Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 44451 dokumen yang sesuai dengan query
cover
Hengky Adryanto
"ABSTRAK
Perbandingan penukar kalor shell and tube dengan penukar kalor plate dilakukan
untuk mengetahui keuntungan dan kerugian masing-masing alat penukar kalor tersebut
pada kondisi tertentu. Dengan mengetahui keuntungan dan kerugian alat penukar kalor,
pemilihan tipe alat penukar kalor pada suatu kondisi operasi , dapat lebih mudah
dilakukan.
Data untuk perbandingan, merupakan data operasi untuk penukar kalor plate.
Data tersebut kemudian digunakan untuk merencanakan penukar kalor shell and tube
dengan bantuan program Transfer Research Institute (HTRI).
Dari pengolahan data, didapatkan perbandingan koefisien perpindahan kalor,
angka Reynolds, faktor pengotoran, penurunan tekanan, ukuran dan berat, kuantitas
fluida, kebocoran, fleksibilitas operasi, perawatan dan konstruksi. Koefisien perpindahan
kalor pada penukar kalor plate lebih besar dibanding penukar kalor shell and tube, yang
berarti, unjuk keija termal alat penukar kalor plate lebih baik. Angka Reynolds pada
penukar kalor shell and tube lebih tinggi dibanding alat penukar kalor plate. Faktor
pengotoran lebih besar pada penukar kalor shell and tube, sedangkan penurunan tekanan
lebih besar pada penukar kalor plate. Ukuran dan berat, serta kuantitas fluida lebih besar
pada penukar kalor shell and tube. Kebocoran tube pada penukar kalor shell and tube
sukar dideteksi, sedangkan kebocoran pada penukar kalor plate adalah keluar alat
penukar kalor, sehingga langsung diketahui. Beban kalor pada penukar kalor plate dapat
disesuaikan dengan merubah jumlah pelat (lebih fleksibel), dan perawatan lebih mudah
karena pelat dapat dilepas untuk pembersihan. Konstruksi penukar kalor shell and tube
memungkinkan teijadinya vibrasi, sedangkan pada penukar kalor plate kemungkinan
tersebut kecil sekali. Pada kondisi ini,secara garis besar penukar kalor plate lebih efektif,
namun, dalam pemilihan harus dipertimbangkan juga faktor-faktor lain, misalnya biaya
modal dan biaya operasi."
1995
S36400
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1993
S35949
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1993
S35948
UI - Skripsi Membership  Universitas Indonesia Library
cover
Adhi Ari Utomo
"Dalam beberapa aplikasi teknologi tertentu, terkadang dibutuhkan suatu alat penukar kalor yang dapat digunakan untuk menaikkan temparatur dua jenis fluida dingin sekaligus. Alat penukar kalor yang dipakai untuk rujuan ini disebut sebagai alat penukar kalor dengan dua fluida dingin. Kinerja dan karakteristik alat penukar kalor ini seperti halnya alat penukar kalor dengan satu fluida dingin tergantung kepada jenis susunan aliran dan kondisi oparasinya.
Salah satu jenis alat penukar kalor ini adalah alat panukar kalor shell and tube dengan dua fluida dingin jenis cross counter flow-one fluid is mixed and the other is unmixed (jenis aliran silang lawan arah dengan satu fluida campur). Pada skripsi ini akan diselidiki kinerja dan karakteristik alat penukar kalor tersebut untuk berbagai kemungkinan konfigurasi aliran kedua fluida dihgin melalui simulasi numenik. Tujuan dan penelitian ini adalah untuk membandingkan kinerja dan karakteristik berbagai konfigurasi aliran alat penukar kalor tersebut. Selain itu, penelitian ini ditujukan pula untuk membuktikan suatu hipotesa yang menyatakan bahwa salah satu bentuk konfigurasi aliran yaitu konfigurasi aliran dengan setiap laluan kedua fluida dingin saling berselingan akan menghasilkan kinerja yang lebih baik. Artinya, kalor yang dipindahkan atau ditransfer oleh konfigurasi ini lebih banyak dibandingkan dengan yang lainnya.
