Alimuddin
"ABSTRACT
An Automated quick check phantom for quality assurance and daily stability control for linac electron beams has been design and fabricated. The device has 5 circle selectable carousel system with different thicknesses of alumunium for dmax and d50 corresponding to 6, 9, 12, 16, and 20 MeV electron beams. The values of dmax and d50 were determined by a wedge-film and alumunium phantom PDD curve. The Measurement on dmax was called Maximum Evaluation Method (MEM), and the respective measurement on d50 is referred as Fifty persen Evaluation Method (FEM) and the ratio between the two measurement were then used for Ratio Evaluation Method (REM). The whole system then is used to measure constancy of Linac Varian 2100c within a period of 1 months. The measurement proved the reability of the design and implementation of the automated system.

ABSTRAK
Telah dibuat fantom quickcheck uji jaminan kualitas dan stabilitas harian berkas elektron pesawat linac. Fantom tersebut memiliki 5 ketebalan yang berbeda yang dapat digerakkan berputar secara otomatis dengan sistem carousel untuk dmax dan d50 berkas elektron 6, 9, 12, 16, 20 MeV. Nilai-nilai dmax dan d50 diperoleh dengan menggunakan wedge almunium menggunakan film dan kurva PDD almunium. Dengan mengacu pada empat metoda pengolahan data, yaitu Metoda Evaluasi maksimum (MEM), Metoda Evaluasi Limapuluh (MEL), Metoda Evaluasi Rasio (MER), juga sebagai pembanding Metoda Evaluasi Akrilik (MEA). Selanjutnya alat tersebut diuji reabilitasnya dan dilakukan pengambilan data harian selama 1 bulan untuk melihat kesesuaian, kestabilan, dan ketangguhannya terhadap perubahan yang terjadi pada pesawat linac varian 2100c. Pengukuran yang dilakukan menunjukkan reabilitas pembuatan dan implementasi dari sistem automatisasi tersebut."
2007
T20995
UI - Tesis Membership  Universitas Indonesia Library
cover
Ridwan
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2001
S28650
UI - Skripsi Membership  Universitas Indonesia Library
cover
Apriyansah Putera
"Telah dilakukan pengukuran kestabilan keluaran dan energi berkas elektron pada energi 9, 12, 16, dan 20 MeV hasil Linac Varian 210°C di RS. Persahabatan dalam periode pengamatan hampir kontinyu 1,5 bulan. Metode eksperimen dilakukan dengan menggunakan aplikator 10 x 10 cm2, SSD 100 cm dan menggunakan detektor bilik ionisasi Farmer yang diletakkan dalam fantom akrilik. Pengukuran output dilaksanakan pada kedalaman 2,5 cm sedangkan pengukuran energi didasarkan pada rasio output pada 2,5 cm terhadap output pada 3,5 cm. Hasil pengukuran menunjukan output dan energi Linac cukup stabil sesuai batas toleransi ± 2 %. Pengukuran output pada energi 6 MeV tidak dapat dilakukan pengukuran karena telah melampaui jangkauan dari berkas elektron.

Stability of output and energies for Linac Varian 210°C electron beams for energies 9, 12, 16, and 20 MeV at Persahabatan hospital within the period of 1,5 months were measured. Experiments were done at SSD 100 cm using applicator size 10 x 10 cm2 and Farmer ionization chamber in PMMA phantom. Output was measured at 2,5 cm depth while energy was determined as the ratio of outputs at 2,5 and 3,5 cm depths respectfully. Results showed outputs and energies of Linac is within acceptable ± 2% variabilities. Measurements at 6 MeV energy was not possible due to phantom limitation."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2007
S28899
UI - Skripsi Membership  Universitas Indonesia Library
cover
Selfira Salsabilla
"ABSTRACT
Currently airplane passengers in Indonesia have a wide selection of airplane ticket purchase applications (PTP Application). The existence of various PTP applications in Indonesia makes it easy for users to stop using the PTP application and move to another PTP application. This study aims to identify the factors that influence the customer's intention to continue the use of PTP Application. This study uses the expectation confirmation model (ECM) by adding a trust variable. 203 respondents participated in this study. The model was tested using SmartPLS 2.0. The results of the study show that satisfaction is an important variable that influences the customer's intention to continue using PTP applications. In addition, trust and perceived usefulness have a significant positive effect on the intention to continue using PTP applications. Confirmation and usefulness perceptions have a significant positive effect on satisfaction and trust. This study discusses results of research both in relation to the theoretical and practical context."
