Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 36896 dokumen yang sesuai dengan query
cover
Suryadharma
"Laporan tugas akhir ini membahas bagaimana cara membuat suatu system distribusi air bersih dengan kontrol elektro mekanis. Hal ini sangat penting karena air bersih merupakan suatu kebutuhan dasar yang menunjang seluruh aktifitas manuasia yang saat ini sudah sangat sulit untuk ditemukan dikota ? kota besar. Oleh karena itu diperlukan suatu sistem yang bisa mengatur distribusi air bersih sehingga pemanfaatannya bisa dilakukan secara efisien. Dengan sistem disribusi air bersih ini diharapkan bisa menjaga kestabilan alam ( siklus air ) dan bias menekan biaya untuk penggunaan air bersih.

This final job report is studying about how to planning a clean water distribution system with electro mechanic control. This is very important because clean water is a primary requirement that support all human activity that very difficult to find in big cities at this time. Therefore it is need system that can arrange clean water distribution so that we can use it efficiently. We hope with this clean water distribution system we can take care with nature stability ( water cycle ) and can save our money for clean water consumtion."
Depok: Fakultas Teknik Universitas Indonesia, 2008
S52316
UI - Skripsi Open  Universitas Indonesia Library
cover
Aisya Zahra
"

Distribution Requirement Planning (DRP) merupakan metode untuk menangani persediaan dalam suatu jaringan distribusi yang bertujuan untuk memenuhi kebutuhan permintaan serta menentukan kebutuhan untuk mengisi kembali persediaan pada masing-masing pusat distribusi. Permasalahan yang terjadi pada sistem distribusi PT XYZ, produsen serta distributor air minum dalam kemasan, muncul akibat adanya selisih antara permintaan dengan pengiriman aktual yang dilakukan kepada agen. Selain itu, perusahaan juga mengalami pengeluaran biaya distribusi yang tinggi. Kedua permasalahan tersebut terjadi karena adanya fluktuasi permintaan produk dan belum adanya sistem distribusi yang baik. Sistem distribusi yang baik mampu melakukan peramalan permintaan serta melakukan perencanaan persediaan guna memenuhi kebutuhan konsumen per periodenya. Metode yang tepat digunakan dalam menyelesaikan permasalahan ini adalah DRP, dengan tahapan pertama yaitu melakukan peramalan permintaan enam periode kedepan dengan hasil yang paling akurat yaitu pada peramalan metode linear. Kemudian dilanjutkan dengan penentuan metode lot sizing dalam pembuatan DRP yaitu metode Lot for Lot (LfL) dan Least Unit Cost (LUC) dengan total biaya terendah sebesar Rp115,605,334 selama periode enam bulan. Penerapan metode DRP pada kedelapan agen mampu mengurangi total biaya yang dikeluarkan sebesar Rp74,388,066 atau sebesar 39,15%. Selain itu, permintaan konsumen dari masing-masing agen juga dapat terpenuhi pada tiap periodenya.


Distribution Requirement Planning (DRP) is a method for handling inventory procurement in a distribution network to determine the demands and needs to replenish at each distribution center. Problems that occur in the distribution system of PT XYZ, a bottled water company, arise due to differences between customer demand and the actual deliveries made towards agents. Moreover, the company is also facing fairly high distribution costs. Both of these problems are caused by demand fluctuations and a lack of distribution system. A good distribution system is defined by the capability to forecast demands and plan inventories to meet customer needs. The method used to solve the problem is DRP, with the first phase being to forecast the demand for the next six periods with the linear forecasting method that generates the most accurate forecast values. Followed by determining the lot sizing with Lot for Lot (LfL) and Least Unit Cost (LUC) methods that produce the lowest total cost of Rp115,605,334 over a six-month period. The application of the DRP method to the eight agents was able to decrease the total costs by Rp74,388,066 or 39.15%. Furthermore, the demands from each agent will also be fulfilled for each period.

