"Menara pendingin dibutuhkan dalam sistem tata udara pada gedung sebagai pendingin air kondenser. Menara pendingin yang digunakan pada penelitian ini bertipe forced draft - counter flow – indirect/ closed evaporative cooling tower. Penelitian ini berusaha untuk menunjukkan karakteristik performa menara pendingin sistem tertutup berupa nilai efektivitas, NTU (Number of Transfer Unit), kapasitas pendinginan, dan koefisien perpindahan kalor dan massa keseluruhan dari menara pendingin. Eksperimen dilakukan pada penukar kalor berupa koil dengan susunan bersilangan dengan diameter 3/8 inchi, yang memiliki jalur parallel.
Hasil eksperimen kemudian dibandingkan dengan korelasi perpindahan kalor dan massa dasar yang ada pada textbook, juga dipadukan dengan simulasi CFD untuk menginvestigasi proses fisik yang terjadi di dalam kolom menara pendingin. Baik eksperimen, perhitungan teoritis, dan simulasi CFD, divariasikan dengan nilai laju massa air hangat, udara dingin, dan air semprot yang berbeda untuk memberikan deskripsi yang jelas tentang karakteristik performa dari menara pendingin sistem tertutup.

Cooling towers are needed in a HVAC sistem in buildings to reject heat from cooling water of a condenser. The type of cooling tower used in this research is forced draft - counter flow – indirect/ closed evaporative cooling tower. This research try to show the performance characteristics of Closed Circuit Cooling Tower (CWCT), specifically the effectiveness value, NTU (Number of Transfer Unit), cooling capacity, and overall coefficient of heat and mass transfers of CWCT. Experiment doing in heat exchanger coils (tube bundle) with stagerred line and 3/8 inch diameter with multipath (parallel path).
The result of experiments compared with basic heat and mass transfer correlations in textbook, and combined with CFD simulation to investigate physical process that occurred in CWCT column. Neither the experiments, theoretical calculations, and CFD simulations, are variated with different mass flow of warm water, cold air, and spray water, to describe the performace characteristics of CWCT.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S53361
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muhammad Hafil Nugraha
"Dalam suatu siklus kondenser perpendingin air, air pendingin kondenser menyerap panas dari fenomena kondensasi refrijeran. Air pendingin tersebut perlu didinginkan kembali menggunakan sistem menara pendingin.Terdapat dua jenis menara pendingin evaporatif yakni sistem terbuka dan tertutup. Dari kedua jenis menara pendingin ini terdapat perbedaan unjuk kerja yang perlu ditinjau. Unjuk kerja suatu menara pendingin bergantung pada nilai efektifitas, bilangan NTU, dan kapasitas pendinginan yang dihasilkan.Untuk menara pendingin terbuka eksperimen dilakukan dengan menggunakan paking di dalam menara dan tidak menggunakan paking (non-paking) pada menara pendingin tertutup digunakan penukar kalor berupa koil dengan susunan bersilangan dengan diameter 3/8 inchi, yang memiliki jalur parallel.Peninjauan terhadap perbedaan unjuk kerja antara dua jenis menara pendingin perlu dilakukan dengan membandingkan hasil dari percobaan.

