Arum Prasetyaningtyas
"Gabapentin, an anticonvulsant drug is used in the treatment of epilepsy, which has small dose therapeutic in blood plasma. Therapeutic drug monitoring (TDM) needs sensitive and specific analytical method.
The aim of this study was to obtaine optimized method for analytical gabapentine in plasma (in vitro) with High Performance Liquid Chromatography - fluorescence and validation the method. The method involves derivatization of the primary amine group of gabapentin with dansyl chloride produce flurescence agent and could be analyzed with high performance liquid chromatography-fluorescence.
In this research was used column Lichrosphere C18 ,10 μm, 250 x 10 μm, reverse phase with mobile phase 50 mmol/L sodium dihydrogen phosphate in 50 % acetonitrile. Flow rate of 1.7 mL/minutes, and fluorometric detection ( excitation and emission wavelength ; 318 nm and 510 nm ). For the range concentration of 0.1 ? 10 μg/mL have correlation coefficients of the calibration curves (r) is 0.9982 with a lower limit of quantification of gabapentin in 30 ng/mL. The results of validation method fulfilled for the given criterias."
Depok: Fakultas Farmasi Universitas Indonesia, 2007
T39541
UI - Tesis Membership  Universitas Indonesia Library
cover
Dwi Lestari
"Levofloksasin adalah antibakteri sintetik golongan fluorokuinolon yang memiliki efek antibakterial dengan spektrum luas. Levofloksasin merupakan obat yang diindikasikan untuk kondisi serius yang memerlukan respon pasti dan merupakan salah satu obat yang masuk dalam kategori obat wajib uji Bioekivalensi (BE), sehingga perlu dilakukan pemantauan kadarnya di dalam darah. Metode kromatografi cair kinerja tinggi (KCKT) dengan detektor fluoresensi telah dikembangkan untuk analisis levofloksasin dalam plasma manusia in vitro.
Tujuan dari penelitian ini adalah memperoleh kondisi optimum untuk analisis levofloksasin dalam plasma in vitro dan melakukan validasi metode analisis tersebut. Kromatografi dilaksanakan menggunakan teknik isokratik pada kolom fase-terbalik Kromasil® C18 (5 µm, Akzo Nobel), dengan fase gerak asetonitril-air-asam fosfat 85%-trietilamin (12:88:0,6:0,3) dengan kecepatan alir 1,25 mL/menit, dan dideteksi pada panjang gelombang eksitasi 294 nm dan panjang gelombang emisi 500 nm. Teknik penyiapan sampel dilakukan dengan cara pengendapan protein menggunakan metanol. Siprofloksasin digunakan sebagai baku dalam. Metode ini valid dengan nilai koefisien korelasi r = 0,9995 dan batas terendah kuantitasi (LLOQ) 253,8 ng/mL, hasil akurasi dengan % diff -9,64 sampai 13,38 %; presisi kurang dari 4% dan nilai perolehan kembali antara 90,36 sampai 113,38 %. Levofloksasin dalam plasma stabil selama 14 hari pada penyimpanan dengan suhu -20°C.
Kata kunci: Validasi, KCKT, levofloksasin, siprofloksasin, plasma in vitro.

Levofoxacin is a synthetic fluoroquinolone antibacterial agent that has a broad spectrum antibacterial effects. Levofloxacin indicated for critical use that needs certain respons and it is one of the drug that have to be evaluated with bioequivalency test, thereby monitoring the blood drug level is necessary. A method using high-performance liquid chromatography (HPLC) with fluorescence detector has been developed for analysis of levofloxacin in human plasma in vitro.