"
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Prihutami Rista Hermawati
"Rencana Pengembangan Lapangan Migas Terbatas di Blok Tonga oleh PT. Energi Mega Persada Tonga menyebabkan penambahan produksi minyak bumi menjadi1.700 barel minyak per hari. Meningkatnya produksi minyak bumi akan diikuti oleh jumlah produced water yang semakin besar pula mencapai 4.000 barel air per hari. Oleh karena itu, muncul pilihan untuk mendaur ulang produced water menjadi air bersih yang dapat dimanfaatkan untuk kebutuhan nonpotable operasional lapangan seperti flushing toilet, pengairan taman, pencucian alat dan kendaraan. Berdasarkan uji laboratorium dan analisis data sekunder (untuk parameter BOD) didapatkan kualitas produced water dari unit pengolahan eksisting sebagai berikut : BOD 39,46 mg/L ; COD 48 mg/L ; TSS 15 mg/L; TDS 84,1 mg/L; Ammonia 0,06 mg/L ; Phenol < 0,001 mg/L; Sulfida 0,01 mg/L; Pb < 0,023 mg/L; Zn < 0,006 mg/L; Cu < 0,006 mg/L; serta minyak dan lemak sebesar < 1,13 mg/L. Alternatif teknologi daur ulang yang dianalisis meliputi pengolahan dengan chemical precipitation, pengolahan membran dengan reverse osmosis, dan pengolahan biologis dengan fitoremediasi wetland menggunakan tanaman akar wangi. Target kualitas air daur ulang mengacu pada Peraturan Pemerintah No.82 tahun 2001 peruntukkan air kelas 2. Pemilihan teknologi pengolahan lanjutan produced water dilakukan dengan metode pembobotan yang memperhitungkan parameter removal kontaminan dan biaya, serta mempertimbangkan luasan lahan yang diperlukan dan dampak lingkungan. Dari perhitungan yang dilakukan, unit pengolahan lanjutan yang terpilih adalah fitoremediasi wetland menggunakan tanaman akar wangi. Melalui pengolahan tersebut, didapatkan kualitas efluen berupa BOD 2,34 mg/L ; COD 4,8 mg/L ; TSS 1,5 mg/L; TDS 84,1 mg/L; Ammonia 0,06 mg/L ; Phenol 0,0007 mg/L; Sulfida 0,002 mg/L; Pb 0,0067 mg/L;Zn 0,0006 mg/L; Cu 0,0006 mg/L; serta minyak dan lemak sebesar 0,098 mg/L.Total biaya investasi awal yang diperlukan sebesar Rp 1.320.855.290,00.

Development Plan of Oil & gas Limited Block in Tonga by PT Energy Mega Persada Tonga will cause the additional of petroleum production up to 1.700 barrels of oil per day. The increased petroleum production will be followed by the number of produced water which are getting bigger too until reached 4.000 barrels of water per day. Therefore, it appears the option to recycle produced water into clean water that can be used for the needs of the operational field as nonpotable needs, as flushing toilets, watering the garden, and also washing equipment and vehicles. Based on laboratory tests and analysis of secondary data (for parameters BOD), the quality of produced water from the existing processing units as follows: BOD 39,46 mg/L; COD 48 mg/L; TSS 15 mg/L; TDS 84,1 mg/L; Ammonia 0.06 mg/L; Phenols < 0,001 mg/L; Sulfide 0,01 mg/L; Pb < 0,023 mg/L;Zn < 0,006 mg/L; Cu < 0,006 mg/L; and oil and grase < 1,13 mg/L. Alternative recycling technology which is analyzed covers chemical precipitation, reverse osmosis, and wetland plant use V. zizanioides. The target of the quality of water recycling are referenced to PP No.82/2001 designated class 2 water. Selection of advanced processing technology produced water is done by weighting method that takes into account parameters of contaminant removal and costs, as well as considering the land area required and the environmental impact. From the calculation, the advanced processing unit selected is phytoremediation wetland by plants Vetiver. Through the treatment, effluent quality is obtained in the form of BOD 2,34 mg/L ; COD 4,8 mg/L ; TSS 1,5 mg/L; TDS 84,1 mg/L; Ammonia 0,06 mg/L ; Phenol 0,0007 mg/L; Sulfida 0,002 mg/L; Pb 0,0067 mg/L;Zn 0,0006 mg/L; Cu 0,0006 mg/L; also oil and grase 0,098 mg/L. The total cost of the initial investment required of Rp 1.320.855.290.00."