Jakarta: Fakultas Ekonomis dan Bisnis UIN Syarif Hidayatullah, 2019
650 ESENSI 9:1 (2019)
Artikel Jurnal  Universitas Indonesia Library
cover
Fiqron
"Telah dilakukan pengukuran faktor keluaran (OF) berkas sinar-X 6 MV dan 10 MV untuk lapangan bujur sangkar dan persegi panjang produksi linac varian 2100C. Ukuran lapangan yang digunakan berkisar dari 4x4 cm2 sampai 30x30 cm2 . Pengukuran dilakukan pada kedalaman efektif pengukuran 5,2 cm dan 10,2 cm dengan SSD 100 cm. Pada lapangan persegi panjang nilai OF didapatkan dengan metode pengukuran langsung dan kalkulasi dengan metode Sterlling. Hasil pengukuran menunjukkan hasil OF keduanya memiliki perbedaan yang sangat kecil untuk kedua berkas energi sinar-X pada masing-masing bentuk lapangan. Nilai OF mengalami kenaikan seiring meningkatnya ukuran lapangan yang digunakan. Penentuan nilai OF dengan menggunakan metode Sterllling dan pengukuran langsung pada lapangan persegi panjang juga tidak berbeda secara signifikan. Kata kunci : faktor keluaran, lapangan bujur sangkar, lapangan persegi panjang, sinar-X 6 MV dan 10 MV.

The measurement has been performed to know the output factors (OF) of 6 MV and 10 MV X-ray beams for square and rectangular fields. The field size used for the measurement range between from 4x4 cm2 to 30x30 cm2. The measurement were done at effective depths of 5,2 cm and 10,2 cm with SSD 100 cm. On the rectangular field, OF was obtained by direct measurement method and calculated by Sterlling method. The results of measurement showed that both OF’s results have very small differences for both energies on each field shape. The OF’s values increase along with the field size increase. The OF values determined by using calculated Sterlling method and direct measurement on rectangular field do not show significant differences."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2007
S28877
UI - Skripsi Membership  Universitas Indonesia Library
cover
Erwinsyah Satria
"Telah dibuat suatu prototipe instrumen untuk pengukuran berat dengan menggunakan sensor LVDT (LVDT weigh cell). Rangkaian pembangkit gelombang AC untuk LVDT menggunakan osilator Wien-Bridge yang disambungkan dengan penguat arus. Rangkaian pengkondisi sinyal dibuat untuk menyearahkan tegangan AC, menapis, dan menguatkan sinyal keluaran LVDT. Untuk sistem akuisisi digunakan Data Acquisition (DAQ) card NI PCI-6024E yang dihubungkan ke Personal Computer (PC). Bahasa pemrograman LabVIEW digunakan untuk membuat tampilan pada PC berupa panel depan dengan indikator dan kontrol yang menampilkan data hasil pengukuran berat.
Beberapa parameter uji pada penelitian ini adalah osilator, LVDT, pegas, pengkondisi sinyal, DAQ, pengendali beban, dan histeresis. Setelah melakukan pengujian diketahui bahwa jangkau ukur dipengaruhi oleh defleksi pegas. Prototipe LVDT weigh cell yang dibuat pada penelitian ini dicoba untuk jangkauan ukur sampai dengan 1.000 gram dengan resolusi 10 gram."
