Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 32737 dokumen yang sesuai dengan query
cover
"One of the efforts foe water quality management is water pollution. The effort needs accurate water quality measurements which should be done by certified laboratories...."
Artikel Jurnal  Universitas Indonesia Library
cover
Cecep Aminudin
"Pencemaran udara dapat disebabkan oleh berbagai sumber, antara lain dari aktifitas industri. Untuk mengatasi persoalan pencemaran udara, termasuk dari industri, pemerintah di berbagai negara, termasuk di Indonesia, mengeluarkan berbagai macam kebijakan untuk mengendalikannya. Namun demikian, penelitian mengenai efektivitas dari kebijakan yang telah ditetapkan masih sangat kurang dilakukan. Oleh karena itu, tujuan dari penelitian ini adalah berusaha untuk: (1) mengetahui efektivitas kebijakan pengendalian pencemaran udara industri di DKI Jakarta, Indonesia, (2) mengetahui efektivitas kebijakan pengendalian pencemaran udara industri di NSW, Australia. (3)mengetahui perbandingan efektivitas kebijakan pengendalian pencemaran udara industri di DKI Jakarta dengan di New South Wales.
Penelitian ini menggunakan pendekatan expost facto terhadap data sekunder berupa laporan-laporan badan-badan pemerintah di kedua negara yang diterbitkan antara tahun 1990 - 2006 dan hasil-hasil penelitian lain yang relevan. Analisa dilakukan secara kuantitatif dan kualitatif untuk menentukan nilai (1-5) dari masing-masing parameter efektivitas kebijakan pengendalian pencemaran udara industri. Parameter untuk mengukur efektivitas kebijakan terdiri dari parameter produk kebijakan (policy output), parameter hasil antara kebijakan (intermediate outcomes) dan parameter hasil akhir kebijakan (end outcomes). Nilai rata-rata dari semua parameter kemudian dimasukan dalam skala efektivitas untuk mengetahui tingkat efektivitas kebijakan pengendalian pencemaran udara industri dan masingmasing lokasi penelitian. Kategori tingkat efektivitas yang ditetapkan dalam penelitian ini, mulai dari yang terendah, adalah: tidak efektif, belum efektif, potensial efektif, cukup efektif, sangat efektif.
Dengan sistem negara Indonesia yang berbentuk kesatuan, kebijakan pengendalian pencemaran udara industri yang berlaku di Jakarta berada pada level nasional dan level daerah. Kebijakan pengendalian pencemaran, termasuk pencemaran udara industri, dimulai pada tahun 1980-an. Instrumen kebijakan pengendalian pencemaran udara industri di tingkat nasional maupun di tingkat daerah hampir lama dan lebih menitikberatkan pada pendekatan atur dan awasi atau command and control. Sementara itu, pendekatan ekonomi belum banyak dikembangkan baik di level nasional maupun di level daerah. Evolusi pengaturan pencemaran di Indonesia bergerak ke arah desentralisasi dengan penguatan peran pemerintah daerah dalam pengendalian pencemaran danpenjabaran kebijakan pengendalian pencemaran untuk berbagai macam media termasuk udara.
Sementara itu, dengan sistem negara Australia yang berbentuk federal, di NSW kebijakan pengendalian pencemaran udara industri lebih banyak berada di tangan negara bagian. Sedangkan pemerintah federal hanya mengembangkan kebijakan umum seperti ketentuan tentang baku mutu udara ambien. Kebijakan pengendalian pencemaran udara, termasuk dari sumber industri, dimulai pada tahun 1960-an. Selain itu, instrumen ekonomi dalam bentuk load based licensing juga sudah mulai dikembangkan di tingkat negara bagian NSW disamping penyempurnaan pada pendekatan command and control. Evolusi pengaturan pencemaran udara industri di Australia, khususnya di NSW bergerak ke arah integrasi pengendalian pencemaran antara sate jenis media dengan media lainnya, dan mulai berperannya pemerintah federal dalam upaya pengendalian pencemaran.
Terkait dengan tujuan penelitian, dari studi ini diketahui bahwa di DKI Jakarta produk kebijakan (policy output) berupa pendayagunaan berbagai macam instnunen kebijakan (mixed policy instrument) masih lemah, kondisi basil antara kebijakan (intermediate outcomes) berupa perilaku penaatan industri terhadap kebijakan masih rendah dan hasil akhir kebijakan (end outcomes) berupa beban emisi dari industri dan kualitas udara ambien di daerah industri juga masih belum baik. Sedangkan di New South Wales, produk kebijakan (policy output) berupa pendayagunaan berbagai macam instrumen kebijakan (mixed policy instrument) cukup kuat, kondisi hasiI antara kebijakan (intermediate outcomes) berupa perilaku industri terhadap kebijakan cukup tinggi dan hasil akhir kebijakan (end outcomes) berupa beban emisi dari industri dan kualitas udara ambien juga cukup baik.
Dari hasil penelitian ini dapat diambil kesimpulan: (1)kebijakan pengendalian pencemaran udara industri di DKI Jakarta termasuk dalam kategori belum efektif (2)kebijakan pengendalian pencemaran udara industri di New South Wales termasuk kategori potensial efektif. (3)kebijakan pengendalian penemaran udara industri di New South Wales lebih efektif dibanding kebijakan pengendalian pencemaran udara industri di DKI Jakarta.
Untuk mengurangi kesenjangan tingkat efektivitas di Jakarta dibandingkan di New South Wales perlu dilakukan perbaikan strategi kebijakan, penguatan kapasitas kelembagaan pemerintah, penguatan upaya penegakan hukum, serta perhatian politik yang cukup dari penentu kebijakan.

The main sources of urban air pollution are come from transportation and industrial activity. To overcome the problem, the governments in the world are trying to formulate and implement policy to control industrial air pollution in various policy approaches. However, the research about the effectiveness of that policy is still rare. The aims of this research are: (1) To know about the effectiveness of industrial air pollution control policy in Jakarta, Indonesia, (2) To know about the effectiveness of industrial air pollution control policy in New South Wales, Australia. (3) To compare the effectiveness of industrial air pollution control policy in Jakarta and New South Wales.
