Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 217535 dokumen yang sesuai dengan query
cover
cover
Setyo Sarwanto Moersidik
"Limbah cair rumah sakit yang mengandung limbah klinis jika dibuang ke badan penerima tanpa pengolahan lebih dahulu dapat membahayakan lingkungan sekitarnya. Oleh karena itu, pengolahannya diperlukan untuk menghasilkan effluen yang sesuai dengan standar effluen yang diisyaratkan yang diindentifikasikan dalam parameter Padatan Tersuspensi, Zat Organik (KMnO4),BOD, COD, N dan P.
Salah satu cara mereduksi kontaminan yang terkandung dalam limbah cair rumah sakit adalah dengan proses pengolahan secara fisis-kimiawi dengan menggunakan bahan koagulan PAC (Polyaluminiumrium Chloride) dikenal sebagai koaguian yang mampu mereduksi secara optimal kandungan turbiditas dalam pengolahan air bersih.
Penelitian ini dimaksudkan untuk mengetahui efektifitas reduksi PAC jika digunakan dalam pengolahan limbah cair, khususnya limbah cair rumah sakit. Penelitian dilakukan di lapangan dengan menggunakan alat simulasi pengolahan fisis-kimiawi. Pemeriksaan dilakukan terhadap kondisi air baku dan air hasil olahan dengan parameter uji melipuli pH, Turbiditas, Padatan Tersuspensi, Zat Organik (KMnO4), BOD, COD. N-Amonia dan P. Sebelum penelitian, terlebih dahulu dilakukan Jar test guna mengetahui dosis optimum yang akan diterapkan selama penelitian. Dengan membandingkan hasil pemeriksaan air olahan dengan hasil pemeriksaan air bakunya dapat diketahui tingkat reduksi dari koagulan PAC yang menunjukkan efektifitasnya.
Dari hasil penelitian, diperoleh bahwa PAC jika digunakan dalam pengolahan limbah cair - khususnya limbah rumah sakit - memang cukup efektif dalam mereduksi turbiditas, yaitu dengan dosis 50 mg/l didapat reduksi turbiditas maksimum 79%; tetapi tidak cukup efektif dalam mereduksi kontaminan lainnya dimana reduksi pada kontaminan lainnya maksimum hanya 56% (Zat Organilr KMnO4). Penggunaan unit saringan pasir cepat sesudah proses koagulasi tidak banyak manambah tingkat reduksi kontaminan, dimana turbiditas tersebut hanya naik menjadi 82%. Selain hasil penelitian yang berkaitan dengan penggunaan koagulan PAC lersebut, diperoleh pula tingkat effisiensi yang rendah dari alat simulasi yang pada umumnya berada di bawah harga kisaran effisiensi pengolahan teoritis."
Depok: Fakultas Teknik Universitas Indonesia, 1994
LP-pdf
UI - Laporan Penelitian  Universitas Indonesia Library
cover
cover
Hari Fatwa Triardianto
"Flotasi telah lama digunakan sebagai proses separasi logam-logam berat dari air limbah.biasanya pada proses ini digunakan oksigen sebagai difusernya. Akan tetapi, pada penelitian ini digunakan campuran udara-ozon sebagai ifusernnya. Dengan ditambahkan ozon yang memiliki beberapa kelebihan dibandingkan oksigen, proses kinerja proses flotasi diharapkan akan meningkat. Pada proses flotasi diperlukan beberapa bahan kimia tambahan, diantaranya surfaktan dan koagulan. Oleh karena itu perlu diketahui berapa dosis yang dibutuhkan untuk mendapatkan hasil yang optimum.
