Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 80468 dokumen yang sesuai dengan query
cover
Rum Sapundani
"Telah dilakukan simulasi Monte Carlo pada berkas foton 6 MV Linac Elekta di dalam fantom air dan PMMA. Dalam simulasi digunakan code BEAMnrc berbasis 2 processor sistem Linux. File phase-space yang diperoleh menjadi input bagi code BEAMDP untuk memperoleh informasi karakteristik dan kontaminasi partikel. File yang sama juga menjadi input code DOSXYZnrc untuk menghasilkan PDD. Hasil PDD dibandingkan dengan hasil eksperimen dengan deviasi sangat kecil.

A Monte Carlo simulation on a Linac Elekta 6 MV photon beam has been performed using BEAMnrc code running on Linux-based 2 processor system. A phase- space files obtained were input to a BEAMDP code subsequently to produce information on particles characteristics and contamination. The same files were also input to a DOSXYnrc code to produce PDD in virtual water and PMMA phantoms. PDD results were compared with experimental results with significantly small deviation."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2007
T21093
UI - Tesis Membership  Universitas Indonesia Library
cover
Harykin Muliono
"Telah dilakukan penentuan karakteristik sumber beta 90Sr/90Y dengan menggunakan simulasi Monte Carlo BEAMnrc yang berbasiskan metode Monte Carlo serta penghitungan BEAMDP dan FLURZnrc terutama fluks dan energi-fluks sebagai fungsi posisi, distribusi energi-fluks, distribusi energi spektral, serta distribusi energi rata-rata. Energi rata-rata radiasi elektron yang dihasilkan berkisar 0,75 MeV dan foton pada 0,15 MeV. Partikel radiasi elektron masih dominan dengan jumlah partikel lebih dari 54% jumlah total partikel radiasi (berdasarkan fluks vs posisi, dan distribusi energi spektral), dan energi-fluks maksimumnya sekitar 1,9x10-5 partikel.MeV (87%). Distribusi energi-fluks menunjukkan nilai maksimum di sekitar 7x10-6 partikel.MeV pada energi 0,96 MeV untuk elektron, dan 3,9x10-6 partikel.MeV pada energi 0,10 MeV untuk foton. Juga diperoleh kepastian ketidakhadiran positron. Besar dosis keluaran (menggunakan DOSXYZ) sumber radiasi di sekitar permukaan sumber adalah 3,6x10-13 Gy dan menurun secara eksponensial ketika menjauhi sumber.

A Monte Carlo study has been done on 90Sr/90Y beta source using BEAMnrc protocol including BEAMDP and FLURZnrc calculation to determine flux and energy-flux as a function of positions, energy-flux and energy spectral distribution, and also average energy. Average electron energy was found to be 0.75 MeV and average photon energy at 0.15 MeV. The domination of electron were shown by more than 54% in number (based on flux vs. position, and energy spectral distribution), and the maximum of energy-flux was about 1.9x10-5 particle.MeV (87%). Energy-flux distribution showed that the maximum value was about 7x10-6 particle.MeV at 0.96 MeV for electron, and 3.9x10-6 particle.MeV at 0.10 MeV for photon. There is a definite absence of positron. Dose around the surface were found using DOSXYZ source to be 3.6x10-13 Gy and it is exponentially decayed at distance."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2007
T21081
UI - Tesis Membership  Universitas Indonesia Library
cover
Choirul Anam
"Telah dilakukan studi kontaminasi elektron pada berkas foton 6MV pesawat Linac Elekta SL15 menggunakan simulasi Monte Carlo. Pemodelan kepala Linac menggunakan program BEAMnrc, analisis phase space file menggunakan program BEAMDP dan perhitungan dosis radiasi dalam phantom air menggunakan program DOSXYZnrc. Dalam simulasi ini, energi awal elektron yang optimum adalah 6.3 MeV, dan intensitas radialnya memiliki FWHM 1.0 mm karena diketahui paling sesuai dengan pengukuran. Dalam simulasi diperoleh, semakin besar ukuran lapangan radiasi, dosis kontaminasi elektron mengalami kenaikan. Pada kedalaman 1.0 mm dan ukuran lapangan radiasi 5x5, 10x10, 20x20, 30x30, dan 40x40 cm2, dosis kontaminasi elektron secara berurutan sebesar 3.71, 5.19, 14.39, 18.97 dan 20.89%. Semakin ke dalam, dosis kontaminasi elektron semakin berkurang dan pada kedalaman 15 mm, kontribusinya hanya sekitar 1%. Kontaminasi elektron terutama dihasilkan oleh udara antara Linac dan fantom, mirror dan flattening filter. Bagian lain dari kepala Linac, hanya memberikan kontribusi yang kecil.

