cover
Wiwid Wicaksono
"Simulasi Pengukuran Treatment Planning System (TPS) menggunakan software ISIS berbasis Operting system LINUX, dan Pengukuran Dosis menggunakan Pesawat Cobalt-60 dengan Detektor bilik Ionisasi farmer 2571 menggunakan Phantom Air berukuran 32 x 32 x 32 cm3 dosis Referensi sebesar 1 Gy pada kedalaman 5 cm dari permukaan. Teknik Source Axis Distance (SAD) pada jarak 80 cm dengan variasi Luas Lapangan 5 x 5 cm2, 10 x 10 cm2,15 x 15 cm2 (untuk lapangan terbuka), 15 x 10 cm2 (menggunakan wedge) dan Variasi kedalaman 2,5 cm, 5 cm, 10 cm, menghasilkan pengukuran distribusi dosis tidaklah beraturan, khususnya untuk posisi off axis, sehingga mutlak diperlukan simulasi pada TPS untuk perhitungan setiap dosis.

Treatment Planning System (TPS) measurement simulation uses LINUX based Operating System ISIS software, and Dosage Measurement of Cobalt-60 instrument with Farmer 2571 Ionization Chamber Detector uses the Phantom Air measuring 32 x 32 x 32 cm3 with 1 Gy reference dosage at 5 cm depth from surface. Source Axis Distance (SAD) technique at a distance of 80 cm with Field Size variations of 5 x 5 cm2, 10 x 10 cm2, and 15 x 15 cm2 (all for open field), and 15 x 10 cm2 (using wedge) and depth variations of 2.5 cm, 5 cm and 10 cm provides unconsider measurement then TPS Simulation very important every dosis calculation."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2002
S28577
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
Intan Apriliani Syaridatul Mu`minah
"ABSTRAK
DSSuperDose v.1.0 merupakan sebuah in-house Treatment Planning System (TPS) yang dikembangkan oleh Laboratorium Fisika Medis dan Biofisika (LFMB) Universitas Indonesia sebagai suatu perangkat lunak perencanaan terapi pesawat teleterapi cobalt-60. Validasi in-house TPS menjadi parameter penting dalam prosedur jaminan kualitas suatu perangkat lunak perencanaan radioterapi. Verifikasi perhitungan manual, perbandingan dengan ISIS TPS, dan pengukuran dosis serap untuk berbagai kondisi berkas dilakukan terhadap tiga unit pesawat teleterapi cobalt-60. Pengukuran dosis serap dilakukan dengan teknik penyinaran SSD tetap, menggunakan detektor bilik ionisasi di titik pengukuran pada sumbu pusat berkas pada media fantom air. Pengolahan data dan evaluasi dilakukan berdasarkan rekomendasi IAEA dalam TRS 430. Performa in-house TPS optimal untuk memberikan perencanaan terapi teknik SSD tetap pada kondisi berkas terbuka dan penggunaan tray yaitu untuk kedalaman hingga 10 cm (≤ 10 cm), dan ukuran lapangan antara 5×5 hingga 20×20 cm2, sementara untuk penggunaan wedge adalah ukuran lapangan yang lebih kecil dari ukuran dimensi fisik wedge. Perhitungan waktu penyinaran oleh in-house TPS juga menunjukkan kesesuaian yang cukup baik terhadap perhitungan waktu penyinaran oleh ISIS TPS yaitu mencapai 96 %. Dengan demikian, in-house TPS ini sudah cukup akurat sebagai suatu perangkat lunak perencanaan terapi. Akurasi perhitungan in-house TPS dipengaruhi data masukan (input) berkas TPS yang digunakan sebagai basic beam data, dan algoritma perhitungan dalam TPS

ABSTRACT
DSSuperDose v.1.0 is an in-house Treatment Planning System (TPS) developed by Medical Physics and Biophysics Laboratory (LFMB) University of Indonesia as a treatment planning software for cobalt-60 teletherapy unit. Performance validation of TPS calculation is an essensial part in quality assurance (QA) of computerized planning systems for radiotherapy. Verification through manual calculations, comparison to ISIS TPS, and measurements of absorbed dose for varied beam conditions was performed with three teletherapy units. Absorbed dose were measured at central beam axis with an ionization chamber in water phantom. Data evaluation based on IAEA recommendation in TRS 430. In-house TPS gives optimal planning for open and tray beam conditions with depth of isocenter less than 10 cm (≤ 10 cm), and field size 5×5 until 20×20 cm2, while for wedge beam conditions with field size less than the physical size of wedge. Comparison of in-house TPS and ISIS TPS demonstrated a good match of 96 %. From the results, it is concluded that in-house TPS is accurate for treatment planning software of radiotherapy. Accuration of in-house TPS affected by basic beam datas, and calculation algorithm"
2015
S60175