The objective of this research is to find out the optimum condition of levofloxacin in human plasma in vitro analysis using HPLC, and then the method was validated. The chromatography was carried out by isocratic technique on a reversed-phase Kromasil® C18 column (5 µm, Akzo Nobel) with mobile phase consisted of acetonitril-water-phosphoric acid 85%-triethylamine (12:88:0,6:0,3) at flow rate of 1.25 mL/minute, and detection was performed at excitation wavelength of 294 nm and emission wavelength of 500 nm. The sample preparation technique was protein precipitation with methanol. Ciprofloxacin was used as the internal standard. The method was valid with correlation coefficient of 0.9995 and the lower limit of quantitation was 253.8 ng/mL, accuracy with % diff -9.64 to 13.38%; precisions less than 4% and recovery percentage was 90.36 to 113.38%. Levofloxacin in plasma was stable for 14 days in -20°C.
Keyword: Validation, HPLC, levofloxacin, ciprofloxacin, plasma in vitro.
"
Depok: Universitas Indonesia, 2008
S32756
UI - Skripsi Open  Universitas Indonesia Library
cover
Fitria Casanova
"Metode kromatografi cair kinerja tinggi (KCKT) dengan detektor fluoresensi telah dikembangkan untuk analisis furosemid dalam plasma manusia in vitro. Tujuan dari penelitian ini adalah memperoleh kondisi yang optimum untuk analisis furosemid dalam plasma in vitro dan melakukan validasi metode analisis tersebut. Pemisahan dilakukan menggunakan kolom μBondapak TM C18 (Waters). Fase gerak terdiri dari asetonitril?larutan kalium dihidrogen fosfat 0,02 M (34:66) pH 3,0 dengan kecepatan alir 1,0 ml/menit dan dideteksi dengan detektor fluoresensi pada panjang gelombang eksitasi 275 dan emisi 410 nm. Teknik penyiapan sampel dilakukan dengan cara pengendapan protein menggunakan asetonitril dan ekstraksi dengan etil asetat. Propranolol HCl digunakan sebagai baku dalam. Metode ini memberikan nilai linearitas pada rentang konsentrasi 0,2016-1,5120 μg/ml dengan nilai koefisien korelasi (r=0,9980). Lower Limit of Quantitation (LLOQ) adalah 0,2016 μg/m. Metode ini telah divalidasi dan menunjukkan hasil presisisi 1,1532-10,9041% dan akurasi (% diff) -6,1839-4,5304%. Uji perolehan kembali furosemid diperoleh antara 93.8161-104.5304%. Hasil validasi metode memenuhi kriteria yang ditetapkan.

A high-performance liquid chromatography (HPLC) method with fluorescence detector for analysis furosemide in human plasma has been developed. The aim of this research is to find out the optimum condition of furosemide in human plasma in vitro analysis using HPLC and then validate the method. The separation was carried out in a μBondapak TM C18 (Waters) coloumn. The mobile phase consisted of asetonitril?potassium dihydrogen phosphate solution 0.02 M (34:66) pH 3.0 at flow rate of 1.0 ml/minute. The sample preparation technique was protein precipitation with asetonitril and extracted with ethyl acetate. Propranolol HCl was used as an internal standard. Linearity was establish for range concentration of 0.2016-1.5120 μg/ml with coefficient of corelation of 0.9980. The lower limit of quantitation (LLOQ) was found to be 0.2016 μg/ml. This method was validated with precisions 1.1532-10.9041% and accuracies (% diff) -6.1839-4.5304%. The furosemide recovery percentage was between 93.8161-104.5304%. The result of validation method fulfilled for the given criteria."
