Analisis Ketebalan Pelat Dinding dan Sisa Umur Pakai Pada Tangki Penimbun Nomor T-01B Berdasarkan Standar American Petroleum Institute (API) 653 = Analysis of Shell Plate Thickness and Remaining Life For Storage Tank Number T-01B Based On American Petroleum Institute (API) 653

Fajri Saputra; Muhammad Arif Budiyanto, supervisor; Sunaryo, examiner (Fakultas Teknik Universitas Indonesia, 2024)

 Abstrak

Laporan praktek keinsinyuran ini menganalisis ketebalan pelat dinding tangki penimbun dan menghitung sisa umur pakai tangki penimbun T-01B milik PT Pertamina Patra Niaga Integrated Terminal Teluk Kabung, dengan mengacu kepada Standar API 653 Tank Inspection, Repair, Alteration, and Reconstruction. Analisis dilakukan dengan membandingkan ketebalan pelat dinding aktual (t_aktual) dengan ketebalan pelat dinding minimum yang dipersyaratkan berdasarkan perhitungan standar API 653 (t_min), sehingga didapatkan nilai laju korosi dan sisa umur pakai. Hasil analisis menunjukkan nilai t_aktual masih lebih besar dibandingkan dengan t_min. Dari hasil perhitungan tersebut, kemudian didapatkan nilai laju korosi terbesar 0,08 mm/tahun dan sisa umur pakai yaitu 41 tahun. Kesimpulan yang didapatkan adalah ketebalan pelat dinding tangki saat ini masih dapat diterima dan tangki penimbun T-01B masih dapat dioperasikan hingga jadwal pemeriksaan selanjutnya yakni 5 tahun.

This practical report described about evaluation of shell plate and calculation of the remaining life of T-01B storage tank owned by PT Pertamina Patra Niaga Integrated Terminal Teluk Kabung, according to API Standard 653 Tank Inspection, Repair, Alteration, and Reconstruction. The evaluation is performed by comparing actual shell plate thickness (t_aktual) to minimum thickness required (t_min) according to API Standard 653, so the corrosion rate and remaining life can be calculated. The result of evaluation shown that the value of t_aktual are still greater than t_min, the highest corrosion rate is 0.08 mm/year, and remaining life is 41 years. In conclusion, t_aktual is still accepted and the storage tank T-01B can be operated until the next 5 years for thickness inspection.

 File Digital: 1

Shelf
 PR-Fajri Saputra.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Tugas Akhir
No. Panggil : PR-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2024
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiv, 45 pages : illustration
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
PR-pdf 16-25-87029564 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920564510
Cover