Depok: Fakultas Teknik Universitas Indonesia, 2013
S46706
UI - Skripsi Membership  Universitas Indonesia Library
cover
Alfri Kusnadi
"Sistem distribusi & kontrol adalah bagian yang vital pada fasilitas bawah laut. Sistem distribusi & kontrol berfungsi untuk mendistribusikan pengiriman tenaga listrik, tenaga hidrolik dan injeksi kimia ke fasilitas bawah laut. Dalam masa operasinya, sistem distribusi & kontrol bisa mengalami gangguan apakah berupa kerusakan atau turunnya kinerja sistem tersebut. Pembahasan dalam makalah ini terkait investigasi gangguan pada jalur hidrolik LP2 yang mengirimkan tenaga hidrolik dari Topside ke fasilitas bawah laut. Untuk bisa melakukan investigasi gangguan pada system distribusi & kontrol apakah disebabkan oleh kebocoran ataupun kerusakan, selalu melibatkan penggunaan kapal dan ROV dikarena inspeksi visual dan intervensi terhadap fasilitas bawah laut cuma bisa dilakukan dengan mengandalkan ROV. Persiapan investigasi dilakukan dengan melakukan studi literatur dari dokumen-dokumen yang telah tersedia pada tahap perancangan, pemasangan dan pengujian. Berdasarkan dokumen-dokumen tersebut ditentukan langkah-langkah yang harus dilakukan pada saat investigasi. Langkah-langkah investigasi juga menyesuikan kemampuan dari kapal dan ROV yang tersedia.

Distribution & control systems are critical parts of the subsea facilities. The distribution & control system functions to distribute the delivery of electric power, hydraulic power and chemical injection to the subsea facilities. During operational period, the distribution & control system can experience disruption, whether in the form of damage or a decrease in the system's performance. The discussion in this paper concerns the investigation of disturbances in the LP2 hydraulic line which transmits hydraulic power from Topside to the subsea facilities. In order to be able to investigate disturbances in the distribution & control system, whether caused by leaks or damage, always involves the use of vessel and ROVs since the visual inspections and interventions on underwater facilities can only be done by the ROV. Preparation for the investigation was carried out by conducting a literature study of the documents available at the design, installation and testing stages. Based on these documents, the steps that must be taken during the investigation are determined. Investigation steps also adjust the capabilities of the available ships and ROVs. Details of the leak investigation work are discussed in this engineering report."
Depok: Fakultas Teknik Universitas Indonesia, 2024
PR-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Anton Prayoga
"Di kampung Tanjung Lame, kabupaten Pandeglang, sumber air tanah dari sumur masyarakat sangat asin, sehingga tidak layak untuk dikonsumsi. Salah satu alternatif teknologi yang efisien untuk mengolah air bersih dari sumur air asin adalah sistem filtrasi reverse osmosis (RO). Namun, tekanan yang diperlukan pada sistem filtrasi RO satu tahap konvensional sangat tinggi. Penelitian ini bertujuan untuk merancang sistem filtrasi RO bertahap yang dapat beroperasi pada tekanan rendah. Rancang bangun sistem filtrasi RO dengan konfigurasi hybrid RO/NF permeate staging terbukti mampu menghasilkan air bersih dari sumur air asin. Untuk mendapatkan hasil yang optimum, konfigurasi tersebut dioperasikan pada tekanan RO/NF tahap pertama dan tahap kedua masing-masing 6 dan 3 bar. Pada kondisi operasi optimum tersebut, nilai salt rejection yang dapat dicapai sebesar 97,02% dengan nilai TDS produk air bersihnya sebesar 86 ppm. Nilai water recovery yang dihasilkan sebesar 37% dengan laju alir produk air bersihnya sebesar 1,85 liter/menit. Konsumsi energi spesifik (SEC) sistem filtrasi RO yang dirancang sebesar 1,802 kWh/m3. Nilai SEC dari sistem filtrasi RO yang dirancang dapat diturunkan hingga 58,39% dari nilai SEC RO konvensional satu tahap. Sistem filtrasi RO dengan konfigurasi hybrid RO/NF permeate staging terbukti memiliki kinerja yang lebih baik dibandingkan dengan sistem filtrasi RO konvensional satu tahap.

