Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 159823 dokumen yang sesuai dengan query
cover
Universitas Indonesia, 2006
S29211
UI - Skripsi Membership  Universitas Indonesia Library
cover
Sasono Wijanarko
"Penentuan respon detektor dilakukan dengan menggunakan detektor Unfors, detektor jenis Farmer dan detektor TK 30cc. Penelitian menggunakan pesawat sinar-X Y.TU 320-D03. Besar energi yang digunakan 50 sampai 100 kV pada kualitas RQA berdasarkan Technical Report Series no.457. Penelitian ini menghasilkan respon detektor jenis Farmer bernilai besar pada energi tinggi, sehingga menghasilkan faktor koreksi yang kecil. Dengan demikian eisiensi detektor Farmer pada kualitas RQA lebih baik pada energi tabung (kV) yang tinggi. Dan untuk detektor TK 30 cc menghasilkan nilai faktor koreksi yang cenderung datar.

Radiodiagnostic detector response determination using Unfors detector, Farmer detector and TK 30cc detector. The research using X-ray machine Y.TU 320-D03. The energy that used is 50 until 100 kV for RQA quality based on Technical Report Series no. 457. This research resulting that Farmer detector response have a greater value for high energy, so that resulting small value of correction factor. Thus, the efficiency Farmer detector much better for high energy of tube X-ray machine. And, for TK 3Occ detector resulting flat value of correction factor."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
S29385
UI - Skripsi Open  Universitas Indonesia Library
cover
Michael Christian Satrio
"Dalam menjamin keselamatan pasien radiologi diagnostik yang menggunakan modalitas pesawat sinar-X radiografi umum dan mobile di Indonesia diperlukan adanya kendali mutu modalitas radiologi diagnostik. Salah satu bentuk kendali mutu tersebut adalah uji kesesuaian. Pada penelitian ini, telah dilakukan analisis dan evaluasi terhadap setiap parameter pengujian yang terdapat dalam uji kesesuaian dari 1.016 data hasil uji kesesuaian pesawat sinar-X radiografi umum dan 480 data hasil uji kesesuaian pesawat sinar-X mobile dalam bentuk sertifikat hasil uji kesesuaian yang telah dihimpun Badan Pengawas Tenaga Nuklir (BAPETEN) dari tahun 2019 hingga 2020. Dalam proses analisis dan evaluasinya, kumpulan data tersebut dikelompokkan dan dibandingkan perbedaan hasil pengujiannya berdasarkan usia modalitas. Selain itu, dari data tersebut juga dapat ditinjau tingkat implementasi dari sistem AEC dari modalitas pesawat sinar-X radiografi umum. Berdasarkan hasil evaluasi dan analisis yang dilakukan, dari 1.016 sertifikat hasil uji kesesuaian pesawat sinar-X radiografi umum yang telah direkapitulasi, sebanyak 89,9% dari jumlah tersebut berada pada kategori andal, 5,2% berada pada kategori andal dengan perbaikan, dan 4,9% berada pada kategori tidak andal. Sedangkan, dari 480 sertifikat hasil uji kesesuaian pesawat sinar-X mobile yang telah direkapitulasi, sebanyak 84,8% dari jumlah tersebut berada pada kategori andal, 2,1% berada pada kategori andal dengan perbaikan, dan 13,1% berada pada kategori tidak andal. Dari evaluasi yang dilakukan, tidak terdapat korelasi linear antara usia modalitas dan data hasil uji kesesuaian. Namun, terdapat faktor jenis reseptor citra dan metode pengujian yang mempengaruhi data tersebut. Selain itu, hanya terdapat 9.15% dari keseluruhan sertifikat hasil uji kesesuaian pesawat sinar-X radiografi umum yang memuat data hasil uji parameter AEC.