Jakarta: Universitas Indonesia, 2006
T20842
UI - Tesis Membership  Universitas Indonesia Library
cover
Choirul Anam
"Telah dilakukan studi kontaminasi elektron pada berkas foton 6MV pesawat Linac Elekta SL15 menggunakan simulasi Monte Carlo. Pemodelan kepala Linac menggunakan program BEAMnrc, analisis phase space file menggunakan program BEAMDP dan perhitungan dosis radiasi dalam phantom air menggunakan program DOSXYZnrc. Dalam simulasi ini, energi awal elektron yang optimum adalah 6.3 MeV, dan intensitas radialnya memiliki FWHM 1.0 mm karena diketahui paling sesuai dengan pengukuran. Dalam simulasi diperoleh, semakin besar ukuran lapangan radiasi, dosis kontaminasi elektron mengalami kenaikan. Pada kedalaman 1.0 mm dan ukuran lapangan radiasi 5x5, 10x10, 20x20, 30x30, dan 40x40 cm2, dosis kontaminasi elektron secara berurutan sebesar 3.71, 5.19, 14.39, 18.97 dan 20.89%. Semakin ke dalam, dosis kontaminasi elektron semakin berkurang dan pada kedalaman 15 mm, kontribusinya hanya sekitar 1%. Kontaminasi elektron terutama dihasilkan oleh udara antara Linac dan fantom, mirror dan flattening filter. Bagian lain dari kepala Linac, hanya memberikan kontribusi yang kecil.

Study on electron contamination for 6 MV photon beams from Elekta SL15 linac by using Monte Carlo simulation has been done. The linear accelerator head was simulated by BEAMnrc code and the phase-space file then was analyzed by BEAMDP, while the absorbed dose in water phantom was calculated using DOSXYZnrc code. In this simulation, the optimal initial electron beam parameters were 6.3 MeV in energy and 1.0 mm in FWHM (full width at half maximum) on the radial intensity distribution. They were found to be in good agreement with the measured data. It was obtained in this reasearch that the electron contamination increases as the field size increases. At 1.0 mm in depth and the field size 5x5, 10x10, 20x20, 30x30, and 40x40 cm2, the dose from electron cotamination respectively 3.71, 5.19, 14.39, 18.97 and 20.89%. The electron contamination decreases with depth. At 15 mm in depth, the contribution of electron contamination is about 1%. The electron contamination is mainly produced from air volume between the linac head and water phantom, mirror and flattening filter. The other parts of linac head only give small contribution."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
T29121
UI - Tesis Open  Universitas Indonesia Library
cover
JPP 27:1(2004)
Artikel Jurnal  Universitas Indonesia Library
cover
Dwi Bondan Panular
"ABSTRAK
Tesis ini membahas tentang perbedaan hasil pengukuran keluaran linac
precise system di RSPAD Gatot Soebroto menggunakan detektor matriks PTW
dan fantom air, untuk sinar-x pengukuran dilakukan pada lapangan 10 x 10 cm2
dengan SSD 100 cm sedangkan untuk elektron menggunakan aplikator 10 x 10
cm2 dengan SSD 95 cm, dosis yang diberikan 1 Gray (100 MU) pada kedalaman
maksimum. PDD untuk sinar-x dan elektron yang dihasilkan dari pengukuran
detektor matriks memiliki rentang yang lebih pendek pada daerah kedalaman
maksimum dibandingkan dengan hasil pengukuran menggunakan fantom air,
dengan rentang perbedaan 4 mm ? 5 mm untuk sinar x dan 3 mm ? 6 mm untuk
elektron. Sedangkan profil dosis untuk berkas sinar-x antara detektor matriks
dengan fantom air memiliki kesesuaian pada daerah lapangan penyinaran dengan
perbedaan kurang dari 2 %. Untuk berkas elektron terjadi perbedaan yang
signifikan dengan bertambahnya kedalaman, sehingga dapat disimpulkan bahwa
detektor matriks dapat digunakan untuk verifikasi penyinaran pada daerah target
volume penyinaran (Gross Tumour Volume/GTV) tetapi kurang baik untuk daerah
organ sekitarnya (Organ at Risk/OAR). Detektor matriks lebih baik apabila
digunakan untuk sinar-x, tetapi kurang baik digunakan untuk elektron.

