cover
Fakultas Teknik Universitas Indonesia, 1999
S39531
UI - Skripsi Membership  Universitas Indonesia Library
cover
Siregar, Rinaldi
"SUTET 500 kV Ungaran - Bandung Selatan terbentang sepanjang 342.8 km menghubungkan area l&2 (Distribusi Jakarta Raya & Tangerang dan Distribusi Jawa Barat ) dengan area 3&.4 (Distribusi Jawa Tengah dan Distribusi Jawa Timur & Bali). Pada tanggal 3 Mei 1998 sejak pukul 12.03, proses sinkronisasi sulit dilakukan karena tidak tercapainya kondisi sinkron di kedua sisi.
Data pada alat Perekam Data Gangguan (DPR = Data Fault Recorder) di Bandung Selatan-Ungaran menunjukkan adanya distorsi (osilasi) gelombang tegangan. Osilasi (distorsi) gelombang tegangan berupa tegangan lebih menyebabkan Gardu Induk Tegangan Ekstra Tinggi (GITET) Bandung Selatan tidak sinkron dengan GITET Ungaran. Osilasi tegangan diatas adalah suatu fenomena resonansi inti besi (ferroresonance) Karena di sisi 500 kv tidak ada gangguan, maka osilasi ini diduga disebabkan adanya flash over di sisi selcunder Trafo Tegangan Kapasitor
Untuk membuktikan terjadinya resonansi inti besi di sisi sekunder Trafo Tegangan Kapasitor dilakukan simulasi dengan menggunakan perangkat lunak Electromagueiic Transien! Program ,HffTP). Simulasi dilakukan dengan melakukan penutupan saklar (switching) di GITET Bandung Selatan pada keadaan GITET Ungaran terbuka , kemudian dilihat kurva tegangan di sisi primer dan sekunder CVT di Ungaran_ Dari hasil simulasi diketahui terjadi Resonansi Inti Besi di sisi sekunder CVT yang ditandai dengan terdistorsinya gelombang tegangan sehingga salah satu syarat sinkronisasi yaitu tegangan di kedua GITET harus sama tidak terpenuhi. Simulasi kedua dilakukan pemasangan FSC (Ferroresonance Suppression Circuit) dalam selang waktu tertentu, kemudian dilepas. Simulasi ini dilakukan unluk memilih lama waktu pemasangan FSC yang tepat, sehingga saat FSC dilepas tidak terjadi lagi distorsi gelombang tegangan. Simulasi ketiga dilakukan dengan ntenggunakan perangkat Iunak MATLAB versi 5.0 yang memiliki fasilitas FFT (Fast Fouder Transform) untuk melihat frekuensi yang dominan pada gelombang tegangan sekunder CVT."
Depok: Fakultas Teknik Universitas Indonesia, 1998
S39513
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
Pohan, M. Halim K.
Depok: Fakultas Teknik Universitas Indonesia, 1999
S39534
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dhimas Permana
"ABSTRACT
Proyeksi kebutuhan tenaga listrik di wilayah Balaraja cenderung mengalami kenaikan peningkatan beban, sehingga untuk memenuhi kebutuhan tersebut diperlukan pengembangan sarana kelistrikan diantaranya pengembangan sistem transmisi. Pengembangan tersebut mengharuskan sistem proteksi pada sistem transmisi untuk disesuaikan dalam hal desain dan setting peralatannya. Salah satu peralatan penting dalam proteksi sistem transmisi adalah relai jarak yang dapat mendeteksi adanya gangguan hubung singkat. Pada skripsi ini, pengembangan sistem transmisi di Balaraja terjadi dengan menambahkan Gardu Induk Spinmill sehingga akan membuat konfigurasi penyetelan relai jarak yang berada didekat Gardu Induk Spinmill akan berubah. Selain itu, secara keseluruhan bentuk konfigurasi saluran udara tegangan tinggi 150 KV di Balaraja adalah saluran ganda ke ganda yang akan berpengaruh terhadap kinerja relai jarak akibat pengaruh infeed dan mutual impedansi urutan nol sehingga penyetelan relai jarak akibat adanya penambahan Gardu Induk Spinmill perlu memperhatikan faktor yang dapat mempengaruhi kinerja relai jarak tersebut. Berdasarkan simulasi setting rekonfigurasi yang telah mempertimbangkan faktor-faktor yang dapat mempengaruhi kinerja relai jarak maka dapat diambil kesimpulan bahwa rekonfigurasi setting relai jarak di Balaraja sudah benar dikarenakan tidak ada zona pengaman yang tumpang tindih dan zona pengaman relai jarak memiliki jangkauan setting yang dapat melindungi saluran transmisi sesuai dengan kaidah penyetelan

