, namun memiliki durasi yang singkat. Nilai dari impedansi saluran berpengaruh pada karakteristik arus dan tegangan dari busur api listrik. Semakin besar impedansi salurannya maka semakin kecil nilai arus busur api yang dihasilkan. Hasil pengujian menunjukkan nilai arus terbesar didapatkan saat menggunakan luas penampang kabel 2,5 mm2 dengan variasi 24 serabut dimana nilai peak nya sebesar 216,080 A dan nilai RMS arusnya sebesar 93,178 A.

In this modern era, the need for electrical energy is something that can not be replaced, where this does not rule out the possibility of many new problems that will arise, including the continuing increase in fire events that occur in low voltage installations due to electrical disturbances. This fire was caused by a short circuit which caused the appearance of an electric arc. An electric arc arises when an electrical breakdown occurs in the air around a conductor, which causes the release of heat and light energy generated by electricity that travels through the air. So a study was conducted that discussed the characteristics of electric arcs at low AC voltages. This research was conducted with an artificial short circuit simulation or artificial short circuit. Tests carried out using channel impedance parameters in the form of variations in the number of fibers and different cross-sectional area of ​​the conductor to see the effect on the characteristics of current and voltage measured using a PicoScope measurement device. From the test results it is known that the arc waveform has a higher current value than the normal working system current and the voltage value is lower than the normal working system voltage, but has a short duration. The value of the channel impedance affects the current and voltage characteristics of the electric arc. The greater the channel impedance, the smaller the arc current value generated. The test results show the largest current value is obtained when using a cross-sectional area of ​​2.5 mm² cable with a variation of 24 filaments where the peak value is 216,080 A and the current RMS value is 93,178 A."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library