ABSTRACT
This thesis discusses about output differences of Elekta Precise linac
treatment system on Gatot Subroto Army Hospital between the use of matrix
detector and water phantom, for x-ray measurement performed on 10 x 10 cm2
field size with a SSD 100 cm, as well as electron measurement using the
applicator 10 x 10 cm2 with SSD 95 cm, both on the given dose of 1 Gray
(100 MU) in the maximum depth. PDD for x-rays and electrons from the
measurement of the matrix detector has shorter range in comparison to the
maximum depth of measurement results with the water phantom. The range of
difference is found to be 4 mm - 5 mm for x-rays and 3 mm - 6 mm for the
electrons. Dose profile for x-ray measurement using the matrix detector is having
compatibility with water phantom measurement at the irradiation field, with the
difference found to be less than 2%. For the electron beam, significant difference
occurs with increasing depth, leading to the conclusion that the matrix detector
can be used to verify radiation on the Gross Tumour Volume (GTV), while being
not good enough for the Organ at Risk (OAR). The matrix detector is better used
for x-rays measurement, with relatively poor compatibility for electron
measurement."
2012
T31257
UI - Tesis Open  Universitas Indonesia Library
cover
Hilda Lestari
"Produk bancassurance merupakan produk perbankan yang terdiri dari produk simpanan/investasi yang digabung dengan produk asuransi jiwa. Salah satu bentuknya yaitu berupa deposito yang dikemas dengan asuransi jiwa didalamnya. Dalam perkembangannya, produk bancassurance yang demikian dapat dijadikan sebagai jaminan kredit perbankan. Penelitian ini bertujuan untuk mengetahui bagaimana karakteristik pemberian kredit dengan jaminan produk bancassurance dan bagaimana dengan hak bank sebagai kreditor apabila terjadi wanprestasi dalam pemberian kredit tersebut. Hasil penelitian menjelaskan bahwa karakteristik pemberian kredit semacam ini terletak pada perjanjian pengikatan jaminannya, dimana ada 2 (dua) jaminan yang diikat secara bersamaan dalam 1 (satu) perjanjian kredit, yaitu pengikatan jaminan deposito dan hak klaim atas polis asuransi jiwa. Adanya kedua jaminan tersebut menjamin bahwa debitor dapat menjaga kelangsungan pelunasan pembayarannya. Apabila debitor wanprestasi, maka bank berhak untuk dapat langsung mencairkan kedua jaminan tersebut tanpa harus melakukan pelelangan di muka umum. Untuk itu, Penulis menyarankan agar ketentuan-ketentuan tentang produk bancassurance dituangkan dalam suatu wadah peraturan tersendiri agar lebih komprehensif dan perlu dilakukan penyempurnaan atas ketentuan-ketentuan tentang hukum jaminan, terutama mengenai jaminan gadai dan fidusia.

Bancassurance product is one of banking products consisting of deposit/investment combined with life assurance. One of the models is a deposit in which the life insurance is incorporated. The bancassurance product, in its progress, may be used as banking security credit. The objective of this research is to identify how is characteristic of credit grant with secured bancassurance and how the bank?s right as creditor, in the case of default, on such the credit provision. The result shows that the characteristic of this credit grant exists in its security agreement, in which there are 2 (two) securities bound together within 1 (one) credit agreement namely deposit agreement and right to claim life insurance premium. The existences of both securities assure that the debtor may maintain the repayment process. In the case of default by the debtor, the bank has the right to disburse the securities directly without public auction. For such reason, the writer suggests that the provisions on bancassurance products is set forth in one single instrument so as to be more comprehensive and provisions on security of law especially on mortgage and fiduciary collateral.
"
Depok: Fakultas Hukum Universitas Indonesia, 2014
T41665
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>