Pengaruh Penurunan Kualitas Beton Terhadap Kinerja Seismik Gedung 8 Lantai dengan Variasi Kolom Miring dan Kantilever Berbasis Analisis Dinamik Linear Tier 3 = The Effect of Concrete Quality Degradation on the Seismic Performance of an 8-Story Building with Variations of Inclined Columns and Cantilevers Based on Tier 3 Linear Dynamic Analysis

Dicky Prasetyo; Mulia Orientilize, supervisor; Yuskar Lase, supervisor; Bastian Okto Bangkit Sentosa, examiner; Josia Irawan, examiner; Josia Irawan Rastandi, examiner (Fakultas Teknik Universitas Indonesia, 2025)

 Abstrak

SNI 2847:2019 dalam Pasal 26.12.4.1 menyatakan bahwa batas penerimaan kualitas beton adalah 85% kekuatan rencana dari rata-rata 3 beton inti. Namun, saat ini belum banyak ditemukan penelitian terkait dampak penurunan kualitas beton tersebut terhadap kinerja struktur dan seismik dari bangunan. Selain itu, bagaimana syarat tersebut dapat diterima pada bangunan dengan adanya kolom miring dan kantilever juga perlu dilakukan penelitian lebih lanjut, mengingat perkembangan desain arsitektur yang semakin beragam saat ini. Penelitian ini bertujuan mengevaluasi dampak penurunan mutu beton terhadap kinerja seismik gedung delapan lantai berbentang tunggal yang dirancang menggunakan Sistem Rangka Pemikul Momen Khusus (SRPMK) dengan variasi kolom miring dan kantilever. Berdasarkan pedoman ASCE 41-17, evaluasi dilakukan menggunakan metode respon spektrum berbasis linear dinamis tier 3. Penelitian meninjau dampak penurunan kualitas beton sebesar 7,5%, 15%, dan 25% terhadap kebutuhan tulangan dan kinerja seismik. Hasil penelitian menunjukkan adanya peningkatan signifikan pada kebutuhan tulangan serta kinerja seismik struktur seiring dengan terjadinya penurunan kualitas beton. Selain itu, keberadaan kolom miring dan kantilever akan memberikan dampak terhadap perilaku struktur dalam kinerja seismiknya.

SNI 2847:2019 Article 26.12.4.1 stipulates that the acceptable limit for concrete quality is 85% of the design strength based on the average of three core concrete samples. However, current studies on the impact of such reductions in concrete quality on the structural and seismic performance of buildings remain limited. Moreover, how this requirement applies to buildings featuring inclined columns and cantilevers also requires further investigation, particularly considering the increasing complexity of modern architectural designs. This study aims to evaluate the impact of reduced concrete quality on the seismic performance of an eight-story, single-span building designed using a Special Moment Resisting Frame (SMRF) system with variations in inclined columns and cantilevers. In accordance with ASCE 41-17 guidelines, the evaluation is conducted using the Tier 3 linear dynamic response spectrum method. The study examines the effects of concrete strength reductions of 7,5%, 15%, and 25% on reinforcement demand and seismic performance. The results show a significant increase in reinforcement requirements as well as changes in the structural seismic performance corresponding to the reduction in concrete quality. Furthermore, the presence of inclined columns and cantilevers significantly affects the structural behavior under seismic conditions.

 File Digital: 1

Shelf
 S-Dicky Prasetyo.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2025
Bahasa : ind
Sumber Pengatalogan : LIbUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xxiii, 192 pages : illustration + appendix