This research is based on ex-post facto approach which uses secondary data from the report of government agency in bath countries that issued between 1990 - 2006 and another research report which are relevant with this thesis. The analysis is based on quantitative and qualitative method to find the value for each research indicator in 1-5 scale. The average value fromall indicator then classified into the effectiveness scale index to know the degree of the effectiveness. This research divide the effectiveness scale, from lower to higher, are: not effective, not yet effective, potentially effective, sufficiently effective and very effective.
With the Indonesian unitary state system, the air pollution control policy is on the hand of local as well as the central government. The pollution control policy, including pollution from industry, was begin in 1980-s. The policy instrument that had been applied in national and local level are very similar and give more emphasize on command and control approach. Meanwhile, the economic instrument are still under developed. The evolution of pollution control in Indonesia are moving from centralized to decentralized system and the empowering of local government role in protecting environment Indonesia also at the stage of elaborating the environment protection policy in various kind of pollution media, including air pollution, from general principle and regulation of environmental protection.
Meanwhile, with the Australian federal system of the state, air pollution control policy in NSW is heavily on the hand of the state. While the federal government only developing general policy such as ambient air quality standard. The air pollution control policy in Australia was begin in 1960-s. The economic instrument in the form of load based licensing are developed in NSW since 1997 beside the reformation of the enforcement system. The evolution of pollution control in Australia, especially in NSW, are moving from media specific to more integrated and multimedia approach. Australia also at the stage of empowering the federal government to take responsibility for controlling pollution especially on national significant pollution issues.
Related with the objective of the research, this study found that, in Jakarta, the utilization of mixed policy instrument as a policy output are weak, the condition of the compliance behavior of industry as an intermediate policy outcome is low and the emission load and the ambient air quality in industrial area as end policy outcomes is not so good. Meanwhile, in New South Wales, the utilization of mixed policy instrument as a policy output are strong, the condition of the compliance behavior of industry as an intermediate policy outcome is high and the emission load and the ambient air quality in industrial area as end policy outcomes are relatively better than in Jakarta.
The conclusion of this research are, generally the effectiveness level of industrial air pollution control policy in Jakarta are not yet effective, while the effectiveness level of industrial air pollution control policy in New South Wales are potentially effective. So the effectiveness of industrial air pollution control policy in New South Wales is one level higher than in Jakarta.
To fill the effectiveness gap in Jakarta which is lower than in New South Wales, it is a need to reform the policy strategy, strengthening institutional capacity, strengthening law enforcement efforts, and adequate political support from the policy makers."
Depok: 2006
T17904
UI - Tesis Membership  Universitas Indonesia Library
cover
Tuapetel, Jones Victor
"Catalytic converter adalah salah satu metode yang digunakan untuk mengontrol emisi gas buang sebagai penyebab polusi terutama pada kendaraan. Gas buang terdiri dari gas-gas karbondioksida (CO2), karbon monoksida (CO), nitrogen oksida (NO), hidrokarbon (HC) dan kandungan gas lainnya. Konversi emisi gas buang dalam catalytic converter disamping tergantung pada performans katalis dalam bentuk honeycomb juga tergantung pada distribusi aliran gas dalam penampang.
Untuk meningkatkan keseragaman distribusi ini maka dapat digunakan kombinasi screen dengan porositas 0,87 dan honeycomb dimana kecepatan aliran bisa diperlambat sehingga residence time lebih lama yang tentunya meningkatkan performans honeycomb. Hasil yang diinginkan adalah fenomena dinamika aliran yang lebih terdistribusi merata sehingga dapat meningkatkan proses konversi emisi gas buang. Metode yang digunakan adalah simulasi pada komputer yang menggunakan software Fluent/UNS sementara analisa numerik dilakukan dalam bentuk eksponensial yang ditransformasikan dalam bentuk grid.
Hasil simulasi menunjukkan fenomena aliran yang lebih terdistribusi merata sehingga meningkatkan proses konversi emisi gas buang.

Catalytic converter is a method to reduce the level of pollutants in the exhaust, especially on vehicle. Emission exhausts gases containing carbon dioxide (CO2), carbon monoxide (CO), nitrogen oxide (NO), unburned hydrocarbon (HC), and other gases. Conversion of the emission in the catalytic converter besides to depend on performance of catalyst as honeycomb also depending on gas stream distribution in the channel of the converter.
To increase the distribution, combination of screen with 0.87 porosity and honeycomb are used to reach this condition and flow velocity can be slowly so that residence time is longer. The combination also can increase performance of honeycomb of catalytic converter. The method to be used is simulation analysis was under the use of computer programming soft ware Fluent/UNS, while the numerical analysis was done by exponential forms that were transformed into grid shape.
Result of simulation to indicate the mode of stream more distributed and increasing conversion process of the emission exhaust gases."
Depok: Fakultas Teknik Universitas Indonesia, 2002
T9154
UI - Tesis Membership  Universitas Indonesia Library
cover
Retno Dewi Handayani Sujatno
"Kebisingan adalah suara-suara yang tidak dikehendaki. Kebisingan akibat kegiatan industri dan transportasi adalah hal yang lazim ditemukan, oleh karenanya seberapa tinggi nilai kebisingan serta usaha-usaha pencegahan yang berkaitan dengan pengaruh di lingkungan dan tenaga kerja adalah hal yang penting untuk dipantau dan diteliti. Seperti halnya daerah industri lainnya di sekitar Jakarta, daerah Cikampek dan sekitamya adalah daerah dengan perkembangan kawasan industri yang cukup pesat dengan arus transportasi yang cukup padat. Pihak industri di sekitar kawasan tersebut banyak yang telah memanfaatkan vegetasi bambu (Bambusa sp.) dan jati (Tectona grandis) salah satunya sebagai peredam kebisingan.
