Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 110282 dokumen yang sesuai dengan query
cover
Simamora, Baringin
Depok: Fakultas Teknik Universitas Indonesia, 1991
S34351
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1990
S34337
UI - Skripsi Membership  Universitas Indonesia Library
cover
Unus Suriawiria
Bandung: Alumni, 2003
579 UNU m
Buku Teks  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1991
S34363
UI - Skripsi Membership  Universitas Indonesia Library
cover
Yudi Hadisaputra
"ABSTRAK
Air bersih merupakan salah satu kebutuhan mendasar bagi manusia. Saat ini, IPA Pulo Gadung dapat mengolah debit air sebesar 4.200 L/detik. Tujuan dari penelitian ini adalah 1 mengevaluasi desain unit pengolahan terhadap kriteria desain, 2 mengevaluasi kualitas air baku dan air bersih, 3 mengevaluasi efisiensi kinerja unit pengolahan, serta 4 menentukan debit pengoptimalan. Untuk mengetahui tingkat kinerja kualitas IPA Pulo Gadung, maka dilakukan pengujian kualitas air, yaitu kekeruhan SNI 06-6989.25-2005, E. Coli Most Probable Number, zat organik SNI 06-6989.22-2004, dan COD Standard Methods: 5220 D serta jar test. Selain itu, untuk mengetahui tingkat kinerja kuantitas, maka dilakukan evaluasi desain terhadap kriteria desain dan rancangan pengoptimalan kapasitas. Berdasarkan evaluasi desain, banyak aspek yang tidak memenuhi kriteria desain. Berdasarkan parameter COD, pada PP No. 82 Tahun 2001, air baku yang digunakan IPA Pulo Gadung tergolong dalam air Kelas IV air untuk mengairi pertanaman. Air bersih hasil pengolahan, berdasarkan Permenkes No. 492 Tahun 2010, memiliki beberapa parameter kualitas air yang tidak memenuhi standar tersebut. Unit mixing well efektif dalam menghilangkan E. Coli 47,7, sedimentasi dan filtrasi menghilangkan kekeruhan 93,05 dan 97,32, serta reservoir menghilangkan E. Coli 73,04. Secara keseluruhan, IPA Pulo Gadung dapat menghilangkan kekeruhan sebesar 99,83, E. Coli sebesar 96,39, organik sebesar 40,16, dan COD sebesar 16,57. Dari uji jar test, koagulan optimal untuk air IPA Pulo Gadung adalah koagulan PAC 20 ppm. Dengan mengacu pada kriteria desain, debit optimal masing-masing unit adalah intake sebesar 9,33 m3/detik, saringan kasar 1,09 m3/detik, saringan halus 13,44 m3/detik, grit chamber 4,86 m3/detik, pompa 7,65 m3/detik, mixing well 18,9 m3/detik, flokulasi 3,09 m3/detik, sedimentasi 5,83 m3/detik, filtrasi 12 m3/detik, dan reservoir 16,57 m3/detik. Kesimpulannya adalah kinerja pengelolaan kualitas air IPA Pulo Gadung sudah baik dan kapasitasnya masih dapat ditingkatkan.

ABSTRACT
Clean water is one of the basic needs for human beings. Currently, IPA Pulo Gadung can treat 4,200 L sec of raw water. The objectives of this study are 1 to evaluate the design of the processing unit based on design criteria, 2 to evaluate the quality of raw and clean water, 3 to evaluate the efficiency of processing unit removal rate, and 4 to determine the flowrate optimization. To determine the removal rate of IPA Pulo Gadung, the water qualities to be tested are turbidity SNI 06 6989.25 2005, E. Coli Most Probable Number, organic matter SNI 06 6989.22 2004, and COD Standard Methods 5220 D and jar test. To determine the level of quantity performance, the unit design was evaluated to design criteria and determined the flowrate optimization. Based on design evaluation, many aspects do not meet the design criteria. Based on COD parameters, in PP No. 82 of 2001, raw water used by IPA Pulo Gadung classified in Class IV water water to irrigate crop. Clean water produced, based on Permenkes No. 492 of 2010, has several water qualities that do not meet the standard. The mixing well unit is effective in removing E. Coli 47.7, sedimentation and filtration removing turbidity 93.05 and 97.32, and reservoir removing E. Coli 73.04. Overall, IPA Pulo Gadung can eliminate with the removal rate of turbidity 99.83, E. Coli 96.39, organic matter 40.16, and COD 16.57. From jar test, optimal coagulant for IPA Pulo Gadung is PAC 20 ppm. With reference to the design criteria, the optimal flowrate of each unit is intake 9.33 m3 sec, coarse screen 1,09 m3 sec, fine screen 13,44 m3 sec, grit chamber 4.86 m3 sec, pumping system 7.65 m3 sec, mixing well 18.9 m3 sec, flocculation 3,09 m3 sec, sedimentation 5.83 m3 sec, filtration 12 m3 sec, and reservoir 16.57 m3 sec. The conclusion is that the performance of water quality removal rate of IPA Pulo Gadung is good and the capacity can still be improved."
2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Novan Dwi Novembry
"Air limbah domestik merupakan sumber pencemaran air yang berdampak pada penurunan kualitas air bersih. Sumber pencemaran di perkotaan juga disebabkan oleh bocornya air limbah dari tangki septik konvensional dimana desain tangki septik tidak memenuhi standar teknis. Penelitian ini bertujuan untuk mengetahui efisiensi pengolahan air limbah domestik menggunakan dua jenis tangki septik dengan filter up-flow dan downflow untuk mereduksi polutan organik. Sampel air limbah diambil dari Instalasi Pengolahan Air Limbah (IPAL) Komunal Janti di Malang. Tangki septik skala laboratorium yang digunakan dalam penelitian ini memiliki dimensi 54 cm x 22 cm x 37 cm, terbuat dari kaca setebal 5 mm. Laju aliran air limbah yang dimasukkan ke dalam tangki septik skala lab adalah 20 liter/hari dengan waktu detensi 2 hari. Model tangki septik terdiri dari tiga kompartemen dengan ketebalan media filter 15 cm untuk setiap jenisnya. Hasil penelitian menunjukkan bahwa efisiensi penyisihan polutan pada tangki septik filter upflow adalah 55,84% BOD, 58,64% COD, 87,84% TSS, 75,07% NH4+, dan 57,19% Total Coliform. Sedangkan pada tangki septik filter downflow, efisiensi penyisihan parameter yang sama adalah65,26%, 66,90%, 90,34%, 79,52%, dan 57,54%. Nilai removal tersebut menunjukkan bahwa pengolahan menggunakan tangki septik filter downflow menghasilkan efisiensi yang lebih tinggi daripada tangki septik filter up-flow."
Bandung: Kementerian Pekerjaan Umum dan Perumahan Rakyat, 2022
728 JUPKIM 17:2 (2022)
Artikel Jurnal  Universitas Indonesia Library
cover
Fakultas Teknik Universitas Indonesia, 1995
S34489
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dewi Mulianingsih
Depok: Fakultas Ekonomi dan Bisnis Universitas Indonesia, 1983
S17064
UI - Skripsi Membership  Universitas Indonesia Library
cover
Lunn, Hugh Duncan
Queensland: University of Queendsland Press, 1978
320.9943 Lun j
Buku Teks  Universitas Indonesia Library
cover
Donny Tanama
Depok: Fakultas Teknik Universitas Indonesia, 2005
S35780
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>