Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 47134 dokumen yang sesuai dengan query
cover
Harry Al Anshory
"Geothermal System Modeling has been illustrates Using Magnetotelluric Method. This method utilize a natural source Waves which are come from solar Wind, or the other Electromagnetic Waves in an ionosphere. Earlier data has been process with frequency sorting for gets the right signal points and remove noises. Then the Cokriging method utilized to remove the distortion effect With Static shift correction. After Data processing phases are finished, 2D Inversion, and 3D visualization of MT data are needed. And then for illustrates good geothermal system modeling, We must integrated MT and the others data, like geology or geochemistry data.

Dilakukan pemodelan sistem geothermal dengan menggunakan metode Magnetotelluric (MT). Metode ini menggunakan sumber alami gelombang (natural Source) yang berasal dari solar Wind, ataupun gelombang elektromagnetik lainnya yang ada di ionosfer. Pengolahan data dilakukan dengan melakukan pemilahan frekuensi yang tepat untuk mendapatkan sinyal yang dapat merepresentasikan keadaan subsurface serta untuk menghilangkan noise. Dilakukan pula koreksi pergeseran static menggunkan metode cokriging untuk menghilangkan efek distorsi. Setelah tahap pengolahan data selesai dilakukan proses inversi data MT, Visualisasi 3-Dimensi, serta dilakukan integrasi terpadu terhadap data-data yang lain, baik geologi ataupun geokimia guna mendapatkan pemodelan dari suatu system geothermal."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
S29413
UI - Skripsi Open  Universitas Indonesia Library
cover
Riri Oktobiyanti
"Lapangan geothermal Sibayak terletak di kawasan utara Great Sumatra Fault Zone (GSFZ) yang memiliki topografi yang tinggi di dalam kaldera Singkut. Ditinjau dari kondisi geologinya, lapangan ini memiliki prospek geothermal yang ditandai dengan keberadaan manifestasi panas berupa solfatara, fumarole, chloride springs dan silica sinters. Untuk menginvestigasi struktur bawah permukaan secara lebih detail, maka dilakukan reinterpretasi data magnetotellurik dan gravitasi. Dari pemodelan 2-Dimensi MT yang menggunakan software MT2Dinv dan 3-Dimensi MT menggunakan software GeoSlicer-X maka dapat diketahui clay cap mempunyai nilai resistivitas 5-10 Ωm. Zona reservoir diindikasikan dengan harga resistivitas 50- 200 Ωm yang terdapat di bawah zona clay cap dan berada pada kedalaman sekitar 1600m. Pusat reservoir terdapat pada daerah yang meliputi Gunung Sibayak dan Gunung Pratektekan dengan luas yang diperkirakan sekitar 4 km². Pemodelan data gravitasi mendukung gambaran stuktur utama yang berupa kaldera Singkut dan sesarsesar yang berarah barat laut-tenggara. Berdasarkan studi ini dapat direkomendasikan sumur produksi diarahkan pada pusat reservoir, sedangkan reinjeksi ditempatkan di daerah dekat reservoir tetapi yang diduga memiliki hubungan permeabilitas, yaitu di sekitar batas kaldera sebelah selatan.

