Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 8499 dokumen yang sesuai dengan query
cover
Universitas Indonesia, 2004
S28833
UI - Skripsi Membership  Universitas Indonesia Library
cover
Universitas Indonesia, 2004
S28811
UI - Skripsi Membership  Universitas Indonesia Library
cover
Universitas Indonesia, 1995
S28355
UI - Skripsi Membership  Universitas Indonesia Library
cover
Detin Audriyanti
"Telah dilakukan pengukuran pola difraksi sinar-X baja karbon rendah tipe SPCE yang biasa digunakan untuk rangka depan truk Mercedes Benz. Hasil refinement yang dilakukan dengan perangkat lunak GSAS memperlihatkan bahwa kristalnya berstruktur kubus-BCC, grup ruang tetragonal Im3m dengan parameter kisi a, b dan c 2,864(1) A; red jf = 1,530; Rp = 0,1041 dan Rwp - 0,1344 dengan jumlah variabel 14. Hasil analisis kerapatan elektron dalam bahan dengan sintesis difference Fourier memperlihatkan bahwa ada konsistenst pengukuran antara kerapatan elektron dengan parameter struktur kalkulasi, dengan nilai Ap max. dan A/7 min. masing-masingnya 1.094 e A'3 dan-3.304 e A'3.

The X-ray diffraction measurement of low carbon steel SPCE-type, which is usually used for front panel of Mercedes Benz truck construction, is reported. Studies and treatments of this work by using the crystallographic software package GSAS confirm that the crystals have cubic-BCC structure, space group tetragonal Im3m, a, b and c = 2.864(1) A, red_/ = 1.530 Rp = 0.1041 and Rwp = 0.1344 with 14 refined variables. Further studies on electron density of this low carbon steel with difference Fourier synthesis show that the calculated structural parameters are consistent with the electron density measurement with max. A/7 and min. A/> 1.094 e A"3 and -3.304 e A" J respectively."
1999
JIRM-1-3-Des1999-14
Artikel Jurnal  Universitas Indonesia Library
cover
Universitas Indonesia, 2000
S28513
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
cover
cover
Simanungkalit, Erlin Ingrina
"Telah dilakukan kalibrasi film Gafchromic XR-RV3 yang dilakukan di Secondary Standard Dosimetry Laboratory (SSDL) BATAN untuk pengukuran dosis kulit pasien selama prosedur intervensional dipandu fluoroskopi. Film dikalibrasi di udara dan di fantom dengan dosis penyinaran 1, 5, 10, 15, 50, 100, 200, dan 300 cGy pada kualitas berkas 70, 80, 90 dan 100 kV. Persamaan faktor kalibrasi dihasilkan dari grafik hubungan nilai kerapatan optik (OD) dengan dosis. Hasil dari pengukuran faktor kalibrasi di udara dan di fantom merupakan persamaan polinomial orde kelima dengan R=1. Dalam penelitian ini juga dilakukan komisioning scanner Perfection V700 di Laboratorium Fisika Medis dan Biofisika yang bertujuan untuk menguji konsistensi scanner, homogenitas scanner, homogenitas film dan suhu ruang penyimpanan film, serta menentukan faktor fading film.
Hasil penelitian menunjukkan bahwa film memiliki komposisi yang tersebar merata pada setiap lapisannya. Berdasarkan respon scanner disarankan untuk melakukan pemindaian pada bagian pusat bedscanner namun tidak disarankan untuk melakukan pemindaian secara berulang. Selama penyimpanan dan proses pembacaan film sebaiknya suhu ruangan dijaga konstan. Berdasarkan lama waktu pemindaian film selama 72 hari, diperoleh laju penurunan nilai pixel film yaitu 314.3 pixel/pekan serta dihasilkan faktor koreksi fading y = -0.002x + 4.701 dengan R2=0.997, sebagai kompensasi waktu pemindaian yang berbeda.

