Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 144932 dokumen yang sesuai dengan query
cover
Feisul Fadely
"Kebutuhan lemari pendingin sudah menjadi hal yang umum. Hal ini mengakibatkan peningkatan produksi refrigerant yang tidak ramah lingkungan. Salah satu solusinya adalah dengan menggunakan refrigerant hidrokarbon yang ramah lingkungan. Refrigeran yang digunakan adalah R-600a dan HC 134. Pengujian dilakukan pada suhu lingkungan 30 - 36°C. Lalu dilakukan analisa dengan melihat suhu dari kondenser dan evaporator. Suhu evaporator diambil suhu ratarata dari 10°C sampai -4°C. Diharapkan didapat hasil yang lebih baik dari refrigerant hidroflorocarbon. Pengolahan data dibantu dengan software coolpack. Penggunaan fotovoltaik pada lemari pendingin hanya bertujuan agar lemari pendingin dapat digunakan didaerah terpencil.

The need of refrigerator has become an ordinary matter. This cause an increase in the production of refrigerant that not environmental friendly. One of the solution is by using hydrocarbon refrigerant which is environmental friendly. The refrigerant in use are R-600a and HC 134. The test is being done in ambient temperature between 30 - 36°C. Then the analysis is done by seeing the condenser and evaporator temperature. The mean evaporator temperature taken is between 10 and -4°C. Coolpack software is used to help the analysis. And hoping that the result is better than hydroflourocarbon refrigerant. The reason of using photovoltaic is to make refrigerator can be used in remote area."
Depok: Fakultas Teknik Universitas Indonesia, 2007
S37951
UI - Skripsi Membership  Universitas Indonesia Library
cover
Siallagan, Timothy Felix Vickary
"Penggunaan refrigeran khususnya klorofluorokarbon (CFC), Hidrofluorokarbon (HFC), dan Hidroklorofluorokarbon (HCFC) pada kulkas berkontribusi besar dalam pemanasan global, sementara penggunaan Hidrokarbon sudah terbukti menjadi pilihan yang lebih baik. Penelitian ini menunjukkan hasil analisa berbasis eksergi dari siklus refrigerasi pada kulkas rumah tangga menggunakan refrigeran hidrokarbon (R600a) sesuai dengan standar SNI ISO15502:2008. Dengan menerapkan metode Taguchi pada desain eksperimen dan melalui penetapan parameter eksergi diantaranya entalpi, entropi, laju alir massa, coefficient of performance (COP), tipe susunan beban pendingin, sehingga penggunaan optimum dapat diperoleh. Model analisis yang digunakan adalah siklus yang mengikutsertakan irreversibilitas dari perpindahan kalor melalui perbedaan temperature terbatas, kebocoran kalor, dan disipasi internal. Pendekatan dilakukan dengan mengkombinasikan persamaan matematis atau simulasi siklus dalam Engineering Equation Solver (EES) dengan eksperimentasi secara langsung pada kulkas yang berada didalam ruang uji lingkungan dimana keadaan lingkungan sudah dikondisikan sesuai ketetapan yang berlaku.

The use of refrigerant specifically Chlorofluorocarbons (CFC), Hydrofluorocarbons (HFC), and hydrochlorofluorocarbons (HCFC) in refrigerators greatly contribute to global warming, while the choice of hydrocarbon refrigerant proves to be a better option. This research shows the results of an exergy-based analysis of the irreversible refrigeration cycle on household refrigerators using hydrocarbon refrigerant (R600a) in accordance with SNI ISO15502: 2008 standard. By applying Taguchi Method for experimental design and through parameters of determinants of exergy such as enthalpy, entropy, mass flow rate, the coefficient of performance (COP), load array types, therefore the optimum use of refrigerant can be obtained. The model analyses used is cycle that include irreversibility of heat transfer across finite temperature differences, heat leakage, and internal dissipation. The approach is done by combining mathematical modelling or simulation cycle in engineering equation solver (EES) software with experiment directly on refrigerator inside environmental chamber where environment has been conditioned according to the prevailing provisions."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Safri Maruta Hadi
"Lemari pendingin membutuhkan energi listrik agar dapat digunakan. Namun di daerah terpencil yang belum mendapatkan fasilitas energi listrik, sehingga lemari pendingin tidak dapat dinikmati oleh masyarakat. Maka dari itu diperlukan sumber energi alternatif lain sebagai penggantinya, salah satu contohnya adalah energi listrik yang berasal dari modul fotovoltaik. Energi listrik yang berasal dari modul fotovoltaik merupakan tegangan DC 12 Volt sehingga perlu diubah menjadi tegangan AC 220 Volt agar kompresor dapat bekerja. Maka dari itu diperlukan inverter untuk merubah tegangan DC menjadi tegangan AC.