Study on electron contamination for 6 MV photon beams from Elekta SL15 linac by using Monte Carlo simulation has been done. The linear accelerator head was simulated by BEAMnrc code and the phase-space file then was analyzed by BEAMDP, while the absorbed dose in water phantom was calculated using DOSXYZnrc code. In this simulation, the optimal initial electron beam parameters were 6.3 MeV in energy and 1.0 mm in FWHM (full width at half maximum) on the radial intensity distribution. They were found to be in good agreement with the measured data. It was obtained in this reasearch that the electron contamination increases as the field size increases. At 1.0 mm in depth and the field size 5x5, 10x10, 20x20, 30x30, and 40x40 cm2, the dose from electron cotamination respectively 3.71, 5.19, 14.39, 18.97 and 20.89%. The electron contamination decreases with depth. At 15 mm in depth, the contribution of electron contamination is about 1%. The electron contamination is mainly produced from air volume between the linac head and water phantom, mirror and flattening filter. The other parts of linac head only give small contribution."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
T29121
UI - Tesis Open  Universitas Indonesia Library
cover
Abdi Wadud Syafi`i
"Telah dilakukan studi simulasi Monte Carlo untuk perhitungan besaran dosimetri dari berkas sinar X 6 MeV tanpa filter perata yang dihasilkan Linac Elekta SL-15. Pemodelan kepala Linac menggunakan program BEAMnrc, analisis phase space file menggunakan program BEAMDP dan perhitungan dosis radiasi dalam medium air menggunakan program DOSXYZnrc. Parameter awal elektron dalam simulasi ini menggunakan hasil yang sudah diperoleh oleh saudara Anam C. Perhitungan PDD dalam medium air dilakukan dengan variasi ukuran lapangan 5x5, 10x10, 20x20 dan 40x40 cm2 dengan SSD 100 cm. Dosis profil dihitung dengan variasi ukuran lapangan yang sama dengan kedalaman 10 cm.
Hasil perhitungan PDD tanpa filter relatif lebih rendah dibanding dengan PDD dengan filter dan tidak dipengaruhi ukuran lapangan radiasi. Spektrum berkas sinar-X tanpa filter perata mempunyai fraksi komponen energi rendah relatif lebih tinggi dibanding dengan sinar-X dengan filter perata sehingga kurva PDD-nya relatif lebih rendah. Hasil perhitungan dosis profil menunjukan dengan melepaskan filter perata akan meningkatkan fluence dan energi fluence serta laju dosis untuk setiap lapangan radiasi.
Hasil penting lainnya adalah dosis permukaan yang jauh lebih tinggi dibanding dengan sinar X yang ber-filter mencapai 59.42 % untuk lapangan 5x5 cm2 dan 70.13 % untuk lapangan 40x40 cm2 dan dosis yg tinggi pada daerah build-up diakibatkan kontaminasi elektron. Berdasarkan hasil yang didapat penggunaan sinar X tanpa perata akan menurunkan skin sparring effect, sehingga tidak cocok untuk dipakai pada Linac. Namun, masih mungkin digunakan untuk teknik IMRT yang membutuhkan intensitas output yang tinggi.

Study on dosimetric properties for an unflattened 6-MV photon beams of an Elekta SL15 linac was calculated using Monte Carlo simulation has been done. The linear accelerator head was simulated by BEAMnrc code and the phase-space file then was analyzed by BEAMDP, while the absorbed dose in water phantom was calculated using DOSXYZnrc code. Initial parameters of electrons in this simulation using the results already obtained by Anam C. PDD calculations performed in water medium by variation of field size 5x5, 10x10, 20x20 and 40x40 cm2 with SSD 100 cm. Dose profiles calculated with the same field size variation with depth of 10 cm.
PDD calculation results without the filter is relatively lower compared with the PDD with the filter and not influenced by the size of the radiation field. The spectrum of unflattened X-ray beam has a fraction of the low energy component is higher than with flattened X-rays so that the PDD curve is relatively lower. The results of dose calculation shows the release flattening filter will increase the fluence and energy fluence and dose rate for each radiation field.