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rico Adrial
"Tesis ini membahas tentang penggunaan Treatment Planning System (TPS) PRISM pada kasus kanker payudara menggunakan unit terapi Elekta di RSPAD Gatot Soebroto. Berkas elektron biasanya digunakan setelah pembedahan untuk pengobatan kanker payudara sebagai dosis tambahan. Pengukuran dosis dengan energi 8 MeV dan 10 MeV serta lapangan aplikator 6 x 6 cm2, 10 x 10 cm2, 14 x 14 cm2 dan 20 x 20 cm2 disimulasikan sebagai beam data pada PRISM. Beam data unit terapi SL20B merupakan bawaan pada piranti lunak PRISM yang akan dijadikan sebagai acuan kalkulasi. Dosis pada water phantom, inhomogenity phantom dan hasil simulasi CT Scan pasien kanker payudara dianalisis secara 1D berupa PDD, 2D berupa kurva isodosis dan 3D berupa Dose Volume Histogram. Distribusi dosis yang dikalkulasi dengan menggunakan TPS PRISM berbeda dengan hasil TPS ISIS. Hal ini karena adanya koreksi dari densitas jaringan (inhomogenitas) pada TPS PRISM sedangkan pada TPS ISIS tidak memperhitungkan hal tersebut. Beberapa deviasi distribusi dosis bernilai sangat besar antara TPS ISIS dan TPS PRISM. Deviasi melebihi 5% terjadi saat energi 8 MeV mulai dari kedalaman 2.3 cm dan 10 MeV mulai dari kedalaman 2.8 cm.

This thesis discusses about the utilization of PRISM Treatment Planning System (TPS) in the case of breast cancer using Elekta therapy unit at RSPAD Gatot Soebroto. Treatment option by using electron beam is always done after surgery as booster doses. Dose measurements with linac energy 8 MeV and 10 MeV and field sizes 6 x 6 cm2, 10 x 10 cm2, 14 x 14 cm2 and 20 x 20 cm2 were simulated as beam data on PRISM. Therapy unit SL20B beam data are innate in software PRISM that will be used as reference calculations. Doses on water phantom, inhomogenity phantom and the CT scan simulation for breast cancer patient were analyzed in form of PDD for 1D, isodosis curve for 2D and Dose Volume Histogram for 3D. The result from PRISM TPS and ISIS TPS are different because the correction factors of inhomogenity are not included in ISIS TPS. Some deviations of dose distribution from TPS ISIS and TPS PRISM are very high. Deviation larger than 5% started from 2.3 cm depth for 8 MeV and 2.8 cm for 10 MeV."
Depok: Universitas Indonesia, 2013
T38762
UI - Tesis Membership  Universitas Indonesia Library
cover
cover
Suwandi
"Treatment Planning System (TPS) merupakan modalitas penting yang menentukan outcome radioterapi. TPS memerlukan input beam data yang diperoleh melalui komisioning yang panjang dan berpotensi terjadi kesalahan. Kesalahan pada tahap ini mengakibatkan terjadinya kesalahan sistematis yang berimplikasi pada kesalahan dosis yang diterima target tumor. Tujuan penelitian ini adalah melakukan verifikasi dosimetri TPS untuk mengetahui rentang deviasi antara dosis hasil perhitungan TPS dengan dosis hasil pengukuran di dalam fantom inhomogen. Penelitian menggunakan obyek uji berupa fantom CIRS model 002LFC yang merepresentasikan thoraks manusia dengan mensimulasikan seluruh tahapan radioterapi berkas eksternal. Fantom dipindai menggunakan CT Scanner, membuat dan mengevaluasi 8 kasus uji yang hampir sama dengan kondisi di praktek klinik, diujikan pada empat center radioterapi. Pengukuran dosis titik menggunakan bilik ionisasi 0,6 cm3. Dosis hasil perhitungan TPS dan dosis hasil pengukuran di fantom dibandingkan.
Hasil penelitian menunjukkan bahwa sebagian besar deviasi pada seluruh kasus uji di keempat center radioterapi berada di dalam rentang toleransi dengan rata-rata deviasi pada center 1, 2, 3 da 4 berturut-turut sebesar -0.17 ± 1.59 %, -1.64 ± 1.92 %, 0.34 ± 1.34 % dan 0.13 ± 1.81 %. Besarnya deviasi di luar rentang toleransi umumnya ditemukan pada kasus uji menggunakan alat pembentuk berkas, menggunakan berkas tengensial dan pada material inhomogen. Dosis hasil pengukuran pada titik nomor 10 (material ekuivalen tulang) pada umumnya cenderung lebih tinggi daripada dosis hasil perhitungan. Kesimpulan dari penelitian ini adalah semua unit TPS menunjukkan performa yang baik. Algoritma Superposisi memiliki performa kurang baik dibandingkan dengan algoritma Konvolusi maupun Analytic anisotropic algorithm (AAA) dengan rata-rata deviasi berturut-turut sebesar -1.64 ± 1.92 %, -0.17 ± 1.59 % dan -0.27 ± 1.51 %.