Berdasarkan uraian di atas, maka timbul suatu pemikiran untuk meneliti apakah vegetasi bambu (Bambusa sp.) dan jati (Tectona grand's) yang ada di sekitar kawasan industri dan tepi jalan tol Jakarta-Cikampek-Sadang dapat mereduksi kebisingan. Lokasi penelitian yang dipilih adalah di sekitar pabrik PT Pupuk Kujang, Cikampek, Jawa Barat Hal ini didasari karena pada lokasi tersebut ditemukan kedua kelompok jenis vegetasi tersebut. Selain hal tersebut di atas diketahui juga bahwa pada umumnya kebisingan di area pabrik PT Pupuk Kujang hampir pada semua titik pemeriksaan ada di atas Nilai Ambang Batas (NAB), yaitu antara 84-113 dB(A), sedangkan pada jalan tol Jakarta-Cikampek di sebelah Seiatan industri PT Pupuk Kujang juga di atas baku mutu yang ditetapkan yaitu tingkat kebisingan pada siang hari 85,9 dB(A) dan pada malam hari 83,5 dB(A) (Widagdo, 1998). Kondisi eksisting letak populasi vegetasi tersebut diharapkan memudahkan penyusunan desain penelitian.
Melanjutkan uraian di atas maka rumusan permasalahan yang dapat disusun adalah:
1. Kelompok vegetasi rumpun bambu di sekitar pabrik PT Pupuk Kujang dapat mereduksi kebisingan yang bersumber dari pabrik PT Pupuk Kujang.
2. Kelompok vegetasi jati di sekitar pabrik PT Pupuk Kujang dapat mereduksi keblsingan yang bersumber dari aktivitas jalan tol Jakarta-Cikampek di sebelah Selatan industri PT Pupuk Kujang.
Tujuan penelitian dapat dibagi menjadi 2 golongan yaitu:
1. Tujuan Umum:
Pemakaian vegetasi untuk meredam kebisingan.
2. Tujuan Khusus:
a. Diketahuinya seberapa besar pengaruh kelompok vegetasi rumpun bambu di sekitar pabrik PT Pupuk Kujang daiam mereduksi kebisingan yang bersumber dari pabrik PT Pupuk Kujang.
b. Diketahuinya seberapa besar pengaruh kelompok vegetasi jati di sekitar pabrik PT Pupuk Kujang dalam mereduksi kebisingan yang bersumber dari aktivitas jalan tol Jakarta-Cikampek di sebelah Selatan industri PT Pupuk Kujang.
Hipotesis yang diajukan dalam penelitian ini adalah kelompok vegetasi rumpun bambu (Bambusa sp.) dan jati (Tectona grandls) di sekitar pabrik PT Pupuk Kujang dapat mereduksi kebisingan sebesar ±3-18%. Janis penelitian ini adalah deskriptif kuantitatif dengan metode survey. Desain penelitian yang digunakan adalah cross sectional.
Hasil uji t untuk tingkat reduksi kebisingan pada bambu temyata mernperlihatkan penurunan kebisingan yang signifikan (p<0,05), dengan nilai signifikansi sebesar 0,019, sedangkan pada jati temyata memperlihatkan penurunan kebisingan yang tidak signifikan (p>0,05), dengan nilai signifikansi sebesar 0,059. Seiain itu berdasarkan uji korelasi tebal kelompok vegetasi rumpun bambu dan jati pada efektivitas reduksi kebisingan memperlihatkan hasil yang sangat kuat, dengan koefisien korelasi bambu 0,975 dan koefisien korelasi jati 0,840. Hasil pengukuran kebisingan di Dusun Poponcol (Desa Dawuan Tengah) yang berjarak 180 m dari pabrik tingkat kebisingannya 57,80 dB(A), sedangkan dipermukiman karyawan yang berjarak 480 m dari pabrik tingkat kebisingannya 48,20 dB(A).
Berdasarkan hasil dan pembahasan maka kesimpulan yang diperoleh adalah:
1. Kelompok vegetasi rumpun bambu di sekitar pabrik PT Pupuk Kujang dapat mereduksi kebisingan yang bersumber dari pabrik PT Pupuk Kujang. Semakin tebal kelompok vegetasi rumpun bambu, semakin tinggi persentase efektivitas reduksi kebisingannya.
2. Kelompok vegetasi jati di sekitar pabrik PT Pupuk Kujang dapat mereduksi keblsingan yang bersumber dari aktivitas jalan tol Jakarta Cikampek di sebelah Selatan industri PT Pupuk Kujang. Namun secara statistik reduksi kebisingan tersebut tidak signifikan.

Noise is an unwanted sounds. It has been commonly founded in industrial area and transportation, hence it is still important to be observed and researched on how high the noise level is and how to find efforts in avoiding the noise effect on environment and workers. Likely other industrial area surrounding Jakarta, Cikampek and its neighbourhood areas have become developed industrial areas with a traffic transportation flow. The industry players nearby have utilized vegetation bamboo (Bambusa sp.) and teak wood (Tectona grandis) as means of noise soundproof surrounding the area.
A thought then occurs whether natural vegetation of bamboo (Bambusa sp.) and teak wood (Tectona glandis) surrounding Cikampek industrial areas and along Jakarta-Cikampek-Sadang highways can reduce the noise or not. Location chosen is industrial area of PT Pupuk Kujang, Cikampek, West Java. Based on the existence of both vegetation bamboo and teak wood nearby location. Based on some e)aminations, it is almost found that noise level around factory area is categorized above Critical Value, which ranges between 83-113 dB(A), meanwhile, in the southern industrial area of PT Pupuk Kujang and along Jakarta-Cikampek highway, the same case is found which is both noise levels in afternoons and at nights are categorized above the normal range, each ranges 85,9 dB(A) in afternoons and 83,5 dB(A) at nights (Widagdo, 1998).The condition of where the vegetation populations are will be expected to determine research design more easily.
Some problems measured are :
1. Bamboo vegetation surrounding industrial area of PT Pupuk Kujang is able to reduce noise from PT Pupuk Kujang factory.
2. Teak wood vegetation surrounding industrial area of PT Pupuk Kujang is able to reduce noise from Jakarta-Cikampek highway in the southern part of PT Pupuk Kujang industrial area.