ABSTRACT
The projection of electricity demand in Balaraja region tends to the load increase, so to fulfill the requirement, it is necessary to develop electricity facilities such as the developing of transmission system. The development requires protection systems on the transmission system to be customized in terms of design and equipment settings. One of the important device in the protection of transmission system is a distance relay that can detect a short circuit fault. In this thesis, the development of transmission system in Balaraja occurs by adding the Spinmill Substation so that it will make the configuration of the distance relay adjustment near the Spinmill Substation will change. In addition, the overall configuration of the 150 KV high voltage overhead transmission lines in Balaraja is double to double channel which will affect the relay distance performance due to the infeed and mutual impedance of zero sequence so that the distance relay adjustment due to the addition of the Spinmill Substation should take into consideration factors affect the performance of the distance relay. Based on the simulation of reconfiguration settings that have considered factors that may affect the performance of the distance relay it can be concluded that the reconfiguration of the relay distance settings in Balaraja is correct because there is no overlapping security zone and the relay distance safety zone has a range of settings that can protect the transmission line according to the setting rules. "
2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhamad Abdul Aziz
"Sistem transmisi Voltage Source Converter-High Voltage Direct Current (VSC-HVDC) telah menjadi pilihan utama dalam transmisi daya jarak jauh karena keunggulannya dalam hal fleksibilitas dan stabilitas. Namun, tantangan utama dalam pengoperasian sistem VSC-HVDC adalah menjaga stabilitas dan performa optimal, terutama dalam kondisi transien dan saat terjadi gangguan. Penelitian ini bertujuan untuk mengoptimalkan kinerja sistem transmisi VSC-HVDC dengan menggunakan kontrol roportional-Integral Adaptive Neuro-Fuzzy Inference System (PI-ANFIS) dan membandingkan performanya dengan kontrol PI konvensional. Penelitian ini menggunakan pemodelan sistem transmisi VSC-HVDC dengan kontrol PI sebagai dasar. Data relasi input-output dari model tersebut kemudian digunakan untuk melatih model ANFIS. Setelah itu, model VSC-HVDC dengan kontrol PI-ANFIS dikembangkan dan dianalisis. Kinerja sistem dengan kontrol PI-ANFIS dievaluasi dalam kondisi transien dan saat terjadi gangguan, baik gangguan permanen maupun sementara.  Hasil penelitian menunjukkan bahwa kontrol PI-ANFIS mampu meningkatkan performa sistem transmisi VSC-HVDC secara signifikan dibandingkan dengan kontrol PI konvensional. Dalam kondisi transien, PI-ANFIS mampu mengurangi overshoot dan mempercepat settling time pada kendali daya aktif, daya reaktif, dan tegangan DC. Saat terjadi gangguan permanen, PI-ANFIS menunjukkan kemampuan yang lebih baik dalam menjaga kestabilan dan mempercepat waktu pemulihan sistem. Pada kondisi gangguan sementara, PI-ANFIS mampu mencapai kestabilan lebih cepat dan menjaga stabilitas dalam batas yang diinginkan. Keunggulan kontrol PI-ANFIS didasari oleh kemampuan adaptasi dan pembelajaran dari algoritma ANFIS, yang memberikan fleksibilitas tambahan dalam menghadapi kondisi dinamis dan gangguan tak terduga. Implementasi kontrol PI-ANFIS pada sistem transmisi VSC-HVDC tidak hanya meningkatkan kinerja sistem dalam jangka pendek, tetapi juga dapat memberikan manfaat ekonomi jangka panjang melalui peningkatan keandalan dan pengurangan biaya pemeliharaan sistem. Penelitian ini memberikan kontribusi signifikan dalam pengembangan teknologi kontrol cerdas untuk sistem transmisi daya yang lebih handal, efisien, dan adaptif. Hasil penelitian ini dapat menjadi landasan untuk penelitian lebih lanjut dan adopsi kontrol PI-ANFIS dalam aplikasi praktis pada sistem transmisi VSC-HVDC di masa depan.