The Treatment Planning System (TPS) is an important modality that determines radiotheraphy outcome. TPS requires input beam data obtained through a long commissioning and potentially error occured. Error in this step may result in systematic error which have implication to inacurrate dose in tumor target. The aim of this study to verify the TPS dosimetry to know deviation range between calculated and measurement dose in inhomogen phantom. This research used CIRS phantom 002LFC representing the human thorax and simulated all external beam radiotherapy stage. Phantom was scanned using CT Scanner and planned 8 test case that were similiar to those in clinical practice situation was made, tested in four centers of radiotheraphy. Dose measurement using 0,6 cc ionization chamber. Calculated and measured dose were compared.
The results of this study showed that generally, deviation of all test case at all four centers was within agreement criteria with average deviation about -0.17 ± 1.59 %, -1.64 ± 1.92 %, 0.34 ± 1.34 % dan 0.13 ± 1.81 %. The deviation out of tolerance commonly were found on test case using beam modifier, tangential incidence beam and at inhomogen material. Generally, measured dose at point 10 (bone equivalent material) tend to be larger than the calculated dose.The conclusion of this study was all TPS involved in this riset showed good performance. The Superposition algorithm showed rather poor performance than either Analytic Anisotropic Algoritm (AAA) and Convolution algorithm with average deviation about -1.64 ± 1.92 %, -0.17 ± 1.59 % dan -0.27 ± 1.51 % respectively.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2016
T45644
UI - Tesis Membership  Universitas Indonesia Library
cover
Agung Nugroho Oktavianto
"Telah dilakukan pengukuran relatif untuk mengetahui perubahan parameter dosimetri berkas sinar X 6 MV pada sumbu vertikal/sumbu normal terhadap permukaan dengan variasi sudut gantry 0º, 15º, 30º, 45º, dan 60º dari pesawat Linac Electa Precise 5991 milik Rumah Sakit Hasan Sadikin Bandung dengan luas lapangan 10x10 cm2, 15x15cm2 , dan 20x20 cm2. Rekonstruksi TPS dan simulasi Monte Carlo menggunakan parameter yang sama dengan pengukuran.
Hasil penelitian menunjukkan bahwa terjadi perubahan kedalaman maksimum yang dipengaruhi kenaikan luas lapangan dan sudut gantri dengan deviasi terbesar -33,3% pada luas lapangan 20x20 cm2 dan sudut gantri 600 terhadap luas lapangan 10x10 cm2 dan sudut gantri 00. Terjadi titik belok pada sumbu vertikal yang disebabkan karena adanya kemiringan permukaan, yang menurun dengan kenaikan sudut gantri. Hasil rekonstruksi TPS menunjukkan kesesuaian terhadap hasil pengukuran pada titik PDD maksimum, kedalaman 5 cm dan 10 cm, berbeda dengan hasil perhitungan Monte Carlo yang relatif lebih tinggi. Demikian pula untuk titik-titik di luar sumbu vertikal/sumbu normal.
Rekonstruksi TPS mempunyai deviasi < 2%, sedangkan perhitungan Monte Carlo mempunyai deviasi < 2% hanya pada daerah kuadran (+). Pengamatan titik-titik pada sumbu utama berkas hanya dilakukan dengan rekonstruksi TPS karena keterbatasan kemampuan alat, hasil penelitian menunjukkan bahwa PDD pada kedalaman dmax, 5 cm, dan 10 cm pada sumbu utama untuk sudut gantri 150 sampai dengan 600 cenderung menurun untuk ukuran lapangan yang sama demikian juga pada daerah kuadran (+).

Relative meauserement for change of dosimetry parameters X ray beam 6 MV Linac Electa Precise 5991 property of Hasan Sadikin Bandung?s hospital at the vertical central line from surface with incident obliquity 0º, 15º, 30º, 45º, 60º and 10x10 cm2, 15x15cm2, 20x20 cm2 field has been done. As in Reconstruction of TPS and Monte Carlo simuation with the same parameters measurement have been conducted.
The result of the experiment showed the change of maximum depth because of the increase in the filed dan angle of gantri with deviation -33% at the 20x20 cm2 field and 600 angle of gantry to 10x10 cm2 field and 00 angle of gantry . To happened point of to drop at the vertical central line because change sloping field to surface and drop on with increase of angle?s gantry.