The objectives consist of 2 groups:
1. General Objective:
Vegetation utilization to soundproof noise.
2. Particular Objective:
a. To measure the effectiveness of bamboo vegetation surrounding industrial area of PT Pupuk Kujang in reducing noise from PT Pupuk Kujang factory.
b. To measure the effectiveness of teak wood vegetation surrounding industrial area of PT Pupuk Kujang in reducing noise from Jakarta-Cikampek highway which is located in the southern part of PT Pupuk Kujang industrial area.
Hypothesis proposed in research is bamboo (Barnbusa sp.) and teak wood (Tectona grandis) vegetation surrounding factory of PT Pupuk Kujang are able to reduce noise of t3-18%. Research type is descriptive quantitative with survey method. The design used Is cross sectional.
T -test on noise reduction level of bamboo vegetation shows the significaint noise reduction (p<0,05) with significant value of 0,019, meanwhile noise reduction level of teak wood vegetation shows the insignificant noise reduction (p>0,05), with significant value of 0,059. Correlation test on thickness of bamboo and teak wood vegetation to noise reduction effectivity shows a very strong correlation with bamboo coefficient of 0,975 and teak wood coefficient of 0,840. Noise measurement result in Dusun Poponcol (Dena Dawuan Tengah) on distance of 180 m from factory has noise level of 57,80 dB(A), meanwhile in worker residences on distance of 480 m from factory has noise level of 48,20 dB(A).
This research concludes some points, which are:
1. Bamboo vegetation surrounding PT Pupuk Kujang area is able to reduce noise sourced from PT Pupuk Kujang factory. The more thick the bamboo vegetation is, the more higher is the percentage effectivity of noise reduction.
2. Teak wood vegetation surrounding PT Pupuk Kujang area is able to reduce noise sourced from JakarEa-akampek highway in the southern part of PT Pupuk Kujang area. Statistically, noise reduction is not significant.
"
Program Pascasarjana Universitas Indonesia, 2004
T14929
UI - Tesis Membership  Universitas Indonesia Library
cover
H. Widjatmoko
"ABSTRAK
Penggunaan bahan bakar gas untuk kendaraan bermotor sangat menguntungkan dilihat dari segi ekonomis karena harga jual BBG leblh murah , BBG juga sangat menguntungkan dilihat dari segi polusi udara yang ditimbulkan dbandingkan dengan kendaraan bermotor berbahan bakar premium maupun bahan bakar solar, disebabkan emisi gas buang yang bersih dan sehat tidak menimbulkan dampak negatif terhadap lingkungan.
Namun kendaraan bahan bakar gas masih mempunyai permasalahan yaitu daya yang berkerja belum maksimum (terjadi penurunan daya).
Di dalam penelitian ini berupaya untuk menaikkan daya dengan cara modifikasi diameter saluran udara mixer dari 30 mm menjadi 28 mm dan perubahan sudut pancar mixer dari 470 menjadi 54° . Uji coba kendaraan dilakukan di laboratorium dengan metode variasi putaran (Variable Speed ) dari putaran 1000 rpm s/d 4000 rpm.
Hasil yang diperoleh dari penelitian ini Daya efeklif bertambah besar yaitu untuk perubahan diameter sebesar 11,59 hp , sedangkan untuk perubahan sudut daya efektif hanya bertambah sedlkit yaitu 1 hp."
1998
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
"Tributyltin (TBT) -based coatings have been banned although they are effective to prevent biofouling because they had bad ecology effect for nontarget organism. Since the banned of BTB - based coatings, there are a lot of researches about alternative biocides. Those researches were aimed to study ecological assessments of biocides on aquatic organism. This paper provides information about several methods of biocide toxicity assessment on several aquatic organisms."
Artikel Jurnal  Universitas Indonesia Library
cover
"A water quality evalution was done on 30 (thirty) rivers of Indonesia. Analysis was based on measurement results collected by the ministry for the environment and the Research Centre for Water Resources from 2000 up to 2005, whereas eavaluation was implemented according to the STORET method and Government Regulation No. 82/ 2001 on Water quality management and water pollution control...."
Artikel Jurnal  Universitas Indonesia Library
cover
Fifi Rizqi Nurkhaeriyah
"ABSTRAK

Dalam dekade terakhir, program penilaian peringkat kinerja perusahaan (PROPER) dalam pengelolaan lingkungan hidup dan ISO 14001 telah digunakan oleh perusahaan untuk mengurangi polusi industri di Indonesia. Kedua program ini penting bagi perusahaan untuk menangani masalah lingkungan. Perusahaan bersertifikat ISO 14001 akan mendapat tekanan untuk mengembangkan sistem kinerja lingkungan mereka dalam mengukur dan mengevaluasi efektivitas program yang terkait dengan pengelolaan lingkungan. PROPER mungkin efektif bagi perusahaan bersertifikasi ISO 14001 untuk mengurangi polusi industri dan digunakan untuk mengukur kinerja lingkungan perusahaan. Penelitian ini bertujuan untuk menyelidiki hubungan antara PROPER dan ISO 14001 dalam mengendalikan, mengelola, dan memantau lingkungan. Metode geomean, dan korelasi spearman digunakan dalam penelitian ini. Hasil penelitian ini menunjukkan bahwa integrasi PROPER dan ISO 14001 dapat digunakan oleh perusahaan dalam penyusunan sistem manajemen lingkungan. Hal ini didasarkan pada hasil penelitian yang menunjukkan bahwa terdapat beberapa klausul ISO 14001 mempengaruhi semua aspek penilaian PROPER dan terdapat korelasi antara perusahaan yang telah mengimplementasikan ISO 14001 dengan penghargaan PROPER yang diperoleh, di mana implementasi ISO 14001 membantu atau efektif bagi perusahaan untuk mendapatkan penghargaan PROPER yang lebih baik. PROPER juga dapat digunakan oleh perusahan sebagai environmental performance untuk mengukur efektivitas ISO 14001 yang telah dijalankan.