Penelitian ini dilakukan dengan batasan bahwa fluida panas yang digunakan memiliki kapasitas kalor yang lebih besar dibandingkan kapasitas kalor yang dimiliki oleh kedua fluida dingin yang hendak dinaikkan temperaturnya. Dalam hal ini fluida panas bertindak sebagai fluida maksimum dan kedua fluida dingin sebagai fluida minimum. Jenis konfigurasi aliran yang akan diselidiki hanya empat kemungkinan konfigurasi.
Dari penelitian diperoleh bahwa konfigurasi aliran dengan setiap laluan kedua fluida dingin saling berselingan memiliki kinerja dan karakteristik yang lebih baik dibandingkan ketiga konfigurasi aliran lain yang diteliti.

At certain application of technology it is sometime needed the heat exchanger that could be used to rise the temperature of two kind of cold fluids. The heat exchanger that is used for this purpose is called as the heat exchanger with two cold fluids. The performance and characteristics of this heat exchanger depends on the flow arrangement ot work fluids and the operation conditions.
One type of this heat exchanger is shell and tube-cross counter flow heat exchanger with one fluid is mixed and the other is unmixed. This thesis would discuss about the performance and characteristics of this heat exchanger for some possibility of flow configurations of both cold fluids. The purpose of this research is to compare the performance and characteristics of those flow configuralion.Besides, this research is proposed to prove the thruth of the hypothesis stating that the flow configuration that make the hot fluid cross succesively each one-pass of both cold fluids has the best performance among them.
This discussion is constrained by the condition whore the heat capacity of hot fluid is bigger then the heat capacity of both cold fluids. It means that the hot fluid acts as a maximum fluid and cold fluid acts as a minimum fluid.
From this research, it is found that the flow configuration that make the hot fluid cross succesively each one-pass of both cold fluids gives the performance and characteristics that is better than the other flow configurations.
"
Depok: Fakultas Teknik Universitas Indonesia, 2000
S37205
UI - Skripsi Membership  Universitas Indonesia Library
cover
Betarto Fitriaji
"Salah satu peralatan yang menerapkan prinsip-prinsip Perpindahan Kalor yang paling umum digunakan adalah Alat Penukar Kalor. Prinsip keja Alat Penukar Kalor adalah memindahlnagz kalor dari fluida panas ke fluida dingin. Pada beberapa aplikasi khusus di lapangan, dibutuhkan Alat Penukar Kalor yang dapat memanaskan dun fluida dingin sekaligus, dan disebut Alat Penukar Kafor dengan Dua Fluids Dingin. Salah satu bemulmya adalah Alat Penukar Kalor Shell and Tube dengan aliran silang-Iawan arah dengan banyak laluan, dengan satu fluida campur dan yang lainnya tak campur.
Kineqa suatu Alat Penukar Kalor adaiah kemampuan memindahkan kaior per saman wakm, atau laju perpindahan kalor (q). Sebagaimana Alat Penukar Kalor biasa, kinerja Alat Penukar Kalor dengan Dua Fluida Dingin ditentukan oleh jenis susunan aliran dan kondisi operasinya. Pada Alat Penukar Kalor dengan Dua Fluida Dingin, ada satu faktor lagi yang menentukan kinerjanya, yaitu konjigurasi aliran anlara kedua fIuida dinginnya. Selain itu, juga diperhitungkan profil kecepatan aliran turbulen dari fluida panas dalam shell Pada beberapa contoh aplikasi, digunakan koryigurasi dimana aliran kedua fluida dingin saling berselingan tiap satuan Ialuan.
Skripsi ini bertujuan untuk mengetahui korgfigurasi seperti apa yang memiliki kinerja terbaik dengan melakukan simulasi perhinmgan menggunakan program komputer berbasis bahasa pemrograman Pascal. Dengan menjalankan serangkaian perhimngan dalam suatu program, dapat dibandingkan kinerja Alat Penukar Kalor dengan Dua Fluids Dingin. Di sini disimuiasikan empat jenis konfigurasi aliran fluida dingin, yang memvariasikan jumlah Ialuan fluida dingin sebelum saling berselingan.
Hasil skripsi ini, yang dijabarkan dalam bentuk grafik dan tabel memmjukkan bahwa keempat jenis konfigurasi mempunyai kemungkinan untuk menghasilkan kinerja yang terbaik yang ditentukan oleh kondisi masukan, yaitu laju aliran massa dan temperarur masuk dari ketiga fluida kerjanya.