Sibayak geothermal field is situated in the northern Great Sumatra Fault Zone (GSFZ), which has high topography inside Singkut caldera. From the geological point of view, Sibayak field is a potential geothermal area supported by the occurrence of surface manifestations such as solfataras, fumaroles, chloride springs and silica sinters. To investigate subsurface geological structure, reinterpretation of the Magnetotelluric and gravity data were carried out. Two-dimensional modeling of MT data using MT2Dinv software and 3-D visualization of the MT data using GeoSlicer-X have delineated clay cap with resistivity of 5-10 ohm. Reservoir zone is indicated by slightly higher resistivity (50 - 200 ohm-m) below the clay cap located in the depth of about 1600m. Center of reservoir is probably located in the area between Mt Sibayak and Mt Pratektekan covering about 4 km². The gravity data modeling supports the existence of main structures, those are Singkut caldera and faults zone oriented in the northwest - southeast direction. Based on this study, it is recommended that the production wells shoud be located to the central of reservoir and reinjection wells should be sited to the area close to the main reservoir which has permeability connection, that is in the southern caldera boundary."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2009
S29441
UI - Skripsi Open  Universitas Indonesia Library
cover
Lendriadi Agung
"Area prospek geothermal Tawau, Sabah, Malaysia salah satu daerah prospek di Malaysia yang terbentuk karena proses tektonik di daerah Sulu, dengan formasi batuan kuarter. Area prospek geothermal ini memiliki mata air panas tipe klorida, mata air panas tipe steam-heated, dan mata air panas tipe bikarbonat yang keseluruhannya tersebar di sekitar area prospek. Dari hasil perhitungan geotermometri diperoleh area prospek geothermal Tawau memiliki temperatur 190-236 0C, yang dapat dikategorikan sebagai moderate to high temperature geothermal system. Untuk mengetahui mengenai batas, kedalaman, dan geometri dari reservoir yang ada, dilakukan pengukuran dengan metode Magnetotellurik (MT) dan Time Domain Electromagnetic (TDEM). Pengukuran dilakukan dengan desain gridding agar dapat diketahui penyebaran resistivitas dari arah Utara-Selatan maupun Barat-Timur. Data MT tersebut dikoreksi terlebih dahulu terhadap efek statik dan noise dengan menggunakan TDEM dan Remote Reference sebelum nantinya siap diinterpretasi. Pemodelan sistem geothermal dari data magnetotellurik dengan menggunakan analisa 2-dimensi dan visualisasi 3-dimensi. Diperoleh hasil area prospek geothermal ini memiliki luas reservoir sekitar 15 km2, dan potensi untuk dikembangkan menjadi pembangkit listrik mencapai 84 MW, dengan rekomedasi pengeboran yang berada di dekat gunung Maria di bagian Utara Tawau.

Geothermal prospect area in Tawau, Sabah, Malaysia is one of the prospect area developed by tectonic process in Sulu, with quaternary formation. This geothermal prospect area has chloride, steam-heated, and bicarbonate hot springs. Based on geothermometry calculation the geothermal prospect area of Tawau has temperature 190-236 0C which is categorized as a moderate to high temperature geothermal system. To estimate the boundary, depth, and geometry of the reservoir, Magnetotelluric (MT) and Time Domain Electromagnetic (TDEM) methods were used. Data acquisition was designed gridding method to delineated resistivity distribution in North-South or West-East orientation. MT data was then corrected for static effect and possible noise using TDEM and remote reference before comprehensive interpretation. Modeling of the geothermal system was carried out by using 2-dimensional MT resistivity and 3-dimensional visualization. As a result we could delineated the geothermal prospect area is about 15 km2 with its potential of up to 84 MWe. In addition, the with drilling recommendation is proposed is the promising zone (close to Mt. Maria flank)."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2009
S29365
UI - Skripsi Open  Universitas Indonesia Library
cover
Henny Lastriany
"Metode magnetotellurik (MT) merupakan salah satu tools dalam geofisika yang memanfaatkan gelombang elektromagnetik natural. Salah satu aplikasi metode ini yang optimal adalah untuk mendelineasi sistem geothermal yang memiliki kontras resistivitas, dalam penelitian tugas akhir ini yaitu sistem geothermal daerah "X". Parameter yang diukur yaitu fluktuasi medan listrik dan medan magnet terhadap waktu dan parameter yang dianalisis yaitu resistivitas semu dan fase. Beberapa langkah dalam pengolahan data magnetotellurik antara lain : pemilihan data time series, transformasi Fourier, robust processing, rotasi, seleksi crosspower, koreksi static shift serta inversi 2-D. Inversi 2-D yang dilakukan pada empat lintasan mampu menggambarkan sebaran resistivitas bawah permukaan sehingga pemodelan sistem geothermal secara utuh dapat digambarkan. Diintegrasikan dengan data geologi dan geokimia, sistem geothermal daerah "X" dapat dimodelkan terpusat pada bagian tenggara daerah penelitian dengan zona upflow ditandai oleh manifestasi "4 munir" serta zona outflow mengarah ke barat laut dan selatan daerah penelit ian. Sistem yang terdapat pada daerah "X" ini merupakan sistem dengan tipe hydrothermal volcanic system dengan high temperature system. Hasil model sistem geothermal menunjukkan bahwa luasan reservoir sekitar 21 km2 dan perkiraan potensi sistem geothermal daerah "X" ini untuk dijadikan pembangkit listrik sebesar 204 MWe.

