cover
Napitupulu, Erwin
"The contents of fuel-oil are now running low and its prices are becoming more expensive that causes the supply of fuel-oil to the power station in PLN disturbed. Dimmed in district consecutively by the PLN is cause by this event.
Green Medical Box Portable is a storage for the vaccine and other medicine which doesn?t need to depend on electricity from PLN. Alternative source of electricity can be used from the sunlight (solar cell) and battery, so if there is any electricity failure then the temperature can still be obtained and the vaksin and other medicine always in good conditioning.
This Green Medical Box Portable have two storages. The volume of the first storage (freezer) is about 20,4 litre which temperature of storage is about - 15°C. Whereas the volume of second storage (cooler) is about 45,15 litre which temperature of storage is about 5°C.
The refrigeration system of Green Medical Box portable uses DC (Direct Curent) compressor from Danfoss with BD35K type. The refrigerant that used is R 600a."
Depok: Fakultas Teknik Universitas Indonesia, 2008
S50753
UI - Skripsi Open  Universitas Indonesia Library
cover
Taufiq Hidayat
"Green Medical Box adalah sebuah tempat untuk pendinginan obat-obatan, vaksin, darah dan organ dimana menggunakan refrigeran yang ramah lingkungan yaitu R600a. Sumber energi untuk Green Medical box ini bias menggunakan power supply 220 V AC / 12 V DC, batere atau solar panel. Pada tugas akhir ini pengujian hanya menggunakan sumber energi dari power supply 220 V AC / 12 V DC.
Green Medical Box ini terdiri dari 2 kabin yaitu kabin cooler dan kabin freezer. Untuk kabin cooler set point temperaturnya pada +5 °C dan kabin freezer -15 °C. Temperatur kabin diatur oleh dua solenoid yang masing-masing dipasang di liquid line sebelum masuk pipa kapiler, dimana buka tutupnya diatur oleh digital thermostat.
Pengujian Green Medical Box ini dilakukan dengan 3 tahapan percobaan yaitu pertama hanya cooler yang bekerja, kedua hanya freezer yang bekerja dan ketiga cooler dan freezer bekerja bersamaan. Untuk tahapan percobaan pertama dan kedua temperatur set point yang diinginkan tercapai, sedangkan tahapan ketiga saat cooler dan freezer bekerja bersamaan maka freezer hanya mampu mencapai temperatur kabin maksimum selama 1 jam sebesar -8.6 °C, sedangkan cooler pada saat awal temperaturnya turun kemudian menit berikutnya mengalami kenaikan temperatur karena refrigeran cenderung ke freezer sehingga evaporator cooler sedikit sekali terisi refrigeran ( kosong ).
Untuk penelitian salanjutnya penulis menyarankan untuk memakai EPR (evaporator pressure regulator) yang diletakan setelah evaporator cooler untuk mempertahankan tekanan suction nya. Juga jika temperatur set point yang diinginkan belum tercapai saat cooler dan freezer bekerja bersamaan maka hendaknya memperbesar kapasitas kompresor.

Green Medical Box is a storage for refrigeration the medicines, vaccines, blood plasma and organ using friendly environment refrigerant such as R600a. The power of the Green medical Box can uses power supply 220 V AC / 12 V DC, battery or solar panel. This final project only use power supply 220 V AC / 12 V DC.
This Green Medical Box consist of 2 cabin (cooler cabin and freezer cabin). The set point temperature cooler cabin is +5 °C and freezer cabin is -15 °C. Cabin temperature controlled with solenoid each put liquid line before capillary tube. Open close of the selenoid controlled with digital thermostat.
Testing of Green Medical Box have 3 stage: first only cooler ON, second only freezer ON, third Cooler & freezer ON. The first & second stage the set point temperature is attainable. For the third stage, the temperature of freezer during one hour have -8.6 °C, whereas the cooler temperature begining decrease but the next time increase because the refrigerant much to freezer compare to cooler. So the cooler evaporator have little refrigerant.
For the next riset the writer to suggest use EPR (evaporator pressure regulator). Location of EPR after evaporator cooler for holding of suction pressure. If temperature not attainable for third stage, the capacity of compresor must be larger.
"
Depok: Fakultas Teknik Universitas Indonesia, 2008
S38085
UI - Skripsi Open  Universitas Indonesia Library
cover
Aris Muhammad HS
"Menipisnya kandungan bahan bakar fosil serta naiknya harga BBM mengakibatkan pasokan BBM ke pembangkit listrik di PLN sering terganggu. Hal ini berdampak sering terjadi pemadaman secara bergantian oleh PLN.
