Ditemukan 114504 dokumen yang sesuai dengan query
Wawan Rochadianto
Depok: Fakultas Teknik Universitas Indonesia, 1998
S39543
UI - Skripsi Membership Universitas Indonesia Library
Agus Supriyanto
Depok: Fakultas Teknik Universitas Indonesia, 1994
S38585
UI - Skripsi Membership Universitas Indonesia Library
Halsall, Fred
Jakarta: Elex Media Komputindo, 1992
004.16 HAL d
Buku Teks SO Universitas Indonesia Library
Halsall, Fred
Jakarta: Elex Media Komputindo, 1992
004.16 HAL d
Buku Teks SO Universitas Indonesia Library
Malau, Dielita Anggitria
"Skripsi ini membahas tentang analisisunder voltage load sheddingpada PT PLN (Persero) APB DKI Jakarta & Banten. Pelepasan beban dilakukan dengan tujuan menaikkan tegangan sistem sampai batas toleransi nilai yang diizinkan yaitu +5 % dan -10 % (Aturan Jaringan, 2007) dari nilai tegangan nominalnya yaitu 150 kV. Simulasi pelepasan beban dilakukan pada bus yang memiliki nilai sensitivitas (dv/dQ Sensitivity) tertinggi dan pada beban yang memiliki nilai daya reaktif tertinggi dengan berbantuan perangkat lunak DIgSILENT PowerFactory. Dengan melakukan pelepasan beban diharapkan tegangan dapat naik secara signifikan. Setelah melakukan simulasi maka di dapat, jumlah beban yang dilepas pada pelepasan beban yang dilakukan berdasarkan nilai sensitivitas bus tertinggilebih sedikit dibandingkan dengan pada pelepasan beban yang dilakukan berdasarkan nilai daya reaktif tertinggi.Hal ini dapat dilihat pada salah satu hasil simulasi pada studi kasus di subsistem Balaraja dimana jumlah beban yang dilepas berdasarkan nilai sensitivitas bus sebesar 22.12 % sedangkanjumlah beban yang dilepa berdasarkan nilai daya reaktif sebesar 37.77 %.
This focus of study is aboutunder voltage load shedding analysis in PT PLN (Persero) APB DKI Jakarta & Banten. The load shedding aims to increase the voltage system until tolerance limit of the allowed value is equal +5 % dan +10 % (due ?Aturan Jaringan, 2007?) of nominal voltage which 150 kV. It based on bus that has the highest value of sensitivity (dv/dQ sensitivity) and onload that has the highest value of reactive power use DIgSILENT Power Factory software. By doing the load shedding be expected that the voltage can increase significantly. After doing the simulation, then we can see that the amount of active power is removed for the load shedding based on the highest value of bus sensitivity is lower than the load shedding based on the highest value of reactive power. It can be seen in one of thesimulation of case study in Balaraja subsystem which the amount of active power that have been shedding based on bus that has the highest value of sensitivity is about 22.12 % and the amount of active power that have been shedding based onload that has the highest value of reactive power is about 37.77 %."
Depok: Fakultas Teknik Universitas Indonesia, 2014
S57240
UI - Skripsi Membership Universitas Indonesia Library
Samsudiat
"Operasi sistem tenaga listrik bertegangan tinggi menuntut kestabilan parameter-parameter kelistrikan, seperti parameter tegangan, agar kinerja dari peralatan-peralatan listrik yang digunakan oleh konsumen menjadi optimal. Tetapi, karakteristik beban dan saluran transmisi dapat mengakibatkan penyerapan tambahan daya reaktif pada sistem yang menyebabkan munculnya susut tegangan yang melebihi batas operasi yang diizinkan. Salah satu metode untuk memperbaiki tegangan dengan memanfaatkan peralatan listrik yang tersedia adalah metode perubahan tap transformator tap staggering . Tap staggering adalah mengoperasikan transformator daya secara paralel dengan membedakan posisi tap yang relatif kecil. Perbedaan tap ini akan menimbulkan arus sirkulasi yang bersifat induktif dan digunakan sebagai kompensator daya reaktif untuk sistem. Sebuah jaringan distribusi dengan dua buah transformator yang beroperasi paralel dari Sistem Jawa-Bali dilakukan simulasi tap staggering dengan menggunakan analisis aliran daya pada ETAP 12.6.0. Simulasi tap staggering dilakukan dari subsistem yang memikul beban paling tinggi pada sistem. Dari hasil analisis aliran daya, diketahui bahwa tap staggering pada subsistem IBT 150/70 kV dapat melakukan perbaikan tegangan dari rata-rata tegangan 88,85 diperbaiki menjadi 93,5 . Pada subsistem trafo distribusi 70/20 kV yang memiliki perbaikan tegangan antara 88,12 sampai 92,40 meningkat menjadi 92,75 sampai 97,23 saat subsistem IBT 150/70 kV dilakukan tap staggering. Pada subsistem IBT 500/150 kV yang dilakukan tap staggering dapat meningkatkan perbaikan tegangan pada subsistem-subsistem yang dilayaninya dimana perbaikan tegangan terbaik diperoleh saat posisi tap IBT1 -8,75 , IBT3 -10 , IBT5 -10 , T1 -10 dan T3 -10 dengan rentang nilai tegangan masing-masing busnya adalah antara 97 sampai 102.