Departemen Farmasi Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2006
S32893
UI - Skripsi Membership  Universitas Indonesia Library
cover
I Kadek Arya Mulyadi
"Irbesartan merupakan obat antihipertensi yang konsentrasinya dalam darah sangat kecil sehingga diperlukan metode analisis yang sensitif, selektif dan valid untuk analisis. Pada penelitian ini, dilakukan optimasi kondisi analisis dan validasi untuk analisis irbesartan dalam plasma. Sistem kromatografi terdiri dari kolom C18 (250 mm × 4,6 mm, 5 um) dengan fase gerak asetonitril- asam format 0,1 % (46:54 v/v), pH 3,75. Larutan dideteksi pada panjang gelombang eksitasi 250 nm dan emisi 370 nm dan analisis dilakukan pada laju alir 1,0 ml/menit suhu 40 ºC. Sebagai baku dalam digunakan kalium losartan. Proses ekstraksi plasma dilakukan dengan metode pengendapan protein menggunakan asetonitril kemudian dikocok dengan vorteks selama 30 detik dan disentrifugasi pada kecepatan 10000 rpm selama 10 menit. Pada validasi dalam plasma, nilai perolehan kembali rata-rata irbesartan 96,22% serta nilai LLOQ 2 ng/ml. Metode ini juga memenuhi kriteria akurasi dan presisi intra hari dan antar hari selama 5 hari dengan % diff yang tidak melampaui ± 15%. Pada uji stabilitas, irbesartan stabil dalam plasma suhu - 20 ⁰C selama 28 hari.

Irbesartan is an antihypertensive drug whose concentration in blood is very small so it requires a sensitive method of analysis, selective and valid for analysis. In this study, carried out optimization of analytical conditions and validation for the analysis of irbesartan in plasma. Chromatography was performed on a C18 column (250 mm × 4.6 mm, 5 um) under isocratic elution with acetonitrile- 0,1 % formic acid (46:54 v/v), pH 3,75. Detection was made at excitation 250 nm and emission 370 nm and analyses were run at a flow-rate of 1.0 ml/min at a temperature of 40 ºC. Losartan potassium was used as internal standard. Plasma extraction was done by deproteination with acetonitrile, be shaken with vortex for 30 seconds, then centrifuge it on 10000 rpm for 10 minutes. In plasma validation, the recovery was 96,22%, and the lower limit of quantification (LLOQ) in plasma was 2 ng/ml. The method also fulfill the criteria for accuracy and precision intra and inter day by % diff values not exceed ± 15%. On the stability study, irbesartan in plasma temperature - 20 ⁰C has been stable for 28 days."
Depok: Universitas Indonesia, 2011
S106
UI - Skripsi Open  Universitas Indonesia Library
cover
Rina Rahmawati
"Metode kromatografi cair kinerja tinggi (KCKT) dengan detektor fluoresensi untuk menganalisis ofloksasin dalam plasma telah dikembangkan. Tujuan dari penelitian ini adalah memperoleh kondisi yang optimum untuk analisis ofloksasin dalam plasma in vitro dan melakukan validasi metode analisis tersebut. Kondisi kromatografi menggunakan kolom C18 dengan fase gerak asetonitril-larutan kalium dihidrogen fosfat 0,01 M (140:860; v/v) pH 3, kecepatan alir 1,0 ml/menit dan dideteksi dengan detektor fluoresensi pada panjang gelombang eksitasi 300 dan emisi 500 nm. Siprofloksasin digunakan sebagai baku dalam. Teknik penyiapan sampel dilakukan dengan cara pengendapan protein menggunakan asetonitril, kemudian supernatannya dipisahkan lalu diinjeksikan ke dalam kolom. Metode ini memberikan nilai linearitas pada rentang konsentrasi 1,0 -5,0 g/ml dengan nilai koefisien korelasi (r) 0,9998. Batas deteksi pada metode ini konsentrasi 0,102 g/ml dan batas kuantitasi 0,340 g/ml. Metode ini memberikan hasil uji perolehan kembali pada konsentrasi 1,02 g/ml adalah 90,668 0,2635 %, konsentrasi 3,06 g/ml adalah 92,932 0,6468 % dan konsentrasi 5,1 g/ml adalah 95,594 3.184 %.