In water cooled condenser, heat from the process of refrigerant condensation absorbed by cooling water. Cooling tower used to dissipate heat from water cooled refrigeration. There are two basic types of evaporative cooling devices. The first of these, the direct contact or open cooling tower. The second is indirect contact or closed-circuit cooling tower.The comparison perfomance between type of cooling tower must be known. Perfomance of cooling tower depends from the effectiveness, Number Transfer Unit (NTU), and cooling capacity.Experiment in open cooling tower doing with packing inside and non-packing. In closed cooling tower used the heat exchanger coils (tube bundle) with stagerred line and 3/8 inch diameter with multipath (parallel path)."
Depok: Fakultas Teknik Universitas Indonesia, 2013
S53338
UI - Skripsi Membership  Universitas Indonesia Library
cover
Benedictus Edwin Nugraha
"Cooling tower sangat dibutuhkan industri karena merupakan bagian dari utilitas yang banyak digunakan dalam menjaga stabilitas suhu dan kinerja mesin. Cooling Tower merupakan salah satu komponen yang digunakan pada proses produksi yang beroperasi menggunakan energi listrik. Dalam memenuhi tuntutan perusahaan untuk melakukan peningkatan efisiensi energi listrik, maka pengaplikasian Variable Frequency Drive (VFD) pada motor fan cooling tower adalah salah satu usaha yang dilakukan di PT CS2 Pola Sehat Bogor. Dari hasil analisis data yang dilakukan maka diperoleh energi listrik motor fan cooling tower bila dioperasikan tanpa VFD sebesar 5,13 kWh dan saat menggunakan VFD sebesar 4,57 kWh. Perbandingan penggunaan energi listrik motor fan cooling tower menggunakan VFD lebih rendah sebesar 0,56 kWh dibandingkan tanpa VFD dengan meningkatkan efisiensi energi listrik sebesar 10,95% atau sebesar Rp453.673 dalam satu bulan. Dari praktik keinsinyuran ini dilakukan analisis K3L, dimana motor fan cooling tower dengan VFD meningkatkan durabilitas motor sehingga menurunkan resiko terjadinya motor terbakar. Adapun asas-asas kode etik keinsinyuran yang diperoleh dan meningkatkan nilai-nilai profesionalisme dari bakuan kompentensi yang diperoleh juga.

Cooling towers are needed by the industry because they are part of the utilities that are widely used in maintaining temperature stability and engine performance. Cooling Tower is one of the components used in the production process that operates using electrical energy. In meeting the company's demands to increase the efficiency of electrical energy, the application of Variable Frequency Drive (VFD) to cooling tower fan motors is one of the efforts undertaken at PT CS2 Pola Sehat Bogor. From the results of the data analysis carried out, it is obtained that the electric energy of the cooling tower fan motor when operated without a VFD is 5.13 kWh and when using a VFD it is 4.57 kWh. Comparison of the use of electric energy for cooling tower fan motors using a VFD is lower by 0.56 kWh than without a VFD by increasing the efficiency of electrical energy by 10.95% or Rp.453,673 in one month. From this engineering practice an HSE analysis was carried out, where a cooling tower fan motor with VFD increases the durability of the motor thereby reducing the risk of the motor being burnt. As for the principles of the engineering code of ethics that are obtained and increase the values of professionalism from the competency standards that are also obtained."
Depok: Fakultas Teknik Universitas Indonesia, 2023
PR-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Ibnu Thooriq Ramadhan
"Menara pendingin adalah suatu unit yang membantu proses pembuangan kalor. Maka, efektivitas thermal adalah sebuah variabel yang vital untuk performa dari menara pendingin. Presipitasi kerak dapat menjadi faktor yang sangat mengganggu efektivitas thermal dari unit penukar kalor karena sifat natural nya yang mempunyai resistansi thermal yang tinggi. Proses ozonasi diharapkan dapat menurunkan potensi presipitasi kerak yang mana meningkatkan performa thermal menara pendingin. Air pendingin pada menara disirkulasikan lalu diaplikasikan dengan ozon dan sinar UV. Penelitian ini bertujuan untuk mengetahui karakteristik efek ozonasi terhadap total resistansi thermal fouling dari menara pendingin forced draft - counter flow - sistem tertutup serta kualitas air sirkulasi melalui metode Practical Ozone Scaling Index dan Langelier Saturation Index. Metode yang digunakan dalam mengetahui kualitas air menara pendingin sistem tertutup adalah dengan melakukan uji laboratorium seperti AAS, Titrimetric, Gravimetrik, dan Spectrophotometric. Hasil yang didapat dari penelitian ini menunjukkan bahwa dengan aplikasi ozon, total resistansi thermal menara pendingin sistem tertutup menurun sebesar 7 x10-6 m2K/W. Ozon juga dapat meningkatkan kualitas air sirkulasi menara pendingin sistem tertutup.