Refrigerator require electricity power in order to can be used, but in remote area which not yet got facility of electricity power. So that refrigerator cannot be enjoyed by people. Hence from that needed by power source of other alternative power, one of the example electrics power coming from photovoltaic module. Electrics power coming from photovoltaic module represent 12 Volt DC voltage so that require to be turned into 220 Volt AC voltage in order to compressor earn to work. Hence from that needed inverter for convert DC voltage become AC voltage."
Depok: Fakultas Teknik Universitas Indonesia, 2007
S37948
UI - Skripsi Membership  Universitas Indonesia Library
cover
"Two things that become world concern are energy crisis and environmental problem, Refrigerator is
one of the causes of the problems either direct or indirect. Refrigerator uses electricity source that comes
front fossil fuel as indirect cause of energy crisis and environmental' problem which contributes to ozone
depletion and global warming by using the refrigerant. Therefore we need a solution that can answer
the problems. The solution is photovoltaic refrigerator .system with hydrocarbon refrigerant. This system
uses photovoltaic module connected to the inverter. The function of inverter is to convert i2 Volt DC
electric voltage from photovoltaic module into 220 Volt A C electric voltage, The refrigerant are
hydrocarbon R-600a and HC-134 which charged at 20 bar pressure. The experiment shows that the
inverter which suitable for refrigerator is pure sine wave inverter type and the alternative refrigerant is
R-600a. Refrigerator with photovoltaic module can be used until 21.5 hours without charging.
"
Jurnal Teknologi, 21 (4) Desember 2007 : 265-273, 2007
JUTE-21-4-Des2007-265
Artikel Jurnal  Universitas Indonesia Library
cover
Eko Pratama Astin
"ABSTRAK
Pada tahunnya 1999 Indonesia sebagai voluntary program energi labeling
khususnya lemari pendingin rumah tangga yang bertujuan untuk memberikan
label energi sebagai tanda produk tersebut hemat energi. Program ini sejalan
dengan kesepakatan Indonesia untuk mengantisipasi global warming di dalam
Protokol Kyoto1997. Penelitian yang dilakukan oleh penulis yaitu memperkirakan
energi konsumsi lemari pendingin berdasarkan SNI ISO 15502-2009 dimana
kondisi temperature lingkungan dikondisikan sebesar 32, 30 dan 28 °C. Dari
pengujian tersebut dihasilkan bahwa dengan meningkatnya temperature
lingkungan maka energi konsumsi yang dibutuhkan juga meningkat. Dengan
bertambahnya 1 °C temperature lingkungan maka energi konsumsi yang
dibutuhkan akan meningkat sebesar 65 Wh/24 jam.