Operating high voltage power systems requires stability of electrical parameters, such as voltage parameters, so the performance of electrical utilities used by consumers can be optimal. However, the characteristics of load and transmission line can absorb additional reactive power in the system that causes drop voltage that exceeds the limit of permitted operations. One method to improve the voltage by utilizing the existing electrical equipment is tap staggering method. Tap staggering is operating power transformer in parallel with small different tap positions. Differences tap positions can provide inductive currents circulation and it rsquo s used as reactive power compensator for the system. A distribution network with two power transformer in parallel of Jawa Bali system is simulated tap staggering by using the power flow analysis on ETAP 12.6.0. Tap staggering is simulated from subsystem that connects a highest load in the system. From power flow analysis, tap staggering at 150 70 kV IBT subsystem can improve voltage from an average of 88.85 to 93.5 . In the 70 20 kV distribution transformer subsystems that have improvements voltage between 88.12 to 92.40 can increase improvements voltage becomes between 92.75 to 97.23 when subsystem IBT 150 70 kV is taken by tap staggering. At subsystem IBT 500 150 kV, tap staggering can increase the voltage on the improvement subsystems where the best voltage improvement is obtained when the tap positions IBT1 8.75 , IBT3 10 , IBT5 10 , T1 10 and T3 10 with a range of values of each bus voltage is between 97 to 102."
Depok: Fakultas Teknik Universitas Indonesia, 2016
S66898
UI - Skripsi Membership Universitas Indonesia Library
KLET 11(1-2) 2012
Artikel Jurnal Universitas Indonesia Library
Rama Aryarakhito Wongso
"The reactive power plays an important role in almost every power transmission industry. Assessing the reactive power, its component influences the voltage stability, voltage reliability, and transient stability in the grid is important to maintain the power transmission grid. Those components are also used to improve system efficiency, maintain the system ability to stand in the standard values to avoid unwanted tragedies, such as sudden voltage drop caused by sudden decrease of reactive power or when the transmission flow does not go in line caused by overloaded current increase. Those unwanted phenomena are potentially harmful to the system.
In order to adjust the reactive power level into the needed and its components that are influenced by the reactive power values, the reactive power compensation devices are strongly needed. There are already some reactive power compensation devices in the recent industry. The performance factor, reliability, and the availability are considered in this bachelor thesis. Therefore, comparison and analysis will be conducted on the reactive power compensation devices and methodologies to determine the requirement and the placing of reactive power will be conducted. The need to control the reactive power is done by some devices, and the system is made so in such way in order to maintain its qualities, these qualities are going to be discussed mainly in this bachelor thesis.