Green Medical Box Portable merupakan kotak penyimpan vaksin dan obatobatan lainnya yang tidak terlalu tergantung dengan energi listrik dari PLN. Alternatif sumber energi listrik yang digunakan berasal dari cahaya matahari (solar panel) dan batere, sehingga apabila terjadi pemadaman listrik dari PLN, maka vaksin dan obat-obatan lainnya di dalam Green Medical Box tetap dijaga temperaturnya sesuai dengan yang diinginkan.
Green Medical Box Portable mempunyai dua tempat penyimpanan, penyimpanan pertama (freezer) dengan volume + 20,4 liter untuk vaksin dengan temperature penyimpanan ? 15°C. Sedangkan tempat penyimpanan kedua (cooler) dengan volume + 45,15 liter untuk vaksin dengan tempeatur penyimpanan 5 °C.
Untuk sistem refrigerasinya, Green Medical Box Portable menggunakan kompresor DC dari Danfoss dengan tipe BD35K. Refrigeran yang digunakan adalah R 600a.

The contents of fuel-oil are now running low and its prices are becoming more expensive that causes the supply of fuel-oil to the power station in PLN disturbed. Dimmed in district consecutively by the PLN is cause by this event.
Green Medical Box Portable is a storage for the vaccine and other medicine which doesn?t need to depend on electricity from PLN. Alternative source of electricity can be used from the sunlight (solar cell) and battery, so if there is any electricity failure then the temperature can still be obtained and the vaksin and other medicine always in good conditioning.
This Green Medical Box Portable have two storages. The volume of the first storage (freezer) is about 20,4 litre which temperature of storage is about ? 15 °C. Whereas the volume of second storage (cooler) is about 45,15 litre which temperature of storage is about 5 °C.
The refrigeration system of Green Medical Box portable uses DC (Direct Curent) compressor from Danfoss with BD35K type. The refrigerant that used is R 600a.
"
Depok: Fakultas Teknik Universitas Indonesia, 2008
S37349
UI - Skripsi Open  Universitas Indonesia Library
cover
Davied Sapan R.
"Dalam pengobatan dan penelitian biomedis dibutuhkan ultra low cold storage. Pada umumnya proses pendinginan dilakukan dengan nitrogen cair, namun ini tidak praktis dan mahal karena perlu pengisian secara berkala. Untuk mengatasinya harus diusulkan menggunakan mesin pendingin autocascade. Mesin pendingin autocascade mampu mencapai temperatur -40ºC s/d -180ºC (Missimer, 1996), memiliki bentuk yang sederhana, handal dan murah (Yu, 2007).
Penelitian yang dilakukan oleh Chen (2007) dan Apprea (2009) dengan mesin pendingin autocscade terbukti bahwa mesin pendingin ini mampu mencapai lebih rendah dari -120ºC. Namun penelitian tersebut masih menggunakan campuran refrigeran CFC atau HFC yang segera dilarang karena merusak lingkungan.
Penelitian pendahuluan simulasi dan eksperimental mesin pendingin cascade dua tingkat dengan refrigerant ramah lingkungan terbukti mampu mencapai -80ºC (Nasruddin, 2008 & 2009), sehingga bila dilakukan penelitian lebih lanjut akan dapat mencapai temperatur lebih rendah dari -100.
Mempertimbangkan hal tersebut, maka tujuan utama penelitian ini adalah mengembangkan prototipe ultra low cold storage untuk aplikasi bidang biomedis menggunakan mesin pendingin autocascade dengan refrigeran ramah lingkungan. Selain itu juga, hasil penelitian ini juga berpeluang untuk mendapatkan patent ultra low cold storage menggunakan mesin pendingin autocascade dengan refrigeran ramah lingkungan."
