UI - Tesis Membership :: Kembali

UI - Tesis Membership :: Kembali

Efek perlakuan panas terhadap sifat magnet baja tahan karat tipe 304 dan pengaruhnya pada kesalahan penimbangan = Effect of heat treatment on magnetic properties of stainless steel 304 and its effect on the weighing error

Renanta Hayu Kresiani; Bambang Soegijono, supervisor; Babmabng Soegiono, examiner; Muhammad A.S. Hikam; Dede Djuhana, examiner (Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2013)

 Abstrak

Penggunaan timbangan kompensasi elektromagnetik dalam proses pengukuran massa di laboratorium menimbulkan potensi peningkatan kesalahan penimbangan yang diakibatkan oleh interaksi antara medan magnet pada pinggan timbangan dengan sifat suseptibilitas magnet standar massa yang terbuat dari baja tahan karat austenitik pada saat dilakukan kalibrasi. Penelitian ini dilakukan untuk mengamati sifat suseptibilitas magnet serta kesalahan penimbangan pada baja tahan karat tipe 304 serta perubahan sifatnya setelah dilakukan perlakuan panas pada suhu 800°C dan 1100°C.
Hasil penelitian ini menunjukkan bahwa nilai suseptibilitas magnet serta kesalahan penimbangan menurun pada sampel yang mengalami perlakuan panas pada suhu 800°C serta memenuhi persyaratan nilai suseptibilitas magnet untuk standar massa kelas E2. Sedangkan sampel yang dipanaskan pada suhu 1100°C nilai suseptibilitas magnet dan kesalahan penimbangannya meningkat. Perubahan nilai suseptbilitas magnet ini konsisten dengan perubahan fraksi massa fasa ferrit pada baja tahan karat tipe 304 yang diperoleh dari hasil analisis XRD.

The use of electromagnetic force compensation balances in laboratory may increase potential error caused by interaction between electromagnetic field affecting weghing pan of the balannce and magnetic succeptibility of mass standards which made of austenitic stainless steel. The evaluation of magnetic succeptibility and its effects to the weighing error of stainless steel 304 as well as magnetic succeptibility change caused by heat treatment on 800°C dan 1100°C were examined in this research.
The results shows that the magnetic succeptibility and its weighing error of sample with heat treatment on 800°C decrease and meet the magnetic suseptbility requirements of E2 class. Whereas for sample with heat treatment on 1100°C the value of magnetic suseptibility and error weighing increase. The change of the magnetic suseptibility consistent with the change of weight percent of ferrite on stainless steel 304 obtained based on XRD analysis.

 File Digital: 1

Shelf
 T34960-Renata Hayu Kresiani.pdf :: Unduh

LOGIN required

 Kata Kunci

 Metadata

Jenis Koleksi : UI - Tesis Membership
No. Panggil : T34960
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Program Studi :
Subjek :
Penerbitan : Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2013
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xii, 45 pages : illustration 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
  • Sampul
No. Panggil No. Barkod Ketersediaan
T34960 15-25-72392237 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20350295
Cover