Voltage Source Converter-High Voltage Direct Current (VSC-HVDC) transmission systems have become the preferred choice for long-distance power transmission due to their advantages in flexibility and stability. However, the main challenge in operating VSC-HVDC systems is maintaining optimal stability and performance, especially under transient conditions and during disturbances. This research aims to analyze the performance of VSC-HVDC transmission systems using Proportional-Integral Adaptive Neuro-Fuzzy Inference System (PI-ANFIS) control and compare its performance with conventional PI control. This research uses modeling of the VSC-HVDC transmission system with PI control as a basis. The input-output relationship data from the model is then used to train the ANFIS model. Afterward, the VSC-HVDC model with PI-ANFIS control is developed and optimized. The performance of the system with PI-ANFIS control is evaluated under transient conditions and during disturbances, both permanent and temporary. The results show that PI-ANFIS control can significantly improve the performance of the VSC-HVDC transmission system compared to conventional PI control. Under transient conditions, PI-ANFIS is capable of reducing overshoot and accelerating settling time in active power, reactive power, and DC voltage control. During permanent disturbances, PI-ANFIS demonstrates better ability in maintaining stability and accelerating system recovery time. Under temporary disturbance conditions, PI-ANFIS achieves stability faster and maintains stability within desired limits. The superiority of PI-ANFIS control is based on the adaptability and learning capabilities of the ANFIS algorithm, which provides additional flexibility in dealing with dynamic conditions and unexpected disturbances. The implementation of PI-ANFIS control in VSC-HVDC transmission systems not only improves short-term system performance but can also provide long-term economic benefits through increased reliability and reduced system maintenance costs. This research makes a significant contribution to the development of intelligent control technology for more reliable, efficient, and adaptive power transmission systems. The results of this research can serve as a foundation for further research and the adoption of PI-ANFIS control in practical applications of VSC-HVDC transmission systems in the future."
Depok: Fakultas Teknik Universitas Indonesia, 2024
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Ilham Dwi Prasetyo
"Arus dan tegangan pada suatu konduktor listrik bisa menyebabkan terjadinya fenomena munculnya gelombang elektromagnetik. Paparan medan elektromagnetik bisa menyebabkan bahaya terhadap sistem tenaga listrik yang dilaluinya dan juga manusia yang berada disekitar saluran transmisi listrik tersebut. Skripsi ini membahas karakteristik medan listrik di sekitar saluran transmisi dan mencari solusi untuk memastikan paparan medan elektromagnetik aman untuk manusia. Simulasi yang ada pada skripsi ini menggunakan desain transmisi saluran udara tegangan ekstra tinggi 275 kV yang akan digunakan PT. Perusahaan Listrik Negara dan peraturan menteri tentang jarak aman paparan medan listrik untuk manusia. Metode yang digunakan pada skripsi ini adalah perhitungan menggunakan Matlab untuk menghitung muatan konduktor dan menggunakan Microsoft Excel untuk menghitunga data-data yang lain. Dari hasil simulasi, didapatkan bahwa jarak aman minimum horizontal untuk bangunan, pada polusi menengah 19,5 meter, pada polusi tinggi adalah 20 meter, dan pada polusi sangat tinggi adalah 21 meter. Nilai medan listrik yang dekat dengan permukaan bumi Near Ground Level Electric Field pada polusi menengah 4,124 kV/m, pada polusi tinggi 4,471 kV/m, dan pada polusi ekstra tinggi 4,769 kV/m.