The result of reconstruction of TPS to show not different with meaurement at point máximum PDD, 5 cm depth, 10 cm depth, point at off verical line, Monte Carlo calculation is higher. In all oint of reconstruction?s TPS has deviation < 2%, but calculation Monte Carlo just happen at the kuadran (+) area. Observation at the point in the central beam just done with reconstruction of TPS because the equipment capability limitation in the measurement, PDD at the depth of dmax, 5 cm, 10 cm, 150 to 600 angle of gantry in the central beam tilted decrease for the same field and kuadran (+) area too.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
T29077
UI - Tesis Open  Universitas Indonesia Library
cover
cover
Misjuherlina
"ABSTRAK
Brakhiterapi high dose rate (HDR) Ir-192 dengan menggunakan aplikator
silinder pada umumnya dilakukan pada pasien kanker endometrium sebagai
booster atau tambahan pada radioterapi eksternal. Dalam penelitian ini telah
dilakukan simulasi brakhiterapi menggunakan aplikator silinder berdiameter
20 mm, panjang 60 mm, dalam medium 130 mm fantom padat ekuivalen air, dan
sumber tunggal sekitar 7.3 Ci diletakkan pada pertengahan silinder. Titik
pengukuran dipilih berjarak 15, 16, 17, 18, 19, 20, 22, dan 25 mm dari sumber.
Selain itu dilakukan pula simulasi dengan multi sumber, dengan interval jarak
antar sumber 2,5 mm, 5 mm, 10 mm, 15, mm, 20 mm, 25 mm, dan 30 mm, untuk
memperoleh informasi distribusi dosis pada medium di sekitar aplikator. Setiap
simulasi memberikan dosis 700 cGy pada daerah 15 mm dari sumber. Film
dibaca dengan scanner Epson 1000 XL, dan dievaluasi dengan program image j.
Distribusi dosis dibuat dengan mengacu pada kurva isodosis 700 cGy sebagai
100%. Hasil pengukuran film gafChromic kemudian digunakan untuk verifikasi
treatment planning system (TPS) Plato dalam kalkulasi dosimetri dan penentuan
distribusi dosis. Hasil pengukuran dengan sumber tunggal menunjukkan
hubungan antara dosis dengan jarak dari sumber ke titik sepanjang sumbu utama
dalam bentuk kurva yang berimpitan dengan kurva hasil kalkulasi TPS. Perbedaan
dosis hasil pengukuran pada 8 titik tidak lebih dari 2% dari hasil kalkulasi TPS.
Adapun simulasi dengan multisumber, menghasilkan distribusi dosis dengan
perhatian diberikan pada kurva isodosis 100%, 75%, 50%, dan 25%. Untuk
keperluan evaluasi selanjutnya, jarak antara sumber dengan keempat kurva
isodosis dinyatakan sebagai nilai h. Pada umumnya nilai h hasil pengukuran tidak
berbeda signifikan dibanding dengan hasil kalkulasi TPS, karena berbeda lebih
dari 5 mm. Khusus untuk kurva isodosis 100%, ditemui bergelombang pada
penggunaan sumber mulai dengan interval 20 mm, dan tampak pada hasil
pengukuran maupun kalkulasi TPS.

ABSTRACT
Brakhiterapi high dose rate (HDR) Ir-192 using applicator cylinder is generally
performed in patients with endometrium cancer as an additional booster or
external radiotherapy. In these studies have been done using simulation
brakhiterapi applicator cylinder diameter of 20 mm, 60 mm long, 130 mm in the
medium of water equivalent solid phantom, and a single source of about 7.3 Ci
cylinder is placed in the middle. Selected measurement points is 15, 16, 17, 18,
19, 20, 22, and 25 mm from the source. In addition it also conducted simulations
with multi-source, the distance between the source interval 2.5 mm, 5 mm, 10
mm, 15 mm, 20 mm, 25 mm, and 30 mm, to obtain information on the medium
dose distribution the applicator. Each simulation gives 700 cGy dose at 15 mm
from the source region. Films read by a scanner Epson 1000 XL, and evaluated
with image j program. Dose distributions were made with reference to 700 cGy
isodose curve as 100%. GafChromic film measurement results are then used to
verify treatment planning system (TPS) Plato in dosimetry calculations and the
determination of the dose distribution. The results of measurements with a single
source single shows the relationship between the dose with distance from the
source to titk along the major axis in the form of curves coincident with TPS
calculations yield curve. Differences in dose measurements at 8 point no more
than 2% of the calculated results TPS. The simulation with multisumber, produce
distribution dois with attention given to the 100% isodose curve, 75%, 50%, and
25%. For the purpose of further evaluation, the distance between the four sources
with isodose curves were expressed as h. In general, the value of h measurement
results do not differ significantly compared with the calculated results TPS,
because differ by more than 5 mm. Especially for the 100% isodose curve, wavy
encountered in the use of sources starting with the interval of 20 mm, and looks at
the results of measurements and calculations TPS."
Universitas Indonesia, 2013
T35577
UI - Tesis Membership  Universitas Indonesia Library