ABSTRACT
Indonesia as voluntary program on energy efficiency and labeling in 1999, one of
the appliance household in energy efficiency and labeling is refrigerator as
efficiency product. This program as one of commitment Indonesia government to
reduce impact global warming in Kyoto ptotocol 1997. Research conducted by the
authors estimate the energy consumption of refrigerators based on ISO 15502-
2009 where it’s setting ambient temperature conditions of 32, 30 and 28 ° C. Of
the test result that by increasing the environmental temperature energy
consumption required also increases. With a 1 °C increase in ambient temperature
required the energy consumption will increase by 65 Wh/24 hours."
2013
T36743
UI - Tesis Membership  Universitas Indonesia Library
cover
Fajri Hidayat
"Green Medical Box adalah sebuah tempat untuk pendinginan obat-obatan, vaksin, darah dan organ menggunakan refrigeran yang ramah lingkungan yaitu R600a. Sumber energi untuk green medical box ini bisa menggunakan power supply 220 VAC/12 VDC, batere atau solar panel. Pada tugas akhir ini pengujian menggunakan sumber energi dari power supply 220 V AC / 12 V DC dan batere 12 V DC. Green medical box ini terdiri dari 2 kabin yaitu kabin cooler dan kabin freezer. Untuk kabin cooler set point temperaturnya pada +5 ºC dan kabin freezer -15 ºC. Temperatur kabin diatur oleh dua solenoid yang masing-masing dipasang di liquid line sebelum masuk pipa kapiler, dimana mekanisme buka tutupnya diatur oleh digital thermostat. Pada keluaran cooler dipasang EPR yang berfungsi untuk menjaga tekanan evaporasi pada cooler dan pada keluaran freezer dipasang check valve yang berfungsi untuk mencegah agar tidak ada aliran balik menuju freezer yang tekanannya sangat rendah.
Pengujian Green Medical Box ini dilakukan dengan 4 variasi percobaan yaitu pertama alat dioperasikan menggunakan sumber listrik PLN dengan putaran 3500 rpm pada kompresor, kedua alat dioperasikan menggunakan sumber listrik PLN dengan putaran 2000 rpm pada kompresor. Dua tahap selanjutnya adalah dengan mengganti sumber listrik dengan batere 12 VDC dengan model variasi putaran yang sama. Dari beberapa variasi percobaan ini didapatkan beberapa pola perubahan tekanan, temperatur dan daya yang terjadi pada sistem yang menunjukkan karakteristik sistem. Untuk penelitian selanjutnya penulis menyarankan untuk memasangkan pressure transmitter pada sistem agar dapat mendeteksi perubahan-perubahan yang terjadi pada sistem lebih lanjut. Juga jika temperatur set point yang diinginkan belum tercapai saat cooler dan freezer bekerja bersamaan maka hendaknya memperbesar kapasitas kompresor.

Green Medical Box is a storage for refrigeration of the medicines, vaccines, blood plasma and organ using friendly environment refrigerant such as R600a. The power of the Green medical Box can uses power supply 220 V AC / 12 V DC, battery or solar panel. This final project uses power supply 220 V AC / 12 V DC and 12 VDC Battery. This Green Medical Box consist of 2 cabin (cooler cabin and freezer cabin). The set point temperature cooler cabin is +5 ºC and freezer cabin is -15ºC. Cabin temperature controlled with solenoid each put liquid line before capilary tube. Open close of the selenoid controlled with digital thermostat.At the cooler outlet there is EPR which control the evaporation temperature in cooler, and at the freezer outlet equipped with check valve to make sure that there is no reversed flow to freezer whose have a very low pressure.
Testing of Green Medical Box have four variation: first is running the system using 220 VAC source power with 3500 rpm speed of compressor's motor; second running the system using 220 VAC source power with 2000 rpm speed of compressor's motor. The next two steps is changing the source power with 12 VDC battery with the same variation of compressor's motor speed. From these experiments we got some changing on pressure, temperature and power consumed by the system which show it's characteristic. For the next riset the writer to suggest use pressure transmitter on the system to detect more alteration on this system. And if the system cannot reach set point temperature we have to increase the capacity of the compressor.
"
Depok: Fakultas Teknik Universitas Indonesia, 2009
S50978
UI - Skripsi Open  Universitas Indonesia Library
cover
Deny Eva Tri Pambudi
"Ilmu Pengobatan dan biomedis dalam perkembangan penelitianya memerlukan cold storage yang mampu mencapai temperatur -80°C. Untuk mencapai temperatur rendah tersebut digunakan sistem refrigerasi autocascade. Selama ini sistem refrigerasi autocascade menggunakan refrigeran yang mengandung zat perusak ozon atau penyebab pemanasan global. Karena itu, diperlukan alternatif refrigeran alamiah yang ramah lingkungan diantaranya yaitu hidrokarbon. Sistem refrigerasi Autocascade memiliki karakteristik yang tergantung pada refrigeran dan komponen dari sistem terutama alat ekspansi yang dalam hal ini digunakan pipa kapiler maka dari itu dilakukan penelitian optimalisasi variasi panjang pipa kapiler pada mesin pendingin autocascade dengan campuran refrigeran hidrokarbon.
Penelitian ini menginvestigasi sistem refrigerasi autocascade yang menggunakan empat campuran refrigeran dan variasi panjang pipa kapiler dengan diameter 0.028 inch. Refrigeran yang digunakan adalah Butana, propane, etana, dan metana dengan komposisi campuran 29% butana, 50% propane, 19,3% etana, dan 1.7% metana.Variasi panjang pipa kapiler yang dilakukan pada dua titik ekspansi adalah dengan mengkombinasikan antara panjang 15 m dengan 2 m. Penelitian ini menunjukkan bahwa temperatur evaporasi terendah diperoleh pada kombinasi panjang pipa kapiler pada ekspansi I adalah 2 m dan ekspansi II adalah 2 m.