Depok: Fakultas Teknik Universitas Indonesia, 2009
S50982
UI - Skripsi Open  Universitas Indonesia Library
cover
Luky Aulia Abadi
"Pada saat ini mesin pendingin tdah menjadi salah satu alai yang dapat menunjang kinerja manusia. Akibatnya mesin pendingin tergolong mesin yang berkembang dengan pesat. Efisiensi merupakan hal yang sangat penting dalam perancangan suatu sistem. Bagaimana dengan jumlah energi masuk sekecil mungkin dan didapat jumlah energi keluaran yang lebih besar. Dalam rangka meningkatkan efisiensi kerja mesin pendingin, dewasa ini digunakanlah sistim pendingin dengan pengaturan aliran refrigerant, dalam unit outdoor, yang putaran motor kompresornya diatur melalui inverter. Motor fan kondenser yang bekerja secara terus-menerus dengan daya yang berubah - ubah sesuai dengan berubahnya beban akan lebih efisien dan pada motor fan kondenser yang bekerja secara start- stop. Daya yang terukur oleh Power Quality Analyser ialah pada frekuensi 60 Hz sebesar 1.032 HY, pada frekuensi 50 Hz sebesar 1.035 kW dan pada frekuensi 40 Hz sebesar 1.074.

At this time the refrigeration machine has to be one tool that can support human performance. As a result, the refrigeration machine that evolved quite rapidly. Efficiency is very important in designing a system. Amount of energy into as small as possible and get the amount of energy output is greater. In order to improve work efficiency refrigeration, cooling system is used today by setting the flow of refrigerant, the outdoor unit, the motor rotation condenser arranged through the inverter. Motor condenser with work continues with the change of power according to changing load will be more efficient than a condenser motor start-stop work. Motor condenser with the start-stop will reduce motor efficiency. Power of system measured by Power Quality Analyser are: at frequency 60 Rz is 1.032 kW at frequency 50 Rz is 1.035 kW and at frequency 40 Rz is 1.074 kW."
Depok: Fakultas Teknik Universitas Indonesia, 2010
S50937
UI - Skripsi Open  Universitas Indonesia Library
cover
Sholahudin
"Banyak proses-proses di industri yang membutuhkan temperatur pendinginan sangat rendah, bahkan bidang biomedis membutuhkan cold storage yang mampu mendinginkan hingga temperatur -80°C. Penggunaan sistem tunggal sulit diaplikasikan pada temperatur yang sangat rendah disebabkan rasio tekanan pada kompresor terlalu tinggi, sebagai gantinya digunakan sistem refrigerasi cascade. Penggunaan refrigeran alamiah seperti campuran karbon dioksida dan hidrokarbon merupakan alternatif untuk menghindari penggunaan refrigeran yang mengandung bahan perusak lapisan ozon dan pemanasan global seperti CFC dan HFC. Pada penelitian ini dilakukan optimasi campuran karbondioksida dan etana sebagai refrigeran sirkuit temperatur rendah untuk mencari nilai optimum dari segi efisiensi exergi dan biaya tahunan. Temperatur evaporator, kondenser, dan cascade dijadikan sebagai variable decision untuk menganalisa sifat- sifat termodinamika refrigeran yang berpengaruh pada efisiensi exergi dan biaya tahunan sistem. Optimasi yang dilakukan menggunakan metode optimasi multiobjektif yang mana efisiensi exergi sebagai fungsi objektif pertama dan biaya tahunan sebagai fungsi objektif kedua. Optimasi ini dilakukan untuk mencari biaya sistem yang sekecil-kecilnya dan memperoleh efisiensi exergi semaksimal mungkin.

Many industrial processes that require low refrigeration temperatures, even the field of biomedicine require cold storage which can cool up to temperature -80 °C. The use of a single refrigeration system is difficult to apply at very low temperatures due to the pressure ratio of compressor is too high. Instead for this application, cascade refrigeration system is used. The use of natural refrigerants, such as carbon dioxide and hydrocarbon mixture is an alternative to avoid the use of refrigerants that contain ozone depleting and global warming such as CFCs and HFCs. Ethane is a hydrocarbon refrigerant that can perform cooling to -80 ° C, but due to it has highly flammable nature, so it is mixed with the carbon dioxide to reduce the flammable nature. In this research, optimization of mixture of carbon dioxide and ethane as a refrigerant in low temperature circuit is run to find the optimum value in terms of exergi efficiency and total annual cost of the system. Temperature of the evaporator, condenser, and a cascade condenser are used as a decision variable to analyze the thermodynamic properties of refrigerants that affect the exergi efficiency and total annual cost of the system. Optimization is run by using multi-objective optimization method which exergi efficiency as the first objective function and total annual cost as the second objective function. This optimization is performed to find the cost of the system is minimum and exergi efficiency is maximum.