In Tanjung Lame village, Pandeglang district, groundwater sources from community wells are very salty, so they are not suitable for consumption. One efficient alternative technology for treating clean water from saltwater wells is a reverse osmosis (RO) filtration system. However, the pressure required on a conventional single-stage RO filtration system is very high. The purpose of this study to design a multi-stage RO filtration system that can operate at low pressure. The design of the RO filtration system with a hybrid RO/NF permeate staging configuration has proven to be able to produce clean water from saltwater wells. To obtain optimum results, the configuration is operated at the first and second stage RO/NF transmembrane pressures of 6 and 3 bars, respectively. At the optimum operating conditions, salt rejection that can be achieved is 97,02% with a clean water product TDS value of 86 ppm. Water recovery that can be achieved is 37% with a clean water product flow rate of 1,85 liters/minute. Specific energy consumption (SEC) of the designed RO filtration system is 1,802 kWh/m3. The SEC value of the designed RO filtration system can be reduced to 58,39% from the conventional single-stage RO. RO filtration systems with a hybrid RO/NF permeate staging configuration has proven to have better performance compared to conventional single-stage RO filtration systems."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Fildzah Dhira Lestari
"ABSTRAK
Kebocoran jaringan pipa distribusi air bersih dapat menimbulkan risiko keselamatan air bersih berupa kontaminasi air dan penyebaran penyakit melalui air. Sehingga dalam mendukung, mengevaluasi, dan meningkatkan manajemen keselamatan air pada jaringan pipa distribusi, digunakan metode pendekatan kuantitatif salah satunyaQuantitative Microbial Risk Assessment (QMRA). Penelitian ini bertujuan untuk mengetahui kualitas air bersih terutama parameter E. coli di jaringan pipa distribusi, menganalisis penilaian risiko keterpajanan E. coli O157:H7, mengidentifikasi risiko penilaian efek kesehatan dan menganalisis karakter risiko bakteri tersebut. Metode penelitian menggunakan metode QMRA, yaitu identifikasi bahaya, penilaian paparan, penilaian efek kesehatan dengan model Beta-Poisson, dan karakterisasi risiko. Tahap identifikasi bahaya menetapkan paparan E. coli O157:H7 berasal dari air PDAM, dimana jalur paparannya adalah unboiled water, dengan rute paparan melalui proses menelan akibat aktivitas pemakaian air PDAM sehari-hari. Terdapat dua tipe penggunaan air, yaitu penggunaan air secara langsung dari jaringan pipa distribusi dan air dialirkan menuju tangki air. Identifikasi bahaya dilakukan dengan pemeriksaan kualitas air pada jaringan pipa distibusi, bahwa hasil menunjukkan kualitas air telah memenuhi Peraturan Menteri Kesehatan Republik Indonesia No. 492 Tahun 2010 untuk parameter fisik dan kimia. Namun untuk parameter biologis, konsentrasi E. colimaksimum ditemukan 49 MPN100 mL pada 1 responden (20) yang menggunakan tangki air. Penilaian paparan untuk menentukan dosis paparan akibat E. coli O157:H7 mendapatkan besarnya rata-rata kurang dari 0,01090,0026 organismeL dan 0,01440,0041 organismeL saat pemakaian air minimum dan maksimum. Dosis paparan meningkat pada responden yang menggunakan tangki air sebesar 946 dan 860 saat penggunaan air minimum dan maksimum. Tahap penilaian efek kesehatan menggunakan model Beta-Poisson dengan dan adalah 0,0571 dan 2,2183 mendapatkan bahwa rata-rata probabilitas infeksi harian pada jaringan pipa distribusi PDAM adalah kurang dari adalah 2,800x10-46,723x10-5 dan 3,698x10-41,046x10-4saat pemakaian air minimum dan maksimum. Bagi responden yang menggunakan tangki air, probabilitas infeksi harian meningkat sebesar 876 dan 785 saat penggunaan air minimum dan maksimum. Sehingga, pada tahap karakterisasi risiko, probabilitas infeksi tahunan adalah kurang dari 9,598x10-22,205x10-2 dan 1,236x10-13,127x10-2 saat pemakaian air minimum dan maksimum. Bagi responden pengguna tangki air, probabilitas infeksi tahunan meningkat sebesar 271 dan 204 saat penggunaan air minimum dan maksimum. Karena itu, evaluasi parameter fisik, kimia dan biologi perlu dilakukan berdasarkan waktu dan wilayah untuk meningkatkan performansi IPAB dan keselamatan konsumen.