A high-performance liquid chromatographic method (HPLC) with fluorescence detector for analyses of ofloxacin in human plasma was developed. The aim of this research is to find out optimum condition of ofloxacin in human plasma with in vitro analysis using High Performance Liquid Chromatography (HPLC) and then validate the method. Condition of chromatography using C18 column with a mixture of acetonitril-0,01 M dihydrogenpotassium phosphate solution (140:860) pH 3 as mobile phase, at flow rate 1,0 ml/menit, with fluorimetric detection was performed at 300 nm for excitation and 500 nm for emission. Ciprofloxacin was used as an internal standard. The sampel preparation technique was protein precipitation with acetonitril, the supernatant was desperated and injected into C18 column. Linearity was established for range of concentration 1.0-5.0 g/ml with coefficient of correlation of 0.9998. The limit of detection (LOD) was identifiable and reproducible at 0.102 g/ml and the limit of quantitaion (LOQ) at 0.340 g/ml. This method has ofloxacin recovery was 90.668 0,2635 % for concentration 1.02 g/ml, 92,932 0,6468 % for concentration 3.06 g/ml, and 95,594 3.184 % for concentration 5.1 g/ml."
Depok: Fakultas Farmasi Universitas Indonesia, 2006
S32859
UI - Skripsi Membership  Universitas Indonesia Library
cover
Jenni Sartika
"Metode kromatografi cair kinerja tinggi yang sederhana dan reprodusibel telah
dikembangkan untuk penentuan kadar sulfametoksazol (SMX) dan trimetoprim
(TMP) secara simultan di dalam tablet dan plasma manusia secara in vitro. Sistem
kromatografi terdiri dari kolom C18 (250 mm × 4.6 mm, 5 μm) dengan fase gerak
asetonitril-air-trietilamin (20:80:0,1 v/v), pH 5,9 ± 0,1 diatur dengan NaOH 0,2 N
dan asam asetat 1%. Larutan dideteksi pada panjang gelombang UV 240 nm dan
analisis dilakukan pada laju alir 1,0 mL/menit suhu ruang. Sebagai baku dalam
digunakan sulfadimidin. Pada validasi tablet, metode dinyatakan linear dengan
nilai koefisien korelasi (r) untuk trimetoprim dan sulfametoksazol berturut-turut
0,9994 dan 0,9996; presisi dengan nilai koefisien variasi (KV) 0,85% dan 0,98%;
serta akurat dengan nilai perolehan kembali untuk 3 konsentrasi sebesar 98% -
102%. Proses ekstraksi plasma dilakukan dengan metode pengendapan protein
menggunakan asetonitril kemudian divortex selama 40 detik dan disentrifugasi
pada kecepatan 12500 rpm selama 15 menit. Pada validasi plasma, nilai perolehan
kembali rata-rata untuk trimetoprim dan sulfametoksazol berturut-turut 94,95%
dan 86,87% serta nilai LLOQ berturut-turut 0,15 μg/mL dan 0,75 μg/mL. Metode
ini juga memenuhi kriteria akurasi dan presisi intra hari dan antar hari selama 5
hari dengan % diff tidak melampaui ± 20% pada LLOQ dan ± 15% pada
konsentrasi selain LLOQ. Pada uji stabilitas, kotrimoksazol dalam plasma
dinyatakan tetap stabil selama 30 hari."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
S33140
UI - Skripsi Open  Universitas Indonesia Library
cover
Bhaskoro T. A. W. P.
Depok: Universitas Indonesia, 2006
S32563
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
Sri Teguh Rahayu
"[ABSTRAK
Asaro valproat adalah satu dari banyak obat yang digunakan sebagai antiepilepsi dan memiliki banyak efek samping, sehingga direkomendasikan untuk menentukan konsentrasinya di dalam plasma. Penelitian ini bertujuan untuk memvalidasi metode analisis asam valproat setelah diderivatisasi dengan 2,4-dibromoasetofenon di dalam plasma in-vitro dan in-vivo, menggunakan kromatografi cair kinerja tinggi- Photo Diode Array.