ABSTRACT

 


In last decade, the program for pollution control evaluation and rating (PROPER) in environmental management and ISO 14001 have been used by companies to reduce industrial pollution in Indonesia. Both programs are important for companies to deal with environmental issues. ISO 14001 certified companies will be pressured to develop their environmental performance systems in measuring and evaluating the effectiveness of programs related to environmental management. PROPER may be effective for companies that are ISO 14001 certified to reduce industrial pollution and are used to measure the company`s environmental performance. This study aims to investigate the relationship between PROPER and ISO 14001 in controlling, managing and monitoring the environment. The geomean method, and spearman correlation were used in this study. The results of this study indicate that the integration of PROPER and ISO 14001 can be used by companies in the preparation of environmental management systems. This is based on the results of research that show that there are several clauses of ISO 14001 affecting all aspects of PROPER assessment and there is a correlation between companies that have implemented ISO 14001 and PROPER awards obtained where ISO 14001 implementation is helpful or effective for companies to get better PROPER awards. PROPER can also be used by companies as an environmental performance to measure the effectiveness of ISO 14001 that has been implemented.

 

"
2019
T54235
UI - Tesis Membership  Universitas Indonesia Library
cover
Suryawati
"ABSTRAK
Penggunaan zat radioaktif dalam bermacam-macam bidang di Indonesia saat ini telah semakin luas pada berbagai segi kehidupan yang mencakup beberapa sektor dalam Pembangunan Nasional seperti bidang kedokteran nuklir, pertanian, hidrologi, industri.
Pemanfaatan tenaga atom ini bertujuan untuk meningkatkan kesejahteraan mengingat tenaga atom disamping memberikan manfaat, juga dapat menimbulkan bahaya bagi keselamatan pekerja radiasi, masyarakat umum dan komponen lingkungan lainnya maka dalam pelaksanaannya diperlukan pengawasan dan pembinaan yang ketat. Untuk tujuan ini diperlukan pemantauan radioaktivitas lingkungan terhadap industri yang memanfaatkan bahan radioaktif dalam proses produksinya.
Salah satu industri yang memanfaatkan zat radioaktif thorium alam dalam bentuk thorium nitrat (ThNO3) sebagai pencampur bahan bakunya atau pelapis rajutan serat nilon bahan dasar kaos lampu adalah industri pembuatan kaos lampu petromak (Incandescent Gas Mantle).
Dalam proses produksi kaos lampu ini selain dihasilkan produk kaos lampu yang siap dipasarkan juga dihasilkan limbah radioaktif berbentuk cair, padat dan gas yang dibuang ke lingkungan dengan persyaratan tertentu. Dalam penelitian ini yang akan diselidiki adalah limbah gas (gas thoron) dan limbah padat berupa partikel debu radioaktif yang bersumber dari kegiatan produksi, yang kemungkinan menjadi penyebab terjadinya kontaminasi udara dalam kawasan pabrik dan lingkungan sekitamya sehingga akan mengakibatkan naiknya tingkat radioaktivitas lingkungan.
Meningkatnya radioaktivitas lingkungan di udara, yang disebabkan oleh thorium dan anak luruhnya yang melekat di debu udara lingkungan pabrik dan kawasan pemukiman penduduk yang terdekat di sekitar pabrik akan menimbulkan potensi bahaya radiasi intema bila debu radioaktif tesebut terhisap oleh pekerja dan penduduk, kemudian terbawa masuk ke paru-paru. Tingkat bahaya radiasi ini dapat diindikasi dari besaran tingkat kerja atau working level dan dosis ekivalen efektif paru-paru yang diterima pekerja dan penduduk. Kedua nilai besaran ini dibandingkan dengan nilai ambang batas yang diizinkan.
Untuk mempertimbangkan adanya potensi bahaya ini, perlu diadakan penelitian tingkat radioaktivitas di dalam daerah kerja kawasan pabrik dan di luar kawasan pabrik kaos lampu dalam pemukiman penduduk yang terdekat, dapat diperkirakan tingkat bahaya radiasi terhadap pekerja dan masyarakat disekitar pabrik.
Mengingat hal tersebut, timbul beberapa pertanyaan penelitian : (1) Apakah konsentrasi radioaktif thorium dan anak luruhnya di udara dalam kawasan pabrik dan pemukiman penduduk sekitar pabrik tidak melebihi ambang batas yang diperkenankan ?. (2) Apakah konsentrasi radioaktif thorium dan anak luruhnya yang terkandung di udara dalam kawasan pabrik dan pads pemukiman penduduk terdekat sekitar pabrik tidak memiliki potensi bahaya radiasi yang melebihi nilai batas bahaya yang diizinkan bagi pekerja dan penduduk disekitar pabrik ?. (3) Apakah ada perbedaan risiko bahaya radiasi antara penduduk terdekat sekitar pabrik dengan penduduk yang bennukim jauh dari pabrik dan jika ada perbedaan, seberapa jauh perbedaan risiko/bahaya tersebut ?.
Tujuan umum penelitian ini untuk mengetahui kualitas udara dalam kawasan pabrik dan pemukiman penduduk terdekat sekitar pabrik serta potensi bahaya radiasinya terhadap pekerja dan penduduk. Tujuan khusus : (I) mengidentifikasi terjadinya pencemaran radioaktif thorium ke udara pabrik dan pemukiman penduduk terdekat sekitar pabrik, (2) menentukan besarnya potensi bahaya pencemaran radioaktif thorium yang berasal dari pabrik ini terhadap pekerja dan penduduk terdekat di sekitar pabrik, (3) menentukan besarnya perbedaan risiko/bahaya radiasi antara penduduk terdekat sekitar pabrik dengan penduduk yang jauh dari pabrik.