Another important outcome is that the surface dose is much higher than with flattened X-ray to the field reaches 59.42% and 70.13% of 5x5 cm2 to 40x40 cm2 field and on high doses in the build-up due to contamination of electrons. Based on the results obtained using unflattened X-rays the skin sparring effect will decrease, making it unsuitable for use in the linac. However, it still may be used for IMRT techniques that require high output intensity.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2011
T29797
UI - Tesis Open  Universitas Indonesia Library
cover
Agung Nugroho Oktavianto
"Telah dilakukan pengukuran relatif untuk mengetahui perubahan parameter dosimetri berkas sinar X 6 MV pada sumbu vertikal/sumbu normal terhadap permukaan dengan variasi sudut gantry 0º, 15º, 30º, 45º, dan 60º dari pesawat Linac Electa Precise 5991 milik Rumah Sakit Hasan Sadikin Bandung dengan luas lapangan 10x10 cm2, 15x15cm2 , dan 20x20 cm2. Rekonstruksi TPS dan simulasi Monte Carlo menggunakan parameter yang sama dengan pengukuran.
Hasil penelitian menunjukkan bahwa terjadi perubahan kedalaman maksimum yang dipengaruhi kenaikan luas lapangan dan sudut gantri dengan deviasi terbesar -33,3% pada luas lapangan 20x20 cm2 dan sudut gantri 600 terhadap luas lapangan 10x10 cm2 dan sudut gantri 00. Terjadi titik belok pada sumbu vertikal yang disebabkan karena adanya kemiringan permukaan, yang menurun dengan kenaikan sudut gantri. Hasil rekonstruksi TPS menunjukkan kesesuaian terhadap hasil pengukuran pada titik PDD maksimum, kedalaman 5 cm dan 10 cm, berbeda dengan hasil perhitungan Monte Carlo yang relatif lebih tinggi. Demikian pula untuk titik-titik di luar sumbu vertikal/sumbu normal.
Rekonstruksi TPS mempunyai deviasi < 2%, sedangkan perhitungan Monte Carlo mempunyai deviasi < 2% hanya pada daerah kuadran (+). Pengamatan titik-titik pada sumbu utama berkas hanya dilakukan dengan rekonstruksi TPS karena keterbatasan kemampuan alat, hasil penelitian menunjukkan bahwa PDD pada kedalaman dmax, 5 cm, dan 10 cm pada sumbu utama untuk sudut gantri 150 sampai dengan 600 cenderung menurun untuk ukuran lapangan yang sama demikian juga pada daerah kuadran (+).

Relative meauserement for change of dosimetry parameters X ray beam 6 MV Linac Electa Precise 5991 property of Hasan Sadikin Bandung?s hospital at the vertical central line from surface with incident obliquity 0º, 15º, 30º, 45º, 60º and 10x10 cm2, 15x15cm2, 20x20 cm2 field has been done. As in Reconstruction of TPS and Monte Carlo simuation with the same parameters measurement have been conducted.
The result of the experiment showed the change of maximum depth because of the increase in the filed dan angle of gantri with deviation -33% at the 20x20 cm2 field and 600 angle of gantry to 10x10 cm2 field and 00 angle of gantry . To happened point of to drop at the vertical central line because change sloping field to surface and drop on with increase of angle?s gantry.
The result of reconstruction of TPS to show not different with meaurement at point máximum PDD, 5 cm depth, 10 cm depth, point at off verical line, Monte Carlo calculation is higher. In all oint of reconstruction?s TPS has deviation < 2%, but calculation Monte Carlo just happen at the kuadran (+) area. Observation at the point in the central beam just done with reconstruction of TPS because the equipment capability limitation in the measurement, PDD at the depth of dmax, 5 cm, 10 cm, 150 to 600 angle of gantry in the central beam tilted decrease for the same field and kuadran (+) area too.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
T29077
UI - Tesis Open  Universitas Indonesia Library
cover
Sihombing, Tumpal M.
"
In the capital market, investment is usually utilized as a kind of tool for the investors
against the number one cnemy, the infation. By this way, investment is a better alternative than time deposit and cash instrument which offer less return on investment than capital market instrument. Investment can also be a tool for investors in growing their wealth and preserve it. By staying invested, investor can generate earnings and even more from their existing money or fund as long as the market is in expectation and in favour.