ABSTRACT
Pipe leakage of clean water distribution network can cause clean water safety risks in the form of water contamination and waterborne disease. So that, in supporting, evaluating, and improving water safety management in distribution pipe network, a quantitative approach is used, which is Quantitative Microbial Risk Assessment (QMRA). This study aims to study the quality of clean water, especially E. coli in distribution pipe network; analyzing the exposure assessment of E. coli O157:H7, identification the risk of health effects assessment and analyzing the risk character. The research method uses QMRA method, namely hazard identification, exposure assessment, health effects assessment with Beta-Poisson model, and risk characterization. Hazard identification determines exposure of E. coli O157:H7 come from PDAM water, which the exposure path is unboiled water, with route of exposure through ingestion due to daily PDAM water usage activities. There are two types of water usage, its water usage directly from water distribution pipe and through water tank. Examining water quality carries out hazard identification, which water quality on the PDAM distribution pipe network has fulfilled the Regulation of the Minister of Health of the Republic of Indonesia No. 492 in 2010 for physic and chemical parameter. However, in biologic parameter, the maximum E. coli concentration was found to be 49 MPN100 mL in 1 respondent (20), who used water tank. Exposure assessment determines the exposure dose of E. coli O157:H7 on clean water distribution pipe network with the averages of doses are less than 0,01090,0026 organismsL and less than 0,01440,0041 organismsL at minimum and maximum of water usage, respectively. The exposure dose increase when the respondent use water tank, its 946 and 860 at minimum and maximum water usage. Health effects assessment usingBeta-Poisson model with and are 0,0571 and 2,2183, respectively. The averages of daily probability of infection on clean water distribution pipe network in PDAM are less than 2,800x10-46,723x10-5 and less than 3,698x10-41,046x10-4 at minimum and maximum of water usage, respectively. Respondent, who use water tank, have increased the daily probability of infection to 876 and 785 at minimum and maximum water usage. So that, in risk characterization, the annual probability of infection are less than 9,598x10-22,205x10-2 and 1,236x10-13,127x10-2 at minimum and maximum of water usage, respectively. For respondent who use water tank, it has increased to 271 and 204 at minimum and maximum of water usage, respectively. Therefore, evaluation in physic, chemical, and biology parameters needs to be done based on time and region to improve WTP performance and consumer safety.
"
2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Erdwin Hendriyanto Saputra
"Air merupakan unsur alam yang sangat penting untuk setiap makhluk hidup. Berdasarkan sumbernya saat ini banyak sumber air permukaan yang telah tercemari maka dari itu perlu adanya pengolahan sebelum menggunakan air permukaan dan salah satu metodenya yaitu filtrasi dengan jenis saringan pasir lambat dikarena berdasarkan beberapa literatur saringan pasir lambat cocok digunakan dengan nilai kekeruhan dibawah 50 NTU. Penelitian ini bertujuan memberikan referensi kepada UI terutama Fakultas Teknik UI terkait dengan unit-unit pengolahan air dan desainnya berdasarkan kualitas sumber air baku yaitu Danau Mahoni UI. Pengolahan air baku berfokus pada unit filtrasi dengan jenis saringan pasir lambat yang bermediakan zeolit dan pasir silika untuk menghilangkan besi dan mangan dengan komposisi 1,2 mg/L dan 1,3 mg/L. Filtrasi diharapkan dapat melayani Fakultas Teknik UI sampai dengan 2042 dan setelah dilakukan proyeksi kebutuhan air bersih pada tahun 2042 dibutuhkan air bersih sebanyak 19,67 L/detik. Pada perancangan unit ini data yang digunakan untuk berasal dari beberapa jurnal seperti nilai ketebalan zeolit 30 cm, silika 60 cm, kecepatan filtrasi 0,2 m/jam, dan efisiensi 95% serta waktu detensi 24 jam dan hasil perhitungan, penulis mendapatkan luas setiap unit yaitu bangunan intake 10,8 m2, bak penghubung 5,4 m2, suction well 7,9 m2, roughing filter 142,56 m2, slow sand filter 532 m2, bak pencuci media 361 m2, desinfeksi 12,96 m2, reservoir 141,12 m2, dan rumah pompa distribusi 9 m2. Berdasarkan hasil studi literatur dan perhitungan yang dilakukan diharapkan air hasil pengolahan dapat memenuhi kualitas air menurut Permenkes RI No 492 tahun 2010.