Hipotesis yang diajukan : (1) konsentrasi nuklida radioaktif thorium dan anak luruhnya di udara kawasan pabrik dan di udara dalam pemukiman penduduk terdekat sekitar pabrik tidak melebihi ambang batas konsentrasi radioaktif thorium dan anak luruhnya yang diizinkan, (2) konsentrasi nuklida radioaktif thorium dan anak luruhnya yang terkandung di udara kawasan pabrik dan dalam kawasan pemukiman penduduk terdekat sekitar pabrik tidak memiliki potensi bahaya yang melebihi nilai batas yang diizinkan bagi pekerja dan penduduk, (3) ada perbedaan risiko/bahaya radiasi antara penduduk terdekat sekitar pabrik dan penduduk yang jauh dari pabrik dengan nilai perbedaan yang nyata.
Metodologi penelitian yang dipergunakan adalah sebagai berikut; Pemilihan lokasi penelitian pabrik kaos lampu di Cengkareng ini berdasarkan pada pertimbangan lokasi pabrik berdekatan dengan lingkungan pemukiman penduduk yang cukup padat dan juga merupakan pabrik kaos lampu yang mempunyai kapasitas produksi terbesar di Jakarta dengan pemakaian bahan thorium nitrat 3 ton per bulan.
Sebagai unit analisis dalam penelitian ini adalah udara dan manusia yaitu pekerja dan penduduk. Teknik pengambilan sampel udara secara sampling purposip non probabilitas, berdasarkan pertimbangan; (1) jarak dari tempat kegiatan, (2) pembagian daerah medan radiasi sesuai dengan SK Dirjen BATAN No. PN 03/11601DJ1$9 tentang ketentuan Keselamatan Kerja terhadap Radiasi, (3) keberadaan pekerja atau penduduk pada lokasi sampling, (4) besarnya radioaktivitas yang terukur pada lokasi sampling sebagai fungsi jarak, (5) keterbatasan tenaga, waktu dan biaya. Berdasarkan pertimbangan teknik pengambilan sampel udara tersebut di atas maka titik sampel udara yang diambil dalam kawasan pabrik berjumlah 16 (enam betas) titik sampel dan pada batas pagar pabrik serta luar kawasan pabrik berjumlah 12 (dua betas) titik sampel.
Sedangkan sampel pekerja yang dipilih adalah pekerja radiasi pada kegiatan produksi yang bekerja menangani kaos lampu yang telah mengandung thorium nitrat dan penduduk yang dipilih sebagai sampel yaitu penduduk yang bermukim terdekat sekitar pabrik, baik bagian depan, belakang, kiri dan kanan pabrik. Besarnya sampel penduduk yang diambil berkisar 5%- 10% dari jumlah total penduduk pada setiap bagian dari daerah penelitian. Berdasarkan pertimbangan tersebut dipilih 30 sampel penduduk untuk setiap bagian daerah yang diamati.
Pengumpulan data primer dilaksanakan dengan cara pengukuran langsung menggunakan peralatan lapangan dan laboratorium, wawancara berdasarkan kuesioner. Data sekunder diperoleh dari bahan literatur, dari pabrik kaos lampu serta instansi lain yang berkaitan dengan masalah yang diteliti.
Analisis data untuk memecahkan masalah tingkat pencemaran dan potensi bahaya radiasi yaitu analisis spektrum hasil pencacahan dengan metode penentuan puncak spektrum secara langsung kemudian dilanjutkan dengan perhitungan menggunakan perumusan matematis dan analisis statistik uji t.
Untuk menyelesaikan masalah perbedaan risiko/bahaya radiasi antara penduduk terdekat sekitar pabrik dengan yang jauh dari pabrik menggunakan analisis kuantitatif risiko relatif dengan desain kasus-kontrol, variabel bebas paparan radiasi dan variabel terikat dosis radiasi yang diterima penduduk, selanjutnya dilakukan test kemaknaan uji Chi-Square yang diteruskan dengan uji koefisien kontingensi.
Dari hasil penelitian dapat diketahui bahwa konsentrasi thorium-228 dan thoron di udara dalam kawasan pabrik kaos lampu tidak melebihi nilai ambang batas yang diizinkan untuk daerah kerja radiasi yaitu 22,2.105 Bq/l untuk thorium-228 dan 11,1 Bq/l untuk thoron. Nilai konsentrasi thorium-228 dan thoron yang diperoleh dalam daerah sumber kegiatan produksi, yaitu thorium-228 berkisar dari tak terdeteksi sampai 1,56.10 Bq/l dan untuk thoron berkisar antara 4,47-11,04 SO. Tingkat pencemaran thoron dalam daerah sumber ini sudah terindikasi tetapi belum melebihi ambang batas yang diizinkan, sedangkan tingkat pencemaran thorium-228 tidak terindikasi. Pada daerah luar ruang kegiatan tetapi masih dalam kawasan pabrik, konsentrasi thorium-228 dari tak terdeteksi sampai dengan 8,05. 10'' Bq/l dan konsentrasi thoron berkisar antara 0,01-4,62 Bq/l, nilai ini sudah cukup rendah dibandingkan dengan nilai ambang batas yang diizinkan, bahkan konsentrasi thorium 228 sangat rendah. Nilai konsentrasi thorium-228 dan thoron dalam kawasan pemukiman penduduk terdekat pada daerah penelitian, dari talc terdeteksi sarnpai 4,03.I0-v Bq/1 dan 0,0007 - 0,08 BO. Nilai ambang batas konsentrasi thorium-228 dan thoron yang diizinkan dalam daerah pemukiman penduduk sebesar 1.10-5 Bq/l dan 0,4 BO.
Besarnya tingkat potensi bahaya hasil penelitian yang diindikasi melalui besaran tingkat kerja dan dosis ekivalen efektif, yang diterima pekerja dan penduduk masih jauh di bawah nilai batas yang diizinkan, jadi belum mengidentifikasikan keadaan yang cukup berbahaya bagi pekerja dan penduduk. Nilai tingkat kerja yang diperoleh untuk pekerja berkisar dari 0,034-0,245 WL serta nilai dosis ekivalen efektif berkisar dari 5,6-20,96 m 5v/tahun, sedangkan nilai tingkat kerja yang diperoleh penduduk berkisar antara 0,001-0,013 WL dan nilai dosisnya berkisar dari 0,013-0,467 mSv/tahun. Ambang batas tingkat kerja dan dosis ekivalen efektif yang diizinkan untuk pekerja sebesar 1,2 WL dan 50 mSv/tahun serta untuk penduduk sebesar 0,04 WL dan I mSv/ tahun.