There are many tools that we use in everyday lives that apply Heat Transfer princnzrles. The most common one is Heal Exchanger. lt works by exchanging heat from hot fluid to cold fluid At some special applications, there are needs to use Heat Exchanger that can heat two coldfluiais simultaneously. It is called Two Cold Fluids Heal Exchanger: One of its types is Shell and Tube Heat Exchanger, multi pass cross-counter flow type, with one fluid mixed and others are unmixed.
Heat Exchanger's performarzce is the capability to transfers heat at certain limes, or the heat transfer rate (q). Like the usual Heal Exchanger; its flow type and operational condition determirie the Two Cold Fluids' Heat Exchanger's performaunce. There is another variable that determines its perjformance, which is the flow configuration between the two cold fluids. The involvement of turbulent velocity profiles that works at the hot fluid flow in the shell also gives some in_)7uences. At some applications examples, the configuration where the cold fluids airermate every one pass is being used.
This script's purpose is to determine what hind of configuration between two eoldfluials has the best performance. It is conducted by doing mathematical simulation using a special computer program based on Pascal programming ikmguage. By doing the simulation in some various inputs, the comparison of configuration peU"ormance is obtained Here, four kinds offlow configurations between the two cold fluids; which are different in the number of pass before they are alternated are calculated.
This script's result, that is shown in graphics and tables, shows that all four configurations has chance to have the best performance that is determined by the inputs, which is the mass flow rate ana' the input temperature of the three working fluids.
"
Depok: Fakultas Teknik Universitas Indonesia, 2001
S37086
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1993
S36714
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1995
S36423
UI - Skripsi Membership  Universitas Indonesia Library
cover
Bagus Fadhlurrohman
"Sistem pendingin dan pemanas banyak digunakan khalayak umum. Ini membuat penggunaan energi yang tinggi disertai dengan efek pemanasn global.
Solusi dari permasalahan ini ialah menggabungkan kedua sistem tersebut dimana panas hasil pendinginan akan digunakan untuk memanaskan. Salah satunya untuk memanaskan air. Komponen yang berperan penting ialah heat exchanger, dalam penulisan ini dipilih Shell and Tube dikarenakan kapasitas besar dan perawatan yang mudah.
Didapatkan dari hasil analisa pada sistem ideal bahwa kapasitas pemanasan paling tinggi ialah ketika temperatur kerja AC 20oC dengan nilai 2,9 kW dengan waktu pemanasan 31 menit 18 detik dan untuk paling rendah pada temperatur kerja AC 25oC dengan nilai 2,8 kW dengan waktu pemanasan 32 menit 30 detik.

Cooling and heating systems are widely used by public. This makes high energy usage accompanied by a global heating effect.
The solution to this problem is to combine the two systems where the heat from the cooling will be used for heating. One of them is to heat water. The component that plays an important role in the heat exchanger. In this paper, Shell and Tube was chosen because of its large capacity and easy maintenance.
It is obtained from the analysis on the ideal system that the highest heating capacity is when the AC working temperature is 20oC with a value of 2,9 kW with a heating time of 31 minute 18 seconds and for the lowest in 25oC of AC working temperature with a value of 2,8 kW with a heating time of 32 minute 30 seconds.
"
Depok: Fakultas Teknik Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Candra Damis Widiawaty
"Riset ini bertujuan melakukan analisis prosedur desain dan redesain alat penukar kalor tipe shell and tube dengan CFD pada reboiler turbin mikro bioenergi proto x-2 dan CO2 stripper reboiler PT Pupuk Iskandar Muda. Metode desain dimulai dari kalkulasi manual metode Kern dan konstrain desain pressuredrop di sisi tube harus di bawah 277 Pa. Kemudian dilakukan simulasi 1 fasa SolidWork 2010 dan 2 fasa dengan sofware CFDSof. Metode redesain diawali dari analisis kondisi terpasang dilanjutkan dengan redesain dengan 3 model. Fokus redesain adalah untuk menganalisis korosi pendidihan dengan CFD dan perubahan desain untuk mengurangi fraksi uap.