Daya reaktif memiliki peran penting di hampir setiap industri transmisi daya. Dengan daya reaktif, nilai dari komponen tersebut dapat mempengaruhi kestabilan tegangan, keandalan dan kestabilan sementara untuk menjaga jaringan transmisi listrik. Komponen-komponen tersebut juga digunakan untuk meningkatkan efisiensi sistem, menjaga kemampuan sistem untuk tetap pada nilai standar untuk menghindari tragedi yang tidak diinginkan, seperti penurunan tegangan secara tibatiba yang disebabkan oleh penurunan daya reaktif secara spontan atau ketika aliran transmisi tidak berjalan karena kelebihan beban. Fenomena yang tidak diinginkan tersebut berpotensi membahayakan sistem.Untuk menyesuaikan level daya reaktif dan komponennya menjadi sesuai, perangkat kompensasi daya reaktif sangat diperlukan. Sudah ada beberapa perangkat kompensasi daya reaktif yang tersedia di pasar. Faktor kinerja, kehandalan, dan ketersediaan akan dibahas di dalam skripsi ini. Oleh karena itu, perbandingan dan analisis perangkat kompensasi daya reaktif dan metodologi perlu dilakukan untuk menentukan kebutuhan dan penempatan daya reaktif. Kebutuhan untuk mengontrol daya reaktif dilakukan oleh beberapa perangkat dan membuat sistem sedemikian rupa untuk mempertahankan kualitas daya reaktif yang diinginkan. Pembahasan kualitas tersebut akan dibahas di dalam skripsi ini."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership Universitas Indonesia Library
Elian Richard
"Perkembangan industri di Indonesia yang pesat mendorong peningkatan permintaan pasokan listrik di berbagai sektor demi tercapainya implementasi teknologi industri 4.0 dan terwujudnya inisiatif Making Indonesia 4.0 oleh Kementrian Perindustrian Republik Indonesia. Maka dari itu, sangat penting bagi sebuah industri untuk memiliki sistem tenaga listrik yang baik untuk bisa mendapatkan harga yang terjangkau dengan melakukan penghematan pemakaian daya. Salah satu cara yang dapat dilakukan pada sistem tenaga listrik yang beroperasi dengan baik adalah dengan meningkatkan faktor daya operasionalnya. Agar tercapainya peningkatan faktor daya, perlu ditentukan jenis kompensator faktor daya untuk menentukan besaran daya reaktif kompensasi yang sesuai. Besaran daya reaktif kompensasi yang dibutuhkan perlu dilakukannya optimasi, dapat digunakan algoritma pembobotan normalisasi minimax agar komputasi dapat relatif lebih mudah dan lebih cepat. Pada studi kasus di PT. ON, algoritma pembobotan normalisasi minimax dapat menentukan besaran kapasitor optimum (21 kVAR dengan 7 step) sehingga dapat dihasilkannya penghematan daya reaktif sebesar 1.083,73 kVAR dengan rata-rata sebesar 11.29 kVAR (62.30%), menaikkan rata-rata faktor daya dari 0.8 menjadi 0.96 (20%), menurunkan rata rata penggunaan arus menjadi 20.67 Ampere (78.34%), menurunkan rata-rata daya semu menjadi 13.00 VA (74.09%), dan menurunkan rata-rata rugi-rugi daya yang dihasilkan sebesar 31.48%.
The fast improvement of the industrial sector in Indonesia has pushed the escalation of electrical supply demand in every sector to achieve the implementation of industrial technology 4.0 and the realization of Making Indonesia 4.0 by the Ministry of Industry Republic of Indonesia. Therefore, the industry needs to have a good power electrical system to decrease electrical expenses, and one of the ways is to limit the use of power electricity. One of the things that can be done to have a good operation of the power electrical system is to achieve the enhancement of the power factor. To achieve it, the type of power factor compensator has to be determined, then the suitable value of compensation reactive power can be determined. The amount of reactive power compensation needed needs to be optimized, in which the minimax normalization weighting algorithm can be used so that computation can be relatively easier and faster. In the case study of PT. ON building, the minimax normalization weighting algorithm can determine the optimum capacitor size (21 kVAR with 7 steps) so that a reactive power saving of 1,607.45 kVAR and average of 11.29 kVAR (62.30%) can be generated, increasing the average power factor from 0.8 to 0.96 (20%), reducing the average current usage to 20.67 Amperes (78.34%), lowering the average apparent power to 13.00 VA (74.09%), reducing the resulting average power losses by 31.48%."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership Universitas Indonesia Library
Fakultas Teknik Universitas Indonesia, 1998
S39545
UI - Skripsi Membership Universitas Indonesia Library