"
Depok: Fakultas Teknik Universitas Indonesia, 2013
S45472
UI - Skripsi Membership  Universitas Indonesia Library
cover
Andi Taufan
"Isu lingkungan mengenai pemanasan global dan penipisan ozon merupakan faktor pendorong inovasi ramah lingkungan. Oleh karena itu, dikembangkanlah alat pendingin adsorpsi menggunakan metanol yang ramah lingkungan sebagai refrigeran dan karbon aktif sebagai adsorben. Pada alat pendingin adsorpsi yang sedang dikembangkan Departamen Teknik Mesin Universitas Indonesia perlu untuk diketahui karakteritik proses adsorpsi dan efek pendinginannya. Pengujian dilakukan dengan menggunakan metanol sebanyak 250 ml sebagai gambaran awal performa adsorber pada proses adsorpsi selama 75 menit. Pada akhir proses didapatkan perubahan tekanan di evaporator sebesar 2 cmHg dan di adsorber sebesar 1,3 cmHg dengan rata-rata perbedaan tekanan antara keduanya selama 75 menit sebesar 4,6 cmHg. Temperatur terendah yang dicapai di evaporator sebesar 14°C yang dicapai setelah menit ke-65.

Environmental issues about global warming and ozone depleting are the factors stimulating green innovation. Therefore, adsorption refrigeration system has been developed with methanol as a green refrigerant and actived carbon as adsorbent. It is important to know the characteristics of the adsorpstion process and refrigeration effect of the machine that developed by Department of Machine Engineering, Universitas Indonesia. It is used 250 ml methanol as refrigerant during 75 minutes of experiment. At the end of adsorpstion process it is produce the pressure difference in evaporator about 2 cmHg and 1,3 cmHg in adsorber with mean pressure difference about 4,6 cmHg. The lowest temperature in evaporator is 14°C that reached after 65 minutes running."
Depok: Fakultas Teknik Universitas Indonesia, 2008
S50739
UI - Skripsi Open  Universitas Indonesia Library
cover
Dedeng Rahmat
"Dalam aplikasinya di bidang industri, sistem refrigerasi tunggal dan bertingkat tidak mampu untuk mengatasi perbedaan yang cukup besar antara kalor yang akan diserap dengan kalor yang akan dibuang, namun, tidak demikian dengan sistem cascade. Penelitian dengan alat yang sederhana yang telah dilakukan sebelumnya dengan menggunakan refrigeran alami telah menawarkan peluang yang baik.
Skripsi ini membahas tentang pengujian sistem cascade dengan menggunakan dua macam refrigeran sebagai variasi di sisi bagian HS, sedangkan pada bagian LS, digunakan campuran refrigeran alami R170/R744. Pengujian dilakukan dengan tiga cara, yaitu : memvariasikan komposisi massa campuran R170/R744, memvariasikan bukaan katup ekspansion LS, serta memvariasikan jenis refrigeran pada sisi bagian HS. Temperatur evaporasi terrendah yang bisa dicapai oleh sistem ini adalah -69,7°C dengan COP sebesar 1,88. Dengan kondisi 700g R22 pada sisi bagian HS dan 100g R170 pada sisi bagian LS

In many industrial applications, single stage and multi stage refrigeration systems fail to widen the gap between heat source and heat sink temperatures and now cascade system appear to be the best alternative. Modest reserch, in the past, has been done in cascade system based on natural refrigerants thereby offering good potential for research.
In this paper, a cascaded system for simultenous heating and cooling with a R22 and R290 based high-stage (HS) cycle and mixed R170/R744 based low-stage (LS) cycle for simultenous refrigeration and heating application has been analyzed. To facilate prediction of optimum performance parameter, performance trends with variation in fraction mass of R170/R744, variation in flow rate of ekspansion valve of LS, and variation refrigerant of HS have been presented. The lowest temperature reached in -69,7°C with COP 1,81. 700g of R22 (HS) and 100g of R170 (LS)
"
Depok: Fakultas Teknik Universitas Indonesia, 2008
S50736
UI - Skripsi Open  Universitas Indonesia Library
cover
Siallagan, Timothy Felix Vickary
"Penggunaan refrigeran khususnya klorofluorokarbon (CFC), Hidrofluorokarbon (HFC), dan Hidroklorofluorokarbon (HCFC) pada kulkas berkontribusi besar dalam pemanasan global, sementara penggunaan Hidrokarbon sudah terbukti menjadi pilihan yang lebih baik. Penelitian ini menunjukkan hasil analisa berbasis eksergi dari siklus refrigerasi pada kulkas rumah tangga menggunakan refrigeran hidrokarbon (R600a) sesuai dengan standar SNI ISO15502:2008. Dengan menerapkan metode Taguchi pada desain eksperimen dan melalui penetapan parameter eksergi diantaranya entalpi, entropi, laju alir massa, coefficient of performance (COP), tipe susunan beban pendingin, sehingga penggunaan optimum dapat diperoleh. Model analisis yang digunakan adalah siklus yang mengikutsertakan irreversibilitas dari perpindahan kalor melalui perbedaan temperature terbatas, kebocoran kalor, dan disipasi internal. Pendekatan dilakukan dengan mengkombinasikan persamaan matematis atau simulasi siklus dalam Engineering Equation Solver (EES) dengan eksperimentasi secara langsung pada kulkas yang berada didalam ruang uji lingkungan dimana keadaan lingkungan sudah dikondisikan sesuai ketetapan yang berlaku.