Magnetotelluric (MT) method is one of the tools in geophysics that have captured electromagnetic waves from subsurface by the response of natural electromagnetic waves as the source. One of the most useful application MT method is used to delineate geothermal system that presented by resistivity contrast. In this work, we have delineated the geothermal system in "X" area. Firstly, we have analyzed time series data from good time series data selection. Time domain data was transformed by FFT into frequency domain. Then we have also perform robust processing, rotation, crosspower selection and 2-D inversion respect to FFT result‟s. The four profiles of area were obtained by 2-D inversion in subsurface resistivity distribution. Interestingly, the results showed a whole geothermal system model. With integrated geology and geochemistry data, geothermal system at "X" area can be modeled centralized on southeast research area, with upflow zone is characterized by "4 munir" surface manifestation and outflow zone leads to northwest so do south research area. Geothermal system at this "X" area is hydrothermal volcanic system type with high temperature system. As a result from geothermal system model shows that reservoir is about 21 km2 wide and estimated potential reserve up to 204 MWe."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2013
S52802
UI - Skripsi Membership  Universitas Indonesia Library
cover
Zulimatul Safa`ah Praromadani
"Daerah prospek geotermal Telomoyo terletak sekitar 34 km sebelah selatan dari kota Semarang, Jawa Tengah. Geomorfologi Telomoyo terdiri atas komplek Gunung Telomoyo yang didominasi batuan vulkanik plistosen-kuarter berupa piroklastik dan lava dengan komposisi andesit-basaltik. Manifestasi permukaannya berupa mata air panas dan batuan teralterasi. Pendugaan temperature reservoirnya berkisar 2300C.
Dari data gravitasi diketahui ada intrusi di bawah kaldera Telomoyo. Untuk mengetahui informasi bawah permukaan daerah prospek geothermal Telomoyo, dilakukan survey magnetotellurik (MT). Selanjutnya data MT yang diperoleh diolah melalui tahapan pemilihan data time series sampai inversi 2D dan divisualisasikan ke dalam 3D.
Hasil penelitian ini memperlihatkan lapisan resistivitas sangat rendah (<15 Ωm), diinterpretasikan sebagai lapisan penudung (clay cap). Lapisan yang berada di bawah clay cap dengan nilai resistivitas sekitar 50-150 Ωm diinterpretasikan sebagai reservoir dari sistem geotermal. Lapisan heat source tampak berbentuk dome dengan nilai resistivitas >250 Ωm. Selanjutya model dari data MT tersebut diintegrasikan dengan data geologi, geokimia, dan geofisika (gravitasi) sehingga dapat dibuat model konseptual yang dapat mendelineasi sistem geotermal daerah prospek Telomoyo dimana potensi geotermalnya berkisar 125 MWe.

Telomoyo geothermal prospect is located about 34 km southern from Semarang, Central Java. Geomorphology of Telomoyo consist of Mount Telomoyo dominated by volcanic plistocene- quartenary formation consists of pyroclastic and andesit-basaltic lava. Surface manifestation are hot springs and alterationed rock. The estimation of reservoir temperature is about 2300C.
From gravity data we can see an intrusion under Telomoyo's caldera. To get subsurface information about Telomoyo geothermal prospect , MT survey was done. MT data is processed through data selection stage of time series up to 2D inversion and visualized into 3D. The result of the reseach shows that there is very low resistivity layer (<15 Ωm), interpreted as clay cap.