Pada proses flotasi ini digunakan tiga jenis limbah, yaitu limbah besi, limbah tembaga, dan limbah nikel. Pertama-tama air limbah yang dibuat dari garamnya dicampur dengan zeolit yang berfungsi sebagai bahan pengikat, Sodium Lauril Sulfat (SLS) sebagai surfaktan, NaOH sebagai pengatur pH, dan Polyaluminum chloride (PAC) sebagai koagulan. Kemudian limbah yang telah dicampur dimasukkan ke dalam tangki flotasi. Campuran udara-ozon sebagai difuser dialirkan sehingga dapat mengangkat limbah logam ke permukaan sehingga dapat dipisahkan dari air. Sebelum proses flotasi dilakukan, persiapan-persiapan yang dilakukan adalah preparasi zeolit dengan pemanasan dan karakterisasinya dengan uji analisis BET, serta uji produktivitas ozonator dengan metode iodometri. Sampel yang diambil dianalisis kandungan logamnya, pH, DO, dan CODnya.
Hasil dari penelitian ini menunjukan bahwa penambahan dosis PAC dan SLS dapat meningkatkan persentase pemisahan logam dari air limbah hingga mencapai diatas 95%. Akan tetapi kenaikan tersebut memiliki kondisi optimum. Dosis PAC optimum untuk tembaga dan besi adalah 0,133 g/L sedangkan untuk nikel adalah 0,067 g/L. Dosis optimum SLS untuk ketiga logam tersebut adalah 0,4 g/L. Dengan dosis PAC dan SLS optimum didapat persentase pemisahan logam besi sebesar 99,67%, sedangkan persentase pemisahan logam tembaga sebesar 89.39%, dan persentase pemisahan logam nikel sebesar 99,15%.

Flotation has been use for separation heavy metals from wastewater for many years. In convencional flotation, oxygen is used as diffuser. But in this research, ozon-air mixed is used as diffuser. By adding ozon which has advantage over oxygen, the efectivness of the process may increase. Flotation process need some chemical agent, such as coagulant and surfactant. Because of that, important to know how much its needed to get the optimum result.
On this research is used three kind of metal as a wastewater, that is: iron, copper, an nickle. The first step of this experiment is mix the wastewater with zeolit as a bonding agent, Sodium Lauryl Sulfate (SLS) as a surfactant, NaOH as a pH adjuster, and Polyaluminum chloride (PAC) as a coagulant. After that, the mixed wastewater is put on the flotation tank. Ozone-air diffuser is flowed from the bottom of the tank to make the bubble which pushed the flok up so it can be remove from the water. Before the flotation process, the thing that should do is preparation and caracterisation of bonding agent, sng ozonator productivity test. The analysis for the sampel is metal contens, pH, DO, and COD.
The result is by using PAC and SLS, the efficiency of the process is increase up to 95 %. But ther is an optimum point. For iron and copper, the optimum dosage of PAC is 0.133 g/L, and for nickel is 0.067 g/L. The optimum dosage of SLS for each of three metal is 0.4 g/L. With this optimum dosage, iron removal persentage is 99.67%,, copper removal persentage is 89.39%, an nickle removal persentage is 99.15%.
"
Depok: Fakultas Teknik Universitas Indonesia, 2006
S49497
UI - Skripsi Membership  Universitas Indonesia Library
cover
Reny Sri Futsy Yama
"Rumah sakit Pusat Pertamina Jakarta 'dalarn perkembangannya hendak meningkatkan kapasitas layan, yaitu dari 333 bed menjadi 501 bed. Dengan demikian tentunya akan meningkatkan debit Iimbah cair yang dihasilkannya pula.
Tujuan penelitian ini adalah melakukan Studi evaluasi mengenai Unit Pengolahan Limbah (UPL) Cair di Rumah Sakit Pusat Pertamina Jakarta serta merencanakan pengernbangan dari UPL yang ada untuk mendapatkan effluen yang memenuhi baku mutu sesuai dengan SK Gubemur KDKI Jakarta no 1502 tahun 1995. Pengumpulan data dilakukan dengan cara pengamatan, wawancara, pengambilan sample buangan cair dan juga mengambil garnbar yang sekiranya diperlukan.