Hasil analisis risiko/bahaya radiasi bagi penduduk terdekat di belakang pabrik (berjarak 5-20 meter dari pagar belakang pabrik) dengan penduduk yang bermukim jauh dari pabrik (500-520 meter belakang kiri pabrik) adalah 16 (enam belas) kali, ini berarti bahwa penduduk yang bermukim dekat dengan pabrik akan mengalami kemungkinan menerima paparan radiasi interna sebesar 16 (enam belas) kali lebih besar dari penduduk yang bermukim jauh dari pabrik.

ABSTRACT
The use of radioactive material in Indonesia is becoming wider in various aspects of life, which covers many sectors in The National Development such as in nuclear medicine, agriculture, hydrology and industry.
Utilization of nuclear energy is aimed to increase people's welfare by emphasizing the safety and health of the community. However, the atomic energy not only provides benefits but also causes danger to the radiation workers, community and other environmental components. This requires a strict control and development in its operation. A radiation monitoring is required for industries, which utilize radioactive material in their production process.
An industry, which utilizes natural thorium radioactive material in the form of Thorium Nitrate (ThNO3) as a mixture of its raw material, or nylon fiber net lining is the incandescent gas mantle industry.
The production process of the incandescent gas mantle not only produce the incandescent gas mantle but also liquid, solid, and gas radioactive waste which are disposed to the environment with certain requirements. In this research will be investigate the thoron gas waste and solid waste in the form of radioactive dust particle which resulted from production process enable the air contamination in the plant and its vicinity area. This will cause the increase of the environmental radioactivity level.
The increasing environmental radioactivity in the air produces an internal and external danger potential, which threatens the workers and the community in the vicinity area of the plant. Thorium and its daughter product which is adhered to the air dust of the plant and the community settlement around the plant will be inhaled by the plants' workers and or the community, and then goes through lungs, which will cause an internal contamination. This will endanger the workers in the community. The radiation danger can be indicated in the form of working level and effective equivalent dose of lungs received by workers and the community. The value of the magnitude is compared with the permitted value.
Having considered the danger potential, it is necessary to conduct a research of radioactivity level in the plant working area and the outside of the incandescent gas mantle plant in the closest community settlement area. The danger level toward the workers and the community around the project can be estimated. Due to this condition some research questions arise: (1) whether the radioactive concentration in the air around the area and around the plant, which is resulted from the plant activities, not exceeds the limit threshold value allowed? (2) Whether the radioactive concentration in the air of the plant area and the closest community settlement around the plant have no radiation danger potential that not exceeds the limit threshold value allowed toward workers and the community? (3) Whether there is a risk or radiation danger between the closest community around the plant and those that settle far away from the plant and if there is a difference, what is the risk ratio between two of them?
The general objective of this research is to identify the air quality and radiation danger potential toward worker in the plant area and the community in the closest settlement area around the plant. The specific objectives are : (1) to identify the occurrence of thorium radioactive contamination in the plant air and the closest community settlement around the plant, (2) to determine thorium radioactive contamination danger potential from the plant toward workers and the closest community around the project, (3) to determine quantity of risk or radiation danger difference between the closest community around the plant and the community far away from the plant.
The hypothesis proposed: (1) the concentration of thorium radioactive nuclide and its daughter product in the air of plant area and the air of the closest community settlement area around the plant does not exceed the threshold of the permitted radioactive concentration, (2) Thorium radioactive nuclide' concentration and its daughter product in the air and the closest community settlement area have no danger potential, that not exceeds the limit threshold value allowed toward workers and the community, (3) there is difference in risk between the community around the plant and those of far away from the plant, with significant different value. The methodology used is as follows; the selection of the incandescent gas mantle in Cengkareng and the closest community settlement environment based on consideration that the plant location nears the densely populated settlement area. Besides, the plant has the largest production capacity in Jakarta, which uses 3 tons of nitrate thorium.
As a unit of analysis in this research is the air and human being, that is workers and community. The air sampling techniques is non-probability purposive sampling, based on consideration: (1) distance from the site of activity, (2) division of radiation filed area according to decree of Directorate General of BATAN (National Atomic Energy Agency) No. PN 0311 I501DJ/89 concerning Work Safety Regulation toward radiation, (3) presence of workers or community in the sampling location, (4) the amount of radioactivity measured in the sampling location as a function of distance, (5) lack of personnel, time and fund. In the air sampling techniques the number of air sampling points in the plant area is 16 and in the plant fence, outside of the plant area is 12 samples.
While the workers samples area selected from radiation workers in production activity which handle the incandescent gas mantle which contain nitrate thorium. The community selected, as samples are those who live closest to the plant, in the front, in the back, the right and the left of the plant. The amount of samples taken was range from 5% - 10% of the total community in each research area. Based on the
The primary data collection is done by a consideration 30 samples of people are selected for each area observed direct measurement using field equipments and laboratories, interview based on questionnaire. While the secondary data is obtained from literatures and from the incandescent gas mantle and other related instances relevant with the problems being studied.
The data analysis to solve the contamination level and radiation danger potential is done by spectrum analysis of the counting results with direct spectrum peak determination method which then continued with counting using mathematical formulation and t-test statistical analysis. While to solve the radiation danger risk difference between the community closest to the plant and those of far away from the plant using relative risk quantitative analysis with design of case-control, radiation exposure independent variable which is received by the community. Then a chi-square significance test is done which then continued with the contingency coefficient test.
From the research result, it can be identified that the thorium-228 and thoron concentration in the air of the incandescent gas mantle plant are not exceeding the threshold value allowed for radiation area that is 22,2 10-5 Bq/l for thorium-228 and 11,1 Bq/l for thoron. The thorium-228 and thoron concentration observed in production activity area range from no detectable to 1,56.10-5 Bq/l for thorium-228 and range from 4,47 to 11.04 Bq/l for thoron.