The layer under clay cap with resistivity value is about 50-150 Ωm interpreted as reservoir of geothermal system. Heat source layer has dome shape wih resistivity value >250 Ωm. Moreover, the model from MT data integrated with geology, geochemistry, and geophysics (gravity) data so the conceptual model that delineated geothermal system of Telomoyo prospect area of which geothermal potension about 125 Mwe can be made.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
S44548
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dandi Baskoro Soebakir
"Keberadaan struktur geologi merupakan salah satu parameter penting dalam menentukan zona permeabel pada suatu sistem geotermal. Penelitian ini dilakukan di salah satu area prospek geotermal di zona Sistem Sesar Sumatera (GSF) yang termasuk dalam segmen Angkola dan Barumun yang bertujuan untuk mengidentifikasi kemenerusan fitur permukaan hingga bawah permukaan terutama struktur geologi yang berkaitan erat dengan zona permeabel dengan mengintegrasikan data geologi, geokimia, dan geofisika. Teknologi remote sensing digunakan untuk mengidentifikasi struktur geologi yang terobservasi di permukaan yang dikorelasikan dengan persebaran manifestasi permukaan. Namun, tidak semua struktur geologi yang terobservasi di permukaan dapat diamati dan kemenerusannya dari permukaan hingga bawah permukaan dilakukan dengan pendekatan geofisika menggunakan data magnetotelurik (MT) dan gravitasi. Interpretasi struktur geologi permukaan berdasarkan analisis remote sensing dan persebaran manifestasi permukaan memiliki korelasi yang positif dengan hasil gravitasi adanya struktur graben dari zona GSF yang memiliki orientasi baratlaut-tenggara. Kelurusan dan karakteristik (arah dan kemiringan) struktur ditandai dengan adanya kontras nilai gravitasi, nilai Horizontal Gradient Magnitude (HGM) maksimum, dan nilai zero Second Vertical Derivative (SVD) serta analisis Multi Scale-Second Vertical Derivative (MS-SVD). Hasil interpretasi struktur bawah permukaan gravitasi berkorelasi positif dengan analisis parameter MT (splitting curve MT) yang dapat mengindikasi zona struktur bawah permukaan. Gabungan interpretasi struktur permukaan dan bawah permukaan teridentifikasi adanya 5 struktur (F1, F2, F3, F4, dan F5) yang diklasifikasikan sebagai Struktur Pasti (F1, F2, F3, dan F4) dan Struktur Diperkirakan (F5) yang memiliki orientasi baratlaut-tenggara. Struktur F3 yang berorientasi baratlaut-tenggara merupakan struktur utama yang berperan sebagai fluid conduit (zona permeabel) yang dibuktikan dengan adanya manifestasi mata airpanas bertipe klorida. Berdasarkan hasil pemodelan inversi 3-D MT dan pemodelan kedepan 2-D gravitasi dapat mendelineasi zona reservoir pada kedalaman 1500 – 2000-meter yang dikontrol oleh struktur F3 dan zona reservoir berasosiasi dengan batuan metasediment yang nantinya dapat menentukan lokasi sumur pengeboran. Untuk memvisualisasikan sistem geotermal secara komprehensif, maka dikembangkan model konseptual dengan mengintegrasikan model geofisika yang memiliki kualitas data optimum dengan data geologi dan geokimia yang saling berkorelasi, sehingga dapat dijadikan dasar dan acuan dalam menentukan lokasi pengembangan sumur produksi dan reinjeksi dan menurunkan resiko kegagalan dalam well targeting.

The existence of geological structures is one of the important parameters in determining the permeability zone in a geothermal system. This study was conducted in one of the geothermal prospect areas in the Sumatera Fault System (GSF) zone included in the Angkola and Barumun segments which aims to identify the continuity of surface to subsurface features, especially geological structures that are closely related to permeability zones by integrating geological, geochemical, and geophysical data. Remote sensing technology is used to identify geological structures observed at the surface that are correlated with the distribution of surface manifestations. However, not all surface-observed geological structures can be observed and their continuity from the surface to the subsurface is done with a geophysical approach using magnetotelluric (MT) and gravity data. Interpretation of surface geological structures based on remote sensing analysis and the distribution of surface manifestations has a positive correlation with the gravity results of the graben structure of the GSF zone which has a northwest-southeast orientation. The alignment and characteristics (direction and slope) of the structure are characterized by the contrast of gravity values, maximum Horizontal Gradient Magnitude (HGM) values, and zero Second Vertical Derivative (SVD) values as well as Multi Scale-Second Vertical Derivative (MS-SVD) analysis. The results of gravity subsurface structure interpretation are positively correlated with MT parameter analysis (splitting curve) which can indicate subsurface structure zones. The combined interpretation of surface and subsurface structures identified 5 structures (F1, F2, F3, F4, and F5) classified as Certain Structures (F1, F2, F3, and F4) and Estimated Structure (F5) that have a northwest-southeast orientation. The northwest-southeast oriented F3 structure is the main structure that acts as a fluid conduit (permeability zone) as evidenced by the manifestation of chloride-type hot springs. Based on the results of 3-D MT inversion modeling and 2-D gravity forward modeling, it can delineate the reservoir zone at a depth of 1500 - 200 meters controlled by the F3 structure and the reservoir zone is associated with metasedimentary rocks which can later determine the location of drilling wells. To visualize the geothermal system comprehensively, a conceptual model was developed by integrating geophysical models that have optimum data quality with geological and geochemical data that are correlated, so that it can be used as a basis and guide in determining the location of production well development and reinjection and reduce the risk of failure in drilling targets."