Calibration of Gafchromic XR-RV3 film has been done at Secondary Standard Dosimetry Laboratory (SSDL) BATAN for measurement of patient skin dose during fluoroscopically guided interventional procedures. The film was calibrated free-in-air and on-phantom with exposure doses of 1, 5, 10, 15, 50, 100, 200 and 300 cGy at four x-ray beam qualities of 70, 80, 90 and 100 kV. Calibration factor function was generated from the graph equation between the optical density (OD) and doses. The resulted calibration factor free-in-air and on-phantom were defined in fifth order polynomial function with R=1. In this study commissioning perfection V700 scanner at the Laboratory of Medical Physics and Biophysics which aimed for consistency testing of scanner, the homogeneity of scanner, the homogeneity of film, and the temperature during storage, as well as determined the fading factor of film, was also performed.
The results shows that the composition of film layer was spread equally. Based on the response of scanner, it is recommended scan at center of flatbed but not recommended to perform repeatedly scanning. The room temperature during storage and the process of film reading should be kept constantly. Based on 72 days of the film scanning time, the decrease rate of film pixel value is 314.3 pixel/week and fading correction factor is in term of y = -0.002x + 4.701 with R2=0.997 to compensate reading time variation.
"
Depok: Universitas Indonesia, 2013
S53482
UI - Skripsi Membership  Universitas Indonesia Library
cover
Yohana
"Pemantauan dosis pada pekerja radiasi diperlukan untuk memastikan dosis yang diterima tidak melebihi batas aman yang telah ditetapkan oleh BAPETEN. Dosimeter Termoluminesensi (TLD) seringkali digunakan untuk pemantauan dosis pekerja radiasi. Sebelum digunakan, TLD perlu dikalibrasi dengan suatu sumber radiasi untuk memastikan TLD dapat memberikan hasil pengukuran yang akurat. Salah satu faktor yang mempengaruhi akurasi pengukuran TLD adalah energi. Ketergantungan respons TLD terhadap energi menyebabkan pemilihan sumber radiasi yang tepat untuk kalibrasi TLD perlu diperhatikan. Penelitian ini mengevaluasi respons TLD LiF:Mg,Ti terkalibrasi sumber 137Cs yang digunakan pada rentang energi sinar-X diagnostik menggunakan simulasi Monte Carlo. Evaluasi respons TLD terhadap energi dilakukan menggunakan perhitungan spektrum energi dengan variasi tegangan tabung 60 kV sampai 100 kV, dengan interval 10 kV, dan arus tabung 20 mAs. Hasil penelitian menunjukkan bahwa perhitungan spektrum energi dengan simulasi Monte Carlo dapat digunakan untuk mengestimasi nilai dosis serap dan mengevaluasi respons TLD terhadap energi dengan hasil respons relatif terhadap sumber 137Cs yang diperoleh pada penelitian ini berada pada rentang 1,33 sampai 1,37. Hasil ini menunjukkan bahwa penggunaan sumber 137Cs untuk kalibrasi TLD merupakan pilihan yang kurang tepat dan diperlukan penggunaan sumber radiasi lain untuk mengkalibrasi TLD yang digunakan pada rentang energi sinar-X diagnostik.

Dose monitoring for radiation workers is essential to ensure that the received dose does not exceed the safety limits set by BAPETEN. Thermoluminescent Dosimeters (TLDs) are commonly used for personal dose monitoring. Before use, TLD must be calibrated with a radiation source to guarantee accurate measurement results. Accurate measurements using TLD are essential for dose monitoring. The energy of the radiation is one of the factors affecting the accuracy of TLD measurement. Because TLD response depends on energy, choosing the correct radiation source for calibration is important. This study evaluates the response of LiF:Mg,Ti TLD calibrated with 137Cs source used in the diagnostic X-ray energies using Monte Carlo simulations. The evaluation of TLD response was determined using energy spectrum calculations at tube voltage variations from 60 kV to 100 kV, in 10 kV increments, and a tube current of 20 mAs. The results indicate that energy spectrum calculations can be used to estimate absorbed dose and evaluate TLD response to energy. The relative response to the 137Cs source obtained in this study was between 1.33 and 1.37. These results show that using 137Cs source for calibration is not the optimal choice, and an alternative radiation source is needed for calibrating TLD used in the diagnostic X-ray energy range."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>