Medical and biomedical sciences in the development treatment require cold storage capable of reaching -80°C temperatures. To achieve such a low temperature refrigeration systems used autocascade. During this autocascade refrigeration systems using refrigerants that contain ozone-depleting substances or the cause of global warming. Hence, it needs alternatives that are environmentally friendly natural refrigerants among which hydrocarbons. Autocascade refrigeration systems have characteristics that depend on the refrigerant and the components of the system, especially the expansion device used in this case the capillary tube from the optimization study was carried out capillary tube length variation in engine cooling autocascade with a mixture of hydrocarbon refrigerants.
This study investigates autocascade refrigeration system that uses a mixture of four refrigerant and variations of the length of the capillary tube with a diameter 0028 inch. Refrigerant used is butane, propane, ethane, and methane with a mixture composition of 29% butane, 50% propane, 19,3% ethane, and 1.7% metana.Variations of capillary tube length is done between two points of expansions that combine 15 m and 2 m lengt. This study shows that the lowest evaporation temperature obtained on a combination of capillary tube length of the expansion I is 2 m and expansion II is 2 m.
"
Depok: Fakultas Teknik Universitas Indonesia, 2012
S53436
UI - Skripsi Membership  Universitas Indonesia Library
cover
Hanif
"Sistem Pendingin Ultra Low semakin berkembang untuk tujuan pengobatan dan medis. Sel hidup atau organ tubuh memerlukan suhu yang sangat rendah dalam penyimpanannya, untuk itu perlu adanya mesin pendingin ultra low, mesin pendingin ini kemudian dikenal dengan Sistem refrigerasi Autocascade. Dalam perkembangannya Sistem refrigerasi Autocascade menggunakan refrigeran yang dapat merusak ozon atau menyebabkan pemanasan global yang segera dilarang pemakaiannya. Oleh karena itu, ditelitilah refrigeran yang lebih ramah lingkungan seperti refrigeran hidrokarbon. Sistem refrigerasi Autocascade memiliki karakteristik yang tergantung pada refrigeran yang digunakan, maka dari itu dilakukan penelitian terhadap pemilihan refrigeran hidrokarbon baik untuk high system (fase liquid) maupun low system (fase gas).
Penelitian ini menginvestigasi sistem refrigerasi autocascade dengan menggunakan tiga campuran refrigeran dengan memvariasikan refrigeran untuk low system (fase gas). Refrigeran yang digunakan adalah Propane dan Butan sebagai refrigeran fase liquid dan Metan dan Etan sebagai refrigeran fase gas. Penelitian ini menunjukkan bahwa pada komposisi yang hampir sama, pemilihan metan sebagai refrigeran fase gas pada sistem menghasilkan sistem yang lebih stabil walaupun temperaturnya hanya sampai -26,8°C.