The thoron contamination level in the source area have been indicated, but have not exceeds the allowed threshold value, while the thorium-228 contamination level is not indicated. For outside area of the plant environment, the thorium concentration from undetectable to 8,05.10 Bq/l and thoron concentration range from 0,01 - 4,62 BO, the value is relatively low compared with the allowed threshold value, the thorium-228 concentration is very low. While thorium-228 concentration value in the closest community in the researched region, from undetectable to 4,03.10' Bq/l and 0,0007 - 0,08 BO. The thorium-228 threshold and thoron allowed in the community settlement is 1.105 and 0,4 Bq/l.
The extent to which the danger potential of the research result indicated through the performance level and effective equivalent dose, which is received by workers and the community is far below the allowed value limit. The value obtained, performance level for workers range from 0,034 - 0,245 WL and its effective equivalent dose range from 5,6 - 20,94 mSv, while for the community the performance level range from 0,001 - 0,013 WL and its dose range from 0,014 - 0,467 mSv. The performance limit value and effective equivalent dose allowed for workers is 1,2 WL and 50 mSv/year and for community is 0,04 WL and 1 mSv/year.
The radiation exposure risk-analysis for the community in the back of the plant (5- 20 m from the back fence of the plant), and the community far away from the plant (500 - 520 m in the back left of the plant) is 16 times larger, which means that the community close to the plant will exposure internal radiation exposure 16 times than those that live far away from the plant.
"
Jakarta: Program Pascasarjana Universitas Indonesia, 1994
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Suwarso
"RINGKASAN
Manusia dengan segala kegiatannya selalu dikelilingi oleh radiasi. Radiasi terbesar yang diterima oleh manusia yakni lebih dari 80% berasal dari radioaktivitas alam, yang terjadi karena adanya radionuklida. Di antara radionuklida tersebut adalah U-238 yang dalam deret peluruhannya menghasilkan Ra-226 dan Rn-222 sebagai induk Pb-210.
Dalam ekosistem Sungai Donan terjadi kematian bakau yang intensitas kematiannya berbeda dari hulu ke hilir. Selain itu juga terjadi perubahan sifat biologinya yang diperlihatkan oleh bentuk kekeringan daunnya. Pada hewan benthos terjadi perubahan komposisi dan jenis yang ditandai oleh menurunnya indeks keanekaragaman ( diversity) dari 0,732 menjadi 0,292. Kejadian-kejadian tersebut diduga karena perubahan lingkungan di ekosistem sungai Donan yang disebabkan karena adanya cemaran radioaktif Pb-210 bukan karena perubahan sifat fisik kimia air sungai. Hal ini dikatakan demikian karena ternyata kadar parameter air sungai seperti pH, DO, BOD, COD, dan kandungan hidrokarbon masih rendah, jadi belum bisa memperlihatkan indikasi terjadinya pencemaran air sungai tersebut.
Cemaran Pb-210 diduga berasal dari kegiatan industri yang terletak di tepi sungai Donan terutama Pabrik Semen Nusantara, karena bahan baku semen dan bahan bakar yang digunakan mengandung gas radon Rn-222 yang meluruh menjadi Pb-210.
Sehubungan dengan itu telah dilakukan studi mengenai
pemantauan akumulasi Pb-210 dalam sedimen dan pada akar Rhizopora. Dari studi yang telah dilakukan dapat diketahui bahwa Pabrik Semen Nusantara merupakan sumber cemaran Pb-210.
Hasil yang diperoleh ialah bahwa aktivitas Pb-210 tidak berbeda antara waktu pasang dan surut, yakni berkisar antara 1.10-9-7.10-9 Ci atau antara 1,51-15,4 dpm/gram sedimen. Sedangkan aktivitas Pb-210 pada akar Rhizopora antara 0,89-2,1 dpm/gram akar atau 0,8.10-9-3.10-9 Ci_ Selain itu juga diperoleh korelasi antara jarak tempat dan aktivitas Pb-210 dengan koefisien korelasi r = 0,98 dengan persamaan regresi y = 5,8-0,5x, yang berarti ,bsemakin jauh dari sumber dalam hal ini pabrik semen, aktivitasnya semakin menurun.

Summary
Man and their activity enclosed by radiation. The biggest part of radiation accepted by man comes from natural radioactivity. More than 80% radioactivity in the environment comes from natural radioactivity. Radioactivity caused by radionuclide. One of the radionuclide is U-238, which in its series decay produces Ra-226 and Rn-222 as the parent of Pb-210. In the Donan River ecosystem mangrove death has occurred with difference intensity from up stream
to down stream. Biological changing also has occurred showing by the leaf drought type. In benthos organism composition and variety changing also has accoured. Showing the decrease in diversity index from 0,732 to 0,292.
It is caused by the environmental change appearing in Donan River ecosystem which is assumed to be the radioactivity pollution of Pb-210, so it is not by physical-chemical characteristics changing of the river water, because its parameters concentration such as pH, DO, BOD, COD, and hydrocarbon are still low indicating that the river is still in unpolluted condition.
The source of Pb-210 is assumed to be the activity of industries lying at the side of river, especially Nusantara Cement Factory, wich use raw material and fuel producing radon gas Rn-222 that decays to Pb-210.
A study about monitoring Pb-210 accumulation in the sediments of River Donan and Rhizopora roots had been performed. From this study it is found that cement factory is the source of Pb-210 pollution. The results of study are that the tidal current does not influence Pb-210 activity, and its range is between 1,51-15,4 dpm/gram sediment. Pb-210 activity in the root raging from 0,80.10-9-3.10-9 Ci or 0,89-2,1 dpm/gram of the roots.
It is also found that there is a correlation between the distance and the activity of Pb-210, with the correlation Coefficient r=0,98 and the regression function is Y = 5,8-0,5X, meaning that the more the distance from its source the less is its activity.
"
Jakarta: Program Pascasarjana Universitas Indonesia, 1994
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>