Cooling tower is a unit that helps heat dissipation process. Thus, thermal effectiveness is a vital variable for performance of the cooling tower. Scale precipitation can be a very disturbing factor to the thermal effectiveness of the heat exchange unit due to its natural properties which have high thermal resistance. The ozonation process is expected to decrease the potential of precipitation of the scale which improves the cooling tower thermal performance. The cooling water is circulated from the tower, then applied by ozone and UV ray. This study aims to determine the characteristics of the effects of ozonation on the overall thermal fouling resistance of forced draft type ndash counter flow closed system cooling towers and the quality of water circulation through Practical Ozone Scaling Index and Langelier Saturation Index methods. Water quality of closed system cooling towers is determined by conducting laboratory tests such as AAS, Titrimetric, Gravimetric, and Spectrophotometric. The results obtained from this study indicate that by the presence of ozone, the overall thermal tower resistance of the closed system cooling towers reduced by 7 x10 6 m2K W. Ozone can also improve the water quality of closed system cooling towers."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Abdul Aziz Rohman Hakim
"Setelah 30 tahun dioperasikan, kinerja menara pendingin RSG-GAS mengalami penurunan. Perlu dilakukan pemodelan perpindahan panas dan massa yang terjadi di dalam menara pendingin. Pemodelan perpindahan panas dan massa dilakukan pada bagian fill menara pendingin. Penelitian ini mengkaji perubahan temperatur air dan udara serta rasio kelembaban udara dari sisi masuk sampai sisi keluar fill. Kajian dilakukan dengan pendekatan Kloppers, Klimanek dan Analogi. Hasil perhitungan kemudian dibandingkan dengan data desain menara pendingin. Hasil analisis menunjukkan bahwa pendekatan Kloppers dan Klimanek 39,26 di bawah desain dan pendekatan Analogi 0,9 di atas desain. Pendekatan Analogi memberikan hasil perhitungan paling mendekati data desain.

After 30 years of operation, the performance of RSG GAS cooling towers has decreased. It is necessary the heat and mass transfer modeling that occurs inside the cooling tower. Modeling of heat and mass transfer is done on the cooling tower fill section. This study examines changes in water and air temperature and air humidity ratio from the inlet side to the outlet fill. The study was conducted using Kloppers, Klimanek and Analogical approach. The results are then compared with the cooling tower design data. The results of the analysis show that the Kloppers and Klimanek approach is 39.26 under the design and the Analogical approach is 0.9 above the design. Analogical approach gives the most closed result of the design data.
"
Depok: Fakultas Teknik Universitas Indonesia, 2018
T51016
UI - Tesis Membership  Universitas Indonesia Library
cover
Rainanda Muhammad Ajnannadhif
"Menara pendingin adalah suatu unit yang dugunakan untuk proses pembuangan dalam sebuah sistem pendingin. Efektivitas thermal adalah suatu variabel yang sangat penting untuk menentukan hasil performa menara pendingin. Timbulnya korosi, lumut, dan presipitasi kerak dapat menghambat perpindahan panas sehingga dapat mengganggu tingkat efektivitas thermal dari menara pendingin tersebut. Bukan hanya mengurangi efektivitas termal saja, namun juga bisa merusak menara pendingin. Penelitian ini bertujuan untuk mengetahui pengaruh ozonasi terhadap faktor-faktor penghambat tersebut. Proses ozonasi ini diharapkan akan mengurangin pertumbuhan faktor-faktor tersebut. Metode yang dugunakan adalah dengan air pendingin dari basin disirkulasikan dengan sebuah ssstem baru. Dalam sistem baru tersebut air dari basin akan disuntikan ozon, lalu air kembali ke basin. Selanjutnya sampel air akan di uji di laboratorium menggunakan metode AAS, Titrimetric, Gravimetric, Spectrophotometric untuk mengetahui kualitas air. Data yang didapat dari laboratorium adalah PH, SO4, Konduktivitas Elektrik, Fe, TDS, Ca, Alkalinity, Mg, Na, Cl. Data tersebut selanjutnya dimasukan kedalam penghitungan menggunakan metode Practical Ozone ScalingIndex dan Langelier Saturation Index untuk mengetahui kualitas air sirkulasi. Hasil yang didapat dari penelitian ini mununjukan bahwa aplikasi ozon dapat meningkatkan kualitas air dikarenakan TDS dan EC pada air siklus yang digunakan menurun. Jumlah konsentarasi siklus air yang aman digunakan pun meningkat 2 kali lipat.