Karakteristik limbah dari RSPP-Jakarta ini tergolong pada limbah domestik yang mengandung bakteri patogen yang berkosentrasi tinggi. Pengolahan limbah dilakukan secara biologis. Perencanaan Pengembangan UPL di RSPP-Jakarta ini mencakup comminutor, screening, bak ekualisasi, grit chamber, bak prasedimentasi, CMAS, bak sedimentasi, desinfeksi dan Hltcr press."
Depok: Fakultas Teknik Universitas Indonesia, 1996
S34556
UI - Skripsi Membership  Universitas Indonesia Library
cover
Meirlin Ramadhani Piliang
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2010
S26470
UI - Skripsi Open  Universitas Indonesia Library
cover
Rumengan, Grace S.
"ABSTRAK
Rumah Sakit merupakan penghasil limbah medik atau klinis terbesar yang mengandung potensi bahaya bagi kesehatan masyarakat dan lingkungan karena tercemar bahaya infeksi, toksik dan radioaktif.
Penelitian ini bertujuan untuk mengetahui manajemen limbah cair klinis di rumah sakit Sint Carolus. Secara khusus, tujuan penelitian ini adalah untuk memperoleh gambaran tentang pengolahan limbah cair klinis, dan mengidentifikasi karakteristik kualitas limbah cair klinis sebelum dan sesudah pengolahan dibandingkan dengan baku mutu lingkungan yang berlaku.
Hasil analisa efluen limbah cair klinik bila dibandingkan dengan baku mutu lingkungan, untuk parameter BOD, pH, suhu, TSS, amoniak, (termasuk logam berai, zat beracun, minyak dan lemak) menunjukkan kadar di bawah baku mutu yang berlaku. Sedangkan fosfat (>2mg/i) dan perkiraan jumlah kuman E.coli/100ml dan Koliform tinja (>10.000/100mi) di atas baku mutu sesuai keputusan Menteri Negara Lingkungan Hidup No.58 tahun 1995, lampiran B, yang akan berlaku pada tahun 2000. Hipotesis yang akan diuji adalah bahwa kualitas limbah cair klinis akan menjadi lebih baik setelah mengalami pengolahan. Uji t terhadap rata-rata kadar limbah cair sebelum dan sesudah pengolahan menunjukkan perbedaan bermakna (p < 0.05) untuk parameter BOD, COD dan suhu, sedangkan untuk TSS, pH, amoniak, fosfat, perkiraan jumlah kuman E.coli dan Koliform tinja secara statistik tidak berbeda bermakna.
Manajemen pengolahan limbah cair klinis rumah sakit Sint Carolus secara umum baik, meliputi: tenaganya cukup memadai dalam jumlah dan kualitas termasuk adanya pengaturan kerja bergilir, biaya operasional / pemeliharaan relatif rendah, pengawasan dengan melakukan pemeriksaan kualitas limbah cairnya 3 bulan sekali dengan hasilnya baik dan di bawah baku mutu, serta efisiensi unit pengolahan limbah cair dalam pengambilan bahan pencemar mencapai 80s - 90% untuk kadar BOD, COD dan TSS. Di samping biaya investasi yang cukup mahal, unit tersebut masih belum mampu mengurangi kandungan bakteriologik sesuai baku mutu lingkungan yang akan diberlakukan pada tahun 2000, sehingga perlu modifikasi dalam sistem FBK-Bioreaktor atau dilakukan pengolahan pendahuluan dengan bahan koagulan.

ABSTRACT
Any hospital produces many medical wastes or clinic disposals that contain infectious, toxic or radioactive substances which are dangerous for public health and environment sanitation.
This research was aimed to learn the management of waste water treatment in the Sint Carolus Hospital. The specific objective is to describe treatment of waste water clinic and to identify the quality of waste water by comparing pre and post treatment using environmental quality standard.