Water is one of the natural elements that is very important for every living thing. Based on the current sources, many surface water sources have been contaminated and therefore need further treatment before using it. Theres many possible way to treatment surface water and one of the methods is filtration using a slow sand filter because based on some literature, slow sand filters are suitable for use with turbidity values below 50 NTU. This study aims to provide a reference to the University of Indonesia, especially the Faculty of Engineering related to water treatment units and design based on the quality of raw water sources located on Lake Mahoni University of Indonesia. Raw water treatment focuses on filtration units with a type of slow sand filter that provides zeolite and silica sand to remove iron and manganese with a composition of 1.2 mg/L and 1.3 mg/L. This filtration is expected to serve the Faculty of Engineering until 2042 and after projecting, 19,67 L/s of clean water is needed until 2042. In this study, the design of the unit that will be used are intake building, suction well, centrifugal pump, closed transmission line, slow sand filter, disinfection, reservoir, and distribution pump housing. The data used for this design come from several journals such as media thickness, filtration speed, and removal efficiency values ​​with a thickness value of 30 cm zeolite, silica 60 cm, filtration speed 0.2 m/hour, and 95% efficiency and detention time 24 hours. The calculation results show that the area of each unit needed are 10,8 m2 for intake building 5,4 m2 for connecting rods, suction well around 7.9 m2, roughing filter 142,56 m2, slow sand filter around 532 m2, media washing basin around 361 m2, disinfection around 12,96 m2, reservoir around 141,12 m2, and 9 m2 for distribution pump house; and by that the treated water can comply with water quality standards according to the PERMENKES No 492 in 2010."
Depok: Fakultas Teknik Universitas Indonesia, 2020
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Kevin Dristian Dani
"Sistem pendingin kini sangat dibutuhkan untuk menyesuaikan kebutuhan kenyamanan ruangan dan juga akibat dari pemanasan global. Air Conditioning (AC) merupakan salah satu sistem pendingin yang telah digunakan dalam berbagai kebutuhan pendinginan, dalam penggunaannya beberapa AC konvensional menggunakan refrigeran yang masih termasuk dalam golongan halogen dan dapat merusak lapisan ozon. Oleh karena itu, dibutuhkan refrigeran pengganti salah satunya amonia-air yang digunakan dalam sistem pendingin Absoption Chiller. Untuk mengevaluasi kinerja dari sistem pendingin Absoption Chiller dilakukan pemodelan menggunakan metode numerik berupa simulasi pada aplikasi MATLAB. Simulasi disesuaikan dengan pemodelan sistem pendingin Absoption Chiller dengan fluida kerja amonia-air, sistem berpendingin udara pada kondensor dan dengan kapasitas pendinginan 5kW. Penelitian ini berfokus pada sistem kontrol menggunakan metode PI kontrol dari sistem pendingin Absoption Chiller yang mengatur temperatur ruangan dengan mengatur temperature hot water yang memanaskan generator sehingga banyaknya massa dari refrigeran dapat diatur sesuai dengan temperatur ruangan yang diinginkan. Pada sistem pengendalian ini dapat mengubah Temperature Chilled Water Out menjadi 5,9°C, Temperature Chilled Water In menjadi 90,5°C dan Temperature Chilled Water Out menjadi 81,8°C.