Eksperimen reboiler turbin dan hasil simulasi menunjukkan peningkatan temperatur pada titik ukur 1 lebih cepat dibandingkan dengan titik ukur 2, sehingga uap lebih dulu terbentuk pada titik ukur 1. Hasil simulasi menunjukkan pembentukan uap mulai terjadi pada jarak 85 mm dari tubesheet. Berdasarkan simulasi 2 fasa, model redesain 2 yaitu posisi outlet shell 880 mm dari tubesheet adalah yang terbaik karena proses pendidihan lebih sedikit yang direpresentasikan oleh pembentukan fraksi uap tertinggi hanya 0,0002. Dengan mengunakan simulasi CFD, desain reboiler CO2 stripper reboiler lebih baik dibandingkan desain reboiler turbin, karena pada reboiler CO2 stripper reboiler penguapan terjadi mendekati outlet sehingga uap lebih lebih mudah keluar.

The aimed of this researched is analized procedure of design and redesign shell and tube heat exchanger used CFD for micro bioenergy gas turbine proto x-2 and CO2 stripper reboiler?s PT Pupuk Iskandar Muda. The design method was started with manual calculation using Kern method and the constrain was pressuredrop exhaust gas must be under 277 Pa. The next step was simulated the model with SolidWork 2010 for one phase and CFDSof for two phase. The method of redesign was previously analized the existing condition and then continued with changed the original model with 3 redesign model which is produced less vapor fraction.
The experiment and simulation of turbine reboiler showed that the temperature of water increasing faster at measuring point 1 than measuring point 2 therefore water vapor started at 85 mm from inlet of exhaust gas. The redesign 2 which is the distance outlet 880 mm from tubesheet was the best design because it's produced the lowest vapor fraction 0,0002. On all the CFD could showed the pendidihan process for both of the reboiler, it showed that the CO2 stripper reboiler design was better than the turbine reboiler because the vaporation was started near the outlet.
"
Depok: Fakultas Teknik Universitas Indonesia, 2012
T31064
UI - Tesis Open  Universitas Indonesia Library
cover
Sofwan Haris
"ABSTRAK
Bahan dasar untuk membuat plastik yaitu ethylene. Sebelum ethylene diolah menjadi bahan baku untuk membuat plastik, ethylene tersebut terlebih dahulu disimpan dalan suatu tangld penampungan. Di dalam tangki penampungan tersebut ethylene mengalami penguapan karena temperatur lingkungan yang cukup panas. Supaya ethylene yang berbentuk uap tidak terbuang seoara percuma dan supaya masih dapat dimanfaatkan lagi untuk diolah menjadi bahan baku untuk membuat plastik, rnaka ethylene yang berbentuk uap tersebut harus diubah menjadi bentuk eair kembali_
Alat yang digunakan untuk mencairkan ethylene yang berbentuk uap menjadi cair di PT. X adalah penukar kalor she!! and lube type BKU. Dengan dapat dicairkan kembali ethylene yang berbentuk uap tersebut, perusahaan X dapat menghemat biaya produksi dengan menekan biaya pembelian bahan baku.
Kalor maksimum dan minimum yang diserap oleh R-22 pada kapasitas kompresor 75% dari data hasil perhitungan adalah sebesar 386,02 kW dan 366 kW. Sedangkan kalor maksimum dan minimum yang diserap oleh R-22 pada kapasitas kompresor 100% dari data hasil perhitungan adalah sebesar 526,91 kW dan 466,26 kW.
Kalor maksimum dan minimum yang dilepas oleh ethylene pada kapasitas lcompresor 75% dari data hasil perhitungan adalah 388,19 kW dan 379,12 kW.
Sedangkan kalor maksimum dan minimum yang dilepas ethylene pada kapasitas kompresor 100% dari data hasil perhitungan adalah 546,35 kW dan 483,14 kW, Sedangkan dari data desain pertukarall kalomya adalah sebesar 571 kW.
Efektifitas rata-rata penukar kalor pada kapasitas kompresor 75% dan data hasil perhitungan adalah sebesar 93,67 % dan efektititas rata-rata penukar kalor dari data hasil perhitungan pada kapasitas 100% dari data hasil perhitungan adalah sebesar 91,46 %, sedangkan efektifitas disain penukar kalor sebesar 92,30%.

"
2000
S37639
UI - Skripsi Membership  Universitas Indonesia Library