Jakarta: Fakultas Matematika Dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Mufidatul Khoiroh
"ABSTRAK
Daerah di sekitar kawasan X merupakan kawasan yang berupa dataran tinggi yang berada di kawasan kompleks vulkanik. Di kawasan ini terdapat kawah panas yang menunjukkan aktivitas hidrotermal, dimana manifestasi utamanya muncul di kawasan X berupa fumarol Cd. Salah satu sasaran dalam eksplorasi panas bumi adalah menemukan titik-titik pemboran yang berkorelasi dengan zona suhu tinggi dan zona yang memiliki kriteria permeabilitas tinggi, dimana zona tersebut berkorelasi dengan struktur geologi. Berdasarkan analisis kurva pemisahan dan diagram kutub, terdapat sesar Wp 1, Ga, Wp 2, Pk, Dg, Cd, dan Jm yang umumnya berarah barat laut-tenggara. Sistem panas bumi wilayah X terutama dikendalikan oleh sesar Cd. Adanya struktur sesar memungkinkan fluida dari kawasan timur Jm, Kaipohan Wp, dan sekitar kawasan Pk mengalir sebagai imbuhan. Selain itu, berdasarkan hasil inversi 3 dimensi, data magnetotelurik menunjukkan bahwa zona alterasi sebagian besar terkonsentrasi pada kedalaman sekitar 1500 m hingga 1000 m dengan indikasi bahwa batas zona konduktor (BOC) sudah mulai terlihat. pada ketinggian sekitar 1000 m dan zona reservoir berada pada kedalaman dibawah 1000. m yang ditunjukkan dengan nilai resistivitas sedang antara 20 - 63 Ωm. Zona resistif basement pada kedalaman -3000 m ditunjukkan dengan sebaran nilai resistivitas yang tinggi, dengan sumber utama didominasi oleh pegunungan Dm, Al, dan Jm dengan satuan litologi dominan berupa lahar andesit. Zona upflow kemungkinan terletak di sekitar prospek zona Cd atau di sekitar titik MT-37, dengan arah outflow ke barat daya. Berdasarkan pengukuran panas bumi, temperatur prospek utama diperkirakan 270 0C. Lokasi sasaran pemboran dapat ditarik di sekitar geothermal Cd dengan kedalaman pemboran yang dapat ditarik sekitar 1000 m sampai 1500 m di bawah permukaan.
ABSTRACT
The area around area X is an area in the form of a plateau located in a volcanic complex area. In this area there are hot craters showing hydrothermal activity, where the main manifestation appears in region X in the form of fumarole Cd. One of the targets in geothermal exploration is to find drilling points that are correlated with zones of high temperature and zones that have high permeability criteria, where these zones are correlated with geological structures. Based on the analysis of the separation curve and polar diagram, there are faults Wp 1, Ga, Wp 2, Pk, Dg, Cd, and Jm which generally run northwest-southeast. The X region geothermal system is mainly controlled by the Cd fault. The existence of a fault structure allows fluid from the eastern region of Jm, Kaipohan Wp, and around the Pk area to flow as a recharge. In addition, based on the results of the 3-dimensional inversion, the magnetotelluric data shows that the alteration zone is mostly concentrated at a depth of about 1500 m to 1000 m with an indication that the conductor zone boundary (BOC) is already visible. at an altitude of about 1000 m and the reservoir zone is at a depth below 1000. m which is indicated by a moderate resistivity value between 20 - 63 Ωm. The basement resistive zone at a depth of -3000 m is indicated by the distribution of high resistivity values, with the main source being dominated by mountains Dm, Al, and Jm with the dominant lithological unit in the form of andesite lava. The upflow zone is likely located in the vicinity of the prospect zone Cd or around the point MT-37, with the outflow direction to the southwest. Based on geothermal measurements, the temperature of the main prospect is estimated to be 270 0C. The drilling target location can be drawn around the geothermal Cd with a drilling depth that can be drawn from about 1000 m to 1500 m below the surface."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ritonga, Ahmad Fitra
"ABSTRAK