Asam valproat dan asam nonanoat sebagai baku dalam diekstraksi dari plasma dengan etil asetat. Supematan yang diperoleh dinetralkan dan diuapkan, kemudian residu kering direkonstitusi dengan larutan penderivat-katalis dalam asetonitril kemudian diderivatisasi pada suhu 75°C selama 25 menit. Pemisahan dilakukan menggunakan kolom C18 Sunfire ® (250 mm x 4,6, 5 Jlm) dengan elusi isokratik menggunakan fase gerak asetonitril-air (73 :27). Pengukuran dilakukan pada panjang gelombang 294 nm dengan kecepatan alir 1,5 mL/menit. Metode ini valid berdasarkan hasil LOQ 4,75 flg/mL, perolehan kembali relatif konsentrasi rendah, sedang dan tinggi berturut-turut 100,67%, 99,78%, dan 93,16%. Koefisien variasi intra dan inter day dan persen penyimpangan (SD) dari metode ini masuk dalam kriteria penerimaan, yaitu dibawah ± 15%. Kurva kalibrasi linier dalam plasma in-vitro (Y = 0,0123 + 0,0085X) pada konsentrasi 4,75-237,75 Jlg/mL dengan nilai r =0,9999. Metode yang dihasilkan dapat diaplikasikan untuk menetapkan kadar asam valproat dalam plasma setelah pemberian secara oral tablet natrium divalproat 500 mg.

ABSTRACT
Valproic acid is one of mostly used antiepileptic drug which have side effects, so it is highly recommended to evaluate its plasma concentration The aim of the research was to validate a method for the determination valproic acid in plasma in-vitro and in-vivo after derivatization with 2,4-dibromasetofenon using high performance liquid chromatography-photo diode array. Valproic acid and internal standard nonanoic acid were extracted from plasma sample with ethyl acetate. Then supematan was neutralizatied and evaporated. dried residue reconsituted in derivate-catalyst solution then derivatized at 75°C for
25 minutes. The resulting derivatives were separated on a Sunfire C18 (250 mm x 4.6, 5 Jlm) reverse phase column with acetonitrile-water (73:27) as
mobile phase, were detected at 294 nm and analysis were tun at flow rate 1.5 mL/minute. The calibration curve in plasma in-vitro ( Y =0.0123 + 0.0085 x) presented good linier (r = 0.9999) between 4.75-237.75 Jlg/mL with LLOQ
4.75 Jlg/mL. The mean of relative recovery at low concentration, middle concentration and high concentration are 100.67%, 99.78%, and 93.16 %, respectively. Intra- and inter- day coefficient of variation and percent error value of the assay method were all acceptable range ± 15%. The presented method was might be applied to the determine of the valproic acid concentration in plasma after oral administration of 500 mg sodium divalproate.
, Valproic acid is one of mostly used antiepileptic drug which have side effects, so it is highly recommended to evaluate its plasma concentration The aim of the research was to validate a method for the determination valproic acid in plasma in-vitro and in-vivo after derivatization with 2,4-dibromasetofenon using high performance liquid chromatography-photo diode array. Valproic acid and internal standard nonanoic acid were extracted from plasma sample with ethyl acetate. Then supematan was neutralizatied and evaporated. dried residue reconsituted in derivate-catalyst solution then derivatized at 75°C for
25 minutes. The resulting derivatives were separated on a Sunfire C18 (250 mm x 4.6, 5 Jlm) reverse phase column with acetonitrile-water (73:27) as
mobile phase, were detected at 294 nm and analysis were tun at flow rate 1.5 mL/minute. The calibration curve in plasma in-vitro ( Y =0.0123 + 0.0085 x) presented good linier (r = 0.9999) between 4.75-237.75 Jlg/mL with LLOQ
4.75 Jlg/mL. The mean of relative recovery at low concentration, middle concentration and high concentration are 100.67%, 99.78%, and 93.16 %, respectively. Intra- and inter- day coefficient of variation and percent error value of the assay method were all acceptable range ± 15%. The presented method was might be applied to the determine of the valproic acid concentration in plasma after oral administration of 500 mg sodium divalproate.