Now the world is entering the era of recession when the trend is bearish and market is not so favorable. Many investors are now experiencing great losses and
suffer in their investment. The investment has become like an enemy instead of a tool
to grow, protect and preserve the wealth of investors. Some investors have stated that
the investment did not making them moncy anymore at this time of recession, some said that better not to invest their money in capital market instead. All of these statements were raised mainly because one thing that investors have usually forgotten, its portfolio risk management. Investment bankings in US were bankrupt and no more. The capital markets in every major country were experiencing great amount of loss and people suffered in their investment. That was because one term that has been abandoned all this time, portfolio risk management.
In bullish trend, that was fine to structure the portfolio of investment in stocks and less in bonds as long as the retumn and risk of the portfolio were also fire with the investors. But when the market changes, the structure should be different in terms of portfolio contents. The investor should reduce the portion or share of stocks (since
these relatively have high volatility) and increase the share of bonds and cash in their
portfolio. That is the thing the investor should do.
Capital market of Indonesia bas also suffered because of this world recession. The JCI as the main index price of BEI (Indonesia Stock Exchange) has shown a great downturn for the past one year. Now is the bearish year of the JCI. Therefore, it is also wise for the rational investors to also consider restructuring their portfolio to become mainly in bonds and cash instead of stocks. The way the investors doing this should be by applying the best method ever conceived called modern portfolio theory
which was founded by Nobel Winner Henry Markowitz.
Risk and Return are just like two sides of one coin. The greater the return, the
greater the potential risk may embodied within the investment. The research in this
thesis will show investor on how to find out the lowest risk of a portfolio investment
by providing them with several structures of portfolio weighting. By this way, investor can compare and make the decision based on risk-return consideration and opportunity cost as well.
"
Jakarta: Fakultas Ekonomi dan Bisnis Universitas Indonesia, 2009
T-pdf
UI - Tesis Open  Universitas Indonesia Library
cover
Nikita Ciamaudi
"Reaksi fotoneutron adalah salah satu reaksi inti yang terjadi pada kepala linac, baik pada linac berkas foton ataupun berkas elektron. Reaksi fotoneutron menghasilkan produk berupa neutron dengan tingkat energi tertentu. Penelitian ini bertujuan untuk mensimulasikan berapa besar dosis neutron yang mungkin diterima oleh pasien radioterapi saat proses radioterapi dengan pesawat linac Varian iX 15 MV lapangan 10 cm × 10 cm. Simulasi pengukuran dilakukan pada posisi isocenter kedalaman 1 cm – 15 cm untuk membentuk kurva PDD. Pengukuran off-axis pada permukaan fantom, 2 cm, 3 cm, dan 15 cm juga dilakukan agar dapat membentuk off-axis profile.
Verifikasi simulasi dilakukan dengan membandingkan data pengukuran berkas foton lapangan 30 cm × 30 cm dengan beam data commissioning (BDC) Varian iX 15 MV Rumah Sakit Siloam MRCCC. Hasil Penelitian menunjukkan nilai dosis posisi isocenter adalah 1,24 × 10-2 Sv Gy-1 pada permukaan fantom, 4,82 × 10-2 Sv Gy-1 pada kedalaman 2 cm, 1,25 × 10-1 Sv Gy-1 pada kedalaman 3 cm, dan 1,89 × 10-6 Sv Gy-1 kedalaman 15 cm. Namun, nilai dosis tertinggi terdapat pada posisi -2 cm kedalaman 2 cm, yaitu 2,05 × 100 Sv Gy-1. Pada posisi isocenter, nilai dosis tertinggi berada pada kedalaman 7 cm dengan nilai 2,70 × 10-1 Sv Gy-1.

Photoneutron reaction is one of the reactions that occur in the linac head, both in the photon and the electron beam. The reaction produces neutrons with a certain energy level. This study aims to simulate how much neutron dose that may be received by radiotherapy patients during the process of radiotherapy with Varian iX 15 MV 10 cm × 10 cm field. Measurement simulation is carried out at an isocenter position depth of 1 cm - 15 cm to create a PDD curve. Off-axis measurements on phantom surfaces, 2 cm, 3 cm, and 15 cm are also carried out to make an off-axis profile.