Current and voltage in electrical conductor can cause electromagnetic field phenomenon. Electromagnetic field exposure can harm the electrical system that causes it and people who live near the field. This book discusses characteristic of electric field around transmission lines and gives the solution for the problems of electromagnetic radiation to make sure that the field is safe for humans and transmission lines. The simulation given in this book uses the spcification of transmission lines that will be used by PT. Perusahaan Listrik Negara and uses standars given by Power Ministry of Indonesia about the safe distance of electromagnetic exposure. Methods used in this project are calculations using Matlab for conductor charge and Microsoft Excel to calcuate other data. From the simulation, it is concluded that the minimum safe distance for moderate polution level is 19,5 meter, for high polution level is 20 meter, and for very high polution level is 21 meter. Electric field value at near ground level for moderate polution level is 4.124 kV m, for high polution level is 4.471 kV m, and for very high polution level is 4.769 kV m. "
Depok: Fakultas Teknik Universitas Indonesia, 2017
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Tobing, Bonggas L.
Jakarta: Erlangga, 2012
621.3 TOB d
Buku Teks  Universitas Indonesia Library
cover
Adhistira Madhyasta Naradhipa
"Untuk melakukan pengujian terhadap sistem proteksi petir pada skala laboratorium diperlukan pembangkit tegangan tinggi impuls dimana membutuhkan masukan tegangan yang cukup tinggi untuk menghasilkan pelepasan muatan dalam jarak tertentu. Kapasitor pengisi harus dibuat cukup besar agar dapat menahan tegangan masukan yang tinggi sehingga akan memakan biaya dan tempat yang besar. Erwin Otto Marx pada tahun 1923 menemukan rangkaian pembangkit tegangan tinggi impuls banyak tahap atau yang sering disebut sebagai marx generator dimana rangkaian tersebut dapat menghasilkan tegangan yang tinggi dengan masukan tegangan yang rendah. Marx generator yang dibangun terdiri dari 10 tahap dan dibuktikan bahwa dengan masukan tegangan 5kV-7.5kV dapat menghasilkan tegangan pulsa 29.14kV-43.6kV dimana persamaan estimasi tegangan keluaran adalah . Dibuktikan juga bahwa dengan keluaran tegangan tersebut dapat terjadi tegangan tembus di udara sampai dengan 1.5 cm untuk jenis sela udara jarum-pelat.

To conduct a test for lightning protection system on a laboratory scale we need high impulse voltage generator. A high impulse voltage generator need high input voltage, therefore the components of the generator have to be build strong enough to hold the stress from the high input voltage. Erwin Otto Marx found multistage high impulse voltage generator or often called marx generator, the marx generator only need low input voltage to generate high pulse voltage so the components of marx generator didn?t have to be strong enough to hold overall output voltage. The marx generator that i have build is consist of 10 stages and proven that with input voltage 5kV-7.5kV can produce 29.14kV- 43.6kV pulse voltage with the formula of voltage output estimation is . Also it proven with that pulse voltage it produce a voltage breakdown in the air up to 1.5 cm for rod-plate spark gap."
Depok: Fakultas Teknik Universitas Indonesia, 2015
S59544
UI - Skripsi Membership  Universitas Indonesia Library
cover
Lintang Hapsari Wilujeng
"

Sumber tegangan listrik merupakan salah satu kebutuhan primer modern di masa sekarang.Sumber tegangan listrik mutlak dibutuhkan untuk menjamin tetap bekerjanya peralatan tersebut.

Namun masalah yang sering dihadapi seringkali adalah sumber-sumber tegangan memiliki nilai yang jauh dibawah level tegangan kerja yang umumnya digunakan pada sistem jaringan listrik perumahan. Untuk mengatasai permasalah sumber tegangan DC tersebut, salah satu cara yang dapat diambil adalah dengan mengimplementasikan sebuah rangkaian pengubah nilai tegangan DC atau DC-DC Converter.

Pada penelitian ini penulis menawarkan rangkaian DC-DC Converter dari tipe terisolasi, yaitu Push-Pull Converter. Pemilihan Push-Pull Converter dilakukan atas beberapa alasan antara lain keandalan, kualitas daya yang dihasilkan, kemudahan untuk diaplikasikan serta yang paling penting adalah ketahanan dari gangguan yang mungkin terjadi.

Sistem dikendalikan dengan menggunakan Pengendali PI dan IP serta diuji kualitasnya dengan menggunakan Diagram Bode.Hasil dari simulasi serta analisa kestabilan menunjukkan bahwa Rangkaian Push-Pull adalah rangkaian yang tahan terhadap gangguan.


Power supply is one of the modern primary needs in the present. Power supply is absolutely necessary to ensure the continuity cooperation of the equipment. However, a problem that often encountered is voltage sources values are far below the working voltage levels that are generally used in residential electrical grid system. To handling the problems of the DC voltage source, one way that can be taken is to implement a DC voltage converter circuit or DC-DC Converter.

In this research, a series of isolated type DC-DC Converters, namely Push-Pull Converter, is being promoted. The Selection of Push-Pull Converter based on reliability and quality of generated power among others, ease of applicability and the most important is the robustness of the interference that may occur.

The system is controlled using a PI controller and the IP also stability tested using Bode plots. The results of simulation and analysis shows that the stability of the Push-Pull circuit is a circuit that is resistant to interference.

"
Fakultas Teknik Universitas Indonesia, 2014
S56862
UI - Skripsi Membership  Universitas Indonesia Library