The cooling system is now very much needed to adjust the comfort needs of the room and also the consequences of global warming. Air Conditioning (AC) is a cooling system that has been used for various cooling needs, in its use some conventional air conditioners use refrigerants which are still included in the halogen group and can damage the ozone layer. Therefore, a replacement refrigerant is needed, one of which is ammonia-water used in the absorption chiller cooling system. To evaluate the performance of the Absoption Chiller cooling system, modeling is carried out using numerical methods in the form of simulations in the MATLAB application. The simulation is adapted to the modeling of the Absoption Chiller cooling system with ammonia-water working fluid, an air-cooled system in the condenser and with a cooling capacity of 5kW. This research focuses on the control system using the PI control method of the Absoption Chiller cooling system which regulates room temperature by adjusting the temperature of the hot water that heats the generator so that the amount of mass of refrigerant can be adjusted according to the desired room temperature. This control system can change the Temperature Chilled Water Out to 5.9°C, Temperature Chilled Water In to 90.5°C and Temperature Chilled Water Out to 81.8°C."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rizky Ardhy Maulana
"ABSTRAK
Kebocoran pada jaringan pipa distribusi merupakan penyebab utama terjadinya gangguan pelayanan yang dikeluhkan oleh pelanggan PDAM Tirta Patriot, Kota Bekasi, namun, identifikasi masalah desain pada jaringan distribusi merupakan hal mendasar yang harus diketahui, agar penanganan gangguan dapat terjadi secara menyeluruh. Tujuan penelitian ini adalah untuk menganalisa jaringan distribusi air minum eksisting PDAM Tirta Patriot guna mengetahui ada atau tidaknya masalah desain yang menyebabkan gangguan pada pelayanan air minum serta memberikan rekomendasi bentuk modifikasi yang tepat untuk mengatasi masalah desain jika ada pada jaringan distribusi air minum eksisting PDAM Tirta Patriot. Bahan analisa adalah hasil simulasi pemodelan jaringan distribusi eksisting menggunakan program EPANET 2.0. Berdasarkan penelitian yang telah dilakukan, masalah desain yang ditemukan pada jaringan distribusi PDAM Tirta Patriot adalah adanya titik sambung atau titik distribusi bertekanan di atas standar maksimum tekanan yang diiizinkan untuk pipa PVC pada jaringan distribusi air minum, yakni 8 atm atau 82,66 meter kolom air, serta terdapat pipa-pipa pada jaringan distribusi dengan kecepatan aliran air di bawah batas kecepatan minimum yang diizinkan, yakni 0,3 m/s. Titik sambung bertekanan melebihi standar tekanan yang diiizinkan berjumlah 131 titik dari 132 titik sambung yang disimulasikan, dengan nilai rata-rata tekanan sebesar 86,24 meter. Pipa dengan kecepatan aliran air di bawah kecepatan standar yang sebanyak 54 pipa dari 136 pipa yang disimulasikan, dengan rentang kecepatan aliran air dalam pipa pipa sebesar 0,07 m/s ? 0,29 m/s. Bentuk modifikasi yang dapat dilakukan pada jaringan eksisting untuk mengatasi masalah desain yang ada antara lain pemasangan pressure reducing valveuntuk menurunkan tekanan pada jaringan distribusi air minum, serta pemasangan gate valve dan penggantian pipa bermasalah pipa berdiameter lebih kecil untuk meningkatkan kecepatan aliran air dalam pipa yang bermasalah.

ABSTRACT
Leakage in drinking water distribution network is identified as a major cause of service interference which has been complained by the customers of PDAM Tirta Patriot, Bekasi. However, the design issues in the distribution network is fundamental to be identified, so that the holistic countermeasures can be generated to solve the interference. The purpose of this study is to analyze the existing drinking water distribution network of PDAM Tirta Patriot in order to identify the presence of design issue that may cause interference in water service as well as provide recommendations of appropriate modifications to address a design issue if it is found on existing drinking water distribution network of PDAM Tirta Patriot. Object of analysis is the simulation result of the existing distribution network model using the program EPANET 2.0. Based on research that has been done, the design issues found in the distribution network of PDAM Tirta Patriot are the junctions with the pressure above the maximum allowable limit of 8 atm or 82.66 meter water column , and there are pipes in the distribution network with the velocity below the minimum allowable limit of 0.3 m / s. The number of junctions with the pressure exceed the pressure limit is 131 from 132 simulated junctions, with the average value of pressure of 86.24 meters. The number of pipes with velocity below the standard is 54 from 136 simulated pipes, with velocities range from 0.07 m / s to 0.29 m / s. The modifications that can be performed on existing networks to address the design issues include the installation of a pressure reducing valve to lower the pressure in the water distribution network, and the installation of gate valve and replacing the problematic pipes with the pipes with smaller diameter to increase the velocity."