Verification is done by comparing 30 cm × 30 cm field measurement data with beam data commissioning (BDC) of MRCCC Siloam Hospital’s Varian iX 15 MV linac. The result showed the dose value of the isocenter position is 1,24×10−2 Sv Gy-1 on the phantom surface, 4,82×10−2 Sv Gy-1 at a depth of 2 cm, 1,25×10−1 Sv Gy-1 at a depth of 3 cm, and 1,89×10−6 Sv Gy-1 at a depth of 15 cm. However, the highest dose value is -2 cm in 2 cm depth, which is 2,05 × 100 Sv Gy-1. In the  socenter position, the highest dose value is 2,70×10−1 Sv Gy-1 in 7 cm depth.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Farhan Ali
"Beton dan timbal merupakan material yang biasa digunakan sebagai dinding penahan radiasi. Beton dan timbal memiliki kelebihan dan kekurangannya masing-masing. Beton memiliki harga yang relatif lebih murah namun memerlukan ruang yang besar sedangkan timbal dengan nomor atom yang tinggi memiliki harga yang lebih mahal namun ukuran ruangan dapat diminimalisir. Perhitungan ketebalan dinding penahan radiasi dapat dilakukan dengan menggunakan persamaan Safety Report Series No. 47 dengan nilai pembatas dosis sesuai dengan Perka Bapeten no 3 tahun 2013 lalu dilakukan pemodelan menggunakan Monte Carlo EGSnrc untuk memastikan nilai dosis yang dihasilkan tidak melebihi pembatas dosis yang ditetapkan Bapeten. Pemodelan dengan menggunakan Monte Carlo umum digunakan ketika pengukuran secara langsung tidak memungkinkan. Hasil simulasi Monte Carlo juga mampu merepresentasikan kondisi yang sesungguhnya dengan memasukan berbagai parameter seperti memodelkan linac, memodelkan material yang digunakan, memodelkan dinding penahan radiasi, hingga melakukan kalibrasi linac sehingga didapatkan nilai dosis yang dapat dibandingkan dengan nilai dosis referensi yang digunakan. Pada penelitian dilakukan perhitungan dosis di luar dinding primer dengan memodelkan dinding beton densitas 2,35 g/cm3 dengan ketebalan 1,45 meter dan dinding timbal densitas 11,35 g/cm3 dengan ketebalan 21,73 cm lalu dibandingkan dengan nilai dosis referensi yang ditetapkan oleh Bapeten. Hasilnya nilai dosis pada simulasi Monte Carlo EGSnrc untuk material beton dan timbal lebih rendah dibandingkan dengan nilai dosis referensi yang digunakan akibat perbedaan komposisi material penyusun beton dan timbal yang digunakan dalam simulasi dengan referensi

Concrete and lead are materials commonly used as primary radiation walls. Concrete and lead have their respective advantages and disadvantages. Concrete has a relatively cheaper price but requires a large space, while lead with a high atomic number has a higher price, but the size of the room can be minimized. Calculation of the thickness of the radiation retaining wall can be carried out using the Safety Report Series No. 47 equations with a dose limiting value in accordance with Perka Bapeten Number 3. Of 2013 and then modeling using the Monte Carlo EGSnrc to ensure the resulting dose value does not exceed the limiting dose value by Bapeten. Monte Carlo modeling is commonly used when direct measurements are not possible. The Monte Carlo simulation results are also able to represent the real conditions by entering various parameters such as modeling the linac, modeling the materials used, modeling the primary radiation walls, and performing the linac calibration so that a dose value can be compared with reference dose value used. In this study, the dose calculation outside the primary wall was carried out by modeling a concrete wall with a density of 2,35 g/cm3 with a thickness of 1,45 meters and a lead wall with a density of 11,35 g/cm3 with a thickness of 21,73 cm and then compared with the reference dose value set by Bapeten. The result is that the dose value in the Monte Carlo EGSnrc simulation for concrete and lead materials is lower than the reference dose value used due to differences in the composition of the concrete and lead materials used in the simulation with reference"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
William Maha Putra
"ABSTRAK
Fokus utama tesis ini adalah saat ini masih belum adanya kajian mendalam mengenai analisis kelayakan keekonomian pada PV Off-Grid dengan menggunakan Metode Monte Carlo dan Homer Energy. Peneliti akan membahas pemodelan yang dibangun dengan kedua metode tersebut.