The use of refrigerant specifically Chlorofluorocarbons (CFC), Hydrofluorocarbons (HFC), and hydrochlorofluorocarbons (HCFC) in refrigerators greatly contribute to global warming, while the choice of hydrocarbon refrigerant proves to be a better option. This research shows the results of an exergy-based analysis of the irreversible refrigeration cycle on household refrigerators using hydrocarbon refrigerant (R600a) in accordance with SNI ISO15502: 2008 standard. By applying Taguchi Method for experimental design and through parameters of determinants of exergy such as enthalpy, entropy, mass flow rate, the coefficient of performance (COP), load array types, therefore the optimum use of refrigerant can be obtained. The model analyses used is cycle that include irreversibility of heat transfer across finite temperature differences, heat leakage, and internal dissipation. The approach is done by combining mathematical modelling or simulation cycle in engineering equation solver (EES) software with experiment directly on refrigerator inside environmental chamber where environment has been conditioned according to the prevailing provisions."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rifky Tri Wahyu Rosadi
"Dalam dunia pengobatan dan penelitian biomedis kebutuhan akan ruang pendingin yang dapat mencapai temperatur sangat rendah yaitu -80°C sangat dimintai karena dengan tenperatur -80_C ini spesimen biomedis tidak mudah rusak, aplikasinya di bidang industri sistem refrigasi tunggal dan bertingkat tidak dapat mengatasi perbedaan yang cukup besar antara kalor yang akan diserap dan kalor yang akan dibuang akan tetapi berbeda dengan sistem refrigasi cascade. Penelitian yang dilakukan menggunakan alat yang sederhana dengan refrigeran alami ini memberikan peluang yang baik. Skripsi ini membahas mengenai pengujian sistem refrigerasi cascade dengan menggunakan refrigeran hidrokarbon pada bagian sirkuit temperatur tinggi dan refrigeran campuran R744 dengan R170 pada sirkuit temperatur rendah. Pengujian dilakukan dengan menggunakan propane sebagai refrigeran pada temperatur tinggi dan variasi komposisi masa pada sirkuit temperatur rendah untuk mencari komposisi optimum campuran R744 dengan R170. Temperatur evaporasi terendah yg dicapai pada sirkuit temperatur rendah ini adalah -94.8°C dengan refrigeran CO2 murni akan tetapi temperatur tersebut tidak stabil, sedangkan temperatur stabil -77.95°C dicapai oleh refrigeran ethane murni dengan COP 0.77. Untuk komposisi campuran COP yang didapat sebesar 0.58 dengan komposisi 60% R744 dan 40% R170.

In the world of biomedical the need of cold storage that can achieve temperature of -80°C is wanted because with that temperature biomedical specimen can not easily broken, in industrial application single stage and multi stage refrigeration system can not overcome the gap between the heat that will be absorb and the heat that will be release but it is different with the cascade system. The experiment that is conduct with simple cascade system and the use of natural refrigerants make the cascade system appear to be the best alternative. This paper will explain about the cascade system that will use a hidrocarbon on High Stage and blend refrigerant between R744 and R170 on Low Stage. The experimant is conduct with propane refrigerant in the high Stage and variation of blend refrigerant between R744 and R170, the use of pure CO2 and the use of pure etahne. The lowest temperature that can be reached is -94.8°C with pure CO2 but the temperature is unstable and the stable temperature is achieve by pure ethane -77.95°C with the COP 0.77. For the blend composistion the highest COP is 0.58 with 60%R744 an 40%R170."
Depok: Fakultas Teknik Universitas Indonesia, 2009
S50789
UI - Skripsi Open  Universitas Indonesia Library