2016
S65866
UI - Skripsi Membership  Universitas Indonesia Library
cover
Muchammad Abdun Nafik
"

Rasio elektrifikasi di Indonesia pada tahun 2019 mencapai 98.89% namun masih banyak daerah yang rasio elektrifikasinya tergolong rendah, bahkan beberapa daerah masih belum menikmati akses listrik. Elektrifikasi rendah terutama dirasakan oleh masyarakat Indonesia yang tinggal di daerah 3T (terdepan, terluar, dan tertinggal) atau di pulau-pulau kecil. Namun di sisi lain, Indonesia yang secara geografis adalah negara kepulauan dan berada di kawasan tropis memiliki potensi tinggi dalam pengembangan energi terbarukan (ET) sebagai sumber tenaga listrik, khususnya energi surya. Penelitian ini bertujuan untuk merancang model solar home & pumpung system (SHPS) dan menilai kelayakannya. Dalam konsep ini skema SHPS bertujuan memberikan akses listrik kepada masyarakat 3T untuk kebutuhan penerangan dan akses air bersih. Sebanyak 4 unit Lampu LED 3 watt yang dilengkapi baterai digunakan untuk penerangan setiap rumah tangga, sementara pompa air 600 watt dapat digunakan secara komunal untuk 150 rumah tangga. Baik lampu maupun pompa air mendapat pasokan energi listrik dari panel surya masing-masing. Terdapat 3 skenario dalam implementasi SHPS untuk total 150 rumah tangga dengan tingkat diskonto untuk investasi sebesar 10%. Skenario 1 adalah investasi penuh sebesar Rp 806 juta, NPV = Rp 2.8 juta, IRR = 10.05%, PI = 1.003, payback period dalam 9 tahun, masa manfaat 20 tahun. Skenario 2 adalah hibah penuh oleh pemerintah/swasta dengan anggaran 480.5 juta. Skenario 3 adalah hibah oleh pemerintah/swasta untuk lampu tenaga surya (program LTSHE) dan skema investasi untuk pompa air tenaga surya dengan biaya investasi Rp 56 juta, NPV = Rp 1.2 juta, IRR = 11.21%, PI = 1.021, payback period 3 tahun, dengan masa manfaat selama 20 tahun. Keunggulan lain dalam skema SHPS adalah potensi eleminasi emisi karbon dioksida sebesar 4.5 ton per tahun jika untuk kebutuhan yang sama digunakan genset berbahan bakar minyak diesel. Oleh karena itu, SHPS layak dikembangkan dalam mendukung peningkatan elektrifikasi di kawasan 3T.


The electrification ratio of Indonesia has achieved 98.89% in 2019, but there are still many regions where the electrification ratio is relatively low, even some still do not enjoy access to electricity. Low electrification is especially felt by Indonesians living in 3T areas (terdepan/ frontier, terluar/outermost, dan tertinggal/lagging) or on small islands. On the other side, Indonesia, that is geographically an archipelagic and located in the tropics, has high potential in the development of renewable energy for electrical power generation especially solar energy. This study aims to design a solar home & pumpung system (SHPS) model and assess its feasibility. In this concept the SHPS scheme is purposed to provide electricity access to 3T community for the needs of illumination and access to clean water. A total of 4 units of 3 watt LED lights integrated with batteries are used for lighting each household, while a 600 watt water pump can be used communally for 150 households. Both the lamp and the water pump are supplied with electrical energy from their respective solar panels. There are 3 scenarios in the implementation of SHPS for a total of 150 households with a discount rate for investments of 10%. Scenario 1 is a full investment of Rp 806 million, NPV = Rp 2.8 million, IRR = 10.05%, PI = 1,003, payback period in 9 years, with a lifetime of 20 years. Scenario 2 is a full grant by the government/private sector with a budget of Rp 480.5 million. Scenario 3 is a grant by the government/private sector for solar lights (LTSHE program) and an investment scheme for solar water pumps with an investment cost of Rp 56 million, NPV = Rp 1.2 million, IRR = 11.21%, PI = 1,021, payback period of 3 years, with a lifetime of 20 years. Another advantage in the SHPS scheme is the potential elimination of carbon dioxide emissions of 4.5 tons per year if for the same needs utilized diesel-fueled generators. Therefore, SHPS is feasible to be developed in support of increasing electrification in the 3T region.

"
Depok: Fakultas Teknik Universitas Indonesia , 2020
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>