The results indicated that analysis of waste water clinic, compared with standard quality in term of BOD, pH, temperature, TSS, amoniac, (include heavy metal, hazardous agents and fat), still below the standard value. But for phosphate, MPN E. colif100 ml and Koliform fecal (?10.000/100ml) were over the standard value, according to the Minister Environment decree, N0.58 / 1995, supplement B. This decree will become enforced in the year of 2000.
The hypotheses was that the quality of waste water would be significantly lower after treatment. The T test result indicated significance differences (p <0,05) for BOD, COD, and temperature values, but not for TSS, pH, amoniac, phosphate, MPN E.coli and Koliform fecal values.
In general, the management of waste water clinics treatment in Sint Carolus Hospital was good. The personnel were sufficient quantitatively and qualitatively. The cost of operation/maintenance was relative low. Controlling was done by examining the physical and chemical characteristic of waste water every 3 month, and all result were good, except for phosphate. The treatment efficiently removed 80%-90% for BOD, COD and TSS values. However, investment cost was very expensive, in addition that unit cannot reduce the bakteriologic aspect well, according to environ mental quality standard that will become effective on the year of 2000. Therefore it is necessary to modify FBKBioreactor system or to do preliminary treatment using coagulant substances.
"
Depok: Universitas Indonesia, 1996
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Siregar, Tagor Marsillam
"Kegiatan Pelayanan Kesehatan yang dilakukan oleh rumah sakit selain memberikan dampak positif juga berpotensi menimbulkan dampak negatif yang disebabkan oleh pembuangan limbah, berupa limbah padat, cair, dan gas.
Limbah cair rumah sakit merupakan salah satu sumber pencemaran yang sangat potensial, karena mengandung senyawa organik yang cukup tinggi dan mengandung senyawa-senyawa kimia lain serta mikroorganisme patogen yang dapat menyebabkan timbulnya penyakit terhadap masyarakat di sekitarnya.
Upaya pengelolaan limbah rumah sakit khususnya limbah cair, merupakan salah satu upaya penyehatan lingkungan rumah sakit dan lingkungan sekitarnya. Namun kenyataannya belum semua rumah sakit dapat melaksanakannya secara optimal.
Berbagai penelitian menunjukkan belum banyak rumah sakit yang mengelola limbah cairnya dengan baik, bahkan tidak satu pun rumah sakit yang berada di wilayah DKl Jakarta dapat memenuhi persyaratan Baku Mutu Limbah Cair.
Berdasarkan kenyataan tersebut kebutuhan fasilitas pengolahan limbah cair rumah sakit harus diperhatikan. Oleh karena itu, diperlukan suatu alternatif penyelesaian untuk memperbaiki kualitas efluen limbah cair rumah sakit tersebut.
Penelitian Pengaruh Penambahan inokulum Pada Pengolahan Limbah Cair Rumah Sakit dilakukan sebagai alternatif pengolahan limbah cair rumah sakit. Dengan penambahan inokulum, berarti ada penambahan sejumlah mikroorganisme ke dalam sistem pengolahan limbah cair rumah sakit yang bertujuan untuk meningkatkan efektivitas pengolahannya.
Tujuan penelitian ini adalah untuk mengetahui pengaruh penambahan inokulum M-Bio terhadap tingkat penurunan konsentrasi parameter BOD, COD, Padatan Tersuspensi, Fosfat, Nitrat, Nitrit, dan E. coli dan untuk membandingkan tingkat penurunan konsentrasi setiap parameter dengan waktu tinggal dalam reaktor selama 2, 4, 6, 8, 16, 24, 36, 48, 72, dan 96 jam, sehingga diketahui tingkat penurunan tertinggi.
Hipotesis yang diajukan dalam penelitian ini adalah:
1. Penambahan M-Bio akan mengakibatkan penurunan konsentrasi BOD, COD, Padatan Tersuspensi, Fosfat, Nitrat, Nitrit, dan E. coli pada pengolahan limbah cair rumah sakit di dalam reaktor fixed-film aerobic.