A cooling tower is a unit that is used for the disposal process in a cooling system. Thermal
effectiveness is a very important variable to determine the performance of the cooling
tower. The emergence of corrosion, moss, and crustal precipitation can inhibit heat
transfer so that it can disrupt the level of thermal effectiveness of the cooling tower. Not
only does it reduce thermal effectiveness, but it can also damage the cooling tower. This
study aims to determine the effect of ozonation on these inhibiting factors. This ozonation
process is expected to reduce the growth of these factors. The method used is with cooling
water from the basin circulated with a new system. In the new system water from the
basin will be injected with, then the water will return to the basin. Furthermore, water
samples will be tested in the laboratory using the AAS, Titrimetric, Gravimetric,
Spectrophotometric method to determine water quality. Data obtained from the laboratory
are PH, SO4, Electrical Conductivity, Fe, TDS, Ca, Alkalinity, Mg, Na, Cl. The data is
then entered into the calculation using the Practical Ozone Scaling Index and Langelier
Saturation Index method to determine circulating water quality. The results obtained from
this study show that the application of ozone can improve water quality because TDS and
EC in the cycle water used decrease. The amount of safe water cycle concentration is also
increased twice
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rifqi Miftah Majduddin
"Menara Pendingin adalah suatu unit yang dapat membantu melakukan perpindahan kalor dimana kalor tersebut sudah tidak dibutuhkan lagi. Dalam operasi menara pendingin, ada beberapa faktor yang dapat dijadikan tinjauan dalam mengukur performa dari menara pendingin. Banyaknya bakteri di dalam menara pendingin menyebabkan presipitasi kerak yang dapat mengganggu efektivitas thermal dari menara pendingin dikarenakan kerak-kerak tersebut akan menghambat laju perpindahan kalor karena mempunyai resistansi thermal yang tinggi. Ada beberapa cara untuk mengurangi laju pertumbuhan dari kerak, salah satunya adalah ozonasi. Ozonasi adalah injeksi ozon pada air pendingin menara pendingin untuk mengurangi potensi dari presipitasi kerak yang akan meningkatkan performa dari menara pendingin.
Penelitian ini bertujuan untuk mengetahui karakteristik efek ozonasi terharap performa dari menara pendingin dan kualitas air pendingin pada menara pendingin sistem tertutup. Metode yang digunakan untuk menguji kualitas air adalah pengujian dengan alat ukur yang dicelupkan setiap harinya dan uji laboratorium seperti AAS, Titrimetric, Gravimetrik, dan Spectrophotometric.
Hasil yang didapat pada penelitian ini adalah karakterisitik laju performa setiap harinya dan laju kualitas air setiap harinya maupun saat sebelum dan sesudah ozonasi. Hasil dari nilai efektivitas yang didapat adalah 0.12 % untuk nilai terkecil dan 8.74 % untuk nilai terbesar. Ozonasi terbukti dapat meningkatkan kualitas air menara pendingin tetapi belum terbukti dapat meningkatkan performa atau efektivitas menara pendingin untuk jangka waktu ozonasi selama 15 hari.

Cooling tower is a unit or system that used for heat transfer process where the heat is not useful anymore. There is several factor in the cooling tower operations that can observed for cooling tower performance. The large amount of bacteria on cooling tower become potential of scale precipitation that can decrease the cooling tower thermal effectivity because of the scale will act as inhibitor for heat transfer rate since the scale has high value of thermal resistance. There are several method for reducing scale precipitation growth rate, one of them is ozonation or ozone injection method. The ozone will injected to the cooling water to reduce the scale precipitation growth rate that can decreases the cooling tower performance.
This research intends to find the characteristic of ozonation effect from cooling tower performance and water quality. The method for water quality checking are AAS method, Titrimetric, Gravimetric, and Spectrophotometric.
The output of this research are characteristic of cooling tower performance each day and rate of water quality before and after ozonation and each day. The effectiveness value results obtained in this research was 0.12 % for the lowest value and 8.74 % for the highest value. Ozonation has been proven to improve water quality rate of cooling towers but has not been proven to improve the performance or effectiveness of cooling towers for an ozonation period of 15 days.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library