Ultra Low Refrigeration System growing for medicinal purposes and medical research. Living cells or organs of the body requires very low temperatures in storage, to the need for ultra low engine coolant, engine coolant is then known as Autocascade refrigeration system. In the development of refrigeration systems using refrigerant Autocascade that can damage the ozone or global warming are immediately banned its use. Therefore, scientist are invented more environmentally friendly refrigerants such as hydrocarbon refrigerants. Autocascade refrigeration system has characteristics that depend on the refrigerant used, and therefore conducted a study of selection for hydrocarbon refrigerant on high system (liquid phase) and low system (gas phase).
This study investigates autocascade refrigeration system using refrigerant mixtures of three refrigerants by varying the low system (gas phase) refrigerant. Refrigerants used are Propanee and Butane as a refrigerant liquid phase and the Methane and Ethane as a refrigerant gas phase. This study shows that at nearly the same composition, the selection of methane as a gas phase refrigerant in the system produces a more stable system, although the temperature only up to -26,8°C.
"
Depok: Fakultas Teknik Universitas Indonesia, 2012
S42981
UI - Skripsi Open  Universitas Indonesia Library
cover
Limbong, Eric Pangihutan
"ABSTRAK
Kebutuhan energi saat ini sangatlah tinggi seiring dengan pertumbuhan ekonomi serta perkembangan zaman. Namun sebaliknya, sumber daya energi semakin menipis. Oleh karena itu, kita memerlukan berbagai usaha dalam penghematan energi serta pemakaian produk-produk yang hemat energi. Program energi labeling perlu dilakukan khususnya pada lemari pendingin rumah tangga yang selalu beroperasi serta sangat diminati oleh masyarakat. Pengujian ini dilakukan sebagai salah satu upaya konservasi energi dengan mengadakan pengujian lemari pendingin berdasarkan SNI ISO 15502:2009 dimana kondisi temperature lingkungan dikondisikan sebesar 32 °C. Dari hasil pengujian ini didapatkan konsumsi energi lemari pendingin ini sebesar 1,873 kWh/24 jam dengan M-Packages sebagai beban pendinginan seberat 15 kg.

ABSTRACT
Current energy needs is extremely high along with economic growth and development period. But on the contrary, energy resources is dwindling. Therefore, we need a variety of efforts in energy saving and the use of products that are energy efficient. Energy labeling program needs to be done, especially in the household refrigerator that always operational and in great demand by the public. The test is performed as one of the energy conservation efforts by conducting tests refrigerator based on SNI ISO 15502:2009 where it?s setting ambient temperature conditions of 32°C. From these test results, obtained refrigerator energy consumption of 1.873 kWh/24 h and M-Package as the cooling load with weight 15 kg.
"
2015
S60243
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ahmad Faqih
"Banyak aplikasi dan proses-proses di industri yang membutuhkan temperatur pendinginan sangat rendah, bahkan bidang biomedis membutuhkan cold storage yang mampu mendinginkan hingga temperatur -80°C. Penggunaan sistem refrigerasi siklus tunggal pada aplikasi temperatur sangat rendah menjadi tidak ekonomis karena tinggi nya rasio tekanan dan juga menghasilkan efek pendinginan yang tidak efektif karena rendah nya tekanan evaporasi, sehingga digunakan sistem refrigerasi cascade. Penggunaan refrigeran alamiah, seperti campuran karbon dioksida dan hidrokarbon merupakan alternatif dari penggunaan refrigeran yang mengandung bahan perusak lapisan ozon dan pemanasan global. Pada penelitian ini, dilakukan analisis termodinamika untuk menentukan komposisi campuran karbon dioksida dan hidrokarbon yang optimum. Selanjutnya, dilakukan optimisasi secara termoekonomi untuk menentukan kondisi operasi yang optimum dari sistem refrigerasi cascade, dimana peningkatan efisiensi exergy merupakan sasaran optimisasi secara termodinamika, sedangkan meminimumkan pengeluaran biaya tahunan merupakan sasaran optimisasi secara ekonomi.

There are many industrial applications and processes in which ultra-low temperature is necessary, even the biomedical preservation that needs cold storage providing temperature about -80°C. The use of single cycle refrigeration system for ultra-low temperature application is economically unacceptable caused by the high pressure ratio and results the ineffective evaporating effect as the low evaporating pressure, hence the cascade refrigeration system is applied. Natural refrigerants, such as carbon dioxide and hydrocarbon will be the alternative solutions of the used of ozon depleting and global warming effect refrigerants. In this research, thermodynamic analysis is applied to decide the optimum composition of the mixtures between carbon dioxide and hydrocarbon. Furthermore, thermoeconomic optimization results the optimum operating conditions of the cascade refrigeration system where the increasing of exergetic efficiency is the thermodynamic objective, while the minimization of the annual cost is the economic objective."
Depok: Fakultas Teknik Universitas Indonesia, 2012
S43282
UI - Skripsi Open  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>