Hasil penelitian ini adalah model yang dibangun ini diharapkan dapat memenuhi prinsip ?to produce electricity at the lowest possible cost? dengan mencari nilai COE (Cost of Energy) terendah dalam batasan parameternya seperti minimum NPV (Net Present Value), Cost to Benefit Ratio , DPI (Discounted Profitability Index) dan IRR (Internal Rate Return). Hasil pemodelan ini divalidasi dengan software Crystal Ball dan perhitungan manual.

ABSTRACT
The main focus in this thesis is currently still lack of study related to economic feasibility analysis on PV Off-Grid using the Monte Carlo method and Homer Energy. Researcher built the modeling constructed by these two methods.
Results of this research is a construct model to meet the principle of "to produce electricity at the lowest possible cost" by looking for the lowest value of COE (Cost of Energy) within the range of parameters such as minimum NPV (Net Present Value), Cost to Benefit Ratio, DPI (Discounted Profitability Index) and IRR (Internal Rate of Return). This modeling result is validated with Crystal Ball software and manual calculations.
"
Depok: Fakultas Teknik Universitas Indonesia, 2015
T45193
UI - Tesis Membership  Universitas Indonesia Library
cover
Harjono
"ABSTRAK
Perlakuan radioterapi pada daerah paru memerlukan perhatian khusus karena
dalam daerah tersebut terdapat berbagai jaringan dengan densitas massa maupun
densitas elektron bervariasi, oleh karena itu setiap komponen mempunyai daya
serap yang berbeda. Hasil pengobatan radioterapi dipengaruhi oleh ketepatan
sistem perencanaan pengobatan (TPS) dalam menentukan distribusi dosis dalam
pasien. Tujuan dari tesis ini adalah untuk mengetahui distribusi dosis (kurva
isodosis dan PDD) dalam paru pada simulasi Monte Carlo perlakuan radioterapi
kanker paru menggunakan sinar-x Megavolt. Penelitian ini menggunakan simulasi
Monte Carlo program paket EGSnrc yang terdiri dari BEAMnrc, dan
DOSXYZnrc. Distribusi dosis yang dihasilkan dari simulasi Monte Carlo
kemudian dibandingkan dengan data TPS. Dalam simulasi ini, energi awal
elektron yang optimum adalah 6,2 MeV untuk mengsimulasikan sinar-x 6 MV.
Simulasi Monte Carlo pada citra CT pasien kanker paru sebelah kanan dengan
kedalaman target 7.5 cm menghasilkan nilai PDD 84,4 % untuk lapangan 5 x 5
cm2 dan 80,3 % untuk lapangan 10 x 10 cm2. Untuk pasien yang sama kalkulasi
TPS menghasilkan nilai PDD pada target 75,2 % untuk lapangan 5 x 5 cm2 dan
74,8 % untuk lapangan 10 x 10 cm2. Faktor koreksi untuk luas lapangan 5 x 5 cm2
adalah 1,0 ? 1,087. Sedangkan pada luas lapangan 10 x 10 cm2 diperoleh faktor
koreksi 1,0 -1,066.

Abstract
Radiotherapy treatment in lung regions require special concern because in the area
there are different tissues of the mass density and electron density varies, so each
component has a different absorption. The results of radiotherapy are influenced
by the accuracy treatment planning system (TPS) in determining treatment dose
distribution in patient. The purpose of this thesis is to know dose distribution
(isodos curve and PDD) of the lung at the simulation Monte Carlo treatment the
lung cancer radiotherapy using x-ray Megavolt. This research using simulation
Monte Carlo, packet program EGSnrc that consist of BEAMnrc and DOSXYZnrc.
Dose distribution which is resulted from simulation Monte Carlo then compare
with TPS data. In this simulation, first energy of electron optimum is 6.2 MeV to
simulate x-ray 6 MV. Result PDD value on simulation Monte carlo with CT
images patients right lung cancer with a target depth of 7.5 cm is 84.4% for a field
of 5 x 5 cm2 and 80.3% for the 10 x 10 cm2. For the same patient TPS calculation
result PDD at the target value 75.2 % for field 5 x 5 cm2 and 74.8 % for the 10 x
10 cm2. Correction factor for field wide 5 x 5cm2 is 1.0 ? 1.087. Mean while at the
field wide 10 x 10cm2 is resulted correction factor 1.0 - 1.066."
2012
T31777
UI - Tesis Open  Universitas Indonesia Library