2. Penambahan M-Bio akan meningkatkan penurunan konsentrasi parameter BOD, COD, Padatan Tersuspensi, Fosfat, Nitrat, Nitrit, dan E. coli pada limbah cair rumah sakit, dengan meningkatnya waktu tinggal limbah cair tersebut dalam reaktor fixed-film aerobic.
Penelitian eksperimental dilakukan dalam skala laboratorium dengan rancangan penelitian acak lengkap one group pretest-postest design, yang dilakukan dengan waktu pengamatan 0, 2, 4, 6, 8, 16, 24, 36, 48, 72, dan 96 jam. Sampel limbah cair rumah sakit diambil dari inlet gabungan instalasi pengolahan air limbah (IPAL) RSUD Pasar Rebo, Jakarta Timur. Parameter utama yang diukur adalah BOD, COD, Padatan Tersuspensi, Fosfat, Nitrat, Nitrit, dan E. coli. Data hasil pengamatan dianalisis menggunakan uji statistik t-test dan korelasi regresi.
Berdasarkan hasil dan pembahasan data yang diperoleh dari penelitian ini, maka kesimpulan yang diperoleh adalah:
1. Penggunaan M-Bio pada penelitian ini mengakibatkan penurunan konsentrasi parameter BOD, COD, Padatan Tersuspensi, Fosfat, Nitrat, Nitrit, dan E. coli secara signifikan (p<0,005).
2. Penggunaan M-Bio memberikan persentase penurunan terbesar untuk konsentrasi parameter BOD sebesar 54,57% pada waktu tinggal 8 jam, konsentrasi COD sebesar 60,24% pada waktu tinggal 24 jam, konsentrasi padatan tersuspensi sebesar 51,79% pada waktu tinggal 8 jam, konsentrasi nitrat sebesar 39.81% pada waktu tinggal 8 jam, konsentrasi nitrit sebesar 49,81% pada waktu tinggal 8 jam, konsentrasi fosfat sebesar 52,15% pada waktu tinggal 8 jam, dan konsentrasi E. coli sebesar 45,56% pada waktu tinggal 8 jam.
3. Penggunaan M-Bio pada penelitian ini akan meningkatkan penurunan konsentrasi parameter BOD, COD, Padatan Tersuspensi, Fosfat, Nitrat, Nitrit, dan E. coli secara signifikan (p<0,005), sejalan dengan peningkatan waktu tinggal limbah cair tersebut dalam reaktor fixed-film aerobic.

Inoculums Influence on Hospital Wastewater Treatment (A case study on Wastewater Treatment of Pasar Rebo General Hospital, Jakarta with M-Bio on Fixed-Film Aerobic Reactor)
Medical services by hospital have negative impact due to waste produced such as solid material, liquid and gas, besides positive impact.
Hospital wastewater is one of the potential pollutants related to organic compound, other chemical compounds, and pathogenic microorganism content that cause disease on community.
Waste management in hospital especially wastewater treatment becomes hospital sanitary and environment. In fact, only several hospitals do it better.
According to the research, there are not many hospital have a management on wastewater. Even in Jakarta, there is no hospital who reaches the effluent standard in wastewater quality.
Based on this condition, hospital wastewater treatment facility should be attended. Thus, the solving alternative is needed to make hospital wastewater effluent quality better.
The study about inoculums influence on hospital wastewater treatment was conducted as an alternative for hospital wastewater treatment. A number of microorganisms were added into hospital wastewater treatment system in order to increase with effectively by inoculums addition.
The aim of this study is to understand the inoculums influence of M-Bio on removal concentration of parameters BOD, COD, Suspended solids, NO3-, N02-, P043-, and E. coli and to compare the removal concentration of parameters with detention time in the reactor for 2, 4, 6, 8, 16, 24, 36, 48, 72, and 96 hours, finally the highest ratio of decreasing parameters will found.