Penelitian di daerah prospek geothermal ldquo;X rdquo; bertujuan untuk mendelineasi zona permeable berdasarkan data audio magnetotellurik dan gravitasi yang dipadu dengan data geologi dan geokimia. Analisis data geologi dengan teknik remote sensing diidentifikasi dua struktur utama yang mengarah dari Utara - Selatan dan Barat Laut ndash; Tenggara dan terdapat satu lokasi alterasi yang berkorelasi dengan kemunculan manifestasi permukaan. Analisis data geokimia menunjukkan bahwa manifestasi fumarol merupakan manifestasi tipe upflow dan manifestasi air panas AP X1 dan AP X2 merupakan tipe manifestasi outflow. Geotermometer gas menunjukan temperatur reservoar adalah sekitar 290 C. Analisis data geofisika menggunakan 35 data titik ukur audio magnetotellurik dan 194 titik ukur gravitasi. Berdasarkan inversi 3D data AMT dan forward modelling gravitasi terdapat lapisan penudung cap rock dengan nilai resistiviatas rendah le; 10 ?m dan densitas 2.1 gr/cc yang diduga merupakan batuan produk Gunung BA Muda yang mengalami alterasi. Batuan cap rock sudah terlihat mulai dari permukaan dan menebal ke arah manifestasi AP X1 dengan kedalaman sekitar 500 meter dengan ketebalan 500 meter hingga 1000 meter Di bawah batuan cap rock terdapat batuan reservoar dengan nilai resistivitas sedang >10 s.d 65 ?m dan densitas 2,6 gr/cc. Batuan ini diinterpretasikan sebagai respon dari batuan Lava BU. Lapisan heat source berada di bawah reservoar dengan nilai resistivitas >100 ?m yang diduga merupakan satuan batuan aktivitas vulkanik Gunung BA. Top of Reservoir TOR diperkirakan berada pada kedalaman 500 m dari permukaan yang teridentifikasi pada elevasi 0 meter. Analisis kurva splitting diperoleh bahwa zona permeable kemungkinan berada di sebelah Timur Gunung BA dikarenakan area tersebut cenderung naik dibandingkan dengan area sekitarnya. Analisis kurva splitting ini memberi penguatan terhadap interpretasi struktur terpadu interpretasi struktur berdasarkan Geologi, FHD, peta resistivitas 3D AMT per elevasi . Luas zona prospek sebesar 1.5 km2 yang berada disebelah Timur Gunung BA.

ABSTRACT
The research in ldquo X rdquo geothermal prospect area aimed to delineate permeable zone based on audio magnetotelluric and gravity data integrated with geology and geochemistry data. Geological analysis with remote sensing technique identified two main structures that lead from North ndash South and Northwest ndash Southeast and found one altered location which correlate with the appearance of surface manifestation. Geochemical analysis shows that fumarole is the upflow zone and manifestations which appear in AP X1 and AP X2 are the outflow zone. Gas geothermometer shows that the reservoir temperature is about 290 C. The analysis of geophysics data used 35 audio magnetotelluric points and 194 gravity points. Based on 3D AMT data inversion and gravity forward modelling, there is cap rock layer with low resistivity le 10 m and density 2.1 gr cc expected as product rocks of young AB Mountain that altered. Cap rock finds in the surface and thickened toward AP X1 manifestation with depth about 500 meters with thickness 500 meters up to 1000 meters. Under cap rock layer, there is reservoir rock layer with medium resistivity 10 s.d 65 m and density 2,6 gr cc. This rock is interpreted as the response from Lava BU rocks. Heat source layer is located underneath reservoir rock layer with resistivity value 100 m which is interpreted as BA vulcanic rock. Top of Reservoir TOR is estimated in depth of 500 m from the surface and identified at elevation 0 meter. Analysis of curve splitting is obtained that permeable zone possibly located at East BA Mountain because the area were tending to increase compared with the surrounding area. Analysis of curve splitting strengthen integrated interpretation structure interpretation structure based on Geology, FHD, Map of 3D AMT resistivity per elevation . The prospect area is about 1.5 km2 which located in East BA Mountain."
