Studi Eksperimental Ionic Liquid Dehumidifier Dengan Heat Exchanger Jenis Finned And Tube = Experimental Study of Ionic Liquid Dehumidifier With Heat Exchanger Finned And Tube Types

Muhammad Salim Al Haddar; Muhammad Idrus Alhamid, supervisor; Nasruddin, examiner; Budihardjo, examiner; Arnas, examiner (Fakultas Teknik Universitas Indonesia, 2021)

 Abstrak

Indonesia merupakan negara yang memiliki kelembaban yang cukup tinggi dan cuaca yang cukup panas. oleh karena itu negara Indonesia membutuhkan alat pengering udara agar kelembaban dapat turun sampai titik nyaman untuk manusia. Pendingin udara pengering cair merupakan alternatif untuk teknologi dehumidifikasi udara karena dapat meningkatkan kualitas udara dan mengurangi konsumsi energi utamanya. Penelitian ini melakukan penyelidikan eksperimental untuk mengetahui rasio kelembapan terhadap udara untuk mengetahui karakteristik cairan ionik. Untuk percobaan, kemasan terstruktur terdiri dari koil pendingin tabung bersirip. Dimana cairain ionik mengalir secara vertikal melalui koil pendingin dari atas ke bawah, sedangkan udara mengalir secara horizontal, menjadikannya konfigurasi aliran silang, dan air pendingin mengalir di dalam tabung. Penelitian ini akan menentukan pengaruh flow rate cairan ionik ini dalam penyerapan air di udara. Flow rate yang digunakan dalam peneletian ini sebesar 80, 100, 120, 150, 170 l/h. Nilai rata-rata delta rasio kelembaban pada dehumidifikasi berturut-turut adalah 2.8, 3.3, 4.1, 4.9, 5.5 g/kg. Sedangkan nilai rata-rata delta rasio kelembaban pada humidifikasi berturut-turut adalah 10.1, 8.3, 5.9, 4.5, 3.1 g/kg.

Indonesia is a country that has high humidity and hot weather. Therefore, Indonesia needs a dryer so that the humidity can drop to a comfortable point for humans. Air conditioning is an alternative to air dehumidification technology because it can improve air quality and reduce its main energy consumption. This study conducted an investigation to determine the ratio of humidity to air to determine the characteristics of ionic liquids. For the experiment, the structured packaging consisted of a finned tube cooling coil. In which the ionic liquid flows vertically through the cooling coil from top to bottom, while the air flows horizontally, setting up crossflow, and the cooling air flows in the tube. This study will determine the effect of the flow rate of ionic liquids on the absorption of air in the air. The flow rates used in this study were 80, 100, 120, 150, 170 l/h. The average value of the delta humidity ratio in dehumidification was 2.8, 3.3, 4.1, 4.9, 5.5 g/kg, respectively. While the average value of the delta humidity ratio in humidification is 10.1, 8.3, 5.9, 4.5, 3.1 g/kg, respectively.

 File Digital: 1

Shelf
 S-Muhammad Salim Al Haddar.pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2021
Bahasa : ind
Sumber Pengatalogan : LibUi ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiii, 36 pages : ilustration
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S-pdf 14-25-72948526 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920559998
Cover