In ensuring the safety of diagnostic radiology patients using general and mobile radiography X-ray modalities in Indonesia, it is necessary to have quality control of diagnostic radiology modalities. One form of quality control is a compliance test. In this study, analysis and evaluation have been carried out on each test parameter contained in the compliance test from 1,016 data from the compliance test results for general radiographic X-ray modality and 480 data from the compliance test results for mobile X-ray modality in the form of a certificate of compliance test results that have been collected by Badan Pengawas Tenaga Nuklir (BAPETEN) from 2019 to 2020. In the process of analysis and evaluation, the data sets are grouped and compared with differences in test results based on the age of modality and type of image receptor. In addition, from these data, it can also be seen the level of implementation of the AEC system from the general radiographic X-ray modality. Based on the results of the evaluation and analysis that have been carried out, from the 1,016 certificates of compliance test results for general radiographic X-rays that have been recapitulated, as many as 89.9% of these are in the reliable category, 5.2% are in the reliable category with repairs, and 4,9% are in the unreliable category. Meanwhile, from the 480 certificates of compliance test results for mobile X-ray modality that have been recapitulated, 84.8% of them are in the reliable category, 2.1% are in the reliable category with repairs, and 13.1% are in the unreliable category. From the evaluation have been carried out, there is no linear correlation between the age of the modality and the data from the compliance test. However, there are types of image receptors and test methods that affect the data. In addition, there are only 9.15% of the overall certificates of compliance test results for general radiographic X-ray modality contain data on the results of the AEC parameter tests."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Intan Aprillya Rizki
"Penentuan spektrum sinar X perlu dilakukan untuk mengetahui kualitas radiasi yang keluar dari tabung sinar X, selain karakteristik detektor yang digunakan untuk pengukuran yang harus diketahui untuk mencegah terjadinya kesalahan penafsiran spektrum hasil pengukuran. Penelitian ini menggunakan pesawat sinar X YXLON YTU ? 320 D303 dan menggunakan detektor XR ? 100 ? CdTe serta software XCOMP5R. model pesawat ini diletakkan pada jarak 100 cm dari detektor, dengan ketebalan detektor CdTe sebesar 1 mm dan berjari ? jari sebesar 0.15 mm. Penelitian juga mencari hubungan spektrum sinar X dengan XCOMP5R untuk mencari karakteristik detektor CdTe dengan mengasumsikan spektrum XCOMP5R sebagai spectrum ideal, dari spektrum sinar X pengukuran dapat diketahui karakteristik dari detektor CdTe tersebut. Karakteristik detektor yang muncul pada saat pengukuran adalah energy K edge dan sinar X karakteristik Cd dan Te yaitu Cd nilai K edge 26.704 keV, ka1 22.982 keV, ka2 23.172 keV, kb1 26.093 keV, kb2 26.641 keV. Te nilai K edge 31.800 keV, Ka1 27.200 keV, Ka2 27.471 keV, Kb1 30.993 keV, Kb2 31.698 keV. Sebelum melakukan pengukuran spektrum, kita harus mengetahui karakter detektor untuk mencegah terjadinya penafsiran data.

Determination of the X-ray spectrum is important to know the quality of the radiation of the X-ray tubes, in the other hand it is important to characterize the detector used for measurement to prevent misinterpretation of the spectrum from measurement results. The study use X-ray tube YXLON YTU - 320 D303 and using the detector XR ? 100 ? CdTe and XCOMP5R software. X-ray tube model is placed at a distance of 100 cm from the detector, CdTe detector with a thickness of 1 mm and the fingers of 0.15 mm. the studies also aim spectrum and also to characterize it to find relation between XCOMP5R X-ray spectrum and CdTe detector by assuming the spectrum XCOMP5R as an ideal spectrum. Detector characterize that appears at measurement is the energy of K edge and X-ray characteristics of Cd and Te. The value of Cd, K edge is 26.704 keV, Ka1 is 22.982 keV, Ka2 is 23.172 keV, Kb1 is 26.093 keV, Kb2 is 26.641 keV. Values of Te, K edge is 31.008 keV, Ka1 is 27.200 keV. Ka2 is 27.471 keV, Kb1 is 30.993 keV, Kb2 is 31.698 keV. Before using detector for measurements, we must know the characteristics of detector it is important that."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
S849
UI - Skripsi Open  Universitas Indonesia Library
cover
Kania Intan Septianty
"Uji kontrol kualitas pada sistem pencitraan sinar-X diperlukan untuk mengetahui kualitas sistem pencitraan sinar-X. Kualitas sistem pencitraan sinar-X yang baik akan menghasilkan kualitas citra yang baik dengan mengikuti prinsip ALARA (as low as reasonably achievable). Penelitian ini dilakukan untuk mendapatkan analisa dalam melakukan uji kontrol kualitas dengan menggunakan fantom in-house. Parameter Modulation Transfer Function (MTF) dan Signal Difference to Noise Ratio (SDNR) digunakan sebagai parameter yang merepresentasikan kualitas sistem pencitraan sinar-X dan kualitas citra yang dihasilkan. MTF merupakan parameter performa sistem pencitraan sinar-X. Penelitian menunjukkan bahwa MTF tidak memiliki korelasi dengan faktor eksposi dan kualitas berkas sinar-X. Resolusi spasial tertinggi yang didapatkan pada penelitian ini adalah 2.57 lp/mm. Sementara itu, SDNR merupakan parameter kuantitatif dari kualitas citra yang dihasilkan. Pengukuran SDNR menunjukkan bahwa kualitas citra memiliki korelasi linear dengan kualitas berkas sinar-X. Semakin tinggi kualitas berkas sinar-X maka kualitas citra yang dihasilkan juga akan semakin tinggi. Studi ini menunjukkan perlunya penelitian lebih lanjut mengenai analisa kualitas sistem pencitraan sinar-X dengan fantom in-house untuk memudahkan uji kontrol kualitas.