2017
T47436
UI - Tesis Membership  Universitas Indonesia Library
cover
Desy Rhobiatul Adhawiyah
"Sistem panasbumi lapangan "D" merupakan sistem panasbumi tipe kaldera yang terbentuk karena aktivitas tektonik dan vulkanik. Formasi batuannya merupakan formasi sedimen berumur tersier di bagian bawah, dengan formasi batuan beku berumur kuarter di bagian atasnya. Manifestasi permukaan yang ada berupa fumarol di atas Gunung Taf dan Gunung "D" serta mata air panas pada arah tenggara dari pusat sistem. Data MT menunjukkan adanya up-dome shape sedangkan data gravity menunjukkan keberadaan reservoar yang ditandai dengan anomali gravitasi rendah. Untuk memahami karakteristik reservoar, letak sumber panas, serta hidrogeologi, dilakukan pemodelan sistem panasbumi lapangan "D". Pemodelan dilakukan secara forward dengan software TOUGH2 dan inversi dengan software iTOUGH2. Input pemodelan forward dibuat berdasarkan data geologi, geofisika, geokimia, dan data sumur.
Output yang dihasilkan digunakan sebagai input untuk proses inversi dengan tujuan optimalisasi model Natural State yang ingin dicapai. Ketercapaian kondisi natural state ditunjukkan dengan adanya kesesuaian antara profil temperatur sumur dengan hasil pemodelan. Hasil pemodelan menunjukkan bahwa sumber panas berada di bawah Gunung Taf dan Gunung "D", dengan outflow ke arah tenggara, serta keberadaan zona recharge di sebelah barat daya dari sistem. Top reservoar diperkirakan berada pada elevasi 0 m. Dari profil temperatur juga diberikan rekomendasi wilayah yang tepat sebagai sumur produksi dan sumur reinjeksi.

Geothermal system at field "D" is a caldera-type system which was developed by volcanism and tectonism activities. The "D" area composed of pre-Tertiary-Tertiary sedimentary formation in the lower part, and unconformably covered by Quaternary volcanic rock formation. Surface manifestations present in this area are fumaroles right above Mount Taf and Mount "D" and hot-springs in north east and south east direction from the center of the system. MT data inform the present of up-dome shape, while gravity data show the reservoir location with low gravity anomaly. For understanding the characteristic of reservoir, heat source location, and hydrogeology, the modeling of geothermal system at field "D" was conducted using TOUGH2 and iTOUGH2 simulator in forward and inverse modeling respectively. Input for forward modeling were composed based on geological, geophysical, geochemical and well-bore data.
The calculated output from forward modeling was then used as input data for inversion process in order to optimize the Natural State condition being obtained. Natural State condition is reached when the temperature profiles of the model show relatively good agreement with measured temperature from wells. The result indicates that the heat source is located beneath Mount Taf and Mount "D", with present outflow to the south east and north east direction outward the system, while recharge zones are located at south west and north west from the system. Top of reservoir was estimated to be 200 m above sea level. Recommendation for production and reinjection wells is also given based on measured temperature profiles.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2013
S45940
UI - Skripsi Membership  Universitas Indonesia Library
cover
"The Cinnamon Geothermal prospect is located in the northeastern of
Mayonnaise Island, Indonesia. It is located in quaternary volcanic terrain
about 750 m asl. The various types of surface manifestations e.g. solfatara,
fumarole, steaming ground, mud pools and hotsprings are concentrated near
Cinnamon village. Few reconnaissance surveys had been conducted since
year 1977. To model the Geothermal Prospect of Cinnamon, one can use
Magnetotelluric and Gravity method.
Magnetotelluric method uses telluric current as natural source to
identify the resistivity properties of subsurface rocks. This resistivity section
can be used to identify the occurrence of clay cap. Gravity method can be
used to map the density response from the subsurface to detect a massive
density contrast that match the geological condition.
The integrated model of Cinnamon combining geophysical,
geochemical and geological data can be used to locate the reservoir, outflow,
and upflow for further drilling purpose and exploitation."
Universitas Indonesia, 2007
S28903
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>