]"
2011
T44141
UI - Tesis Membership  Universitas Indonesia Library
cover
Letitia Tania
"Ofloksasin merupakan salah satu antibiotika golongan fluorokuinolon generasi kedua. Konsentrasi ofloksasin dalam plasma kecil, sehingga diperlukan metode analisis yang selektif, akurat, dan sensitif. Pada penelitian ini, dilakukan optimasi dan validasi metode analisis ofloksasin dalam plasma in vitro menggunakan kromatografi cair kinerja tinggi deteksi fluoresensi dengan siprofloksasin HCl sebagai baku dalam. Pemisahan dilakukan dengan menggunakan kolom C18 (Waters, SunfireTM 5 μm; 250 x 4,6 mm) dengan fase gerak isokratik yang terdiri dari trietilamin 1% dalam air pH 3,0–asetonitril (84:16), laju alir 1,0 mL/menit, suhu kolom 40oC, dan deteksi ofloksasin dilakukan pada panjang gelombang eksitasi 300 nm dan emisi 500 nm. Waktu retensi ofloksasin dan siprofloksasin HCl adalah 7,476 menit dan 8,446 menit dengan total waktu analisis 10 menit. Proses ekstraksi plasma dilakukan dengan metode pengendapan protein menggunakan metanol melalui proses vorteks selama 2 menit dan sentrifugasi pada kecepatan 10000 rpm selama 10 menit. Hasil penelitian menunjukkan bahwa spesifisitas dan selektivitas metode ekstraksi ditunjukkan dengan tidak adanya puncak pengganggu pada saat retensi analit dan baku dalam. Validitas dan linearitas metode analisis berada pada rentang konsentrasi 21,4 ng/mL – 4280 ng/mL dengan LLOQ 21,4 ng/mL. Nilai % diff dan koefisien variasi untuk akurasi dan presisi intra hari dan antar hari tidak lebih dari + 20% untuk konsentrasi LLOQ dan + 15% untuk konsentrasi rendah, sedang, dan tinggi. Ofloksasin dalam plasma dinyatakan stabil selama 3 siklus beku dan cair, stabil minimal 24 jam pada suhu kamar dan selama minimal 28 hari pada suhu -20oC. Metode analisis ofloksasin dalam plasma ini sudah memenuhi kriteria penerimaan sesuai persyaratan validasi pedoman EMEA.

Ofloxacin is an antibiotic from second generation of fluoroquinolones group. Concentration of ofloxacin in human plasma is in low level, and due to that fact, it requires a selective, accurate, sensitive method of analysis. In this study, the optimization and validation of ofloxacin analysis in human plasma using high performance liquid chromatography-fluorescence with ciprofloxacin-HCl as an internal standard were carried out. Separation of ofloxacin was performed using C18 (Waters, SunfireTM 5 μm; 250 x 4.6 mm) column with an isocratic mobile phase consisted of triethylamine 1% in water pH 3.0–acetonitrile (84:16) in the flow rate of 1.0 mL/min, 40oC column temperature whereas the detection was carried out at excitation of 300 nm and emission of 500 nm. Retention time of ofloxacin and ciprofloxacin-HCl were 7.476 and 8.446 minutes respectively with total analytical run time was 10 minutes. Plasma extraction was done by eproteination using methanol, through the process of vortex and centrifugation (10000 rpm) for 2 minutes and 10 minutes consecutively. The results showed that the extraction method was specific and selective as there was no interfering peaks of human plasma at the retention times of the ofloxacin and the internal standard. The method was valid and linear within the concentration ranged from 21,4 ng/mL to 4280 ng/mL with LLOQ of 21,4 ng/mL. Intra-day and inter-day accuracy and presicion was not more than + 20% for LLOQ and not more than + 15% for QCL, QCM, and QCH samples in both % diff and coefficient of variation. Ofloxacin was stable in human plasma at least three freeze and thaw cycle, for at least 24 hours in room temperature and 28 days at -20oC. This bioanalytical method fulfilled the acceptance criteria following EMEA guidelines."
Fakultas Farmasi Universitas Indonesia, 2014
S57130
UI - Skripsi Membership  Universitas Indonesia Library