A quality control is needed to determine the quality of the X-ray imaging system. A good quality in X-ray imaging system will produce a good image quality according to the principle of ALARA (as low as reasonably achievable). This study was conducted to analyze quality control tests using in-house phantom. Modulation Transfer Function (MTF) dan Signal Difference to Noise Ratio (SDNR) are used as representative parameters of quality of the X-ray imaging system and image quality. MTF is a performance parameter of an X-ray imaging system. Research shows that MTF has no correlation with the exposure factors and beam quality. The highest spatial resolution obtained in this study was 2.5740 cycles/mm. Meanwhile, SDNR is a quantitative parameter of the image quality produced. SDNR measurements show that image quality has a linear correlation with the beam quality. If the X-ray beam quality increased, the image quality will also be higher. This study shows the need for further research on the quality analysis of X-ray imaging systems with in-house phantom to facilitate quality control testing."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2021
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Abdullah Riza Shahab
Depok: Universitas Indonesia, 1994
S28213
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
cover
Dwi Bondan Panular
"Tesis ini membahas tentang perbedaan hasil pengukuran keluaran linac precise system di RSPAD Gatot Soebroto menggunakan detektor matriks PTW dan fantom air, untuk sinar-x pengukuran dilakukan pada lapangan 10 x 10 cm2 dengan SSD 100 cm sedangkan untuk elektron menggunakan aplikator 10 x 10 cm2 dengan SSD 95 cm, dosis yang diberikan 1 Gray (100 MU) pada kedalaman maksimum. PDD untuk sinar-x dan elektron yang dihasilkan dari pengukuran detektor matriks memiliki rentang yang lebih pendek pada daerah kedalaman maksimum dibandingkan dengan hasil pengukuran menggunakan fantom air, dengan rentang perbedaan 4 mm ? 5 mm untuk sinar x dan 3 mm ? 6 mm untuk elektron. Sedangkan profil dosis untuk berkas sinar-x antara detektor matriks dengan fantom air memiliki kesesuaian pada daerah lapangan penyinaran dengan perbedaan kurang dari 2 %. Untuk berkas elektron terjadi perbedaan yang signifikan dengan bertambahnya kedalaman, sehingga dapat disimpulkan bahwa detektor matriks dapat digunakan untuk verifikasi penyinaran pada daerah target volume penyinaran (Gross Tumour Volume/GTV) tetapi kurang baik untuk daerah organ sekitarnya (Organ at Risk/OAR). Detektor matriks lebih baik apabila digunakan untuk sinar-x, tetapi kurang baik digunakan untuk elektron.

This thesis discusses about output differences of Elekta Precise linac treatment system on Gatot Subroto Army Hospital between the use of matrix detector and water phantom, for x-ray measurement performed on 10 x 10 cm2 field size with a SSD 100 cm, as well as electron measurement using the applicator 10 x 10 cm2 with SSD 95 cm, both on the given dose of 1 Gray (100 MU) in the maximum depth. PDD for x-rays and electrons from the measurement of the matrix detector has shorter range in comparison to the maximum depth of measurement results with the water phantom. The range of difference is found to be 4 mm - 5 mm for x-rays and 3 mm - 6 mm for the electrons. Dose profile for x-ray measurement using the matrix detector is having compatibility with water phantom measurement at the irradiation field, with the difference found to be less than 2%. For the electron beam, significant difference occurs with increasing depth, leading to the conclusion that the matrix detector can be used to verify radiation on the Gross Tumour Volume (GTV), while being not good enough for the Organ at Risk (OAR). The matrix detector is better used for x-rays measurement, with relatively poor compatibility for electron measurement.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
T31257
UI - Tesis Open  Universitas Indonesia Library
cover
Universitas Indonesia, 1995
S28302
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>