UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Studi pengaruh mampu serap air terhadap sifat mekanis dan degradasi kimia pada komposit epoksi e glass di lingkungan nacl 3 5 melalui uji celup = The effect of water absorption on the mechanical properties and chemical degradation of epoxy e glass composite in nacl 3 5 environment through immersion test

Lutfia Aswin Amvani; Rini Riastuti, supervisor (Fakultas Teknik Universitas Indonesia, 2014)

 Abstrak

Material FRP (Fiber Reinforced Polymer) diaplikasikan sebagai pipa pada offshore platform dan shipboard piping. Fluida yang mengalir dalam pipa FRP bersifat korosif dengan suhu operasi 75˚C dan 95˚C. Material FRP mudah menyerap molekul air yang mengakibatkan penurunan sifat mekanis dan degradasi kimia. Komposit epoksi/E-glass pada penelitian ini diberikan perlakuan melalui uji celup dalam larutan NaCl 3,5% pada suhu 75˚C dan 95˚C. Setelah proses perendaman, komposit epoksi/E-glass dilakukan pengujian tarik, SEM dan FTIR. Hasil pengujian tarik menunjukkan tidak ada perubahan sifat mekanis pada epoksi/E-glass setelah proses perendaman. Pengujian SEM menunjukkan adanya microvoid berukuran ±3µm pada epoksi/E-glass yang diperoleh dari proses manufaktur. Seiring dengan peningkatan suhu, terdapat microvoid baru berukuran ±2µm yang disebabkan oleh fibre entanglement pada 75˚C dan rongga-rongga berukuran ±100µm di dekat serat gelas yang disebabkan oleh pembelahan rantai molekul pada matriks epoksi. Microvoid dan rongga tersebut menyebabkan meningkatnya mampu serap air epoksi/E-glass namun ternyata tidak mempengaruhi sifat mekanis. Perubahan warna larutan NaCl 3,5% dan hasil pengujian FTIR membuktikan adanya degradasi kimia pada epoksi/E-glass setelah proses perendaman pada suhu 75˚C dan 95˚C.

Fiber Reinforced Polymer was applied as a pipe on offshore platforms and shipboard piping. The fluid which flows in that FRP pipe is corrosive with an operating temperature 75˚C and 95˚C. FRP material readily absorbs water molecules resulting in a decrease in mechanical properties and chemical degradation. Epoxy/E-glass composite in this study are given treatment by immersion test in 3.5% NaCl solution at temperature 75˚C and 95˚C. After immersion, epoxy/E-glass composite is tested by tensile testing, SEM and FTIR. The results of tensile testing showed there is no change in the mechanical properties of epoxy/E-glass after immersion. Photo SEM showed there is microvoid with size ± 3μm in epoxy/E-glass that obtained from manufacturing process. As temperature increases, there is new microvoid with size ± 2μm caused by fibre entanglement at 75˚C and many cavities that located near fibre glass with size ± 100μm caused by the termination of molecule chain in an epoxy matrix. The microvoid and the cavity is able to cause an increase in water absorption of epoxy/E-glass, but did not affect the mechanical properties. Color change of 3.5% NaCl solution and FTIR testing results prove there is chemical degradation of epoxy/E-glass composite after immersion at temperature 75˚C and 95˚C.

 File Digital: 1

Shelf
 S58438-lutfia aswin amvani .pdf :: Unduh

LOGIN required

 Metadata

Jenis Koleksi : UI - Skripsi Membership
No. Panggil : S58438
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Program Studi :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2014
Bahasa : ind
Sumber Pengatalogan :
Tipe Konten :
Tipe Media :
Tipe Carrier :
Deskripsi Fisik : xii, 54 hlm. : ill. ; 29 cm. + lamp.
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
S58438 14-25-98966195 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20402377
Cover