The hypotheses of this study are:
1. An addition of M-Bio will decrease the concentration of parameters BOD, COD, Suspended solids, N03-, N02-, PO43-, and E. coli on hospital wastewater treatment using fixed-film aerobic reactor.
2. An addition of M-Bio will decrease the concentration of parameters BOD, COD, Suspended solids, NO3-, N02-, PO43-, and E. coli on hospital wastewater due to increasing detention time of hospital wastewater in fixed-film aerobic reactor.
An experimental study with one group pretest-posttest used completed random design and was conducted in the Environmental Laboratory of Engineering, University of Indonesia. The experiment was conducted with the observation time for 0, 2, 4, 6, 8, 16, 24, 36, 48, 72, and 96 hours. Hospital wastewater samples were taken from the inlet of sewage treatment Plant (IPAL) on Pasar Rebo General Hospital, Jakarta. The main parameters that measured were BOD, COD, Suspended solids, N03-, N02-, PO43-, and E. coli. All data were analyzed using analysis of t-test and regression correlation.
The conclusions of this study are:
1. M-Bio decrease significant the concentration of parameters BOD, COD, Suspended solids. N03-, N02-, PO43-, and E. coli (p < 0.005).
2. The highest removal concentration of BOD in 54, 57% with detention time 8 hours, COD = 60, 24%; 24 hours, Suspended solids = 51, 79%; 8 hours, N03-= 39, 81%; 8 hours, N02- = 49, 81%; 8 hours, P043- = 52, 15%; 8 hours, and E. coli = 45, 56%; 8 hours.
3. M-Bio increase significant the removal concentration of parameters BOD, COD, Suspended solids, NO3, N02 , P043-, and E. coli on hospital wastewater (p < 0.005) due to the increasing detention time of hospital wastewater in the fixed-film aerobic reactor."
Depok: Program Pascasarjana Universitas Indonesia, 2001
T7774
UI - Tesis Membership  Universitas Indonesia Library
cover
Danar Permana
"Penelitian ini memanfaatkan kemampuan zeolit alam Lampung sebagai bonding agent (bahan pengikat) melalui proses flotasi untuk mengangkat limbah amonia ke permukaan. Pada penelitian ini ditambahkan beberapa bahan-bahan kimia berupa koagulan Polyaluminium chloride (PAC) dan surfaktan Sodium Lauril Sulfat (SLS) . Penelitian ini dilakukan dengan variasi pH 6, 10 dan 11, dosis PAC (0 g/L dan 0,13 g/L), dosis SLS (0,2 g/L, 0,4 g/L, 0,6 g/L, dan 0,8 g/L). Berdasarkan hasil penelitian, persentase pemisahan amonia tertinggi adalah 95,33 % pada kondisi pH 6, dosis SLS 0,8 g/L dan dosis PAC 0,13 g/L. Pengaruh penambahan SLS terbukti dapat meningkatkan persentase pemisahan yang dihasilkan.

This research uses Zeolit Alam Lampung as a bonding agent through flotation process to lift ammonia to the surface. Surfactant Sodium Lauril Sulfat (SLS) and coagulant Polyaluminium chloride (PAC) was added to this process. Flotation process was variated in pH (6, 10 and 11), PAC (0 g/L; 0,13 g/L) and SLS (0,2 g/L; 0,4 g/L; 0,6 g/L, and 0,8 g/L). Based on this research, the highest ammonia separation presentation is 95,33%. This result was reached in pH 6 when SLS concentration 0,8 g/L and PAC concentration 0,13 g/L. The effect of addition SLS has made the ammonia separation presentation increased."
Depok: Fakultas Teknik Universitas Indonesia, 2008
S52227
UI - Skripsi Open  Universitas Indonesia Library
cover
<<   1 2 3 4 5 6 7 8 9 10   >>